ByoPlanet ES-120 User manual

Type
User manual

ByoPlanet ES-120 is an electrostatic sprayer system designed for both indoor and outdoor commercial use. It features an electrostatic spray technology that provides even coverage and reduces chemical usage by up to 50%. The ES-120 can be used with a variety of approved chemicals, making it suitable for various applications such as disinfecting, pest control, and odor control.

ByoPlanet ES-120 is an electrostatic sprayer system designed for both indoor and outdoor commercial use. It features an electrostatic spray technology that provides even coverage and reduces chemical usage by up to 50%. The ES-120 can be used with a variety of approved chemicals, making it suitable for various applications such as disinfecting, pest control, and odor control.

www.ByoPlanet.com
OPERATING INSTRUCTIONS
CS-900 CART SERIES
ELECTROSTATIC SPRAY SYSTEM
ES-120 SPRAYER SERIES
ELECTROSTATIC SPRAY SYSTEM
For Indoor and Outdoor
Commercial Use
For service and support, contact
w ww. S er vi ceTe chTe am . co m .
Operators Manual
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
1
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Before operating your CS-900™ Electrostatic Spray System follow the
instructions listed on the ES-120™ Unpacking and Assembly Protocol to
prepare the sprayer for operation.
Before operation read through the CS-900™ Electrostatic Spray System
Instruction Manual and view the included Training Video to acquaint the
operator with basic operations and maintenance protocol.
NOTE: It is required that any and all operators are provided with a copy
of the Instruction Manual and must view the training video before
operating the equipment.
It is the client’s responsibility to ensure all operators are properly trained
and have reviewed the educational manuals and training video.
1
2
PART 1
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
2
Before connecting the tank, the tank should be oriented with the ByoPlanet
shield facing outwards towards the operator, and the tank handle should be
near the frame of the Electrostatic Spray System, otherwise the tank quick
connects will not t on to the plugs.
3
Correct tank orientation
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
3
Connect the tank quick connects to the tank plugs by pulling up on the col-
lar and pushing the quick connect down onto the plugs.
4
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Attaching the quick connects
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
4
Connect your ES-120™ Electrostatic Sprayer to the appropriate ttings
on the hose from the reel. Refer to the ES-120™ Unpacking and
Assembly Protocol.
5
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Connecting the ES-120™ Electrostatic Sprayer
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
5
Attach the correct voltage extension cord (220v or 110v) to the electrical
plug near the top handle of your CS-900™ Electrostatic Spray System.
6
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
110 Volt Extension Cord Plug
220 Volt Extension Cord Plug
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
6
The power switch should be in the off position before plugging
the extension cord into a wall outlet.
7
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Power Switch In Off Position
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
7
The CS-900™ Electrostatic Spray System must be grounded and
requires its extension cord to be grounded otherwise the equipment
will not function.
A grounded 110v extension cord or adapter will have a three-prong
plug rather than two.
Never use an extension cord or an adapter with only two prongs,
unless the unit operates on 220v (CS-940™ Electrostatic Spray System).
8
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
110 Volt Extension Cord Plug
220 Volt Extension Cord Plug
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
READ THIS FIRST
Before continuing with the operation of your CS-900™ Electrostatic Spray
System, review the provided instructional literature and the training video to
ensure proper understanding and operation.
It is the client’s responsibility to ensure all operators are properly trained
and have reviewed the instructional literature and training video. ByoPlan-
et™ International LLC is not responsible for the improper use of chemicals.
Operators should be familiar with the chemical product label and should
be acquainted with rst aid procedures in case of harmful contact.
Operators should also be familiar with the proper personal protective
equipment required for chemical use by the operators and other parties in
the targeted areas.
8
PART 2
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
9
Insure that the CS-900™ is turned off prior to lling the tank.
1
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Power Switch In Off Position
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
10
Remove the tank lid. The tank lid can be removed by lifting up on the latch
and rotating the tank lid 90 degrees in either direction. Once the lid has
been rotated it can be removed from the tank entirely. Reverse the steps
to reattach the tank lid.
If the tank lid has resistance it is likely that the tank is still pressurized.
At this point, pull the key ring of the pressure relief valve (located on
the tank lid) to depressurize the tank and to allow the lid to be removed.
2
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Depressurizing the Tank By Lifting The Key Ring of the Pressure Relief Valve
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
11
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Removing the Tank Lid
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
12
Carefully pour an approved chemical into the tank.
Chemical should not be poured into the tank while the tank lid is still
present. Any spilled chemicals should be dealt with according to the
instructions on the manufactures label. Chemicals spilled on the
CS-900™ Electrostatic Spray System should be wiped off with a
cloth dampen with warm water.
Check that the tank lid o-ring is still attached to the tank lid and has not
fallen into the tank or been misplaced. Absence of the o-ring will result in
the tank not maintaining its pressure.
Replace the tank lid and depress the latch.
3
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Pouring Chemical
Tank Lid
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
13
Power on the unit by ipping the power switch up.
Your CS-900™ Electrostatic Spray System is now ready for operation.
4
OPERATING YOUR CS-900™ ELECTROSTATIC SPRAY SYSTEM
Power Switch In On Position
125 Old Monroe Road Athens, GA 30606 • 1-877-220-0550 • ByoPlanet.com
14
After operation, it is very important to remove all unused chemical from the
tank. Therefore, it is recommended that the amount of chemical put into
the tank is appropriate for the amount of chemical required for the job.
It is strongly recommended that the tank be rinsed with warm water and
that the water is run through the CS-900™ Electrostatic Spray System and
ES-120™ Electrostatic Sprayer to clear the chemical from the hose line and
sprayer. Failure to routinely ush the system of chemical will result in dam-
age to the equipment. This damage will not be covered by your warranty.
While the CS-900™ Electrostatic Spray System is still on, remove the smaller
hose quick connect from the sprayer handle by pulling down on the quick
connect collar and pulling the quick connect away from the handle. Contin-
ue to depress the trigger to clear the remaining chemical from the ES-120™
Electrostatic Sprayer. Spray until liquid no longer ows through the sprayer.
The outside of the CS-900™ Electrostatic Spray System should be wiped
clean with a cloth dampen with warm water at the end of every workday.
1
2
3
POST-OPERATION MAINTENANCE FOR YOUR
CS-900™ ELECTROSTATIC SPRAY SYSTEM:
Es-120™ Electrostatic Sprayer With Smaller Quick Connect Disconnected
TO PURCHASE
A BYOPLANET
ELEC TROSTATI C
SPRAY SYSTEM
BYOPLANET.COM/SALES
1-877-220-0550
FOR CUSTOMER
COLLATERAL, INCLUDING
OPERATORS MANUAL
AND QUICK START GUIDES
SERVICETECHTEAM.COM
1-877-220-0550
QUESTIONS?
SERVICETECHTEAM.COM
CONTACT US
FOR DEVICE
WARRANTY
INFORMATION
SERVICETECHTEAM.COM
1-877-220-0550
CS-900 OPERATOR MANUAL - VER.02 - 03-04-22
®
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

ByoPlanet ES-120 User manual

Type
User manual

ByoPlanet ES-120 is an electrostatic sprayer system designed for both indoor and outdoor commercial use. It features an electrostatic spray technology that provides even coverage and reduces chemical usage by up to 50%. The ES-120 can be used with a variety of approved chemicals, making it suitable for various applications such as disinfecting, pest control, and odor control.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI