PQNFB17C1
ACPBACnet®Gateway
StandardFeatures:
Electrical:
PowerConsumption
22VA
UnitData:
1.WhencombinedwithACSmartPremiumorPDI,128maxdevicesperV‐Net.
2.PI‐485adapterrequired.ContactEngineeringforalistofcompablesystems.
MustfollowinstallationinstructionsintheapplicableLGinstallationmanual.
Notes:
O
tionalAccessories
soldse
aratel
DigitalOutputKit‐PQNFP00T0
Surroundin
Conditions:
OperatingTemperature
‐4‐140°F
StorageTemperature
‐4‐176°F
Dimensions
10‐11/16"Wx6‐3/16"Hx2‐5/8"D
MaximumNumberofOutdoorUnits
64(16perV‐Net)
•IntegratesMulVandselectMiniandMulSplitsystems²withthirdpartybuilding
managementsystems.
•BTLcerfied(ASHRAE135‐2004)BACnet®ApplicaonSpecificController(B‐ASC)
•Supportsregistraonasaforeigndevice
•20x4characterLCD
•Indoorunitcontrol/monitoringbygroups/indoorunits
•Webaccesswithuseraccesscontrol
•Operaonanderrorhistorylog
•Forcedoffdigitalinput
•Ninedigitalinputsandfourdigitaloutputsfordevice interlocking
BasicUnitFunctions
AdvancedUnitFunctions:
PowerSupply
24VAC60Hz
Connectivit
:
LGCommunications
4Channel/RS‐485V‐Net
CommunicationsCablin
S
ecifications
V‐Net
:
Type
2‐conductor,stranded,shieldedcoppercable/PVCorvinyljacket
Size
AWG18x2
MaximumLength
3,280ft(endtoend)
Descri
tion:
Humidity
0‐95%(non‐condensing)
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
Page1of3
CTRL‐SB‐CH‐002‐US014C18
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
AWG‐AmericanWireGauge
PowerDistributionIndicator(PDI)‐PQNUD1S41
MaximumNumberofDevices
256(64perV‐Net¹)
1
Cover
2RS‐232ConsolePort
3
24VACPowerTerminals
4
ButtonsandLCDDisplay
5
DigitalI/OandRS‐485
ExpansionPort
6
RS‐485V‐NetPorts
7
MiniUSBPort
8
USBPort
9
SDCardSlot
10
EthernetPort
11
PowerSwitch
40VAtransformerrecommended.
Ethernet 10/100BASE‐T
•Operaon–On/Off
•Mode–Auto/Cool/Dry/Heat/FanOnly
•Setpoint
•FanSpeed–Auto/Low/Med/High/Power
•LouverSwing
•TwoSetpointAuto‐Changeover
•TwoSetpointSetback
•200ProgrammableSchedule Eventswithcontrolofsetpoint,On/Off,Mode,Fan
Speed,ControllerLock,andLouverSwing
•TemperatureSetpointRangeLimit
•RemoteControllerLock(All,Setpoint,Mode,FanSpeed)
•RunTimeLimit(UnoccupiedOverride)
•SowareDeviceInterlocking
•ManualControlandSchedulingofDigitalOutputKit
•PeakControl
•VisualFloorplanNavigaon
•PowerDistribuonIndicator(PDI)(oponal)
PI‐485V‐NetInterfaceAdapterforDFS‐PMNFP14A0
BMSCommunications
BACnet/IP(Annex‐J)