  • Hello! I am an AI chatbot trained to assist you with the LG LSN120HSV4 LSN120HSV4 Submittal. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the nominal cooling capacity of the LG LSN120HSV4 indoor unit?
    What is the nominal heating capacity of the LG LSN120HSV4 indoor unit?
    What are the cooling nominal test conditions for the LG LSN120HSV4 indoor unit?
    What are the heating nominal test conditions for the LG LSN120HSV4 indoor unit?
    What type of refrigerant does the LG LSN120HSV4 indoor unit use?
    What is the power supply for the LG LSN120HSV4 indoor unit?
    What is the rated amps for the LG LSN120HSV4 indoor unit?
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
LSN120HSV4
MultiFStandard
Btu/hIndoorUnit12,000
Performan ce:
NominalCoolingCapacity(Btu/h) 12,000
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB Indoor: 70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB
Outdoor:
47°FDB/43°FWB
Electrical:
PowerSupply(V¹/H z/Ø) 208230/60/1
RatedAmps(A)
0.20
Pi
p
in
g
:
Liquid(in,OD) 1/4
Vapor(in,OD)
3/8
ControlsFeatures :
•4Wayaut oswing
•24Houron/offmer
•Autooperaon
•Autorestart
•Chaoswind
•Inverter(variablespeedfan)
•JetCool
•3MHAFfilter
•Selfcleaningindoorcoil
•Sleepmode
•Condensatesensorconnecon
•Groupcontrol
•SmartACmodule
•CompatiblewithSingleZone
HSV4ODU
O
p
tionalAccessories:
ACPIV‐PACP4B000.ENCX LUS
LonWorks®Gateway‐PLNWKB100
ACPIVBACneGateway‐PQNFB17C1
DrainOD,ID(in)
13/16,5/8
TemperatureSensor
Thermistor
Enterin
g
MixedAir:
Cooling(°FWB) 5777
Heating(°FDB)
5981
UnitData:
RefrigerantType R410A
RefrigerantControl
EEV
SoundPressure²H/M/L3dB(A))
39/36/31
PrimaryFilter
WashablePrefilte
r
SecondaryFilter 3MHAF
NetUnitWeight(lbs)
20
ShippingWeight(lbs)
26
Fan:
Type CrossFlow
Quantity
1
Motor/Drive
BrushlessDigitallyControlled/Direc
t
AirflowRateH/M/L(CFM) 335/318/300
Notes:
1.Acceptableoperangvoltage:187V‐253V.
2.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
3.SeeEngineeringManualforsensi bleandlatentcapacies.
4.Allpower/communicaoncabletobemi nimum18AWG,4conductor,stranded,
shieldedandmustcomplywithapplicablelocalandnationalcode.
5.Powerwiringca
blesizemustcomplywiththeapplicablelocalandnaonalcode.
6.Thisunitcomeswithadryheliumcharge.
7.Correspondingrefrigerantpipinglengthisinaccordancewithstandardlengthofeach
outdoorunitandtheleveldifferenceis0ft.Allcapacitiesarenetwithacombinationratio
be
tween95105%
8.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
Page1of2
SBMultiF_Standard_LSN120HSV4_05_15
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredt
rademarkofLGCo
rp./www.lghvac.com
SimpleControllerwithMode(Black)‐PQRCVCL0Q
SimpleControllerwithoutMode(Black)PQRCHCA0Q
SimpleControllerwithMode(White)‐PQRCVCL0QW
SimpleControllerwithoutMode(White)‐PQRCHCA0QW
LGProgrammableThermostat‐PREMTB10U
ACSmartIV ‐PACS4B000.ENCXLUS
DryContactUnit(1cont act,24VACexternalpower)‐PQDSB1
DryContactUnit(2input,powerfromindoorunit)‐PQDSBC
DryContactsforthirdpartythermostat‐PQDSBNGCM1orPDRYCB300
IncludedAccessories:
•WirelessRemoteController‐AKB73835312
NominalHeatingCapacity(Btu/h)
13,800
Foracomplet e listof avail ableaccessori e s ,cont act yourLGrepresentative.
JobName/Location:
Ta g#:
Date:
PONo.:
LSN120HSV4
MultiFStandard
Btu/hIndoorUnit12,000
Page2of2
SBMultiF_Standard_LSN120HSV4_05_15
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
/