Lutz Eccentric screw pump B70H Industry Operating instructions

Type
Operating instructions

This manual is also suitable for

0698-451 B70H - 11/2022
Translation of the original instructions
HORIZONTAL ECCENTRIC SCREW PUMP
Type
B70H
Read this operating instructions before start up!
To be retained for future reference.
en
2
0698-451 B70H - 11/2022
en
Table of Contents
1. Concerning this manual .................................................................................................................... 3
1.1 Terms .......................................................................................................................................... 3
1.2 Target groups ............................................................................................................................. 3
1.3 Associated applicable documents .............................................................................................. 3
1.4 Warnings and symbols ............................................................................................................... 4
1.5 Latest state ................................................................................................................................. 4
1.6 Copyright .................................................................................................................................. 4
2. Safety ............................................................................................................................................ 5
2.1 General safety information ......................................................................................................... 5
2.2 Proper use .................................................................................................................................. 6
2.2.1 Technical data .................................................................................................................... 7
  2.2.2Operationinhazardouslocationorpumpingammableliquids ...................................... 8
2.3 Specicdanger ......................................................................................................................... 11
3. Congurationandfunction ............................................................................................................. 12
3.1 Marking ................................................................................................................................ 12
3.2 Conguration ........................................................................................................................... 13
3.3 Function .................................................................................................................................... 13
4. Transport and storage ..................................................................................................................... 14
4.1 Transport .................................................................................................................................. 14
4.2 Storage ..................................................................................................................................... 14
5. Installation/Assembly and connection ............................................................................................ 14
5.1 Assembly B70H ......................................................................................................................... 15
5.2 Electrical connection of three-phase motors ............................................................................ 16
5.3 Operatingathree-phasemotorwithattachedfrequencyconverter ....................................... 17
5.4 Mechanical loads on the pump tube ........................................................................................ 18
6. Operation ........................................................................................................................................ 18
6.1 Suction funnel .......................................................................................................................... 18
6.2 Directionofow ....................................................................................................................... 19
6.3 Dry running .............................................................................................................................. 19
6.4 Operation with closed discharge .............................................................................................. 19
6.5 Malfunction ............................................................................................................................... 19
7. Taking out of operation ................................................................................................................... 20
8. Maintenanceandservicing ............................................................................................................. 20
8.1 Lubrication ............................................................................................................................... 20
8.2 Repairs ...................................................................................................................................... 20
8.3 Assembling the stator ............................................................................................................... 21
8.4 Sending the pump to the manufacturer ................................................................................... 21
9. Disposal .......................................................................................................................................... 22
10. Traceability ...................................................................................................................................... 22
EU-Declaration of conformity ............................................................................................................... 23
UK Declaration of Conformity ............................................................................................................... 23
3
0698-451 B70H - 11/2022
en
1. Concerning this manual
This manual
is part of this product
• isvalidforallmentionedseries
describes the safe and proper use in all operating stages
1.1 Terms
User: Single person or organisation who is using the products e.g. customer, user, assistant
1.2 Target groups
Target group Task
User Retain these operating instructions at the product’s place of use for
future reference.
Demandthestatoreadandobservetheseinstructionsandthe
additionalvaliddocuments,inparticularthesafetyinformationand
warnings.
Observeadditionalregulationsandinstructionsconcerningtheplant.
Qualiedpersonnel,installer Read,observeandfollowtheseinstructionsandtheadditionalvalid
documents, in particular the safety information and warnings.
Tab. 1: Target groups and their tasks
1.3 Associated applicable documents
Document Purpose
Operatinginstructionsdrivemotor Safe and proper use of the motor
Operating instructions container Safe and proper use of the container
Supplementary operating instructions foradditionaldeliveredcomponents
Tab. 2: Associated applicable documents and purpose
4
0698-451 B70H - 11/2022
en
1.4 Warnings and symbols
Warning Level of risk Consequences in case of
non-compliance
DANGER direct danger death or serious injury
WARNING possible direct danger death or serious injury
CAUTION possible dangerous situation light injury
NOTICE possible dangerous situation damage of property
Tab.3:Warningsandconsequencesincaseofnon-compliance
Symbol Meaning
Safety information
 Complywithallmeasuresthataremarkedwithasafetysigntopreventinjuriesor
death.
iInformation / Recommendation
What to do
Cross reference
3Requirement
Tab. 4: Symbols and meaning
1.5 Latest state
Pleasendthelateststateofthisoperatinginstructionunderwww.lutz-pumpen.de.
1.6 Copyright
The content of this operating instruction and the images contained in them are subject to the copyright
protection of Lutz Pumpen GmbH.
5
0698-451 B70H - 11/2022
en
2. Safety
The manufacturer will not be held responsible for any damages resulting from non-compliance of the
overalldocumentation,inparticularfordamagesincaseofnon-complianceoftheoperatinginstructions.
2.1 General safety information
Observefollowingregulationsbeforeaccomplishingallactivities.
Product safety
Thepumpisconstructedinconformitywiththestateoftheartandapprovedsafety-relatedstandards.
Dangerhowevercanoccurduringuseforlifeandhealthoftheuserorthirdpartiesordamageofthe
pump and other material assets. Therefore:
Operate the pump only in a technically sound state, for its proper use, and conscious of safety and
hazards taking into account these instructions.
Ensure that these instructions and all associated applicable documents are complete, legible, and stored
in a place that personnel can access at all times.
• Refrainfromanymannerofworkingthatendangerspersonneloruninvolvedthirdparties.
• Inthecaseofasafety-relevantmalfunction,stopthepumpimmediatelyandenlistaresponsibleperson
to rectify the malfunction.
• Inadditiontotheoveralldocumentation,observethestatutoryorothersafetyandaccidentprevention
regulations,aswellasthevalidstandardsandguidelinesoftherespectiveoperatingcountry.
Modications
Unlessthemanufacturerhasprovideditsconsentinwriting,themanufacturerisnotliableforinterventions
performedbytheuser(modications)ontheproduct,suchasconversion,alteration,newdesign,etc.
Modicationsnotagreedwiththemanufacturermayhavethefollowingeects,amongothers:
Functional impairments on the appliance or plant
Damage to the appliance and other property damage
• Environmentaldamage
Personal injuries right through to death
Duties of the operator
Safety-conscious working
Operate the pump only in a technically sound state, for its proper use, and conscious of safety and
hazards taking into account these instructions.
• Ensureobservanceandmonitoringof:
- Proper use
- Statutoryorothersafetyandaccidentpreventionregulations
- Safetyprovisionsinhandlinghazardoussubstances
- Validstandardsandguidelinesintherespectivecountryofoperation
• Provideprotectiveequipment.
6
0698-451 B70H - 11/2022
en
Personnel qualication
• Theoperatingpersonnelisrequiredtobeatleast14yearsold.
• Ensurethatpersonneltaskedwithworkonthepumphavereadandunderstoodtheseinstructionsand
allassociatedapplicabledocuments,particularlysafety,maintenanceandservicinginformation,before
they start work.
Clarify responsibilities, competencies and monitoring of the personnel.
• Ensurethatallworkiscarriedoutbytechnicalqualiedpersonnelonly:
- Assembly,servicing,maintenancework
- Work on the electrics
• Personneltobetrainedmustonlyworkonthepumpunderthesupervisionoftechnicalpersonnel.
Safety devices
• Providethefollowingsafetydevicesandensuretheirfunction:
- Withpossibleelectrostaticcharge:providethecorrespondingearthing.
Statutory warranty
• Duringtheguaranteeperiod,obtainthemanufacturer'spermissionformodications,maintenance
work or alteration.
Use only original parts.
Duties of the personnel
• Observethenoticesonthepumpandmaintaintheminalegiblestate,e.g.rotationarrow,markingfor
uidconnections.
• Useprotectiveequipmentwherenecessary.
Do not reach into the intake port of the pump tube.
Only perform work on the pump during downtime.
Ensure that the electric motor is disconnected before you carry out assembly and maintenance work.
• Aftercompletingalltheworkonthemotor,remountthesafetydevicesinaccordancewithspecications.
2.2 Proper use
Each Lutz eccentric screw pump of series B70H comprises a 3-phase or a compressed air motor and a
pumptube.Theowrateanddeliveryheaddependontheselectedpumpsize.Thismeansthatthemost
appropriatepumpcanbechosenforeachindividualapplication.Theapparatusisprovidedforcommercial
use only.
• Pumpisusedfornon-ammableandammableliquidsfrommobilevessels.
• Thepumpmayonlybeusedinareascoveredbytheapproval.Informationontheratingplatemust
beabsolutelyobserved.
• Thepumpmayonlybeusedtopumptheagreedliquids.(contractdatasheet)orensurethatthe
pumpisresistanttotheliquidbeingpumped( technical data, Lutzresistancetable).
7
0698-451 B70H - 11/2022
en
• Notethelimitvaluesfortemperatureandviscosityoftheliquidbeingpumped(technicaldata).
• Thepumpmayonlybeoperatedwiththedischargeclosed,ifabypassvalvewithreturnlinehas
been installed.
• Ensurethatthesafetyvalvesfortheprotectionofthepumpagainstinadmissibleincreaseofpressure
are not higher set than the maximum operating pressure (technicaldata).
For the protection of the pump sealing the pump is not allowed to run dry. This must be permanently
controlled by the operator.
If the product and supplied accessories are used for other purposes than the intended purpose, it is the
responsibilityoftheusertocheckthesuitabilityandadmissibility.Productusenotconrmedinwriting
bythemanufacturerabsolvesthemanufacturerofanyliability.
Themanufacturerisnotliableforconsequencesofincorrecttreatment,use,maintenance,servicingand
operationoftheappliance,aswellasnormalwearandtear.Thesameappliesiffaultsarisefromintervention
orcongurationsonthepartoftheusernotconrmedbythemanufacturer.
2.2.1 Technical data
Pump size
12.1 25.1 25.2 50.1 75.1
Operatingpressureupto(bar)* 6 8 10 8 8
Flowrateupto(l/min)* 12 25 25 50 75
Viscositymax.(mPas) 100000
Medium temperature max.
(°C)withdierentstator
materials
NBR light 80
FPM 140
PTFE 140
PTFE Ex 100
Ambienttemperature(°C) -20 up to 40
Speedmax.(rpm) 900
*Themaximumowrateisavaluedeterminedbymeansofatestbenchandmeasuredwithwateratamedium
temperature of approx. 20°C. The measurement is carried out at the pressure joint of the pump, without hose,
nozzleorowmeter.Theowrateachievableinuseisloweranddependsontheindividualapplication,themedia
propertiesandthecongurationofthepump.Themax.deliveryheadisalsodependentonthepumpdesign,
motor and medium.
Part Material
Outertube,rotoranddriveshaft SS 1.4571, 1.4404
O-rings EPDM, FPM, NBR
Mechanical seal Carbon / CrMo casting,
alternatively:SiC/SiC,WoC/SiC,WoC/WoC
Stator PTFE, NBR, FPM
8
0698-451 B70H - 11/2022
en
2.2.2 Operation in hazardous location or pumping ammable liquids
! DANGER
Danger of explosion when using in explosion hazard area
Theclassicationofammableliquidsismadeaccordingtoregulation(EC)1272/2008(CLP).Whenpumping
ammableliquids,theoperationalsafetyregulationandthefollowingpointshavetobeobserved:
Theoperatormustcreateanexplosionprotectiondocumentforhiseldofapplication.Thisdocument
mustindicatethedivisionoftheexplosiveareaintozones.Onlydevicesofcategory1maybeusedin
areasofzone0anddevicesofcategory1or2inareasofzone1.
iThepumpsareusedtopumpliquidproductsfrommobilevessels.Thepumpcorrespondsto
category 2 when used as intended.
Only use pumps with ATEX/UKEx-marking.
• Onlyoperatethepumpinlledcondition.
• Onlyuseexplosion-proofdrivemotors.Selectmotorssuitablefortherespectivesizewithapowerofupto
2 kW and a maximum speed of 1000 rpm.
• OnlypumpammableliquidsofexplosionprotectiongroupsIIAandIIBand,dependingonthemarking,
temperature classes T1 to T4.
The maximum ambient temperature must not be exceeded.
In case of marking II -/2 G Ex h IIB T4 Gb: -20 up to +40 °C
In case of marking II -/2 G Ex h IIB T3 Gb: -20 up to +60 °C
The pump may only be installed horizontally.
Pump may not be used stationarily.
The maximum medium temperature of 100 °C must not be exceeded.
Only use stators made of PTFE.
• Theoperatormustcontinuouslymonitorthepumpduringoperationto preventthepumpfrom
pumpingagainstaclosedshut-odeviceandthuscausingtheuidremaininginthetanktoheatup
toimpermissiblelevels.Ifthiscannotbeprevented,abypassvalvewithreturnlinemustbeinstalled.
• Installthepumpwithoutrunpieceinclinedupwardsormountacheckvalveontheoutrunpieceinclined
downwards,topreventthetankfromdrainingandalsofromdryrunning(chapter5.1).
• Pumpoperationmaycausetheowinguidstopickupanelectrostaticcharge.
9
0698-451 B70H - 11/2022
en
• Beforestartingup,thepumpmustbeintegratedintotheequipotentialbonding,i.e.equipotential
bondingofthepumptubewiththetank,equipotentialbondingofthemotorwiththetankorwith
thepumptubeifpumptubeanddrivemotorarenotconductivelyconnectedwitheachother.The
containermustbegroundedseparatelyifnotalreadygivenbythetypeofinstallation.Establish
equipotentialbondingbetweencontainertobeemptiedandlled,e.g.withearthingleador
byconductivegroundwhichisconductivelyconnectedwithbothcontainers.Ifnecessary,other
accessoriesmustalsobeintegratedtotheequipotentialbonding(Fig.1).
Fig. 1
Legend:
(1)Equipotentialbondingcable,(2)explosion-proofconnector,(3)conductivehose,(4)conductive
substrate,(5)conductiveconnectionfromhosetohoseconnector,(6)pumptubeforzone1,(7)
explosion-proofmotorforzone1,(8)earthpotential,(9)suitablecontainerforusingammableliquids
10
en
0698-451 B70H - 11/2022
• Incaseatrolleyisused,itmustbeequippedwithconductivewheelsandmustbeincludedtothe
equipotentialbonding,togetherwithpumptubeanddrivemotor.Theconductivewheelsmustbekept
clean.
The hose line connected to the pump’s pressure joint may not exceed a resistance of 106Ωbetweenthe
endttings.ThehoselinemustbecheckedandmarkedaccordingtoDINEN12115.
• Thebearing/sealmustbeprotectedagainstraremalfunctions.Thisprotectivemeasureconsistsof
llingtheinsideofthepumpwithuid.Theoperatormustcontinuouslycontrolthepumptoprevent
raremalfunctionsandsimultaneouslyexplosiveatmosphere.
• Thepumpmustnotbeusedunattended.Dryrunningresp.idlingofthepumphastobeprevented.
During operation, the pump must be completely outside the container.
• Provideamotorprotectionandanon/oswitchagainstautomaticallystartingthepumpwheninserting
the plug.
Electric connection in explosion hazard areas only with explosion proof plug or explosion proof terminal
box.
• Themaintenanceintervalsoftheballbearingsmustbeobserved( chapter 8, maintenance and
servicing).
When assembling / disassembling the pump tube to / from the motor, check the coupling and the
synthetic ring for wear and replace, if necessary (Fig.2).
• OnlyusemechanicalsealsprovidedbyLutzPumpenforthispump
when used in hazardous areas.
Only motors and mechanical seals may be used which are suitable
foroperationintherespectivedirectionofrotation.
Fig. 2
11
0698-451 B70H - 11/2022
en
Prevention of obvious misapplication (examples)
• Observeandcomplywiththeoperatinglimitsofthepumpconcerningtemperature,pressure,
deliveryrate( contract data sheet, technicaldata).
• Thepowerconsumptionofthepumpincreaseswithincreasingviscosityoftheliquid.Topreventan
overloadofthepump,couplingandmotor,complywiththepermissibleviscosity(technicaldata).
Alowerviscosityisallowed.
Motors may only be operated mounted to the pump tube (operatinginstructionsmotor).
Use hoses only in perfect and tested condition (operatinginstructionshoselines).
2.3 Specic danger
Explosion hazard area
Chapter2.2.2-Operationinhazardouslocationorpumpingammableliquids
• OnlyusepumptubeswithATEX/UKExapproval.
• Onlyuseexplosion-proofdrivemotors.
Dangerous media
• Whenpumpingdangerousmedia(e.g.hot,ammable,explosive.poisonous,dangeroustohealth)
observesafetyregulationsforhandlinghazardoussubstances.
Consider the safety data sheet of the product.
• Alwayswearprotectiveequipmentwhenworkingonthepump.
Mechanical hazard
• Pumpprotrudesfromthecontainerandmustbeprotectedagainstmechanicalinuences.
12
0698-451 B70H - 11/2022
en
3. Con guration and function
3.1 Marking
Rating plate
Ratingplatepumptube(example)
1 Pump type
2 Serial number of the pump
3 Yearofconstructionofthepump(lasttwodigitsoftheserialnumbere.g.-22for2022)
4 CE-marking
Ratingplatepumptubeforexplosionhazardareas(example)
1 Pump type
2 Serial number of the pump
3 ATEX/UKEx-marking
4 Yearofconstructionofthepump(lasttwodigitsoftheserialnumbere.g.-22for2022)
5 CE-marking
13
en
0698-451 B70H - 11/2022
3.2 Conguration
Each Lutz eccentric screw pump of series B70H comprises a 3-phase or a compressed air motor and a
pumptube.Theowrateanddeliveryheaddependontheselectedpumpsize.Thismeansthatthemost
appropriatepumpcanbechosenforeachindividualapplication.
Drive units for type B70H
Three-phase drives
ForseriesB70Hseveralthree-phasemotorsareavailable:
Operating instructions for three-phase motors
Three-phase drives with frequency converter
Tooptimallyadjustthevolumeowanddesiredpumpingheadofaneccentricscrewdrumpump,three-
phasemotorswithattachedfrequencyconverterareavailable.
Operating instructions for three-phase motors
NOTICE
High leakage current!
Aradiointerferencelterinthefrequencyconvertercausesadditionalleakagecurrentthroughtheearth
conductor.
Theearthleakagecurrentcanbebetween3.5and11mAdependingontheclockingfrequency.
Compressed air drives
Recommended speed 200-900 1/min.
Operating instructions for compressed air motors
3.3 Function
Aneccentricscrewpumpisusedforfastandsafeemptyingortransferringalltypesofliquidsfrommobile
containers.Thepumpisconnectedwiththecontainerviatheclampsocketwithahoseorpipeline.
14
en
0698-451 B70H - 11/2022
4. Transport and storage
4.1 Transport
Unpackingandcheckingconditionofdelivery
Unpack the pump tube on receipt and check for transport damages.
Report transport damages to the manufacturer immediately.
Check that the consignment is complete as ordered.
! WARNING
Stator sleeve may release from the pump tube and fall on people
nearby!
After each transport, the clamping connection has to be checked
(Fig.3)forstrength.
4.2 Storage
! WARNING
Danger of injury and intoxication when handling hazardous
liquids!
Alwayswearprotectiveequipmentwhenworkingonthepump.
Complete emptying of pump tube.
Store pump at a protected place.
5. Installation/Assembly and connection
! DANGER
Danger of injury and intoxication when handling hazardous
liquids!
Valvespoolonthecontainermayonlybeopenedifpump,hose
andshut-ovalveareprofessionallymounted.Whenstartingup,
ensure leak tightness.
! WARNING
Danger of injury due to rotating stator!
Do not start the pump without or with incorrectly mounted stator
sleeve(chapter8.3).
Fig. 3
15
en
0698-451 B70H - 11/2022
! WARNING
Danger of injury at the openings of the pump - limbs can be
pulled in!
Do not grip into the openings of the pump when the power
supply is connected (Fig.4).
In case of malfunction or incomprehensible downtime, always
disconnect the pump from the power supply.
! WARNING
Persons can fall over the pump, hose line, grounding cable or
wiring!
Positionthepumpandtheaccessoriesvisiblyforallpersonsor
cordonoasucientareaaroundthepump.
5.1 Assembly B70H
3 Motorisswitchedo
3 Ashut-odeviceisavailableonthecontainer
! WARNING
Risk of injury by crushing!
When mounting the motor on the pump tube, hold the motor
insuchawaythatnolimbscanbesqueezedbetweenthemotor
and the pump tube.
Thedrivemotorisconnectedtothepumpvia/usingfourscrews.Use
theboresintheange(Fig.5).
Before assembly the jaw-type coupling must be adjusted at
motor and pump side (Fig.6-Item1).
Mounting pump tube on the motor (Fig.6,item2).
Fig. 4
Fig. 5
Fig. 6
16
en
0698-451 B70H - 11/2022
Whenusedinexplosionhazardareasorwhenpumpingammableliquids,thepumpmustbe
mountedwithanupwardlyinclinedpumpoutlettopreventaccidentalemptyingofthecontainer(
Fig.7a,b,c).Iftheorientationofthepumpoutletdoesnotmatch,loosenthelocknutandslightly
turn the pump tube. Then tighten the locknut again (Fig.7d).Alternatively,youcanmounta
checkvalveatthepumpoutlet.
Tighten screws (Fig.8).
Connect pump and container with suitable hoses.
5.2 Electrical connection of three-phase motors
! DANGER
Live mains connection!
Electric shock can kill you.
Theelectricalconnectionmayonlybecarriedoutbytrainedqualied
personnel.Followingregulationsmustbeobserved:
All works must only be carried out when the motor is de-
energized. Protection switch must be set to OFF-position.
Mainsvoltageandfrequencyareasspeciedontheratingplate
(Fig.9).
Dimension of the connecting cable must be adjusted to the
nominal current.
The insulation of the connecting cable must be adjusted to the
environmentalconditions.
Fig. 8
Fig. 7
Fig. 9
17
en
0698-451 B70H - 11/2022
NOTICE
Incorrect rotating direction may damage the mechanical seal and lead up to leakage!
For pumps with clockwise rotating direction-dependent mechanical seals (Fig.10),motor’sdirection
of rotation must correspond to the direction of rotation arrow (Fig.11).Reconnectthemotoras
necessary.
5.3 Operating a three-phase motor with attached frequency converter
Default setting:
Button Start starts the pump
Button Stop stops the pump
Button (reverserotatingdirection)withoutfunction
Button IactivatesmodeI„Pumping“
Button IIactivatesmodeII„Emtying“
Button Reset resets the pump in case of malfunction
Speed controller
(Potentiometer)formanual
speed adjustment
Pumping
Rotating to the right
Targetvaluesetat
potentiometer
(10-50Hz)
Emptying
Rotating to the left
Fixed speed 5 Hz
(optionally without
functionor10-50Hz)
Fig. 10 Fig. 11
18
en
0698-451 B70H - 11/2022
5.4 Mechanical loads on the pump tube
Thepumptube’sfunctioningandservicelifeareimpairedwhen
deformed by mechanical loads. For this reason, the outlet must not
besubjectedtocompressiveortensileforces.
The bending moment MB at the outlet must not exceed 50 Nm (
Fig.12).
Avoidingoverloadofadapterandmotorbysupportingthepump
tubebetweenoutrunpieceandstatorsleeve(Fig.18).
6. Operation
3Allconnectionsandttingsareproperlytightened.
! WARNING
If connections are not properly or not at all tightened:
- it can come to splashing medium.
- itcancometoyingparts.
- thepumpmaystartmovinginanuncoordinatedmanner.
! WARNING
Danger of injury and intoxication when handling hazardous
liquids!
Alwayswearprotectiveequipmentwhenworkingonthepump.
Whenpumpingdangerousmedia(e.g.hot,explosive,poisonous,
dangerousto health)observesafetyregulationsforhandling
hazardous substances.
6.1 Suction funnel
Highlyviscousliquidsmustbeabletoowquicklyenoughto
preventtheformationofsuctionfunnels(Fig.15).
Fig. 12
Fig. 15
Fig. 18
19
en
0698-451 B70H - 11/2022
6.2 Direction of ow
Depending on the built-in mechanical seal, the pump can be operated in one or both directions.
Thedirectionofrotationofthemotordeterminestheconveyingdirectionofthepump(clockwise Fig.
13, counter-clockwise Fig.14).
6.3 Dry running
Thepumpissaidtorundryifitcontinuestooperatewithoutpumpinganyliquidwhatsoever.Dry
runningmustbeavoided.Thiscanbeensuredbyremaininginattendanceorwiththeaidofsuch
technicalmeansasaowmonitor,etc.
6.4 Operation with closed discharge
! DANGER
Injury by ying parts!
TheeccentricscrewpumpB70Hisapositivedisplacementpump.Thepumpmustnotbeoperatedwith
closedshutoelements,suchasnozzle,valve,etc.Thegeneratedoverpressurecanleadtodamages.Make
sure that the maximum pressure will not be exceeded (technicaldata).
6.5 Malfunction
! WARNING
Pinching by rotating parts!
In case of malfunction or unreproducible downtime, disconnect the motor from the mains before repair
work is carried out.
Fig. 13 Fig. 14
20
en
0698-451 B70H - 11/2022
7. Taking out of operation
! WARNING
Danger of injury and intoxication when handling hazardous liquids!
Alwayswearprotectiveequipmentwhenworkingonthepump.
Collectanyresidualleakinguidsfromthepumpsafelyanddisposeofitinanenvironmentallyfriendly
fashion.
8. Maintenance and servicing
! WARNING
Danger of injury and intoxication when handling hazardous liquids!
Alwayswearprotectiveequipmentwhenworkingonthepump.
Complete emptying of pump tube.
8.1 Lubrication
NopartsoftheB70HLutzeccentricscrewpumpneedtobelubricatedatshortintervals.
The rolling bearings of the motor and the pump tube should be replaced after 8000 hours or 2 years of
operation. Exchange the lip seals of the bearing unit as well. Note the recommendation for lubricant in
the spare-parts list of the manufacturer.
8.2. Repairs
Thepumpmustbeswitchedoandrepairedimmediatelyifliquid
leaks out at the leakage port (Fig.16).
Repairs should only be made by the manufacturer or authorized
Lutz dealers.
Only use original Lutz Pumpen spare parts. If other spare parts are
used, liability on the part of Lutz Pumpen is obsolete.
Settingvaluesofthemechanicalsealmustbestrictlyadheredto
as this may result in impermissible heating.
iPlease refer to www.lutz-pumpen.de for the addresses of our
worldwide agencies and sales partners.
Fig. 16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Lutz Eccentric screw pump B70H Industry Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI