Troubleshooting and Testing Procedures (cont.)
The 7 segment clock display is also used to aid with error codes that can occur. It will shut off after
3 minutes of no button activity. To wake up the display, simply press any button.
5. Displayed Error Codes are as Follows:
OVER LOAD:
Willbedisplayedbyashing“LoAd”ontheclockdisplay.If
this condition occurs, the Power Pack will Auto reset 3 times
andifOverLoadconditionstillexists,itwillshutoffand
continueashing“LoAd”.Toresolvethis,tryandndthe
defective light or remove some of the lights to lower the load.
Shorted underground wiring, usually at a distance away, can
also cause this, but it will generally trip the Over Load condition
faster than too many lights on one circuit will.
SHORT CIRCUIT:
Will shut down the Power Pack within a few seconds upon
poweringonanditwillash“Shrt”onthedisplay.Check
for faulty wiring, frayed wires near the +/- terminal block
or defective LED bulb. Isolate short. Reset by unplugging
the AC cord, wait 5 seconds and reconnect. Power on unit.
IfShortcircuitdoesnotexist,continue.Iffaultreturns
again, isolate the bad wiring or faulty LED bulb.
BAD POWER SUPPLY:
Willbedisplayedbyashing“dbPS”ontheclockdisplayonly
upon power on and when 0 volts output detected. If this condition
occurs, remove all landscape wiring from output terminal block,
remove AC power cord, wait 5 seconds to reset and if message
stillexistthenwillrequireservice.
FLASHING 12:00:
Will be displayed when system has not been programed, or
when battery level is too low. Press and hold the clock button
While selecting up/dn arrow to adjust to local time setting. After
1 hour plugged into AC power, the battery will be charged.
FAN MONITOR:
If fan is obstructed, there will be 3 attempts to unjam the fan
from insects or possible plant growth entering the rear vents.
ThePowerPackwillshutoffandash“FAn”.UnplugtheAC
cord and inspect rear vents. Plug in the AC power cord and try again.
6. ElectricalSpecications:
1-1: USAInputvoltage:120VAC+/-10%50-60Hz•EuroInputvoltage:220-240VAC+/-10%50-60Hz.
1-2: OutputDCvoltage:(MAX)13.3VDC+/-5%variabledimerto8.5VDC+/-2%(MIN)
1-3: MaximumDCAMPS12.5continuous
1-4: Overload trip @ 17-19 amps from 3-15 minutes
Operating Instructions