RAM-6021M12

Sixnet RAM-6021M12, RAM, RAM-6021 User manual

  • Hello! I am an AI chatbot trained to assist you with the Sixnet RAM-6021M12 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Red Lion
®
RAM
®
6021 & RAM
®
6021M12
Hardware Guide | May 2018
Industrial Wired Routers
LP1068A
©2018RedLionControls,Inc.Allrightsreserved.RedLion,theRedLionlogoandSixnetareregisteredtrademarks
ofRedLionControls,Inc.Allothercompanyandproductnamesaretrademarksoftheirrespective owners.
Red Lion Controls, Inc.
20 Willow Springs Circle
York, PA 17406 USA
CONTACT INFORMATION:
Inside US: +1 (877) 432-9908
Outside US: +1 (717) 767-6511
Website: www.redlion.net
RAM-6021 and RAM-6021M12 Hardware Guide i
Table of Contents Revised 2018-05-15
Drawing No. LP1068A
TableofContents
Prefaceiii
Disclaimer ............................... ................................... .................... iii
Purpose ............... ...................................................................... .... iii
Audience .................................. ................................... .................. iii
ComplianceStatements,Certifications&UserInformation .................. .................... iii
FCCComplianceStatement .........
............... ............................................... iii
UserComplianceInformation ....................................
............................... .. iv
CanadianComplianceStatement..............
.................................. .................. iv
RegulatoryInformation .............................. ................
............... ............. iv
ProductSafety............... .....
............................................................. iv
Emissions.......................................
............................... ................v
Immunity...
.................................. ................................... ..............v
Rail.................
............... ...........................................................v
DesignedInCompliance.........................
.................................................v
Other .
.................................................................................... .....v
TrademarkAcknowledgments .................... ................................... .............v
ReleaseNotesandDocumentUpdates .................................. .........................v
PublicationHistory ............... ............................................................... vi
RelatedDocuments .............................. ................................... ............ vi
DocumentComments .................... ................................... .................... vi
AdditionalProductInformation ............... .................................................. vi
SafetyInformation .............. ................. .. ................................... .......... vi
Warnings/Cautions/Notes ................ ................................... .................... vi
HazardousLocationandInstallationRequirements ..............................................vii
AVERTISSEMENTSPOURINSTALLATIONETENDROITSDANGEREUX ............... ...............vii
ProductOverview........................ ................................... ......................11
ProductHighlights .............................................. ...............................11
RAM
®
6021/RAM
®
6021M12 ............................................. ......................11
RAM6021Specifications..............................
.................................. .......12
RAM6021FeaturesandBenefits ...
.................................. ............................12
RAM6021GeneralSpecifications.. ...............................
...............................13
RAM6021Dimensions...............
............... .................... .......................14
RAM6021PowerConnectorsandPinOuts............... ....................
.....................15
RAM6021PowerSpecifications ........................
............................... ...........15
RAM6021ElectricalSpecifications...
............................................................16
RAM6021FrontView ............ .......................
.......................................16
RAM6021InputandOutputConnectors....
............... ................. ......................1 7
RAM-6021 and RAM-6021M12 Hardware Guide ii
Table of Contents Revised 2018-05-15
Drawing No. LP1068A
RAM6021Indicators ............................ ................. ..............................17
RAM6021RESETButton ..................
.................................. ....................18
RAM6021M12Specifications ......... .........................................................19
RAM6021M12FeaturesandBenefits .......... ...................
............................... .19
RAM6021M12Specifications ..............
.................................. ...................110
RAM6021M12Dimensions................................. ...........
........................111
RAM6021M12FrontView ................ ......
............... ................................112
RAM6021M12Power
ConnectorandPinOuts............... ................................... ..112
PowerSpecifications. ................. .........................
...............................112
RAM6021M12ElectricalSpecifications...............
...........................................113
RAM6021M12InputandOutputConnectors.
............................... .....................114
RAM6021M12IndicatorLights............................................
............... ......115
RAM6021M12RESETButton .........................
............... ................. ..........115
OrderingGuide ....................................................... ........................116
HardwareInstallation ......................................................................... ..217
MountingtheRAM6021WiredRouter ............. .................... ................. .....217
DINRailMounting&Removal........................................
............... ...........217
EthernetCable......................
............... .................... ......................218
USBCable........................... .. .............
............................... ..........218
SerialCable .......
...........................................................................219
PowerSource.......................
............... .................... .............. ........219
PoweringtheRouter.........................................
............................... ..220
Testi ngthePowerConnection.............
.................................. ...................220
MountingtheRAM6021M12WiredRouter ........................................ ...........221
RAM6021M12DIN‐RailMounting&Removal...........................................
.........221
RAM6021M12BulkheadMounting&Removal ...................................
.................221
EthernetCable............................. ..
.................................. ..............222
USBCable
................................................ ...................................223
I/OCable .. .. ...........
............... ................. ................................... ..223
SerialCable ..............................
............................... .....................223
PowerSource..................................... .........
............... .............. .....224
PoweringtheRouter.............
............... ................. .............................224
Testi ngthePowerConnection....................... .............
..............................224
ServiceandSupportInformation ..............................................................225
ServiceInformation ................ ................. ..........................................225
ProductSupport ........... ................. .................... ..............................225
StatementofLimitedWarranty...... .. ........................................................227
RAM-6021 and RAM-6021M12 Hardware Guide iii
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
Preface
Disclaimer
Portions of this document are intended solely as an outline of methodologies to be followed during the
maintenance and operation of the RAM-6021 equipment/software. It is not intended as a step-by-step guide or a
complete set of all procedures necessary and sufficient to complete all operations.
While every effort has been made to ensure that this document is complete and accurate at the time of release, the
information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or
alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic
conditions. This document is intended as a general guide only. It has not been tested for all possible applications,
and it may not be complete or accurate for some situations.
Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as
electrical hazard warnings.
Purpose
This manual gives specific information on how to install and connect the Red Lion RAM-6021 and RAM-6021M12
routers. The RAM-6021M12 model is a RAM-6021 router with in a rugged IP67, dust-proof and water resistant
metal enclosure designed to withstand harsh environments.
Audience
The manual is intended for use by qualified personnel who are responsible for installing and maintaining network
equipment in an industrial environment.
Co mplianceSt atem ents,Certificatio n s &UserIn fo rmatio n
FCCComplianceStat em en t
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
This equipment generates uses and can radiate radio frequency energy; and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
RAM-6021 and RAM-6021M12 Hardware Guide iv
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in
which case the user will be required to correct the interference at their own expense.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Avertissement: Tout changement ou modification apporté à cette unité et non expressément approuvé par
la partie responsable de la conformité pourrait annuler l'autorisation d'utilisation de
l'équipement.
Per FCC requirements the antenna gain including cable loss must not exceed 7.5 dBi in the cellular band, 3 dBi in
the PCS band, 5.5 dBi for LTE Band 4, and 9 dBi in the LTE Band 17 for RF exposure purposes of 2.1091. The
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all
persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter except in accordance with FCC multi-transmitter evaluation procedures
UserComplianceInformation
If this equipment causes interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
In order to meet FCC emissions limits, this equipment must be used only with cables that comply with IEEE 802.3.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional
suggestions.
The user may find the following booklet prepared by the Federal Communications Commission helpful:
“How to Identify and Resolve Radio-TV Interference Problems”.
This booklet is available from: U.S. Government Printing Office, Washington DC, 20402 Stock No. 004-000-00345-
4.
CanadianComplianceSta tement
This Class A digital apparatus meets all requirements of the Innovation, Science and Economic Development
Canada ICES-003.
Cet appareil numérique de la classe A respecte toutes les exigences de la science, l'innovation et de
Développement économique Canada ICES-003.
RAM-6021 and RAM-6021M12 Hardware Guide v
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
RegulatoryInforma tion
ProductSafety
RAM6021
ANSI / ISA12.12.01/CSA22.2/213 (CUL) Class I, Div. 2, Groups A, B, C, and D Hazardous Locations
UL508/CSA22.2/142 (CUL), (CE) - IEC61010-1 Electrical Safety
Pollution Degree 2 and Overvoltage Category II
RAM6021M12
ANSI/ISA 12.12.01-2015 Class I and II, Div. 2 and Class III, Div. 1 and 2, Groups A, B, C and D Hazardous
Locations
UL508 17th Ed. Industrial Control Equipment
CAN/CSA-C22.2 No. 213-16 Class I Div. 2 Hazardous Locations
CAN/CSA-C22.2 No. 14-13 Industrial Control Equipment
Emissions
RAM6021
EN55022, FCC Title 47, Part 15, Radio Frequency Devices, Subpart B; Industry Canada ICES-003
RAM6021M12
FCC Title 47, Part 15, Radio Frequency Devices, Subpart B ANSI C63.4-2014; Industry Canada ICES-003,
EN 61000-6-4, EN 61000-3-2, EN61000-3-3
Immunity
RAM6021
ETSI EN 301 489-7 and -24 (Includes EN61000-4-2, 3, 4, 5 and 6)
RAM6021M12
EN 61000-6-2; IEC 61000-4-2 (ESD); IEC 61000-4-3 (RFAM); IEC 61000-4-4 (EFT); IEC 61000-4-5 (SURGE);
IEC 61000-4-6 (RFCM); IEC 61000-4-8 (PFMF); IEC 61000-4-11 (VDI)
Rail
RAM6021M12
EN 50155, EN 50121, EN 61373 and EN 45545-2
RAM-6021 and RAM-6021M12 Hardware Guide vi
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
DesignedInCompliance
RAM6021M12
IEEE 1613 (Electric Utility Substations), NEMA TS1/TS2 (Traffic Control)
Other
RAM6021
RoHS Compliant
WEEE Compliance- These devices comply with the WEEE directive. Do not throw away these devices in the
standard trash. Contact Red Lion Controls with questions regarding proper disposal.
RAM6021M12
EMC Directive 2014/30/EU; LV Directive 2014/35/EU, Restriction of Hazardous Substance 2011/65/EU, RoHS
Compliant, ABS Type Approval for Shipboard Applications.
WEEE Compliance- These devices comply with the WEEE directive. Do not throw away these devices in the
standard trash. Contact Red Lion Controls with questions regarding proper disposal.
TrademarkAcknowledgments
Red Lion Controls acknowledges and recognizes ownership of the following trademarked terms used in this
document.
Windows
®
/98/2000/7/8, Windows XP
®
are registered trademarks of the Microsoft Corporation.
Microsoft is either a registered trademark or trademark of Microsoft Corporation in the United States and/or
other countries.
Ethernet
TM
is a registered trademark of Xerox Corporation.
All other company and product names are trademarks of their respective owners.
ReleaseNote sandDocumen tUpda te s
The hard copy and flash drive versions of this document are revised only at major releases and, therefore, may not
always contain the latest product information. As needed, Tech Notes and or Product Bulletins will be provided
between major releases to describe any new information or document changes.
The latest online version of this document and all product updates can be accessed through the Red Lion web site
at www.redlion.net/documentation
RAM-6021 and RAM-6021M12 Hardware Guide vii
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
PublicationHist ory
The following information lists the release history of this document.
RelatedDocuments
The following information lists available documents related to this product.
DocumentComments
Red Lion appreciates all comments that will help us to improve our documentation quality. The user can submit
comments through the Red Lion Customer Service. Simply email us at customer[email protected]
.
AdditionalProductInformation
Additional product information can be obtained by contacting the local sales representative or Red Lion through the
contact numbers and/or e-mail addresses listed on the back of the cover.
Saf e ty Information
Warnings/Cautions/Notes
Warnings apply to situations where personal injury or death may result.
Mises en garde s'appliquent aux situations où les risques de blessures graves ou mortelles peuvent en résulter
Cautions apply where damage to equipment may result.
Les mises en garde s'appliquent dans le cas où les dommages matériels peuvent en résulter
Issue/Revision Release Date Content Description
Revision A May 2018
Applied formatting updates and standardized content. Added
RAM-6021M12 model.
Initial Release April 2014
Modifications to power specifications. Included installation and
hazardous area warnings.
Issue/Revision Release Date Document Title
LP0979 Revision C September 2017 RAM-6021 Software Manual
LP1043 Revision A September 2017 RAM-6021 Quick Start Guide
LP1061 Revision A February 2018 RAM-6021M12 Quick Start Guide
WARNING – Must consult the guide in all cases where this symbol is marked.
AVERTISSEMENT - Doivent consulter le guide dans tous les cas où ce symbole est marqué.
RAM-6021 and RAM-6021M12 Hardware Guide viii
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
Notes apply where additional noteworthy information, not in the general text flow but applicable, is made available
to the user.
Notes s'appliquent lorsque des informations dignes de mention, non pas dans l'enchaînement du texte mais il y a
lieu, est mis à la disposition de l'utilisateur
HazardousLocationandInstallationRequirements
These products should not be used to replace proper safety interlocking. No software-based device (or any other
solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or
personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential,
that result from the use of this equipment in any application.
All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in
accordance with the authority having jurisdiction. Suitable for use in Class I, Division 2, Groups A, B, C and D
hazardous locations, or non-hazardous locations only.
AVERTISSEMENTSPOURINSTALLATIONETENDROITSDANGEREUX
Ces produits ne doivent pas être utilisés pour remplacer le verrouillage de sécurité approprié. Aucun dispositif
basé sur un logiciel (ou tout autre dispositif à l'état solide) devraient jamais être conçus pour être responsable de
l'entretien de l'équipement consécutifs ou la sécurité du personnel. En particulier, Red Lion décline toute
responsabilité pour les dommages, directs ou indirects, résultant de l'utilisation de cet équipement dans n'importe
quelle application.
Tout pouvoir, le câblage d'entrée et de sortie (I/O) doivent être conformes aux méthodes de câblage de Classe I,
Division 2 et conformément à l'autorité compétente. Cet équipement est adapté pour une utilisation en Classe1,
Division 2, Groupes A, B, C et D ou endroits non-dangereux
seulement.
WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I,
Division 2.
AVERTISSEMENT - Risque d'explosion - La substitution de tout composant peut nuire à la
conformité de Classe 1, Division 2.
Warning – Do not remove or replace port connections while circuit is live unless the area is
known to be free of ignitible concentrations of flammable substances. For the required marking for
the port connections, instruction shall be included indicating that the marking shall be displayed
on a prominent place on the end-enclosure..
AvertissementNe pas retirer ou remplacer les connexions de port alors que le circuit est vivre à
moins que la région est connue pour être libre d'ignitible les concentrations de substances inflam-
mables. pour le marquage obligatoire pour les connexions de port, l'enseignement doit être inclus
en indiquant que le marquage doit être affichée sur une place de premier plan dans l'enceinte.
WARNING – Explosion Hazard – Do not disconnect equipment unless power has been switched
off or the area is known to be non-hazardous.
AVERTISSEMENT - Risque d'explosion - Ne débranchez pas l’équipement à moins que l’ali-
mentation ait été coupée ou que l’environnement est connu pour être non dangereux.
RAM-6021 and RAM-6021M12 Hardware Guide ix
PREFACE REVISED 2018-05-15
D
RAWING NO. LP1068A
RAM6021M12ModelOnly
These devices are open-type devices that are to be installed in a tool only accessible enclosure suitable for the
environment.
T-Code of T4A was established
Ces appareils sont de type ouvert matériels qui doivent être installés dans un boîtier de l'outil accessible
uniquement adapté à l'environnement
T-Code de T4A a été établie.
WARNING – DC 2.5mm Barrel Connector shall not be used in hazardous locations.
AVERTISSEMENT - Connecteur 2.5mm DC ne doit pas être utilisé dans des endroits dangereux.
RAM-6021 and RAM-6021M12 Hardware Guide 1-1
Product Overview Revised 2018-05-15
Product Highlights Drawing No. LP1068A
Chapter1 ProductOverview
With a rugged design and flexible platform, the RAM-6021 industrial secure router provides the ability to remotely
connect, monitor and control assets across a variety of industrial applications. The RAM-6021’s web based event
engine can be customized to trigger I/O or email alerts, to quickly notify personnel of critical events based on
operational data. Add in robust security features, which include a stateful firewall, NAT translations and VPN
connections, and the RAM-6021 delivers a compact all-in-one solution that seamlessly connects to existing
Ethernet infrastructures, including networks with Modbus and DNP3 enabled devices.
The router is also available as a RAM-6021M12 industrial secure model with an IP67 rating.
The RAM-6021M12 industrial LAN router offers secure routing, VPN tunneling and NAT (network address
translation) for secure LAN to LAN and LAN to WAN communication. Housed in a rugged IP67, dust-proof and
water resistant metal enclosure, the RAM-6021M12 is designed to withstand harsh industrial environments
including temporary immersion in water, exposure to low/high pressure water jets, and extreme shock and vibration
levels, making it ideal for industries where hardened products are required.
1.1ProductHighlights
1.1.1RAM
®
6021/RAM
®
6021M12
Secure network routing and communication
LAN-to-LAN or LAN-to-WAN connectivity
Integrated security firewall provides intrusion protection
NAT support for 1-to-1 and 1-many translations
Native support for DNP3 and Modbus protocols
Powerful event engine to trigger I/O or send email alerts based on real-time operational data.
Rugged industrial design in a compact package
IP67 rated, dust-proof and water resistant, hardened metal enclosure*
Bulkhead mountable*
* Denotes RAM-6021M12 only
RAM-6021 and RAM-6021M12 Hardware Guide 1-2
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2RAM6021
All specifications are subject to change. Consult the Red Lion Controls website for more information.
1.2.1RAM6021FeaturesandBenefits
Features and Benefits
Built-in security and routing protects against unwanted
intrusion
Intrusion protection and secure data access
Stateful firewall
Access Control List (ACL)
IPsec and SSL VPN tunnels
Port forwarding
Packet filtering
Flexible all-in-one platform reduces complexity
Remote TCP/IP based capabilities
Integrated switching and routing
Serial-to-IP conversion
Access IP and serial devises simultaneously
Redundant power inputs (8-30 VDC)
Rugged, compact design deploys easily in space-
constrained locations
-40 to 70 °C operating temperature range
Ingress IP30 protection
DIN-rail mounting
Remote monitoring and control eliminates site visits
Instant access to SCADA data
Modbus and DNP3 (serial and IP protocol support
Simple integration for complex configurations
Intuitive web-based interface simplifies management and
configuration
Syslog
Built-in data capture for enhanced troubleshooting
Key metric reporting
RAMQTT for cloud connectivity
RAM-6021 and RAM-6021M12 Hardware Guide 1-3
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.2RAM6021Specifications
Mechanical
Height Width Depth Weight Mount
4.70" (11.94 cm) 2.00" (5.08 cm) 3.77" (9.58 cm) 1.2 lbs (0.544 kg) 35mm DIN-Rail
Power Input
Input Voltage Steady Input Current Power Consumption Redundant Power Input
8-30 VDC 150 mA @30 VDC 4.5W typical max.with
all ports linked
4-pin screw terminal
Side mounted 2.5 mm barrel connector
8-30 VDC (nominal)
Input current (max): 150mA
Environmental
Operating
Temperature
Storage Temperature Operating Humidity Operating Altitude
-40 to 70 °C -40 to 85 °C 5% to 95% (non condensing) Up to 2000 m per
IEC61010-1
Shock and Vibration / Reliability
Shock Vibration MTBF
IEC 60068-2-27 IEC 60068-2-6 1,832K Hours GB @ 40˚C per MIL-HNDBK-
217F2
Network Media
10Base-T CAT3 Cable
100Base-TX CAT5 Cable
Recommended Minimum Wiring Clearance
Front 4” (10.16 cm)
Interfaces / Connectors
Ethernet 10/100 Auto-Sensing Serial USB I/O
5x RJ45 (port 5 – WAN/LAN capability) 1x RS-232 Serial DB9
115200bps
1x USB 2.0 mini
configuration port
1x digital output
1x digital/analog input
(one active)
Switch Properties
IP Protocol Gateway Tunneling Data Throughput
NAT, port forwarding, dynamic DNS, DHCP
Stateful inspection firewall, IP transparency
Routing Protocols: OSPF, BGP, RIP, VRRP
Encapsulation Protocols: GRE
Modbus RTU/TCP/
ASCII RTU
DNP3 - slave
IPsec and SSL
LAN ports: 100 Mbps
WAN port: 45 Mbps
RAM-6021 and RAM-6021M12 Hardware Guide 1-4
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.3RAM6021Dimensions
All specifications are subject to change. Consult the company website for more information.
RAM-6021 and RAM-6021M12 Hardware Guide 1-5
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.4RAM6021PowerConnectorsandPinOuts
1.2.5RAM6021PowerSpecifications
Power input to the router is protected against reverse polarity and power surges over 33VDC. The routers are
equipped with an internal 3 Amp fuse.
The router’s power consumption is:
Note: Wiring instructions are provided in Chapter 2.
Note: To meet UL requirements, a “Class 2 Source” power supply is required.
Power Input Connectors / Pin-outs
Model / Connector Pin Name Description
RAM-6021
4-Pin Screw Connector
1 GND Ground
2 PWR+ Power supply input (8 to 30 VDC)
(500mA@12VDC)
3 OUT Digital output
4 IN Digital and analog input
DC 2.5mm Barrel Connector
Sleeve GND Ground
Tip PWR+ Power supply input (8 to 30 VDC)
WARNING – DC 2.5mm Barrel Connector shall not be used in hazardous locations.
AVERTISSEMENT - Connecteur 2.5mm DC ne doit pas être utilisé dans des endroits dangereux.
MODEL
DRAW IN MA (AT 12 VDC)
STANDBY TRANSMITTING PEAKS
RAM-6021 115 360 531
RAM-6021 and RAM-6021M12 Hardware Guide 1-6
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.6RAM6021ElectricalSpecifications
1.2.7RAM6021FrontView
1x Digital Output (DOUT)
Configuration Open collector, reference to ground
Absolute Maximum IDC
500mADC(Vce=750mVDC)
Absolute Maximum VDC
30VDC(opencircuit)
Absolute Minimum VDC
‐0.4VDC(opencircuit)
1x Digital Input (DIN)
Configuration Un-isolated level detection, reference to ground
Active level
1.6VDCto30VDC
Inactive level
0VDCto1.3VDC
Absolute Minimum VDC
0.3VDC
Absolute Maximum VDC
33VDC
Leakage IDC at 5VDC
150uADC
1x Analog Input (Shared with Digital Input) (DIN/AI1)
Configuration
Unisolatedinput,referencetoground
Resolution
1024(ADC10bit)
VDC per step
4.8875855mVDC
Full scale level
5VDC
Zero level
0VDC
Absolute Minimum VDC
0.3VDC
Absolute Maximum VDC
8.3VDC
Leakage IDC at 5VDC
265.96uADCTYPE
RARAM-6021
RAM-6021 and RAM-6021M12 Hardware Guide 1-7
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.8RAM6021InputandOutputConnectors
1.2.9RAM6021Indicators
Input/Output Ports
Model / Connector Connector Type Name Description
RAM-6021
LAN/WAN Connector
RJ45 Ethernet port The router's 10/100Mbps Ethernet port
is compliant with the EIA-568 standard.
The router’s ports are auto-sensing so
they can be used with either a straight or
crossover RJ45 cable to connect to host
ports
RAM-6021
RS232 Connector
DB9 Serial port The router’s serial port is an RS232
DCE, compliant with EIA-232 standard.
The connector used is DB9 female.
RAM-6021
USB Connector
Mini B USB 2.0 interface port This is a USB 2.0 Device interface on a
Mini B connector. It offers Ethernet-over-
USB functionality using the RNDIS driver
for Windows XP and Windows Vista
Operating systems only. The BlueTree
RNDIS driver must be installed before the
USB interface can be used. The driver
and instructions can be obtained at
www.redlion.net
.
Note: With firmware version 4.17 and
later, standard Windows RNDS drivers
are used and no additional driver is
required from www.redlion.net
LED STATUS CORRESPONDING STATE
Power
ON Router is powered on.
OFF Router is powered off.
FLASH Firmware error
W (Reset) View section 1.2.8 for further details.
RS232
ON Link established with serial device but no data activity.
OFF Connection is not established.
*FLASH Data transmitted/received (* Depends on serial application)
Ethernet Link/
Activity
ON Link established with Ethernet device.
OFF Connection is not established.
FLASH Data transmitted/received.
RAM-6021 and RAM-6021M12 Hardware Guide 1-8
Product Overview Revised 2018-05-15
RAM-6021 Drawing No. LP1068A
1.2.10RAM6021 RE SETButton
MODE PATTERN DESCRIPTION
Hard reset Press and hold for less
than 3 seconds
Standard reboot
Factory restore Press and hold between
3 and 10 seconds
RS232 LED flashes
quickly
To restore default settings for older versions, rerun the SN
Reflashing procedure found at www.redlion.net
FW upgrade Press and hold between
10 and 15 seconds
W LED flashes quickly
Puts the router in advanced firmware upgrade mode by restarting
the router and running the boot loader only. Do not use this mode
unless instructed to by Red Lion Technical Support
RAM-6021 and RAM-6021M12 Hardware Guide 1-9
Product Overview Revised 2018-05-15
RAM-6021M12 Drawing No. LP1068A
1.3RAM6021M12
All specifications are subject to change. Consult the Red Lion Controls website for more information.
1.3.1RAM6021M12FeaturesandBenefits
Features and Benefits
Built-in security and routing protects against unwanted
intrusion
Intrusion protection and secure data access
IPsec and SSL VPN tunnels
Port forwarding
Stateful firewall
Packet filtering
Access Control List (ACL)
Flexible all-in-one platform reduces complexity
Remote TCP/IP based capabilities
SNMP V1, V2, V3
Serial-to-IP conversion
Access IP and serial devises simultaneously
Full IEEE 802.3 compliance
ESD protection on all ports
Redundant power inputs (8-49 VDC)
Surge protection on power inputs
Extended Environmental Specifications
-40 to 80 °C operating temperature range
Bulkhead mountable
Rugged compact IP67 hardened enclosure
IP67 protection
Protection against low/high pressure water jets
Temporary immersion in water
Dust proof
Remote monitoring and control eliminates site visits
Instant access to SCADA data
Modbus and DNP3 (serial and IP protocol support
ID routing to existing Modbus hardware
Intuitive web-based interface simplifies management and
configuration
Syslog
Built-in data capture for enhanced troubleshooting
Key metric reporting
RAMQTT for cloud connectivity
/