2-1. Electronics Troubleshooting Chart - E80
Malfunction Circumstance Inspection and Test Points Replacement
suggestions
Notes
No start up Exercise on the unit; display
shows no reaction.
1. Inspect all cable connections.
2. Inspect drive board fuse.
3. Inspect whether power indicator on the drive
board lights.
4. Inspect display program IC.
1. Fuse
2. Drive board
3. Display
No strides/min Exercise on the unit; display
shows 0 strides/min.
1. Inspect cable connections.
2. Inspect LED5 on the drive board.
A. Magnet or reed switch malfunction
B. Drive board malfunction
3. Inspect display board IC connections.
1. Reed switch
No resistance
adjustment
Press LEVEL <▲>/<▼>;
actual resistance does not
change.
1. If you press LEVEL<▲>/<▼> and values in
the display LEVEL screen do not change, key
switches are bad.
2. Inspect whether drive board LED3 or LED4
light. If not, inspect cable connections or replace
the drive board.
3. Test or replace the VR assembly.
1.VR assembly
Excessive
resistance
Exercise on the unit;
resistance is excessive
1. Flywheel magnet has become lose and stuck.
No telemetry heart
rate reception
Telemetry (wireless) heart
rate malfunction
1. Inspect the heart rate transmitter and its
batteries. Replace batteries.
2. Inspect the heart rate receiver board cable
connections.
3. Test or replace heart rate receiver board.
4. Inspect for environmental interference, for
example, speakers, lights, etc.
1. Telemetry heart
rate receiver
2. Telemetry heart
rate receiver
Contact heart rate
malfunction
HTR malfunction 1. Inspect HTR cables.
2. Replace the HTR board as a test.
1.HTR board
Key malfunction Keys do not operate or
operate continuously
1. Replace display key switches. Display board key
switches
2-1-1