WEG Gateway X1000 User manual

Category
Gateways/controllers
Type
User manual

This manual is also suitable for

Gateway X1000
Manual geral de instalação e operação
Installation and operation manual
Manual general de instalación y operación
Motores | Automação | Energia | Transmissão & Distribuição | Tintas
www.weg.net
Gateway X1000
3
Motores Elétricos2
MANUAL GERAL DE INSTALAÇÃO E OPERAÇÃO
GATEWAY X1000
Este manual contém as informações necessárias para correta instalação, configuração e
uso do gateway Cassia X1000.
Em caso de dúvidas sobre a aplicabilidade desse material, contate a WEG.
Português
2
English
19
Español
36
Gateway X1000 5
www.weg.net
Gateway X1000
4
PORTUGUÊS
PORTUGUÊS
www.weg.net
ÍNDICE
1. DEFINIÇÕES 5
2. AVISOS DE SEGURANÇA 5
3. RECOMENDAÇÕES INICIAIS 5
3.1. VERIFICAÇÃO NO RECEBIMENTO ................................................................................................... 6
3.2. ARMAZENAMENTO ........................................................................................................................... 6
3.3. DESCARTE E RECICLAGEM ............................................................................................................. 6
4. CERTIFICÕES E REGULAMENTAÇÕES 7
4.1. HOMOLOGAÇÃO ANATEL ................................................................................................................. 7
4.2. REGULAMENTAÇÃO FCC (EUA) ...................................................................................................... 7
4.3. REGULAMENTÃO IC (CANADÁ) .................................................................................................. 8
4.4. DIRETIVA DE EQUIPAMENTOS DE RÁDIO (UE) ............................................................................. 8
5. CONFIGURAÇÃO DO GATEWAY 9
5.1. ORIENTAÇÕES INICIAIS .................................................................................................................... 9
5.2. CONEXÃO À INTERNET .................................................................................................................... 9
5.2.1. INFRAESTRUTURA ......................................................................................................................... 9
5.3. REGISTRO DO GATEWAY ............................................................................................................... 10
5.4. CONFIGURAÇÕES DE CONEXÃO .................................................................................................. 12
5.4.1. CONEXÃO À REDE DO GATEWAY .............................................................................................. 12
5.4.2. LOGIN .......................................................................................................................................... 12
5.4.3. CONFIGURAÇÕES BÁSICAS ....................................................................................................... 12
5.4.4. CONFIGURAÇÕES DA REDE WI-FI ............................................................................................. 12
5.4.5. CONFIGURAÇÕES DO MODEM USB 3G/4G (DONGLE) ............................................................ 13
6. INSTALAÇÃO 14
6.1. INSTALAÇÃO DO CABO ETHERNET E ATERRAMENTO ............................................................. 14
6.2. INSTALAÇÃO DOS PLUGS DE SILICONE (GARANTIR VEDAÇÕES) .......................................... 14
6.3. INSTALÃO NO AMBIENTE DE OPERAÇÃO .............................................................................. 14
7. CONFIGURAÇÃO DOS SENSORES 15
8. INSTALÃO DO APLICATIVO 17
9. ESPECIFICAÇÃO TÉCNICA 17
10. TERMO DE GARANTIA 18
1. DEFINIÇÕES
Sensor – Ao longo deste manual o termo “sensor” é usado em referência ao dispositivo WEG Motor Scan -
dispositivo de monitoramento inteligente das características do motor.
IoT (Internet of Things) – É definida como a tecnologia que permite comunicação máquina a máquina (M2M)
via internet para o compartilhamento de dados e informações para finalidades pré-definidas.
App – Aplicativo de celular.
Gateway – Equipamento intermediário que utiliza recursos de internet para conectar o Sensor à plataforma
WEG IoT.
Bluetooth – Tecnologia de comunicação sem fios (wireless) que interliga e permite a transmissão de dados
entre computadores, telefones celulares e outros dispositivos através de ondas de rádio.
Ethernet
Ethernet é uma arquitetura de interconexão para redes locais - Rede de Área Local (LAN).
PoE é a abreviação para a sigla (Power Over Ethernet), que é uma tecnologia que permite a transmissão de energia
elétrica através dos cabos de uma rede Ethernet.
Hotspot é a denominação de um determinado local onde uma rede sem fio (tecnologia Wi-Fi) está disponível para ser
utilizada.
Firmware é o conjunto de instruções operacionais programadas diretamente no hardware de um equipamento
eletrônico. É ele que contém as informações de inicialização que permitem o correto funcionamento do aparelho.
2. AVISOS DE SEGURANÇA
Neste manual são utilizados os seguintes avisos de segurança:
PERIGO!
Não considerar os procedimentos recomendados neste aviso pode levar à morte, ferimentos graves,
danos materiais consideráveis e cancelamento da garantia.
ATENÇÃO!
Não considerar os procedimentos recomendados neste aviso pode levar a danos materiais.
NOTA!
Informações importantes para o correto entendimento e bom funcionamento do produto.
3. RECOMENDAÇÕES INICIAIS
Este manual contém as informações necessárias para correta instalação, configuração e uso do gateway
Cassia X1000 em conjunto com o sensor WEG Motor Scan (dispositivo de monitoramento inteligente das
características do motor).
Ele foi desenvolvido para uso de profissionais com treinamento ou qualificação técnica adequados para operar
este tipo de produto.
Não seguir as instruções do manual do produto pode ocasionar acidentes operacionais, danos ao meio
ambiente, ao dispositivo, além do cancelamento da garantia.
A correta definição das características do ambiente e da aplicação é de responsabilidade do usuário.
Durante o período de garantia do Gateway X1000, os serviços de reparo, revisão e recuperação devem ser
realizados por Assistentes Técnicos Autorizados WEG para continuidade do termo de garantia.
NOTA!
Siga as recomendações de instalações descritas nos itens 3, 4 e 5.
Gateway X1000 7
www.weg.net
Gateway X1000
6
PORTUGUÊS
PORTUGUÊS
www.weg.net
NOTA!
Leia completamente este manual antes de instalar ou operar o Gateway.
PERIGO!
Somente profissionais com qualificação adequada e familiaridade com o Gateway devem planejar ou
executar a instalação, operação e manutenção deste dispositivo.
O responsável pela instalação deve seguir todas as instruções de segurança contidas neste manual e/
ou definidas por normas locais.
Não seguir as instruções de segurança pode resultar em risco de morte e/ou danos ao Gateway.
3.1. VERIFICAÇÃO NO RECEBIMENTO
Ao receber o gateway Cassia X1000 verifique se a embalagem contém os seguintes itens: 1 Gateway X1000, 1
Fonte PoE, 1 Cabo Ethernet, 4 Parafusos/Buchas, 2 Abraçadeiras, 1 Suporte, 1 Conjunto de plugs de silicone
e 1 Manual rápido. Verifique o gateway imediatamente após desembalar para possível danos que podem ter
ocorrido devido a transporte inadequado.
PERIGO!
Na ocorrência de qualquer dano, registrar por escrito junto ao agente transportador, e comunicar
imediatamente a companhia seguradora e a WEG. A não comunicação pode resultar no cancelamento
da garantia.
3.2. ARMAZENAMENTO
NOTA!
Recomenda-se armazenar o Gateway em ambientes com temperatura máxima até 70 °C e evitar o
armazenamento do dispositivo sob luz solar direta.
3.3. DESCARTE E RECICLAGEM
Pensando no meio ambiente, a WEG desenvolve e fornece produtos que contribuem para redução dos
impactos ambientais ao longo do seu ciclo de vida. A participação do usuário na coleta seletiva e reciclagem
do equipamento eletroeletrônico usado, também é importante para minimizar qualquer efeito potencial destes
no meio ambiente e na saúde humana.
O descarte adequado do Gateway e seus componentes, de acordo com as legislações aplicáveis, é muito
importante para sua segurança e também do meio ambiente, além de ajudar a economizar recursos.
ATENÇÃO!
Para informações de retorno ou coleta disponível para o adequado tratamento e reciclagem entre em
contato com a WEG ou envie o Gateway e seus componentes para nossa Rede de Serviço Autorizado.
O gateway e seus componentes não devem ser descartados em lixo doméstico, comercial ou
industrial. Bem como, não devem ser descartados em incineradores e aterros de lixo municipal. O
descarte do gateway e seus componentes deve ser feito em conformidade com a regulamentação
local.
NOTA!
Este símbolo indica que:
- O produto não pode ser descartado em ponto de coleta de lixo municipal.
- Trata-se de coleta seletiva para equipamentos elétricos, eletrônicos e baterias.
- Todo o dispositivo e sua embalagem são fabricados a partir de materiais que podem ser
reciclados e no final de sua vida útil deve ser enviado a empresas de reciclagem especializada.
- A barra horizontal abaixo da lixeira indica que o equipamento foi comercializado após 13 de
agosto de 2005.
Figura 3.2 - Símbolo de descarte
NOTA!
O gateway ou componentes substituídos pela Assistência Técnica, são recolhidos pela WEG e
remetidos para os respectivos fornecedores para providenciarem o correto descarte.
Todo o dispositivo e sua embalagem são fabricados a partir de materiais que podem ser reciclados por
empresas de reciclagem especializada.
Informações sobre os materiais que constituem o gateway e seus componentes podem ser visualizados em:
www.weg.net/wegmotorscan
4. CERTIFICAÇÕES E REGULAMENTAÇÕES
4.1. HOMOLOGAÇÃO ANATEL
06600-19-12464
Para consulta do certificado de homologação ANATEL, acesso o seguinte endereço:
https://sistemas.anatel.gov.br/mosaico/sch/publicView/listarProdutosHomologados.xhtml
4.2. REGULAMENTAÇÃO FCC (EUA)
Contém FCC ID: 2ALGLX1000
Este equipamento foi testado e considerado em conformidade com os limites para um dispositivo digital de
Classe B, de acordo com a parte 15 das Regras da FCC. Esses limites foram criados para fornecer proteção
razoável contra interferência prejudicial em uma instalação residencial. Este equipamento gera, utiliza e pode
irradiar energia de radiofrequência e, se não for instalado e utilizado de acordo com as instruções, pode
causar interferência prejudicial às comunicações de rádio.
No entanto, não há garantia de que a interferência não ocorra em uma instalação específica. Se este
equipamento causar interferência prejudicial à recepção de rádio ou televisão, que pode ser determinada
desligando e ligando o equipamento, recomenda-se que o usuário tente corrigir a interferência usando uma ou
mais das seguintes medidas:
- Reoriente ou reposicione a antena receptora.
- Aumente a distância entre o equipamento e o receptor.
- Conecte o equipamento a uma tomada em um circuito diferente daquele ao qual o receptor está conectado.
- Consulte o revendedor ou um técnico experiente em rádio / TV para obter ajuda.
1x Conjunto de plugs de silicone
Guia Rápido de Instalação
1x Gateway X1000
Guia Rápido de Instalação
2x Abraçadeiras
Guia Rápido de Instalação
4x Parafusos/Buchas
Guia Rápido de Instalação
1x Suporte
1x Manual rápido
Guia Rápido de Instalação
1x Cabo Ethernet
1x Fonte PoE
Guia Rápido de Instalação
Este equipamento não tem direito à proteção contra interferência prejudicial e
não pode causar interferência em sistemas devidamente autorizados.
Figura 3.1 - Gateway e seus componentes
Gateway X1000 9
www.weg.net
Gateway X1000
8
PORTUGUÊS
PORTUGUÊS
www.weg.net
5. CONFIGURÃO DO GATEWAY
NOTA!
O gateway é utilizado para fazer upload dos dados dos sensores WEG Motor Scan para o portal
WEG IoT.
O gateway precisa ser configurado para ter acesso à Internet e registrado no portal WEG IoT.
5.1. ORIENTÕES INICIAIS
Para uma melhor experiência de uso, recomenda-se seguir a sequência de instruções conforme apresentado
neste manual. Os pontos expostos a seguir devem ser observados previamente ao início das configurações e
instalação do gateway.
a) O gateway não pode operar em redes com VPN (Virtual Private Network).
b) Em caso de uso de firewall, as portas TCP e UDP 6246 e 6247 devem estar disponíveis para uso da
comunicação do gateway.
c) O gateway não pode operar em redes configuradas com proxy.
d) Ao utilizar modens (dongles) 3G/4G na porta USB do gateway deve-se observar a presença de sinal de rede
da operadora selecionada. Em locais com nível de sinal baixo, pode ser necessário utilizar um cabo USB
extensor ou uma antena externa para o modem.
e) Somente sensores WEG Motor Scan nas versões 2.0 ou superiores estão habilitados a se comunicarem
com o gateway.
5.2. CONEXÃO À INTERNET
5.2.1 Infraestrutura
O gateway necessita de uma porta de acesso à Internet para ser configurado e executar upload de dados dos
sensores Weg Motor Scan. Há quatro formas de conectá-lo à Internet conforme descrito a seguir.
5.2.1.1 Power over Ethernet (POE) 5.2.1.2 LAN/Ethernet
A rede deve possuir infraestrutura adequada.
5.2.1.3 Wi-Fi 5.2.1.4 Modem 3G/4G (dongle)
NOTA!
Quaisquer alterações ou modificações que não são expressamente aprovadas pela parte responsável
pela conformidade podem anular a autoridade do usuário para operar o equipamento.
Para informações adicionais, acesse: https://www.cassianetworks.com
4.3. REGULAMENTAÇÃO IC (CANADÁ)
Contém IC: 22505-X1000
Este dispositivo está em conformidade com a licença da Indústria Canadense isenta dos padrões RSS.
A operação está sujeita às duas condições a seguir: (1) este dispositivo não pode causar interferência e (2)
este dispositivo deve aceitar qualquer interferência, incluindo interferências que possam causar operação
indesejada do dispositivo.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. Lexploitation est autorisée aux deux conditions suivantes : (1) I’appareil ne doit pas produire de
brouillage, et (2) I’utilisateur de Iappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
NOTA!
Para informações adicionais, acesse: https://www.cassianetworks.com
Pour obtenir de I’aide supplémentaire, rendez-vous sur: https://www.cassianetworks.com Cassia Networks, Inc.
4.4. DIRETIVA DE EQUIPAMENTOS DE RÁDIO (UE)
DECLARAÇÃO UE SIMPLIFICADA DE CONFORMIDADE
Por meio deste, Cassia Networks Inc. declara que:
O Equipamento de rádio roteador Bluetooth CASSIA X1000 Series, está em conformidade com:
Diretiva de Equipamento de Rádio 2014/53/UE;
Diretiva de Baixa Tensão 2014/35/EU;
Diretiva de Compatibilidade Eletromagnética 2014/30/EU;
Diretiva RoHS 2011/65/EU e seus adendos.
O texto integral da declaração de conformidade UE está disponível no seguinte endereço de internet:
https://www.cassianetworks.com.
PERIGO!
Aviso de exposição a RF:
Este equipamento deve ser instalado e operado de acordo com as instruções fornecidas e a(s)
antena(s) usada(s) para este transmissor devem ser instaladas a uma distância de pelo menos 20 cm
de todas as pessoas e não devem ser colocadas ou operadas em conjunto com qualquer outra antena ou
transmissor. Usuários finais e instaladores devem receber instruções de instalação da antena e condições
operacionais do transmissor para satisfazer a conformidade com a exposição à RF.
IOT Plaorm
PoE
IOT Plaorm
Gateway
Fonte PoELAN/Ethernet
WEG IoT Platform
OUT IN
IOT Plaorm
Gateway
Fonte PoE
Access Point (Wi-Fi)
WEG IoT Platform
OUT
IOT Plaorm
3G - 4G
Gateway
Fonte PoE
Modem 3G/4G
USB
WEG IoT Platform
OUT
Figura 5.1 - Power over Ethernet Figura 5.2 - LAN/Ethernet
Figura 5.3 - Wi-Fi Figura 5.4 - Modem 3G/4G (dongle)
Gateway X1000 11
www.weg.net
Gateway X1000
10
PORTUGUÊS
PORTUGUÊS
www.weg.net
5.3. REGISTRO DO GATEWAY
O gateway deve ser adicionado à Plataforma WEG IoT na planta de interesse. Para esta etapa deverá ser
utilizado um smartphone que contenha o aplicativo WEG Motor Scan.
Os passos para fazer o registro do gateway podem ser visualizados diretamente no aplicativo ou como
indicado nos passos abaixo:
Acesse o aplicativo “WEG Motor Scan” faça o login na conta de usuário do
portal WEG IoT.
Selecione “NOVO DISPOSITIVO”
Selecione Cassia X1000
Certifique-se que o gateway está ligado através do led na base inferior
a)Selecione a planta onde o gateway será instalado.
b)Apenas plantas de Motores onde o usuário que está realizando o cadastro possui perfil de
Administrador aparecerão na lista.
c)Não possui uma planta? Acesse “Nova planta” e cadastre-a.
a) Identifique o gateway utilizando o MAC address.
b) O MAC address está localizado na etiqueta fixada na base inferior do gateway.
Conecte-se ao hotspot do gateway (iOS) ou aguarde até o smartphone
exibir a rede do gateway próxima (Android).
OU
a) Atribua um nome ao gateway
b) O nome será utilizado na Plataforma WEG IoT para identificação do gateway
a) Utilize tags para aulio na identificação dos dispositivos na Plataforma
b) O uso de tags é altamente recomendado. Podem ser atribuídas várias tags ao mesmo
dispositivo.
a) Certifique-se que há internet disponível.
b) Aguarde até a confirmação de que o gateway foi adicionado à Plataforma.
Gateway X1000 13
www.weg.net
Gateway X1000
12
PORTUGUÊS
PORTUGUÊS
www.weg.net
5.4. CONFIGURAÇÕES DE CONEXÃO
5.4.1 Conexão à rede do gateway
a) Certifique-se que o gateway está ligado através do led na base
inferior.
b) Utilizando um computador ou smartphone conecte-se à rede Wi-Fi
do gateway.
c) O endereço da rede corresponde aos 6 dígitos finais do MAC
address do gateway. A senha da rede é igual ao endereço, por
exemplo, para a rede “cassia-A12345” a senha será “cassia-A12345.
A imagem a seguir ilustra onde pode ser conferido o MAC adress
do gateway.
d) Se não for possível encontrar o Hotspot (ponto de acesso) Wi-Fi do
gateway, deve-se reiniciá-lo pressionando e segurando o botão de
reset localizado na base inferior do gateway durante 15 segundos.
5.4.2 Login
a) Utilize o navegador de internet (preferencialmente Google Chrome)
para acessar a página do gateway.
b) Digite o IP 192.168.40.1 na aba de endereço. A tela ao lado ilustra
o portal inicial de configuração.
c) Acessos padrões de login:
Old Password: admin Username: admin Password: 12345678
d) Caso os dados de logins foram perdidos é possível reiniciar o
gateway para o padrão de fábrica pressionando o botão de reset
na base inferior do gateway durante 15 segundos.
5.4.3 Configurações básicas
Configurações da aba “Basic”
Router mode > AC Managed Router
TX Power > 20
Statistics Report Interval > 30 Seconds
AC Server Address > cassia.weg.net
AC-Router Comm. Ports > 6246, 6247
Remote Assistance > ON
Connection Priority > De acordo com o tipo de conexão
utilizada “Wired” (rede à cabo)
IP Allocation > Configurar de acordo com a disponibilidade
da rede: Static IP ou DHCP
Ao utilizar o modo Static IP, deve-se incluir as seguintes
informações sobre a rede: IP, Netmask, Gateway e DNS.
5.4.4 Configurações da rede Wi-Fi
Para configurar o gateway em uma rede Wi-Fi deve-se inicialmente
selecionar o modo de operação “Operating Mode: Client. O usuário
pode optar por DHCP ou Static para obtenção do endereço IP.
O usuário ainda pode selecionar o modo de rede segura, necessitando
fornecer os dados de entrada para assim conectar o Wi-Fi do gateway
com nível de segurança Enterprise.
5.4.5 Configurações do modem USB 3G/4G (dongle)
a) Antes de utilizar o modem USB 3G/4G certifique-se que o mesmo está funcionando e possibilita acesso à
Internet, com auxílio de um computador.
b) Conecte o modem na porta USB na base inferior do gateway e selecione o modelo correto através da aba
“USB Dongle Type”. Configure os parâmetros se necessário.
c) Modems com RNDIS Driver Ethernet tipo 1 e tipo 2 são suportados:
Tipo 1: uma APN precisa ser especificada. Por exemplo, wyleslte.gw7.vzwentp e 10569.mcs é KORE Wireless
APN. NOTA: se um SIM card de uma outra operadora é utilizado, deve-se questioná-la sobre o APN correto a
ser utilizado.
Tipo 2: a configuração ocorre automaticamente apresentando assim a rede LAN. Por exemplo, o modem
Huawei E3372s-153.
Security mode Dados requisitados
None ---
WPA2-PSK
Senha
WPA [TKIP]+WPA2 [AES]
[Enterprise] WPA2
[Enterprise] WPA [TKIP]+
WPA2 [AES]
EAP Necessário
PEAP-
MSCHAPV2
[Enterprise] WPA [TKIP] + WPA2 [AES]
Identificação e senha
TTLS Identificação, senha e certificado CA
TLS Identificação, senha e certificado CA, Private Key e senha
Figura 5.5 - Conexão à rede do gateway
Figura 5.6 - Login
Figura 5.7 - Configurações básicas
Figura 5.8 - Configurações da rede Wi-Fi
Figura 5.9 - Configurões do modem USB 3G/4G (dongle)
Gateway X1000 15
www.weg.net
Gateway X1000
14
PORTUGUÊS
PORTUGUÊS
www.weg.net
6. INSTALAÇÃO
PERIGO!
Risco de choque. Não toque em partes ou equipamentos eletricamente energizados. Antes de iniciar a
instalação do gateway desconecte a fonte de alimentação.
ATENÇÃO!
Condições ambientais de operação permitidas: temperatura de -40 °C a 65 °C (condições nominais).
A instalação do gateway em campo é simples e não requer o uso de ferramentas avançadas. A distância
de alcance depende de fatores como barreiras físicas entre o gateway e os sensores, interferência de
sinais e a correta instalação. Estima-se que o alcance em ambientes industriais possa atingir 30 metros e
em campo aberto (sem interferências ou barreiras) 50 metros.
6.1. INSTALAÇÃO DO CABO ETHERNET E ATERRAMENTO
( 1 ) Remova a tampa inferior.
( 2 ) Insira o cabo Ethernet na porta adequada e instale o
aterramento na posição marcada. Reinstale a tampa inferior.
6.2. INSTALAÇÃO DOS PLUGS DE SILICONE
(1) Instale o plug de silicone no cabo Ethernet.
(2) Deslize o plug até o encaixe na base inferior.
(3) Instale os 3 plugs nos orifícios inferiores.
6.3. INSTALAÇÃO NO AMBIENTE DE OPERÃO
(1) Instale o suporte de fixação utilizando os parafusos e buchas (quando fixado em paredes) ou as
abraçadeiras metálicas quando instalado em postes.
(2) Engate o gateway no suporte deslizando-o até ocorrer o clique.
(3) A direção de melhor recepção de sinal está localizada no logotipo da Cassia.
Recomenda-se instalá-lo em ambientes sem obstáculos entre o gateway e os sensores, afastado do chão.
7. CONFIGURAÇÃO DOS SENSORES
Após a instalação do gateway no campo, deve-se verificar quais sensores estão ao alcance. Esta atividade é
realizada utilizando a Plataforma WEG IoT e o aplicativo WEG Motor Scan.
Os passos para fazer a configuração dos sensores podem ser visualizados diretamente no aplicativo e no manual
completo.
a) Efetue o login na Plataforma: iot.weg.net
b) Na planta onde o gateway foi instalado, clique no gateway para acesso a mais detalhes.
c) Acesse a aba “Possíveis conexões”. Serão exibidos os sensores ao alcance do gateway.
Importante: estes sensores não estão enviando dados para o gateway. Eles devem serem configurados
(próximos passos).
d) Anote o nome dos sensores. Para configurá-los deve-se utilizar o aplicativo móvel.
e) Selecione o sensor. O aplicativo fará o download
dos dados armazenados automaticamente.
Figura 6.1 - Instalação do cabo Ethernet e aterramento
Figura 6.2 - Instalão dos plugs de silicone
Figura 6.3 - Instalação no ambiente de operação
Gateway X1000 17
www.weg.net
Gateway X1000
16
PORTUGUÊS
PORTUGUÊS
www.weg.net
f) Após o download, deve-se clicar no botão “Mais”.
g) Na tela “Mais”, clique em “Ligar modo gateway”.
Nesta tela aparecerá a opção para habilitar a comunicação do sensor com
o gateway. Clique em “Sim”.
Após concluir os procedimentos o sensor estará habilitado a enviar seus dados para o gateway.
O download de dados utilizando um smartphone ainda é possível, porém, com uma leve perda de
performance de pareamento (não afetando a performance de download).
Para atualizações do firmware do sensor, reset ou edição de dados de placa do motor, é necessário
desabilitar o “Modo gateway”, desfazendo a última etapa deste procedimento.
8. INSTALÃO DO APLICATIVO
O aplicativo WEG Motor Scan está disponível nas plataformas iOS™ e Android. Pode ser baixado diretamente
nas lojas App Store e Google Play Store, pesquisando por WEG MOTOR SCAN, ou através de QR Code:
9. ESPECIFICAÇÃO TÉCNICA
Massa 800g
Dimensões 154 x 259 mm (DxA)
Grau de proteção IP65
Temperatura de operação -40 °C a 65 °C
Umidade relativa do ar até 90% sem condensação
Resistência ao vento até 135km/h constante – rajadas 215km/h
Conformidade
FCC (US), IC (Canadá), CE (Europa), TELEC (Japão), CB, CRC (Colômbia), BQB, SRRC (China), RoHS,
REACH, ICASA (África do Sul), ANATEL (Brasil), RCM (Austrália), SUBTEL (Chile), NOM (México)
Bluetooth
®
4.0, 4.1
Wi-Fi 802.11 b/g/n 2.4GHz
Ethernet 10/100
USB 2.0 modem 3G/4G
PoE 802.3af/at
ATENÇÃO!
O gateway Cassia X1000 está constantemente em atualização. Por este motivo, as informações
contidas neste guia podem ser alteradas sem aviso prévio.
NUVEM
Disponível em:
APP
WEG IOT PLATFORM
GATEWAY
Figura 7.1 - Fluxo de aquisição, processamento e geração de diagnóstico dos dados
Figura 8.1 - QR Code para baixar o aplicativo WEG Motor Scan
Gateway X1000 19
ENGLISH
www.weg.netwww.weg.net
Gateway X1000
18
PORTUGUÊS
10. TERMO DE GARANTIA
A WEG Equipamentos Elétricos S/A, Unidade Motores (“WEG”), oferece garantia contra defeitos de fabricação
e de materiais para o produto Gateway pelo período de 12 meses, contados a partir da data de emissão da
nota fiscal da fábrica ou do distribuidor/revendedor.
Nos prazos de garantia acima estão contidos os prazos de garantia legal, não sendo cumulativos entre si.
Caso um prazo de garantia diferenciado estiver definido na proposta técnico-comercial para determinado
fornecimento, este prevalecerá sobre os prazos acima.
Os prazos estabelecidos acima independem da data de instalação do produto e de sua entrada em operação.
Na ocorrência de um desvio em relação à operação normal do produto, o cliente deve comunicar
imediatamente por escrito à WEG sobre os defeitos ocorridos, e disponibilizar o produto para a WEG ou seu
Assistente Técnico Autorizado pelo prazo necessário para a identificação da causa do desvio, verificação da
cobertura da garantia, e para o devido reparo.
Para ter direito à garantia, o cliente deve atender às especificações dos documentos técnicos da WEG,
especialmente àquelas previstas no Manual de Instalação e Operação dos produtos, e às normas e
regulamentações vigentes em cada país.
Não possuem cobertura da garantia os defeitos decorrentes de utilização, operação e/ou instalação
inadequadas ou inapropriadas dos equipamentos, bem como defeitos decorrentes de fatores externos ou
equipamentos e componentes não fornecidos pela WEG.
A garantia não se aplica se o cliente, por própria iniciativa, efetuar reparos e/ou modificações no equipamento
sem prévio consentimento por escrito da WEG.
A garantia não cobre equipamentos, partes e/ou componentes, cuja vida útil for inferior ao período de garantia.
Não cobre, igualmente, defeitos e/ou problemas decorrentes de força maior ou outras causas que não
podem ser atribuídas à WEG, como por exemplo, mas não limitado a: especificações ou dados incorretos ou
incompletos por parte do cliente, transporte, armazenagem, manuseio, instalação e operação em desacordo
com as instruções fornecidas, acidentes, deficiências de obras civis, utilização em aplicações e/ou ambientes
para os quais o produto não foi projetado, equipamentos e/ou componentes não inclusos no escopo de
fornecimento da WEG. A garantia não inclui os serviços de desmontagem nas instalações do cliente, os custos
de transporte do produto e as despesas de locomoção, hospedagem e alimentação do pessoal da Assistência
Técnica, quando solicitados pelo cliente.
Os serviços em garantia serão prestados exclusivamente em oficinas de Assistência Técnica autorizadas pela
WEG ou na sua própria fábrica. Em nenhuma hipótese, estes serviços em garantia prorrogarão os prazos de
garantia do equipamento.
A responsabilidade civil da WEG está limitada ao produto fornecido, não se responsabilizando por danos
indiretos ou emergentes, tais como lucros cessantes, perdas de receitas e afins que, porventura, decorrerem
do contrato firmado entre as partes.
Português
2
English
19
Español
36
Gateway X1000 21
ENGLISH
www.weg.net
Gateway X1000
20
www.weg.net
INSTALLATION AND OPERATION MANUAL OF
GATEWAY X1000
This manual contains the necessary information for the correct installation,
setup and use of the Gateway Cassia X1000.
If you have any questions regarding this manual, please contact your
local WEG branch, contact details can be found at www.weg.net.
TABLE OF CONTENTS
1. TERMINOLOGY 22
2. SAFETY WARNINGS IN THE MANUAL 22
3. PRELIMINARY RECOMMENDATIONS 22
3.1. RECEIVING INSPECTION ................................................................................................................. 23
3.2. STORAGE ......................................................................................................................................... 23
3.3. DISPOSAL AND RECYCLING .......................................................................................................... 23
4. CERTIFICATIONS AND REGULATIONS 24
4.1. ANATEL APPROVAL ......................................................................................................................... 24
4.2. FCC REGULATIONS (US) ................................................................................................................ 24
4.3. IC REGULATIONS (CANADA) .......................................................................................................... 25
4.4. RADIO EQUIPMENT DIRECTIVE (EU) ............................................................................................ 25
5. GATEWAY SETUP 26
5.1. INITIAL GUIDELINES ........................................................................................................................ 26
5.2. INTERNET CONNECTION ................................................................................................................ 26
5.2.1. INFRASTRUCTURE ....................................................................................................................... 26
5.3. GATEWAY REGISTRATION ............................................................................................................. 27
5.4. CONNECTION SETTINGS ................................................................................................................ 29
5.4.1. GATEWAY NETWORK CONNECTION .......................................................................................... 29
5.4.2. LOGIN .......................................................................................................................................... 29
5.4.3. BASIC SETTINGS .......................................................................................................................... 29
5.4.4. WI-FI NETWORK SETTINGS ........................................................................................................ 29
5.4.5. USB 3G/4G MODEM (DONGLE) SETTINGS ................................................................................ 30
6. INSTALLATION 31
6.1. INSTALLATION OF THE ETHERNET CABLE AND GROUNDING ................................................. 31
6.2. SILICON PLUG INSTALLATION (ENSURE SEALS) ....................................................................... 31
6.3. INSTALLATION IN THE OPERATING ENVIRONMENT .................................................................. 31
7. SENSOR CONFIGURATION 32
8. INSTALLATION OF THE APPLICATION 34
9. TECHNICAL DATA 34
10. WARRANTY 35
Gateway X1000 23Gateway X100022
ENGLISH
ENGLISH
www.weg.net www.weg.net
1. TERMINOLOGY
Sensor - In this manual, the term “sensor” refers to the WEG Motor Scan device - smart device to monitor
motor characteristics.
IoT (Internet of Things) – It is defined as the technology that allows machine-to-machine (M2M)
communication over the internet for the sharing of data and information for predefined purposes.
App – Mobile app.
Gateway – Intermediate equipment that uses internet resources to connect the Sensor to the WEG IoT
platform. In this manual, the term “gateway” refers to the Gateway X1000 device.
Bluetooth – Wireless technology that interconnects and allows the transmission of data between computers,
mobile phones and other devices through radio waves.
Ethernet - Ethernet is an interconnect architecture for local area networks - Local Area Network (LAN).
PoE – It is the abbreviation for Power Over Ethernet, which is a technology that allows the transmission of
electricity through the cables of an Ethernet network.
Hotspot – It is the name of a particular place where a wireless network (Wi-Fi technology) is available for use.
Firmware – It is the set of operating instructions programmed directly into the hardware of an electronic device.
It contains the initialization information that allows the device to function properly.
2. SAFETY WARNINGS IN THE MANUAL
The following safety notices are used in this manual:
DANGER!
Failure to comply with the procedures recommended in this warning may lead to death, serious injuries
and considerable material damages. It may also void the warranty.
ATTENTION!
Not following the procedures recommended in this warning may cause material damages.
NOTE!
Important information for the complete understanding and proper operation of the product.
3. PRELIMINARY RECOMMENDATIONS
This manual contains the necessary information for the correct installation, setup and use of the Cassia X1000
gateway with the WEG Motor Scan sensor (smart monitoring device for motor characteristics).
It was developed to be used by people with proper technical training or qualification to operate this kind of
equipment.
Failure to comply with the product instructions may cause operating accidents, damages to the environment, to
the device, in addition to voiding the warranty.
The user is responsible for the correct definition of the installation environment and application characteristics.
During the warranty period of Gateway X100, all repair, overhaul and reclamation services must be carried out
by WEG authorized Service Centers to maintain validity of the warranty.
NOTE!
Follow the installation instructions described in chapters 3, 4 and 5.
NOTE!
Read the whole manual before installing or operating the Gateway.
DANGER!
Only qualified people familiar with the Gateway should plan or execute the installation, operation and
maintenance of this device.
Such personnel must follow the safety instructions described in this guide and/or defined by local regulations.
Failure to comply with the safety instructions may lead to death and/or damages to the Gateway.
3.1. RECEIVING INSPECTION
At the receipt of the Gateway Cassia X1000, check that the packaging contains the following items: 1 Gateway
X1000, 4 screws/bushings, 2 clamps, 1 Quick Guide, 1 Silicone plug set, 1 PoE Power Supply, 1 Ethernet
cable and 1 Bracket. Check the Gateway immediately after unpacking to identify possible damages occurred
due to improper transportation.
Guia Rápido de Instalação
1x Gateway X1000
Guia Rápido de Instalação
Guia Rápido de Instalação
Guia Rápido de Instalação
Guia Rápido de Instalação
Guia Rápido de Instalação
Guia Rápido de Instalação
1x Silicone plug set
2x Clamps
4x Screws/Bushings
1x Bracket
1x Quick guide
1x Ethernet cable
1x PoE Power Supply
DANGER!
All damages must be reported in writing to the transportation company, to the insurance company and
to WEG. Failure to comply with such procedures will void the product warranty.
3.2. STORAGE
NOTE!
It is recommended to store the gateway at a maximum temperature of 70 °C and not exposed to direct
sunlight.
3.3. DISPOSAL AND RECYCLING
WEG is committed to the environment and supplies products that contribute to reducing the environmental
impacts along their life cycle. The user’s participation in the waste sorting and recycling of the electro-electronic
devices is also important to minimize their potential impact on the environment and human health.
The proper disposal of the Gateway, observing the applicable laws, is very important for your safety and also of
the environment, in addition to helping save resources.
ATTENTION!
For information on the return or collection for the proper disposal and recycling of the product, contact
WEG or send the gateway to one of our authorized service centers.
The gateway should not be disposed of with household, commercial or industrial waste. They cannot be
disposed of in incinerators and city landfills either. The gateway must be disposed of in compliance with the
local regulations.
Figura 3.1 - Gateway e seus componentes
Gateway X1000 25Gateway X100024
ENGLISH
ENGLISH
www.weg.net www.weg.net
NOTE!
This symbol indicates that:
- At the end of its service life, the product must enter the recycling system.
- You should dispose of it separately at an appropriate collection point; do not dispose of
it with municipal solid waste.
- It is waste sorting of electric and electronic devices, and batteries.
- The horizontal bar below the garbage bin indicates the device was manufactured after
August 13, 2005.
Figure 3.4 - Disposal symbol
NOTE!
The Gateway or components replaced by the Technical Assistance are collected by WEG and sent to
the respective suppliers for the correct disposal.
The whole device and its package are made of materials that can be recycled by specialized waste
sorting companies.
Information on the materials that compose the Gateway and its components can be viewed on:
www.weg.net/wegmotorscan
4. CERTIFICATIONS AND REGULATIONS
4.1. ANATEL APPROVAL
06600-19-12464
To consult the ANATEL approval certificate, access the following address:
https://sistemas.anatel.gov.br/mosaico/sch/publicView/listarProdutosHomologados.xhtml
4.2. FCC REGULATIONS (US)
It contains FCC ID: 2ALGLX1000
This device has no right to protection against harmful interference and cannot cause interference in duly
authorized systems.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
NOTE!
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
For additional information, please go to: https://www.cassianetworks.com
This device has no right to protection against harmful interference and cannot
cause interference in duly authorized systems.
4.3. IC REGULATIONS (CANADA)
It contains IC: 22505-X1000
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. Lexploitation est autorisée aux deux conditions suivantes : (1) I’appareil ne doit pas produire de
brouillage, et (2) I’utilisateur de Iappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
NOTE!
For additional information, please go to: https://www.cassianetworks.com Cassia Networks, Inc.
Pour obtenir de I’aide supplémentaire, rendez-vous sur: https://www.cassianetworks.com Cassia Networks, Inc.
4.4. RADIO EQUIPMENT DIRECTIVE (EU)
EU SIMPLIFIED DECLARATION OF CONFORMITY
Hereby, Cassia Networks Inc. declares that:
Bluetooth Router Radio Equipment CASSIA X1000 Series, conforms with:
Radio Equipment Directive 2014/53/EU;
Low Voltage Directive 2014/35/EU;
Electromagnetic Compatibility (EMC) Directive 2014/30/EU;
RoHS Directive 2011/65/EU and its addenda.
The full text of the EU Declaration of Conformity is available at the following website:
https://www.cassianetworks.com.
DANGER!
RF exposure warning:
This equipment must be installed and operated in accordance with provided instructions and the
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
End-users and installers must be provided with antenna installation instructions and transmitter operating
conditions for satisfying RF exposure compliance.
Gateway X1000 27Gateway X100026
ENGLISH
ENGLISH
www.weg.net www.weg.net
5. GATEWAY SETUP
NOTE!
The gateway is used to upload data from WEG Motor Scan sensors to the WEG IoT portal.
The gateway must be configured to have Internet access and registered with the WEG IoT portal.
5.1. INITIAL GUIDELINES
For a better user experience, we recommend following the instruction sequence as presented in this guide.
The following points should be noted before beginning the gateway setup and installation.
a) The gateway cannot operate on virtual private networks (VPN).
b) In case of using firewall, TCP and UDP ports 6246 and 6247 must be available for use in gateway
communication.
c) The gateway cannot operate on proxy configured networks.
d) When using 3G/4G modems (dongles) on the gateway USB port, you should observe the presence of the
selected provider network signal. In low-signal locations, you may need an extension USB cable or an external
antenna for the modem.
e) WEG Motor Scan sensors in versions 2.0 or higher are enabled to communicate with the gateway only.
5.2. INTERNET CONNECTION
5.2.1 Infrastructure
The gateway requires an internet access port for setup and data upload from WEG Motor Scan sensors. It can
be connected to the Internet in four ways, as described below.
5.2.1.1 Power over Ethernet (POE) 5.2.1.2 LAN/Ethernet
The network must have suitable infrastructure.
5.2.1.3 Wi-Fi 5.2.1.4 Modem 3G/4G (dongle)
IOT Plaorm
PoE
IOT Plaorm
Gateway
Fonte PoELAN/Ethernet
WEG IoT Platform
OUT IN
IOT Plaorm
Gateway
Fonte PoE
Access Point (Wi-Fi)
WEG IoT Platform
OUT
IOT Plaorm
3G - 4G
Gateway
Fonte PoE
Modem 3G/4G
USB
WEG IoT Platform
OUT
Figure 5.1 - Power over Ethernet Figure 5.2 - LAN/Ethernet
Figure 5.3 - Wi-Fi Figure 5.4 - Modem 3G/4G (dongle)
5.3. GATEWAY REGISTRATION
The gateway must be added to the WEG IoT Platform at the plant of interest. For this step, a smartphone
containing the WEG Motor Scan app must be used.
The steps to register the gateway can be viewed directly in the app or in the instructions bellow:
Access the “WEG Motor Scan” app and login to the WEG IoT portal user
account.
Select “NEW DEVICE”.
Select Cassia X1000.
Make sure the gateway is turned on checking the LED at the bottom.
a) Select the plant where the gateway will be installed.
b) Only Motor plants where the user making the registration has an Administrator profile will
appear in the list.
c) Don’t you have a plant? Go to “New plant” and register it.
Gateway X1000 29Gateway X100028
ENGLISH
ENGLISH
www.weg.net www.weg.net
a) Identify the gateway using the MAC address.
b) The MAC address is located on the label attached to the bottom of the gateway.
Connect to the gateway hotspot (iOS) or wait until the smartphone
displays the nearby gateway network (Android).
OR
a) Name the gateway.
b) The name will be used on the WEG IoT Platform to identify the gateway.
a) Use tags to help identify devices on the Platform.
b) The use of tags is highly recommended. Multiple tags can be assigned to the same device.
a) Make sure there is internet available.
b) Wait for confirmation that the gateway has been added to the Platform.
5.4. CONNECTION SETTINGS
5.4.1 Gateway network connection
a) Make sure the gateway is turned on checking the LED at the bottom.
b) Using a computer or smartphone, connect to the gateway Wi-Fi
network.
c) The network address corresponds to the last 6 digits of the gateway
MAC address. The network password is the same as the address; for
example, for the network “cassia-A12345” the password will be
cassia-A12345. The following image illustrates where the gateway
MAC address can be found.
d) If you cannot find the gateway Wi-Fi hotspot, you must restart it by
pressing and holding the reset button located at the bottom of the
gateway for 15 seconds.
5.4.2 Login
a) Use the web browser (preferably Google Chrome) to access the
gateway page.
b) Enter the IP 192.168.40.1 in the address tab. The screen above
illustrates the initial configuration portal.
c) Standard login
Old Password: admin Username: admin Password: 12345678
d) If the login data have been lost, it is possible to reset the gateway
to factory default by pressing the reset button at the bottom of the
gateway for 15 seconds.
5.4.3 Basic settings
“Basic” tab settings
Router mode > AC Managed Router
TX Power > 20
Statistics Report Interval > 30 Seconds
AC Server Address > cassia.weg.net
AC-Router Comm. Ports > 6246, 6247
Remote Assistance > ON
Connection Priority > According to the connection type
used Wired (cable network)
IP Allocation > Configure according to network availability:
Static IP or DHCP
When using Static IP mode, you must include the following
network information: IP, Netmask, Gateway and DNS.
5.4.4 Wi-Fi network settings
To set the gateway on a Wi-Fi network, you must first select “Operating
Mode: Client. The user can choose DHCP or Static to obtain the IP
address.
The user can also select the secure network mode, being thus
necessary to provide the input data in order to connect the gateway Wi-
Fi with the Enterprise security level.
Figure 5.5 - Gateway network connection
Figure 5.6 - Login
Figure 5.7 - Basic settings
Figure 5.8 - Wi-Fi network settings
Gateway X1000 31Gateway X100030
ENGLISH
ENGLISH
www.weg.net www.weg.net
5.4.5 USB 3G/4G modem (dongle) settings
a) Before using the 3G/4G USB modem, make sure it is working and provides Internet access using a
computer.
b) Plug the modem into the USB port at the bottom of the gateway and select the correct model via the “USB
Dongle Type” tab. Set the parameters if necessary.
c) Modems with RNDIS Driver Ethernet Type 1 and Type 2 are supported:
Type 1: an APN must be specified. For example, wyleslte.gw7.vzwentp and 10569.mcs is KORE Wireless
APN. NOTE: If a SIM card from another provider is used, you should ask such provider about the
correct APN to be used.
Type 2: Setup occurs automatically, thus presenting the LAN network. For example, the Huawei E3372s-153
modem.
Security mode Required data
None ---
WPA2-PSK
Password
WPA [TKIP]+WPA2 [AES]
[Enterprise] WPA2
[Enterprise] WPA [TKIP]+
WPA2 [AES]
EAP Necessary
PEAP-
MSCHAPV2
[Enterprise] WPA [TKIP] + WPA2 [AES]
ID and password
TTLS ID, password and CA certificate
TLS ID, password and CA certificate, Private Key and Password
Figure 5.9 - USB 3G/4G modem (dongle) settings
6. INSTALLATION
DANGER!
Risk of electric shock. Do not touch electrically energized parts or devices. Before starting to install the
gateway, disconnect the power supply.
ATTENTION!
Acceptable environmental operating conditions: temperature from -40 °C up to 65 °C (rated conditions).
The gateway installation in the field is simple and does not require the use of advanced tools. The signal range
depends on factors such as physical barriers between the gateway and sensors, signal interference and proper
installation. It is estimated that the signal range in industrial environments can reach 30 meters and in the open
field (without interference or barriers) 50 meters.
6.1. INSTALLATION OF THE ETHERNET CABLE AND GROUNDING
( 1 ) Remove the bottom cover.
( 2 ) Insert the Ethernet cable into the proper port
and install the grounding in the marked position.
Reinstall the bottom cover.
6.2. SILICON PLUG INSTALLATION (ENSURE SEALS)
(1) Install the silicone plug on the
Ethernet cable.
(2) Slide the plug into the opening
at the bottom base.
(3) Install the 3 plugs into the bottom holes.
6.3. INSTALLATION IN THE OPERATING ENVIRONMENT
(1) Install the mounting bracket using the screws and bushings (when wall mounted) or the metal clamps (when
mounted on posts).
(2) Fix the gateway to the bracket by pushing it until it clicks into position.
(3) The direction for the best signal reception is located on the Cassia logo. It is recommended to install it in an
environment without obstructions between the gateway and the sensors, away from the floor.
Figure 6.1 - Installation of the Ethernet cable and grounding
Figure 6.2 - Silicon plug installation (ensure seals)
Figure 6.3 - Installation in the operating environment
Gateway X1000 33Gateway X100032
ENGLISH
ENGLISH
www.weg.net www.weg.net
7. SENSOR CONFIGURATION
After installing the gateway in the field, you should check which sensors are within the signal range. This activity
is performed using the WEG IoT Platform and the WEG Motor Scan app.
The steps to set up the sensors can be viewed directly in the app and in the below instructions.
a) Log in to the Platform: iot.weg.net
b) In the plant where the gateway was installed, click on the gateway for more details.
c) Go to the “Possible connections” tab. The sensors within the gateway range will be displayed.
Important: These sensors are not sending data to the gateway. They need to be configured (next steps).
d) Write down the name of the sensors. To configure them you must use the mobile app.
e) Select the sensor. The app will download automatically stored data.
f) After the download, you must click the “More” button.
g) On the “More” screen, click “Turn on gateway mode.
This screen will show the option to enable the sensor communication
with the gateway. Click on “Yes”.
After completing the procedures, the sensor will be able to send its data to the gateway.
Downloading data using a smartphone is still possible; however, with a slight loss of pairing performance
(not affecting the download performance).
For sensor firmware upgrades, reset, or motor nameplate data editing, you must disable the “Gateway mode”
by undoing the last step of this procedure.
Figure 7.1 - WEG Motor Scan data sharing and analysis flow
CLOUD
GATEWAY
Available at:
APP
WEG IOT PLATFORM
Gateway X1000 35Gateway X100034
ENGLISH
ENGLISH
www.weg.net www.weg.net
8. INSTALLATION OF THE APPLICATION
The WEG Motor Scan application is available in the iOS and Android™ platforms. It can be downloaded
at the App Store and Google Play Store by searching for WEG MOTOR SCAN or through QR Code:
9. TECHNICAL DATA
Mass 800g
Dimensions 154 x 259 mm (DxA)
Degree of protection IP65
Operating temperature -40 °C to 65 °C
Air relative humidity up to 90% - non-condensing
Wind resistance up to 135km/h constant – gusts of 215km/h
Compliance
FCC (US), IC (Canada), CE (Europe), TELEC (Japan), CB, CRC (Colombia), BQB, SRRC (China), RoHS,
REACH, ICASA (South Africa), ANATEL (Brazil), RCM (Australia), SUBTEL (Chile), NOM (Mexico)
Bluetooth
®
4.0, 4.1
Wi-Fi 802.11 b/g/n 2.4GHz
Ethernet 10/100
USB 2.0 modem 3G/4G
PoE 802.3af/at
ATTENTION!
The Cassia X1000 gateway is constantly being updated. Therefore, the information contained herein
may be changed without previous notice.
Figure 8.1 - QR Code to download the app WEG Motor Scan
10. WARRANTY
WEG Equipamentos Elétricos S/A, Motors Unit (“WEG”), provides warranty against defects in workmanship and
materials for the WEG Motor Scan for a period of 12 months or for the period of the license duration when there
is renewal of the service subscription, provided that uninterruptedly, counted from the date of the invoice issued
by the factory or distributor/dealer.
The paragraph above contains the legal warranty periods, seeing that they are not cumulative.
If a warranty period is defined differently in the technical and commercial proposal of a particular sale, such
period shall override the time limits set out above.
The periods above are independent of product installation date and start of operation.
In case of any abnormal behavior in the product operation, the customer must immediately notify WEG in
writing of the defect occurred and make the product available for WEG or its Authorized Technical Assistance
for the period necessary to identify the cause of the defect, verify the warranty coverage, and perform the
proper repairs.
In order to be entitled to the warranty, the customer must meet the specifications of WEG’s technical
documents, especially those provided in the product Installation, Operation and Maintenance Manual, as well
as the rules and regulations in force in each country.
The defects arising from the inappropriate or negligent use, operation, and/or installation of the equipment are
not covered by the warranty, as well as defects resulting from external factors or equipment and components
not supplied by WEG.
The warranty will not apply if the customer, at its own discretion, makes repairs and/or modifications to the
equipment without prior consent in writing by WEG.
The warranty shall not cover equipment, parts and/or components whose useful life is usually shorter than the
warranty period. It also does not cover defects and/or problems resulting from force majeure or other causes
that cannot be attributed to WEG, such as but not limited to: incorrect or incomplete specifications or data
supplied by the customer, transportation, storage, handling, installation and operation not complying with the
provided instructions, accidents, defects in the construction works, use in applications and/or environments for
which the product was not designed, equipment and/or component not included in the scope of WEGs supply.
The warranty does not include disassembly services at the premises of the customer, product transportation
costs and travel, lodging and meal expenses for the staff of the Technical Assistance, when requested by the
customer.
The services under warranty shall be executed solely at WEG authorized repair shops or at its own factory.
Under no circumstances will the warranty services extend the equipment warranty period.
WEGs Civil Liability is limited to the supplied product; WEG will not take any liability for indirect or consequential
damages, such as loss of profit, revenue losses and the like which may arise from the contract signed between
the parties.
Gateway X1000 37Gateway X100036
ESPAÑOL
ESPAÑOL
www.weg.net www.weg.net
Português
2
English
19
Español
36
MANUAL GENERAL DE INSTALACIÓN Y OPERACIÓN
WEG MOTOR SCAN
Este manual contiene las informaciones necesarias para la correcta instalación, configuración
y uso del gateway Cassia X1000 en conjunto con el sensor WEG Motor Scan.
En caso de dudas sobre la aplicabilidad de este material, póngase en contacto con WEG.
Gateway X1000 39Gateway X100038
ESPAÑOL
ESPAÑOL
www.weg.net www.weg.net
ÍNDICE
1. DEFINICIONES 39
2. AVISOS DE SEGURIDAD EN EL MANUAL 39
3. RECOMENDACIONES PRELIMINARES 39
3.1. VERIFICACION A LA RECEPCION .................................................................................................. 40
3.2. ALMACENAMIENTO......................................................................................................................... 40
3.3. DESCARTE Y RECICLAJE ............................................................................................................... 40
4. CERTIFICACIONES Y REGLAMENTACIONES 41
4.1. HOMOLOGACIÓN ANATEL .............................................................................................................. 41
4.2. REGLAMENTACIÓN FCC (EE.UU) .................................................................................................. 41
4.3. REGLAMENTACIÓN IC (CANADÁ) ................................................................................................. 42
5.4. DIRECTIVA DE EQUIPOS DE RADIO (UE) ..................................................................................... 42
5. CONFIGURACIÓN DEL GATEWAY 43
5.1. ORIENTACIONES INICIALES ........................................................................................................... 43
5.2. CONEXIÓN A INTERNET ................................................................................................................. 43
5.2.1. INFRAESTRUCTURA .................................................................................................................... 43
5.3. REGISTRO DEL GATEWAY ............................................................................................................. 44
5.4. CONFIGURACIONES DE CONEXIÓN ............................................................................................. 46
5.4.1. CONEXIÓN A LA RED DEL GATEWAY ........................................................................................ 46
5.4.2. LOGIN .......................................................................................................................................... 46
5.4.3. CONFIGURACIONES BÁSICAS ................................................................................................... 46
5.4.4. CONFIGURACIONES DE RED WI-FI ............................................................................................ 46
5.4.5. CONFIGURACIONES DEL MODEM USB 3G/4G (DONGLE) ...................................................... 47
6. INSTALACIÓN 48
6.1. INSTALACIÓN DEL CABLE ETHERNET Y PUESTA A TIERRA .................................................... 48
6.2. INSTALACIÓN DE LOS PLUGS DE SILICONA (GARANTIZAR SELLADOS) .............................. 48
6.3. INSTALACIÓN EN EL AMBIENTE DE OPERACIÓN ...................................................................... 48
7. CONFIGURACIÓN DE LOS SENSORES 49
8. INSTALACIÓN DE LA APLICACIÓN 51
9. ESPECIFICACIÓN TÉCNICA 51
10. CERTIFICADO DE GARANTÍA 52
1. DEFINICIONES
Sensor - A lo largo de esta manual, el término “sensor” es usado en referencia al dispositivo WEG Motor Scan
- dispositivo de monitoreo inteligente de las características del motor.
IoT (Internet of Things) – Se define como la tecnología que permite comunicación máquina a máquina (M2M)
vía internet para el intercambio de datos e informaciones para fines predefinidos.
App – Aplicación de celular.
Gateway – Equipo intermedio que utiliza recursos de Internet para conectar el sensor a la plataforma WEG IoT.
A lo largo de esta guía, el término “gateway” es usado en referencia al Gateway Cassia X1000.
Bluetooth – Tecnología de comunicación inalámbrica que interconecta y permite la transmisión de datos entre
ordenadores, teléfonos móviles y otros dispositivos a través de ondas de radio.
Ethernet Ethernet es una arquitectura de interconexión para redes de área local: red de área local (LAN).
PoE es la abreviatura de Power Over Ethernet, que es una tecnología que permite la transmisión de electricidad a través
de los cables de una red Ethernet.
Hotspot es el nombre de un lugar en particular donde una red inalámbrica (tecnología Wi-Fi) está disponible para su
uso.
Firmware Es el conjunto de instrucciones de funcionamiento programadas directamente en el hardware de un
dispositivo electrónico. Contiene la información de inicialización que permite que el dispositivo funcione correctamente.
2. AVISOS DE SEGURIDAD EN EL MANUAL
En este manual son utilizados los siguientes avisos de seguridad:
¡PELIGRO!
No considerar los procedimientos recomendados en este aviso puede llevar a la muerte, heridas
graves y daños materiales considerables. Puede también cancelar la garantía.
¡ATENCIÓN!
No considerar los procedimientos recomendados en este aviso puede llevar a daños materiales.
¡NOTA!
Informaciones importantes para el correcto entendimiento y el buen funcionamiento del producto.
3. RECOMENDACIONES PRELIMINARES
Este manual contiene las informaciones necesarias para la correcta instalación, configuración y uso del
gateway Cassia X1000 en conjunto con el sensor WEG Motor Scan (dispositivo de monitoreo inteligente de las
características del motor).
Fue desarrollado para ser utilizado por personas con capacitación o cualificación técnica adecuadas para
operar este tipo de producto.
No seguir las instrucciones del producto puede ocasionar accidentes operacionales, daños al medio ambiente,
al dispositivo, además de la cancelación de la garantía.
La correcta definición de las características del entorno y de la aplicación es de responsabilidad del usuario.
Durante el período de garantía del Gateway, los servicios de reparación, revisión y recuperación deben ser
realizadas por Asistentes Técnicos autorizados WEG para que la garantía siga vigente.
¡NOTA!
Siga las recomendaciones de instalaciones descritas en el ítem 3, 4 y 5.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

WEG Gateway X1000 User manual

Category
Gateways/controllers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI