Electrolux 726474 (RS06FW1F) Datasheet

Type
Datasheet

This manual is also suitable for

Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D02-D04
CGX2004-08 (page 1 of 1), 1
st
ed.
XX July 2004
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Subject
Inlet (Solenoid) Valve in UC and in HT
Model
Undercounter double skin (LS6E / WT30E) and Hood Type medium/high
capacity (LS9-10EA-14EA / WT55-65E)
Problem
None.
Reason
Inlet valves and valve holder standardization.
Action in
Factory
Since serial number 42800001 for Undercounter and since serial number
43000001 for Hood Type we have introduced following inlet valves:
OLD inlet valve NEW inlet valve
spare part code
where used flow rate case
spare part code
049452
Hood Type UK versions
LS9 / WT55 & LS14EA / WT65E
0L0121
Undercounter UK versions
LS6E / WT30E
5.5 l/min plastic
0L0567
049626
Atmospheric boiler versions (UK excluded)
LS6EA / WT30E & LS10EA-14EA / WT65E
10 l/min plastic
0L0568
048817
Pressure boiler versions
LS6EP & LS9 / WT55
20 l/min plastic
0L0566
0L0318 Japan versions
according to flow reducer
brass
0L0570
049509
LS6MCD (McDonald’s Australia)
LS14ASIA / WT65ASIA
0L0423 North America versions 208V/60Hz
0L0488 North America versions 240V/60Hz
according to flow reducer
brass
0L0569
Action in
Field
The inlet valves are interchangeable towards previous ones only replacing
also their stainless steel holder (so far not available as spare part).
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380636 riccardo.sartor@electrolux.it
  • Page 1 1

Electrolux 726474 (RS06FW1F) Datasheet

Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI