Midmark Handpieces are designed to provide reliable performance and durability in various dental procedures. These handpieces offer precise control and efficiency, making them a valuable addition to your dental armamentarium. The low-speed handpieces, available with or without swivel couplers, provide versatility for a range of applications. With speeds ranging from 0 to 20,000 RPM, these handpieces can handle tasks such as prophylaxis, restorative dentistry, and endodontics. The swivel coupler allows for increased maneuverability and comfort during procedures.

Midmark Handpieces are designed to provide reliable performance and durability in various dental procedures. These handpieces offer precise control and efficiency, making them a valuable addition to your dental armamentarium. The low-speed handpieces, available with or without swivel couplers, provide versatility for a range of applications. With speeds ranging from 0 to 20,000 RPM, these handpieces can handle tasks such as prophylaxis, restorative dentistry, and endodontics. The swivel coupler allows for increased maneuverability and comfort during procedures.

Maintenance and Infection Control
Equipment Alert
All Midmark Handpieces must be sterilized and lubricated after every patient. Frequent cleaning will prolong the life of the handpiece.
Step 2 MUST be performed after every patient because Lubrication will elongate the life and performance of the handpiece to
eliminate debris from within the Low Speed handpiece 002-1277-01 (0 -20,000 rpm). The O-ring on a the swivel coupler for item
002-1277-00 (0-5,000rpm) MUST be lubricated at least once a week.
After Each Procedure
003-2076-00 Rev.JA1 (9/18/20)
WARNING
Handpiece should be sterilized between patients to prevent cross-contamination
which could result in serious illness or death from infectious diseases.
To Clean Handpieces...
1) Detach handpiece from hose and remove heads from contra angle/straight attachments and if applicable Swivel Couplers. Remove all
burs, prophy cups, etc. from heads and straight attachments. Scrub handpiece with a soft brush and warm water to remove debris. Rinse
and dry.
2) Apply Midmark One Step Cleaner/Conditioner as follows:
(A) Clean/Condition Drive Air Port (Applicable for 002-1277-01 Low-Speed w/o Swivel 0-20,000 rpm).
Assemble spray tube onto spray can head by firmly pushing tube into conditioner can spray tip as far as possible.
Insert tube into drive air port of handpiece.
Direct handpiece away from your body and towards an absorbent towel. Depress handpiece conditioner can top to spray until
conditioner flows from both ends of handpiece head (1 to 2 seconds).
If overspray on towel appears discolored repeat spray for an additional two seconds. Remove handpiece and wipe excess
conditioner from handpiece with a clean dry towel.
(B) Clean/Condition Swivel (Applicable for 002-1277-00 Low-Speed w/o Swivel 0-5,000 rpm).
Remove the swivel coupler from the motor by pulling back on the release collar until the swivel pulls out of the motor connector.
Clean/Condition the swivel coupler O-rings.
Clean/Condition the motor swivel ring by applying Midmark One Step Cleaner/Conditioner to the joint between the swivel ring
and the motor.
(C) Operate (Applicable for ALL Low-Speed Handpieces)
Attach handpiece to hose and run for 8-12 seconds with a bur or prophy angle installed.
Wipeoexcessconditioner.
3) Seal items in separate sterilization bags. Remove bur or prophy angle from handpiece prior to sealing items in sterilization bags.
4) Sterilize in steam autoclave as follows:
Place handpiece(s) in sterilizer tray(s).
Sterilize at a temperature of 275 degrees Fahrenheit (135 degrees Celsius) for at least 20 minutes.
5) Immediately remove handpiece from autoclave or chemiclave. Allow to cool sufficiently prior to handling.
Troubleshooting
The inconvenience of handpiece downtime can often be avoided by following the common sense problem diagnosis and corrective action
procedures that follow. If the problem cannot be corrected using these procedures call Midmark Technical Service Department.
Problem Probable Cause Solution
Handpiece Stalls No/Low Air Pressure Check the air line to be sure that air is turned on and line is unob-
structed.
Speed/Direction Ring out of position Move ring to either forward or reverse position.
Chuck Housing Open Close the chuck housing by turning ring 1/4-turn clockwise.
Air line improperly seated. Reconnect air line to handpiece making sure the gasket is fully
contacted.
ChuckDiculttoopen/close Chuck housing screw missing. Replace chuck housing screw.
Speed/Directionringdicult
to turn
Improper lubrication
Moisture in the air line.
See lubrication instructions.
Swivel Coupler Installation and Maintenance Instructions (only for 002-1277-00 Low-Speed w/Swivel 0-5,000 rpm)
To attach the swivel coupler to the dental delivery tubing, grasp the swivel coupler by the “stem” sticking out of the front of the swivel coupler,
align the drive air and exhaust tubes with the correct outlets in the delivery tube receptacle and thread the tubing nut onto the swivel coupler.
Hand tighten the delivery tubing nut onto the swivel coupler body.
To attach the swivel coupler to the motor, pull back on the release collar and insert the swivel firmly into the motor connector. Release the
collar. Assure that the collar returns to its normal position and is up against the motor body. There must not be a gap between the motor and
the release collar.
To remove the motor from the swivel coupler, pull back on the release collar until the swivel pulls out of the motor connector.
The swivel coupler o-rings and the motor swivel ring should be lubricated daily with handpiece conditioner. For the motor swivel ring, the
lubricant should be applied to the joint between the swivel ring and the motor. Detach handpiece / motor from the swivel coupler at the end of
each day and prior to other extended periods of non-use.
The swivel coupler can be sterilized in a bag at the same temperatures as the other Midmark Low Speed components. Allow to cool down
after sterilization and prior to use.
Maintenance - Low Speed Handpiece (only for 002-1277-01 Low-Speed w/o Swivel 0-20,000 rpm).
Over time a build-up of debris inside the motor may affect the Midmark Low Speed handpiece performance. Apply Midmark one-step
handpiece cleaner/conditioner to the drive air inlet tube and run the handpiece for 8-10 seconds to flush the debris out of the motor between
patients. Like new performance should then be restored. Wipe the Midmark Low Speed handpiece with a clean, dry cloth or gauze to remove
excess oil.
To install or remove swivel coupler hold onto stem
of swivel coupler firmly while attaching it to tubing.
Handpiece
Tubing
Swivel
Coupler
Prophy
Angle
Handpiece
w/Swivel
Handpiece
w/o Swivel
Swivel
Coupler
Handpiece
w/Swivel
Handpiece
w/o Swivel
Drive Air Port -
Apply Cleaner/
Conditioner Here
Calling for Service
If service is required, contact your authorized Midmark dealer.
To contact Midmark directly:
1-800-MIDMARK (1-800-643-6275)
8:00 am until 5:00 pm Monday - Friday (EST)
www.midmark.com
70295
Minimum - 35 PSI (240 kPa)
Maximum - 50 PSI (345 kPa)
Installation
Service Parts
Midmark Corporation
60 Vista Drive
Versailles, OH 45380 USA
1-800-643-6275
1-937-526-3662
www.midmark.com
Print Style Special see le info
For Professional Use Only
This product is intended for use by Veterinary Professionals
only. Before operating handpiece, carefully read and follow
these instructions and save them for future reference. Observe
all cautions and warnings.
Operating & Care Guide
Midmark Low-Speed Instrument
Low-Speed w/Swivel 0-5,000RPM - 002-1277-00
Low-Speed w/o Swivel 0-20,000RPM - 002-1277-01
(Additional Nose Cone Required)
Limited Warranty Information
Midmark warrants that the Midmark
Low Speed handpieces are
of the highest quality material and workmanship. The Midmark
Low Speed straight handpieces and swivel adapter are fully
warranted against defective material and workmanship for one
(1) year from date of purchase. Midmark liability and the cus-
tomers sole remedy in the event of any claimed defect shall be
limited to repair or replacement of the merchandise at Midmark.
Additional Conditions of Warranty
1) The low speed handpiece system must be operated and
maintained in accordance with the procedures outlined in
this instruction booklet.
2) The low speed handpiece system must not be subjected
to abuse or neglect.
3) The low speed handpiece must not have been repaired
or disassembled by anyone other than Midmark.
The following parts can be ordered directly
from your authorized Midmark distributor.
Swivel Adapter 002-1291-00
Classic Elite Prophy Angle
002-1279-00 10 per pack
002-1279-02 100 per box
*Not Shown
Used On All Low-Speed Handpieces
*Gasket: 016-1308-00
*Conditioning Tubes (3): 053-2259-00
*Handpiece Conditioner Kit: 002-1432-00
*Handpiece Conditioner case (12): 002-1432-01
Used On Low-Speed Handpieces With Swivel
*Autoclavable Prophy angle 002-1159-00
*Prophy Cups 144 pack 002-1160-01
Used On Low-Speed Handpieces Without Swivel
*Rodent Burs and Guards Kit 002-1664-00
*Straight Nose Cone, 1:1 016-1605-00
*Straight Nose Cone, 4:1 016-1605-01
Installation Notes...
• This product is not sterile. Clean and sterilize before its first use. Follow sterilization
and maintenance instructions.
• Check air line filter in dental machine. If dirt or moisture is present, bleed system
and replace filter.
• Preset low-speed handpiece air pressure between 35 and 50 psi.
• If applicable secure Midmark Low Speed handpiece to swivel adapter. See Swivel
Coupler Installation Instructions for how to install swivel adapter and attach low
speed handpiece.
• Secure the handpiece bur or doriot attachment, if applicable, to the Low speed
handpiece, using directions found below.
• Set forward/reverse speed adjustment ring to any position other than neutral.
• Depress the foot control fully and adjust forward /reverse speed adjustment ring to
desired speed and direction.
Note: Midmark Low Speed handpiece will operate only when the nose cone chuck is in the closed position.
Important Safety Precautions
Equipment Alert
1) Use only concentric, handpiece burs in the Midmark
Low-Speeds. Do not use oversized, bent, grooved,
off-centered burs or diamond instruments.
2) Never attempt to force a bur or Doriot attachment into the
Midmark Low-Speed chucking system. If the shank does not
enter the handpiece easily, it is oversized and should not be
used.
3) The bur or attachment must be fully inserted in the Midmark
Low-Speed before operation.
4) Do not extend burs from handpieces, attachments or heads.
5) Never operate handpiece after head change or bur change
without double checking that the head and bur are securely
retained.
6) Never operate motors or handpieces at air pressure in excess
of recommended maximum setting.
7) Never operate the handpiece without the chuck in the closed
position.
8) Never submerge components in any cleaning solutions.
9) Do not use ultrasonic cleaners.
10) Do not sterilize for extended periods (such as overnight).
11) Do not leave handpiece components in sterilizer after cycle is
completed.
Placing & Removing Handpiece Burs or Doriot Attachments & Heads..
1) Holding the handpiece in your left hand, depress the chuck housing ring toward the body of the handpiece while twisting
1/4 - turn counter clockwise to open the chuck.
2) To install align Doriot slot with tab on housing. Then insert bur or Doriot attachment fully into the chuck housing
3) To remove pull out the bur or Doriot attachment to remove from chuck.
4) Return the ring to its original “locked” position by twisting 1/4 - turn clockwise.
5) Double check to be sure bur / attachment is securely locked in place.
Operating Recommendations
Air Pressure: The dental unit air pressure for low-speed handpiece should be adjusted between 35 and 50 psi.
Air Supply: Moist or dirty air from the compressor can damage the Midmark Low Speed handpieces. Check the filters often. If
dirt or moisture is present, replace the filter and bleed the system.
Empty Operation: The Midmark Low Speed handpiece will not operate unless the chucking system is fully engaged. This
minimizes risk of damage to the chuck.
Forward/Reverse Speed Direction Ring
The speed-direction ring can be rotated either clockwise for forward direction, or counter-clockwise for reverse. The more the
ring is turned away from the mid-position, the faster the operating speed. If the ring is in mid-position, the handpiece will not
operate.
Chuck Housing
Ring
Housing Tab
Forward/Reverse Speed
Direction Ring
  • Page 1 1
  • Page 2 2

Midmark Handpieces User guide

Type
User guide

Midmark Handpieces are designed to provide reliable performance and durability in various dental procedures. These handpieces offer precise control and efficiency, making them a valuable addition to your dental armamentarium. The low-speed handpieces, available with or without swivel couplers, provide versatility for a range of applications. With speeds ranging from 0 to 20,000 RPM, these handpieces can handle tasks such as prophylaxis, restorative dentistry, and endodontics. The swivel coupler allows for increased maneuverability and comfort during procedures.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI