Cotek SL series Quick start guide

Type
Quick start guide
Quick Product Introduction
SL series
SL Series
Scan QR Code to view
the User Manual
2000W / 3000W Low Frequency Pure Sine Wave
Inverter / Charger
Inverter Mode SL-2000-112 SL-3000-112
Charger Mode
Electrical
349 [13.74]
25 [0.98]
124 [4.88] 124 [4.88]
305 [12.01]
7 [0.28] 13 [0.51]
7 [0.28]
203 [7.99]
321 [12.64]
Please download and read the user manual from COTEK website or QR code before starting to use the
SL Inverter / Charger.
IMPORTANT: Please must read the Installation and Maintenance Instructions Before Connecting to the Supply.
Continuous Output Power
Frequency
Output Voltage
Max. Eciency
DC Voltage
Input Voltage Range
Output
Input
2000 VA ± 3%
60 Hz ± 0.1Hz
120 VAC ± 5%
>90%
12 VDC
9~17 VDC±0.3V
3000 VA ± 3%
Battery Temperature protection
AC Input Frequency Range
AC Input Current Range
AC Nominal Current
Charger eciency (peak)
Power Factor Correction (PFC)
Charging Current Range
Charger
By an RJ-11 connector to a battery temperature sensor
50 ~ 70 Hz
5 ~ 50A
(Setting by remote control)
15A
85%
> 0.97 (50% Load)
0 ~ 100A
18A
0 ~ 125A
Full Load
Power de-rating
Storag
Dimension (W x H x D)
Net Weight
Safety Standards
EMC Standards
Operating Temp. Range
Operating Humidity Range
Mechanical Specication
Safety and EMS
-20 ~ 40
60 W per , 41~60
-30 ~70
0~95% Non-condensing
321 x 203 x 349 mm / 12.64 x 7.99 x 13.74 inch
17.6 Kg (38.71 Lbs)
UL458 for Vehicle & Marine , Supplement SA
FCC Class B
EN55022:1998+A1:2000+A2:2003 Class B EN55024:1997+A1:2001+A2:2003
EN61000-3-2:2006 Class A EN61000-3-3:1995+A1:2001
22.6 Kg (49.82 Lbs)
Mechanical drawings (Unitmm [inch])
2020.11_A2
SL series
www.cotek.com.tw
Warning!
Do not open or disassemble the Inverter. Attempting to do so may cause risk of electrical shock or re.
We guarantee this product against defects in materials and workmanship for a period of 24 months from the date of purchase.
In case you need to repair or replace any defective power inverters, please contact COTEK local distributor.
This warranty will be considered void if the unit has been misused, altered, or accidentally damaged. COTEK is not liable for
anything that occurs as a result of the users fault.
Product Installation
Warranty
Product Appearance
-
+
AC INPUT
INV. AC
OUTPUT
NEG
POS
ON/OFF
REMOTE
BAT.
TEMP.
STATUS
ENB+
GND
ENB-
N.C
COM
N.O
S1
S2
S3
S4
INV. / CHR.
MODE
ON/OFF
BAT.
TEMP.
STATUS
ENB+
GND
ENB-
N.C
COM
N.O
S1
S2
S3
S4
INV. / CHR.
MODE
AC INPUT
INV. AC
OUTPUT
NEG
-
POS
+
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
DC Input Connection(-)
DC Input Connection(+)
Power Switch
INV./CHR. Mode LED Indicator
STATUS LED Indicator
DIP Switch Setting
RS-232 / Remote Control Port
Battery Temperature Sensor port
AC Input Connections
AC Output Connections
Chassis Ground
Remote Control Green Terminal
Dry Contact Green Terminal
LOAD
(120 VAC)
Utility power / Generator power
(120 VAC)
Battery Temperature Sensor
CR-20
Remote Control (Optional)
Battery
No.33, Sec. 2, Renhe Rd., Daxi Dist., Taoyuan City 33548, Taiwan
Phone +886-3-3891999 FAX +886-3-3802333
  • Page 1 1