GFS e-Bar 700 70 Series Assembly Instruction Manual

Type
Assembly Instruction Manual
GfS Safety at doors
GfS – Gesellschaft für Sicherheitstechnik GmbH
Tempowerkring 15 ∙ 21079 Hamburg ∙ Fon 040-79 01 95-0 ∙ Fax 040-79 01 95 11 ∙ [email protected]
Assembly instruction
GfS e-Bar®
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
3
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
Content
1. Introduction Seite
1.1.0 Safety information .....................................................................4
1.2.0 General functions ......................................................................5
1.3.0 Functions of GfS e-Bar® 730 73x/700 74x – Local alarm types ..................................6
1.3.0 Functions of GfS e-Bar® 730 73x/700 74x – Operation .........................................7
1.4.0 Versions of GfS e-Bar® – mechanical ......................................................8
1.4.1 Versions of GfS e-Bar® – mechatronic .....................................................9
2. Assembly
2.1.1 Mounting preperation of GfS e-Bar® ......................................................10
2.1.2 Cut to size with tool kit .................................................................11
2.2.0 Defining the correct length ..............................................................12
2.3.0 Adjust pre- and main alarm .............................................................13
2.4.0 Change the cylinder ...................................................................14
2.5.1 Mounting on wooden door with escutecheon furniture .......................................15
2.5.2 Mounting on metal door ................................................................16
2.5.3 Mounting in combination with security escutcheon (4mm) ....................................17
2.6.0 Battery operation/mains supply – wiring of GfS e-Bar® .......................................18
2.7.0 Assembly of GfS e-Bar® ................................................................19
2.8.0 Placing the stickers ....................................................................20
3. Electrical connection
Cable connection plan:
3.1.0 GfS e-Bar® mechanical with floating contact ...............................................21
3.1.2 mechatronic ..........................................................................22
3.1.3 Mechatronic with emergency exit switch ..................................................23
Terminal board
3.2.0 GfS e-Bar® 700 71x ....................................................................24
3.2.1 GfS e-Bar® 700 73x ....................................................................25
3.2.2 GfS e-Bar® 700 74x for electrically locked emergency exits ....................................26
4. Switching color to green or red ...............................................................27
5. Technical data ...............................................................................28
6. Maintenance
1 Service protocol (operator) ..............................................................29
2 Service protocol (installer) ..............................................................31
This document has been produced with the utmost care. GfS does not guarantee the accuracy or completeness of the content of this documentation with respect to texts, pictures , references orother infor-
mation contained therein. The company GfS assumes no liability for damages arising directly, indirectly or accidentally from the use of this documentation are product, personor economic damage. The con-
tent of this documentation may be adjusted without notice and does not represent obligation of the company GfS for the future.
© Copyright by GfS – Gesellschaft für Sicherheitstechnik GmbH – Hamburg 2012.
This documentation may be reproduced without written permission of GfS – Gesellschaft für Sicherheitstechnik GmbH in any way, or otherwise used.
*GfS e-Bar® mechanical has no display
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
4
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.0 Introduction
1.1.0 Safety information
The GfS e-Bar® is certified according to EN 1125 and EN 1634 and meets highest quality and safety standards. In order to keep the
GfS e-Bar® operational the door must be in a perfect state during and after installation.
To assure the correct functioning of the GfS e-Bar® and to maintain a safe emergency exit route the following guidelines have to be re-
spected:
•thedoorshallhaveasmoothoperationwithoutanydistortion
•thedoorleafshallbeplanarandstable
•theexistingdoorsealsshallnotaectthecorrectfunctioningofthedoor
•thedistancebetweendoorframeandlockfacingshallbebetween3and6mm
•thetwoexternalmountingpointshavetobepositionedatthesameheight
•theGfSe-Bar®hastobemountedhorizontallyonoutsideopeningdoors
•theGfSe-Bar®hastobemountedincombinationwithcertiedlocksandlockplates
•theGfSe-Bar®hastobemountedonthedoorleafwiththemax.possiblelength
•theinstallationonglassframeddoorsrequiressafetyglass
•theoperationonswing-doorsisprohibited
•lock,strike,bolthavetobemountedinawaythatassuresasafeengagementinthelockingplate
When changing the cylinder lock (European cylinder): employ cylinder with lockable cam.
The mounting has to be done by qualified personnel only.
After installation the assembly instruction has to be passed to the building operator.
Protect the GfS e-Bar® from humidity and vandalism!
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
5
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.2.0 General function/description
Function GfS e-Bar®
mechanic
700 70*
GfS e-Bar®
mechanic with
floating contact
700 71*
GfS e-Bar®
mechatronic
with integrated
alarm function
700 73*
GfS e-Bar®
mechatronic
with integrated
alarm function
and emergency
exit switch
700 74*
Communicating display
acoustic/visual
X X
for door leaf left/right X X X X
Battery driven (incl. battery control) X
External power supply X X
Main alarm with floating contact X X X
Pre-Alarm with floating contact X X X
Single release (local or remote) X X
Permanent release (local or remote) X X
Visual and acoustic “door-too-long-open” alarm X X
Intrusion alarm X X
Integrated emergency exit switch X
Changing display to green/red X X
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
6
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.3.0 Functions of GfS e-Bar® 70073x, 70074x
Local alarm types
GfS e-Bar® activated
When activated the display of the cabled GfS e-Bar® is permanently illu-
minated green. Green is signaling that the door is alarm secured but
might be opened at any time. In case of battery supply the GfS e-Bar®
works in an energy saving mode without background illumination. The
display shines for just about 15 sec. green and expires then.
Pre-alarm
While slightly pressing the GfS e-Bar® a red flashing light and an acoustic
alarm (95dBA/1m) is emitted, which expires as soon as the GfS e-Bar® is
released. The prealarm is activated just during the first mm of the pushing
movement. The correct moment when the pre-alarm is turning into a main
alarm can be adjusted by a regulating screw resp. in older versions of the
GfS e-Bar® by a reed contact (see operating manual page 8). It would be
ideal if the pre-alarm is set in a way that the main alarm is just activated
when the GfS e-Bar® is pushed to a point in which the door is released.
The pre-alarm can be transmitted to a central display
Main alarm in case of an unauthorized or an emergency passage
When pressing the GfS e-Bar® completely the door is released. At the
same time the display emits an intermittent green light and a permanent
alarmwith95dBA.Theacousticandvisualalarmcanbejustswitchedo
on the integrated key switch. The main alarm can be transmitted to a cen-
tral display. With remote technology the main alarm is transmitted via
channel 1.
Battery Control
When the GfS e-Bar® is battery supplied a gentle acoustic alarm in an in-
terval of 60 sec is emitted as soon as the voltage drops below 7 V. The
display is not shining. The alarm is active till a new battery is connected.
Door-too-long-open-Alarm
Pre-condition for this feature is a reed-contact which is installed
on the door and connected to the GfS e-Bar®. When the single re-
lease has been activated on the integrated key switch and the
door stays open for more than 15 sec. a gentle “door-too-long-
open-alarm” is emitted in an interval of 3 sec. This alarm indicates
that an authorized person has left the door open. As soon as the
door is closed the alarm expires.
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
7
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.3.0 Functions of GfS e-Bar® 70073x, 70074x
Operating the GfS e-Bar®
Deactivation of main alarm
The main alarm can just be deactivated by a) turning the key in the in-
tegrated key switch by 90° into the 12.00 o’clock position b) turning the
key back by 90°. Afterwards the key should be removed. 15 sec. after this
operation the GfS e-Bar® is activated again. The display shines perma-
nently green (external power supply) resp. for 15 sec. green and expires
then (battery powered). In case that a reedcontact is installed and con-
nected to the GfS e-Bar® , the GfS e-Bar® is activated again after the door
is closed. Attention: There is no possibility to deactivate the GfS e-Bar® by
an external switch!
Single release
By using the integrated key switch or by employing an external access
control system, an authorized person may pass the emergency exit once
without causing an alarm.
To achieve this the key switch has to be turned by 90° into the 12.00
o’clock position and turned back. The key should be removed. 15 sec. af-
ter this operation the GfS e-Bar® is activated again. The display shines
permanently green (external power supply) resp. for 15 sec. green and ex-
pires then (battery powered).
In case that a reed-contact is installed and connected to the GfS e-Bar®,
the GfS e-Bar® is activated immediately after the door is closed. With an
installed reed-contact a gentle “door-too-long-open-alarm” is emitted af-
ter the door has been left open for more than 15sec.
When closing the door again the alarm expires immediately. The gentle
“door-too-long-open-alarm” emits sounds in an interval of 3 sec. The sin-
gle release can be activated and deactivated by external access control
systems (see operating manual page 18). Alternatively the single passage
is possible by turning the key in the lock of the door.
Permanent release
By using the integrated key switch an authorized person may deactivate
the GfS e-Bar® in order to pass the emergency exit for a longer period of
time. When the permanent release is activated the door can be passed
without causing an alarm. The status is communicated by a rising and
ebbing of the green display. To achieve this the key in the key switch has
to be
a) turned by min. 90° into the 12.00 o’clock position for more than ca. 5
sec. and
b) turned back by 90°.
The key should be removed. The permanent release is activated till the
key is turned again by min. 90° into the 12.00 o’clock position and re-
moved afterwards. This status can be activated and deactivated by exter-
nal signals (timer, access control systems etc.). The status can be trans-
mitted to a central display (see operating manual page 18). With remote
technology the main alarm is transmitted via channel 2.
R
E
S
E
T
P
E
R
M
A
N
E
N
T
O
P
E
N
(
h
o
l
d
5
s
e
c
.
)
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
right
R
E
S
E
T
(
h
o
l
d
5
s
e
c
.
)
P
E
R
M
A
N
E
N
T
O
P
E
N
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
left
R
E
S
E
T
P
E
R
M
A
N
E
N
T
O
P
E
N
(
h
o
l
d
5
s
e
c
.
)
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
right
R
E
S
E
T
(
h
o
l
d
5
s
e
c
.
)
P
E
R
M
A
N
E
N
T
O
P
E
N
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
left
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
8
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.4.0 Versions of GfS e-Bar® mechanic
1. GfS e-Bar® mechanic
This model is a push-bar incl. a picto describing the operation of the GfS e-Bar®. Neither contacts nor electric functions are
included.TheGfSe-Bar®mechanicwillbesuppliedinthreedierentlengths,whichmightbeshortenedindividually,inorder
to adjust the length to the width of the door.
Length in mm To be shortened by mm Art.-No.
970 180 700 700
1130 160 700 703
1290 160 700 705
2. GfS e-Bar® mechanic with floating contacts
This model is a push-.bar with floating contacts to generate information on the usage of the push bar.
The items will be delivered with a picto describing the operation of the GfS e-Bar®. The GfS e-Bar® mechanic will be supplied
inthreedierentlengths,whichmightbeshortenedindividually,inordertoadjustthelengthtothewidthofthedoor.
Length in mm To be shortened by mm Art.-No.
970 180 700 710
1130 160 700 713
1290 160 700 715
970/1130/1290
15
15
6.5
43/50
71.3
84.7
9
To be shortened by 180/160/160 mm
Distance between fastening points
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
9
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
1.4.1 Versions of GfS e-Bar® mechatronic
1. GfS e-Bar® with integrated alarm (battery operated and/or wired)
This model works either with a 9 V battery which is controlled by the PCB or with an external power supply of 10-30VDC.
The battery control function checks every 10 hours the voltage. If the voltage drops below 7V, all 60 seconds an acoustic alarm is emitted.
The battery has to be exchanged. When battery operated the GfS e-Bar® works in an energy saving mode which basically means that the
greenLEDsofthedisplayareswitchedo.
TheintelligentPCBrecognizeswhenanexternalpowersupplyisconnectedtotheGfSe-Bar®.Theenergysavingmodeisswitchedo.
The display shines permanently green. It indicates that the emergency exit is secured and the alarm function is in operation.
Delivery includes 1 9V battery, 2 keys, 1 picto for the display and the key switch as well as one sticker explaining the operation on the door.
Length in mm To be shortened by mm Art.-No.
970 180 700 730
1130 160 700 733
1290 160 700 735
Power supply surface munted 901 366
Power supply flush mounted 700 006
2. GfS e-Bar® with integrated alarm and emergency exit switch for opening electrically locked doors
The power supply works with a 10-30 V DC. When connected to an emergency exit control unit the power is supplied by the emergency exit
control unit. The integrated emergency exit switch with 2 opening contacts might be connected to the emergency exit control unit, a central
display. Besides it is recommended to install additionally a reed-contact, in order to generate a signal that the door has been left open or that
somebody has entered the door from the outside.
Delivery includes 1 integrated emergency exit switch, 2 keys, 1 picto for the display and the key switch as well as one sticker explaining the
operation on the door.
Length in mm To be shortened by mm Art.-No.
970 180 700 740
1130 160 700 743
1290 160 700 745
Power supply surface munted 901 366
Power supply flush mounted 700 006
970/1130/1290
15
15
6.5
9
43/50
71.3
84.7
Display for GfS e-Bar® mechatronic
To be shortened by 180/160/160 mm
Distance between fastening points
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
10
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.0 Assembly
2.1.1 Mounting preperation of GfS e-Bar®
Countersunk screw M3 x 8 Clamping bolt
Lever arm
Lever arm
Lever arm
Cylinder head screw M5 x 20
2a
7a
9
4
7
7
7
10
1a
1
2
push-bar
base profil
While pressing the push-bar profile
4
remove the cylinder head screw M5x20
1
.
Tear the cover hood (1a) out of the bajonette joint towards the lock side.
GfS e-Bar® mechatronic
Remove the screw M3x8
9
, unlock the cover hood by turning the key clockwise
2a
.
GfS e-Bar® mechanic
While the push-bar is pressed
4
remove the cylinder head screw M5x8. Tear the cover hood
2
towards the hinge side.
Remove the protective shield
10
Lift the push-bar profile
4
up to its maximum. Hold the lever arm
7
with one hand and remove the
push-bar profile
4
from the clamping bolt in opposite direction
7a
.
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
11
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.1.2 Cut to size with tool kit (not included in scope of delivery)
Connection circuit board
(just mechatronic versions)
Assembly/disassembly
4 x M4 x 4
6
7
5
8
Length of base profile
1
Shortening tool for base profile
Art.-No. 770 712
Length of push-bar profile
2
Bow saw
Bench vice
Shortening tool for
push-bar profile
Lug
Bench vice
Lug
LD/LT ± 1 mm
Order length Length of base profile Length of push-bar profile
BA 940
BA-67 mm BA-104 mm
BA 1100
BA 1260
Push-bar profile LP ±1 mm
Base Profile LB ± 1 mm
Standard length
Standard length
165
always to be shortened
on the hinge side
Just mechatronic versions:
Remove carefully the plug of the ribbon cable
5
from the connection circuit board and store it well protected in the base profile. Loose the
slotted grub screws M4x4
6
and remove them together with the console. Keep the shims
8
as you need them again for the assembly.
ATTENTION:
The clamping area should be protected by wood/plastic material in order to avoid scratches on the surface of the profile!
Carefully cut the profile with a conventional metal saw along the lug. A straight cut is easier when pressing the blade slightly against the lug.
After shortening the profile bur the edges carefully in order to avoid injuries.
ATTENTION:
Do not employ "lubricants and ccolants" when shortening the mechatronic versions od the GfS e-Bar®. Metal chips must not stay in the
GfS e-Bar®. Danger of short-circuit! After shortening insert the console
7
into the base profile. Place the shims
8
(0,8mm thickness)
between the console and the base profile.
IMPORTANT:
The shims (8) are designed to avoid pressure marks and deformations by the clamp-connection. Fasten the four cylinder pins M4x4 (3) with a
torque betwenn 0.4Nm and max. 0.5Nm! Just mechatronic versions: Insert carefully the plug of the ribbon cable (5) into the connection circuit
board.
Tool kit
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
12
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
6.5
15
158 300
83.5
50
2.2.0 Defining the correct length
Distance between fastening points
Front vision
Rule of thumb for defining the correct length:
door inside width - 2x backset + 2x lockplate thickness + 30mm = GfS e-Bar® length
Distance between fastening points
Door inside width
Door handle height
Order length LG = BA + 30
Center of square follower
Order lengths Max. Einkürzbarkeit
970 mm 180 mm
1130 mm 160 mm
1290 mm 160 mm
BA
DM DM
Distance
Square follower
Backset
Front plate shape
Forend plate width
Forend plate length
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
13
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.3.0 Adjust pre- and main alarm
IMPORTANT:
moving the magnet by 1 mm corresponds to 5 mm touch bar compression movement.
Do not unscrew the pre-alarm screw too much. There is a risk of accidentally damaging the pre-alarm reed-contact.
1 + 2
automaticswitch-o
after 3 minutes
Jumper
2 + 3
permanent main alarm
till reset is done
tighten screw,
pre-alarm starts
later
pre-alarm screw
unscrew,
pre-alarm starts
earlier
Main-alarm
sooner later
Release magnet
main-alarm
90
Jumper to set alarm
mode of buzzer
Reed-Contact main-alarm
Reed-Contact pre-alarm
pre-alarm screw
Buzzer
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
14
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.4.0 Changing the cylinder
Mounting European profile cylinder (PHZ) Mounting Swiss round cylinder (RZ)
Use right drill holes
Use left drill holes
Battery holder
Attention:
Employ European profile cylinder with lockable cam.
Just remove key, put cam on 180°!
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
15
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.5.1 Mounting on wooden doors
(Metal cover sheet 770.013 for wooden doors are not included in shipment)
X
Image A
BA
19
Ø 18
38
43/50
21.5/25
Sunk-wood screw
Ø 5 x 25
Cylinder head screw
wood screw ø 5 x 25
Hinge side Lockside
Standard flat steel base plate
Cover plate
lock side
Cover plate hinge side
Thickness depending on escutcheon 3 mm, 4 mm, 6 mm)
Counter sunk screw M4x8
(respect max. length of screw)
Shoulder bolt M4 x 4
Attention:
When installing pay attention to the orientation
of the socket. Cam has to show downwards
Detail X
max. 10
13
Image B
Attention:
Cover clip of the standard flat steel base plate
has to be mounted before the cover hood is mounted.
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
16
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.5.2 Mounting on metal doors
Drillings for suitable
riveting nuts M5
Cylinder head screw M5 x12
Image A
BA
43/50
21.5/25
43/50
X
max. 10
13
Image B
shoulder bolt M4 x 4
Attention:
When installing pay attention to the orientation
of the socket. Cam has to show downwards
Detail X
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
17
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.5.3 Mounting in combination with security escutcheon (4 mm)
Hinge side Lockside
Cover plate hinge side
Counter sunk screw M4x8 (respect max. length of screw)
X
X
BA
Ø 18
43/50
21.5/25
Cylinder head screw wood screw ø 5 x 25
Escutcheon for GfS e-Bar®
Ø 18
BA
43/50
43/50
21.5/25
Escutcheon for GfS e-Bar®
Cylinder head screw M5 x 25
Drillings for suitable
riveting nuts M5
Standard flat steel base plate
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
18
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.6 Battery operation/mains supply Wiring of GfS e-Bar®
Cable length
drilling for connecting cable Ø 10
drilling for connecting cable Ø 10
100 ± 15 mm
Door handle height
Door handle height
15
15
0.5
0.5
DIN links
DIN rechts
Connection cable 12-wires
with tie
GfS Art.-No.: 770 719
Cable with tie to be fixed at last
Installation without cables Installation with cables
Plug with jumper. Just necessary
for battery operation. Remove
plug when mains supply.
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
19
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.7.0 Assembly of GfS e-Bar®
Clamping bolts
3
Soft counter pressure
4
Lever arm
1
Lever arm
1
Cylinder head screw M5 x 20
8
Sunk screw M5 x 20
9
push-bar
hinge sideLock side
base profile
2
7
5
7
6
Lift the lever arms
1
up to its maximum. Hold the lever arm with one hand and pull the push-bar profile
2
from the hinge side on the
clamping bolt
3
until the push-bar profile is engaged. Lift the lever arm with one hand, give some counter pressure on the push-bar
profile with the other hand in order to avoid that the push-bar snaps-out again.
Important: The push-bar profile must smoothely but noticably snap-in. Do not force the push-bar profile.
In case of doubt try again.
Put the protective shield
10
on the support bracket.
Insert the cover hood
7
in the bajonette joint and push it to the dead stop. Fix the cover hood with cylinder head screw M5x20
8
.
a) Mechtronic versions
7
: turn the key anti-clockwise. A noticable click indicates that the cover hood is locked.
b) Mechanic versions: Fix cover hoods with M5x8 cylinder head screws (like lock side).
GfS – Gesellschaft für Sicherheitstechnik mbH · Tempowerkring 15 · 21079 Hamburg
Tel. +49 40 - 79 01 95 0 · Fax +49 40 - 79 01 95 11 · info@gfs-online.com · www.gfs-online.com
20
IN CASE OF EMERGENCY
PUSH TO OPEN
www.gfs-online.com
EMERGENCY EXIT – ALARM PROTECTED
IN CASE OF EMERGENCY
PUSH TO OPEN
www.gfs-online.com
EMERGENCY EXIT – ALARM PROTECTED
IN CASE OF EMERGENCY
PUSH TO OPEN
www.gfs-online.com
EMERGENCY EXIT – ALARM PROTECTED
R
E
S
E
T
P
E
R
M
A
N
E
N
T
O
P
E
N
(
h
o
l
d
5
s
e
c
.
)
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
right
R
E
S
E
T
(
h
o
l
d
5
s
e
c
.
)
P
E
R
M
A
N
E
N
T
O
P
E
N
G
f
S
H
a
m
b
u
r
g
w
w
w
.
g
f
s
-
o
n
l
i
n
e
.
c
o
m
left
GfS Safety at doors
7007xx_MA_GfS e-Bar_2014_SN1-99_GB
2.8.0 Placing the stickers
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

GFS e-Bar 700 70 Series Assembly Instruction Manual

Type
Assembly Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI