Safety Precautions
Thefollowingaregeneralsafetyprecautionsthatarenotnecessarilyrelatedto
anyspecificpartorprocedure,anddonotnecessarilyappearelsewhereinthis
publication.Theseprecautionsmustbethoroughlyunderstoodandapplytoall
phasesofoperationandmaintenance.
WARNING
KeepAwayFromLiveCircuits
OperatingPersonnelmustatalltimesobservegeneralsafetyprecautions.Do
notreplacecomponentsormakeadjustmentstotheinsideofthetest
equipmentwiththehighvoltagesupplyturnedon.Toavoidcasualties,always
removepower.
WARNING
ShockHazard
DonotattempttoremovetheRF
transmissionlinewhileRFpowerispresent.
WARNING
DoNotServiceOrAdjustAlone
Undernocircumstancesshouldanypersonreachintoanenclosureforthe
purposeofserviceoradjustmentofequipmentexceptinthepresenceof
someonewhoiscapableofrenderingaid.
WARNING
SafetyEarthGround
Anuninterruptibleearthsafetyground
mustbesuppliedfromthemain
powersourcetotestinstruments.Groundingoneconductorofatwo
conductorpowercableisnotsufficientprotection.Seriousinjuryordeathcan
occurifthisgroundingisnotproperlysupplied.
WARNING
Resuscitation
Personnelworkingwithornearhighvoltagesshouldbefamiliarwithmodern
methods
ofresuscitation.
WARNING
RemovePower
Observegeneralsafetyprecautions.Donotopentheinstrumentwiththe
powerapplied.
SafetyPrecautions
ii
Safety Symbols
Note: Callsattentiontosupplementalinformation.
WARNING
Warningnotescallattentiontoaprocedure,whichifnotcorrectlyperformed,
couldresultinpersonalinjury.
CAUTION
Cautionnotescallattentiontoaprocedure,whichifnotcorrectlyperformed,
couldresultindamagetotheinstrument.
Thecautionsymbolappearsontheequipmentindicatingthereis
importantinformationintheinstructionmanualregardingthat
particulararea
8320SeriesTenuline®Attenuator
iii
Warning Statements
Thefollowingsafetywarningsappearinthetextwherethereisdangerto
operatingandmaintenancepersonnel,and arerepeatedhereforemphasis.
Seepages
6
and
8
.
Seepages
7
,
9
,and
10
.
Seepage
8
.
WARNING
Theventplugmustbeinstalledatalltimeswhentheunitisinoperationor
cooling.Alwayschecktoensureventplugisinstalledpriortooperation.
Failuretodothiscouldresultindamagetotheequipmentandendangerthe
operatorssaf ety.
WARNING
LeakingRFenergyisapotentialhealth
hazard.
Neverattempttoconnectordisconnectequipmentfromthetransmission
linewhileRFpowerisbeingapplied.
Severeburns,electricalshock,ordeathcanoccur.
WARNING
Usingtheattenuatorintheupperendofitspowerdissipationrangewillcause
thehousingtobecomehot!
Careshouldbeexercisedintouching
them.
SafetyPrecautions
iv
Caution Statements
Thefollowingequipmentcautionsappearinthetextwhenevertheequipmentis
indangerofdamage,andarerepeatedhereforemphasis.
CAUTION
Seepag
e
5
.
Seepages
7
and
8
.
Seepage
15
.
Seepage
16
.
Seepage
19
.
TheAtt
enuatorisdesignedtobeoperatedinthehorizontalposition,with
mountingbracketsdown.
Operationinanyotherorientationwillcauseinsufficientcoolingoftheunit
leadingtoprematurefailure.
CAUTION
Theinputandoutputendsoftheseattenuatorsareclearlylabeled.Donot
coupleanattenuatorbackwardstothedirectionofpo
werflow.Destructionof
theoutputresistorwillresult.
CAUTION
AvoidputtingdirectpressureontheInputconnector.Theinputconnector
maybeinadvertentlydamagedcausinginaccurateoperationorpremature
failure.
CAUTION
Usecarewhenremovingorinstallingendcovertoavoiddamagingendcover
sealortheoringsealontheRFout
putsection.
CAUTION
Donotoverfillthecoolanttankwithcoolant.Roommustbeallowedfor
expansionoftheheatedcoolant.
8320SeriesTenuline®Attenuator
v
Safety Statements
USAGE
ANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY
THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY
PROTECTION.
USO
EL USO DE ESTE INSTRUMENTO DE MANERA NO ESPECIFICADA
POR EL FABRICANTE, PUEDE ANULAR LA PROTECCIÓN DE
SEGURIDAD DEL INSTRUMENTO.
BENUTZUNG
WIRD DAS GERÄT AUF ANDERE WEISE VERWENDET ALS VOM
HERSTELLER BESCHRIEBEN, KANN DIE GERÄTESICHERHEIT
BEEINTRÄCHTIGT WERDEN.
UTILISATION
TOUTE UTILISATION DE CET INSTRUMENT QUI N’EST PAS
EXPLICITEMENT PRÉVUE PAR LE FABRICANT PEUT
ENDOMMAGER LE DISPOSITIF DE PROTECTION DE
L’INSTRUMENT.
IMPIEGO
QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO IN MODO
DIVERSO DA COME SPECIFICATO DAL PRODUTTORE LA
PROZIONE DI SICUREZZA POTREBBE VENIRNE COMPROMESSA.
SafetyPrecautions
vi
SERVICE
SERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED
PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO
NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO.
SERVICIO
LAS INSTRUCCIONES DE SERVICIO SON PARA USO EXCLUSIVO
DEL PERSONAL DE SERVICIO CAPACITADO. PARA EVITAR EL
PELIGRO DE DESCARGAS ELÉCTRICAS, NO REALICE NINGÚN
SERVICIO A MENOS QUE ESTÉ CAPACITADO PARA HACERIO.
WARTUNG
ANWEISUNGEN FÜR DIE WARTUNG DES GERÄTES GELTEN NUR
FÜR GESCHULTES FACHPERSONAL. ZUR VERMEIDUNG
GEFÄHRLICHE, ELEKTRISCHE SCHOCKS, SIND
WARTUNGSARBEITEN AUSSCHLIEßLICH VON QUALIFIZIERTEM
SERVICEPERSONAL DURCHZUFÜHREN.
ENTRENTIEN
L’EMPLOI DES INSTRUCTIONS D’ENTRETIEN DOIT ÊTRE RÉSERVÉ
AU PERSONNEL FORMÉ AUX OPÉRATIONS D’ENTRETIEN. POUR
PRÉVENIR UN CHOC ÉLECTRIQUE DANGEREUX, NE PAS
EFFECTUER D’ENTRETIEN SI L’ON N’A PAS ÉTÉ QUALIFIÉ POUR CE
FAIRE.
ASSISTENZA TECNICA
LE ISTRUZIONI RELATIVE ALL’ASSISTENZA SONO PREVISTE
ESCLUSIVAMENTE PER IL PERSONALE OPPORTUNAMENTE
ADDESTRATO. PER EVITARE PERICOLOSE SCOSSE ELETTRICHE
NON EFFETTUARRE ALCUNA RIPARAZIONE A MENO CHE
QUALIFICATI A FARLA.
8320SeriesTenuline®Attenuator
vii
About This Manual
Thismanualcoverstheoperatingandmaintenanceinstructionsforthe
followingmodels:
Changes to this Manual
Wehavemadeeveryefforttoensurethismanualisaccurate.Ifyoudiscoverany
errors,orifyouhavesuggestionsforimprovingthismanual,pleasesendyour
commentstoourSol on,Ohiofactory .Thismanualmaybeperiodicallyupdated.
Wheninquiringaboutupdatestothismanualrefertothepart
numberand
revisiononthe titlepage.
Chapter Layout
Introduction — Providesgeneralinformationaboutthe8320series
attenuators.
Theory of Operation — Describesindetailtheconstructionofthe8320
seriesattenuatorsandhowcoolingisachieved.
Installation — Providesinstructionsonhowtosetupthe8320series
attenuatorsforworryfreeoperation.
Operating Instructions — Detailsthestepsrequiredtosafelyoperatethe
8320seriesattenuators.
Maintenance — Providesroutinemaintenanceinspectionsandprocedures,
detailedtroubleshootingshouldmalfunctionsoccur,andstepbysteprepair
procedures.
Specifications — Givesdetailedspecificationsforeach8320seriesmodel,as
wellasacomprehensivelistofavailablereplacementpartsandoptionalRF
connectors.
8321 8322 8323 8325
viii
Table of Contents
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
SafetySymbols.............................................. ..
.. ii
WarningStatements............................ .................iii
CautionStatements
... ...........................................iv
SafetyStatements...
................................. ........... v
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
ChangestothisManual.
............... .......................... vii
ChapterLayout.......
............... .......................... vii
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GeneralDescription.......
................................. ...... 1
OperatingEnvironment.........
.............................. 1
RFConnectors..................
............................. 2
Chapter 2 Theory of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
AttenuatorConstruction...... ............
........................ 3
Cooling................. ........
............................... 3
CoolantExpansion .................
........................... 4
HeatDissipation.....................
......................... 4
Chapter 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
UnpackingandInspection.....................
.................... 5
Location................ .............
............... ........... 5
Mounting.................. .....
............................... 6
Setup....... ...........
............... ................... ...... 6
VentPlugInstallation(Model8325).....
............... ......... 6
Installingina50OhmLine...... ..............
................. 7
Chapter 4 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
NormalOperation..............................
................. 8
EmergencyShutdown ...............................
............. 9
8320SeriesTenuline®Attenuator
ix
Chapter 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RFAssemblyResistanceTest..................................... 10
DCResistanceMeasurement.
............... .................. 10
PreventiveMaintenance...............
............... ........... 12
PeriodicInspection.................. ....
............... ..... 12
CleanOutsideSurfaces...........................
............ 12
CleanConnectors....................................
........ 12
Troubleshooting................ .. .......................
....... 13
RepairProcedures ........... ..............................
..... 14
CoolantLeakageRepair....................................... 14
ReplaceRFConnector
................... ..................... 14
ReplaceCoolantTankOutputEndCoverSeal...
.................. 14
ReplaceCoolantTankInputOringSeal.........................
17
ReplaceRFAssembly ......................................... 18
CoolantLevelInspection..
............... ................... .. 18
Storage .............
............... ................... ........ 19
CustomerService......
............... .......................... 20
Shipping........
.............................................. 20
Chapter 6 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Specifications ..
................................ .. .............. 21
ReplacementParts
............... ................... ........... 22
AvailableQCTypeConnectors.
................................ 23
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1
Chapter 1 Introduction
General Description
TheSeries8320TenulineAttenuatorarelowreflectionresistancenetworksfor
useinreducingRFpowerin50ohmtransmissionlinesbyknownandcontrolled
amounts.See
"OutlineDrawing"onpage 2.
OverthefrequencyrangeofDCto500MHz,thepoweroutputwillbereduced
by30dB(99.9percent)±0.5dB.Upto500MHz,theinputVSWRwillnotexceed
1.1andtheoutputVSWR1.15.Theseattenuatorsareusefulforloweringahigh
inputRFpowerto
alevelsuitableforfeedingintoascope,frequencycounteror
similardevice.
Theyareselfcontainedinstrumentsthatrequirenoexternalsourceofpoweror
utilityservice.
Allmodelsareportableandhaveaconvenientcarryinghandlenestedamong
thecoolingfinsonthetopside.Ifdesiredtheattenuatormaybepermanently
mounted,see
"Mounting"onpa g e 6.
Operating Environment
TheTenulineAttenuatorsshouldbeoperatedinadustandvibrationfree
environment.
Theyrelyonlyonambientaircurrents,theseattenuatorswillsafelyabsorb,and
dissipate,uptotheirmaximumratedinputpower.Theradiatorshavingcooling
finsspacedevenlyalongtheirlengthstoefficientlydissipateheatgenerated
duringoperation.
Allowatleast6inches(150mm)ofclearancearoundtheunittoallowsufficient
convectionaircurrentsforadequateheatdissipation.Theambienttemperature
rangeshouldremainbetween‐40°Cand+45°C(40°Fand113°F)forproper
operation.See
"Specifications"onpage21fortheratedpower,dimensionsand
weightofthe attenuators.
8320SeriesTenuline®Attenuator
2
RF Connectors
TheSeries8320AttenuatorsareequippedwithaBirdQuickChange(QC)
connectors.
FemaleNtypeco
nnectorsarenormallysuppliedfortheinputandoutputbut
maybeconvenientlyandeasilyinterchangedwithotherBirdQCconnectors.See
"Ava ilableQCTypeConnectors"onpage23foralistofavailableconnectors.See
"ReplaceRFConnector"onpage14forreplacementinstructions.
Figure 1 Outline Drawing







 
!"
#$
 
%"
#$
&
'(""
%)$'
*!+
,)-,
./.#0%!#
#%
%1010








*!+
,)-,
./.#0%!#
#%
!10


$&$
+"2
#$03"
Note: Model8325isshowninFigure1.
3
Chapter 2 Theory of Operation
TheSeries8320maybeusedforthe isolationofpowersourcesuptotheir
maximumpowerratingandforlowlevelmonitoring.Thelowpowervalue
obtainedattheoutputoftheattenuatorcaneasilybefedintoanoscilloscopeor
terminatedinasmallRFloadresistor.
Attenuator Construction
TheSeries8320Attenuatorsaresymmetrical“Tpads,withthepower
distributiononthelegsbeingdifferent.Thevalueoftheresistanceoneachleg
varies;therefore,accordingtothepoweritistoabsorb.Ontheinputresistance
element,aproportionatelylargerresistorisofcourserequiredforitsmuch
greaterpowerdissipation.A“Tconfigurationisusedtoprovideequalinputand
outputimpedancesforthe 50ohmtransmissionlineattenuation.
Theinputresistorisjoinedtothe“Tlegjointinanexponentiallytapered
housingtoprovidealinearreductioninsurgeimpedancedirectlyproportional
tothedistancealongtheresistor.Theoutputresistorisenclosedinahousing
designedtoreturntheattenuatortothecharacteristicimpedanceof50ohms.
Thisarrangementproducesauniformandpracticallyreflectionlessattenuation
characteristicoverthestatedfrequenciesoftheattenuator.
Thissystemoffilmonceramiccylindricalresistorsimmersedinadielectric
coolantconstitutestheRFAssembly.Thedielectricconstantofthecoolingfluid
andthetaperedinputandoutputresistorhousingsprovidetheproperelectrical
characteristicsforthecoaxiallineattenuationthroughouttheinternalcircuitry.
Cooling
Thedielectriccoolantiscarefullychosenforitsdesirabledielectricproperties,to
whichthediametersoftheresistorsandhousingsarematched,andforitshigh
thermalstabilitycharacte ristics.
Thecoolantusedis10CTransformerOil,P/N5030.
Model8321requiresapproximately1pint(0.47liter)
Model8322,0.7gallons(2.65liter)
Model8323,0.35gallons(1.3liter)
Model8325,0.9gallons(3.4liter).
8320SeriesTenuline®Attenuator
4
Coolant Expansion
Models8321,8322and8323allowforexpansionofthecoolantbyusingunder
filledradiatortanksandaderatingoftheirloadcarryingcapacities.
Model8325includesanexpansiontankandaventpluglocatedontheoutput
endatthetop.Whenpowerisappliedtotheattenuator,thecoolantexpands
intotheexpansiontank,astheairintheexpansiontankiscompresseditis
allowedtoescapethroughtheventplug.
Heat Dissipation
HeatDissipationisaccomplishedbyconvection,thecoolingfluidcarriestheheat
generatedintheresistorelementstothewallsofthecoolanthousing.This
housingisencasedinasetofradiatingfinswhichareattachedtoitsouter
surface.Theseradiatingsurfacesdissipatetheheatofthecoolantinto
the
surroundingair.
5
Chapter 3 Installation
Unpacking and Inspection
1. Carefullyinspectshippingcontainerforsignsofdamage.
Iftheshippingcontainerisdamaged,donotunpacktheunit.
ImmediatelynotifytheshippingcarrierandBirdTechnologies .
Iftheshippingcontainerisnotdamaged,unpacktheunit.Save
shippingmaterialsforrepackaging.
2. Inspectunitforvisualsignsofdamage.
Note: Ifthereisdamage,immediatelynotifytheshippingcarrier
andBirdTechnologies.
Location
TheSeries8320TENULINE®Attenuatorsshouldbelocatedtoallowoperationin
thehorizontalpositiononly,withthehandleupandmountingbracketsdown.
Allowatleastsixinches(150mm)ofclearancearoundtheunitinanareawith
freelycirculatingambientair.Unimpededairflowofconvectionaircurrentsis
requiredforadequateheatdissipation.
Positiontheattenuatortopermit theshortestpossi blecablelengthsbetween
theunitandthetransmittingequipment.
Theattenuatorisnotintendedorrecommendedforoutdoorusewhereitwillbe
unprotectedandexposedtotheelements.
CAUTION
TheAttenuatorisdesignedtobeoperatedinthehorizontalposition,with
mountingbracketsdown.
Operationinanyotherorientationwillcauseinsufficientcoolingoftheunit
leadingtoprematurefailure.
8320SeriesTenuline®Attenuator
6
Mounting
Theattenuatorisdesignedforeitherportab le operationorfixedinstallation,
thatis,itmayoperatedwithorwithoutbeingsecuredtoabenchorother
horizontalsurface.
Model8321isequippedwithrubberbumperfeetwhich canberemovedfor
permanentmounting.Theholesaretappedfor832screws.
ForModels8322,8323and8325,thefrontandrearfinsaremadeofheavier
gaugematerialbentoutward90toformmountingflanges.Ateachcornerof
theseflangesisa9/32inch(7mm)diametermountinghole.Theholesare
arrangedinarectangle,see
"Specifications"onpage21forthedimensions.The
attenuatormaybesecuredtoahorizontalsurfaceusingcustomerprovided
screws,nutsandlockwashers.
Setup
Vent Plug Installation (Model 8325)
BeforeplacingtheModel8325Attenuatorintoservice,thesolidshippingplug,
P/N2450049mustberemovedandreplacedbythespringloadedventplug,
P/N2450094.Thetwoplugsarelinkedtogetherbyapieceofbeadchain.
1. Locatetheventholefortheplug,locatedonthetopneartherear.
SeeFigure1onpage 2.
2. Removetheshippingplug.
3. Verifythe ORingisinstalledontheventplug.
4. Installtheventplug
5. Retaintheshippingplugforuseintransportingtheattenuator.
Theshippingplugshouldbeplacedbackintheventholewheneverthe
attenuatoristobeshipped.TakecarenottolosetheORingseal.
WARNING
Theventplugmustbeinstalledatalltimeswhentheunitisinoperationor
cooling.Alwayschecktoensureventplugisinstalledpriortooperation.
Failuretodothiscouldresultindamagetotheequipmentandendangerthe
operatorssaf ety.
Installation
7
Installing in a 50 Ohm Line
Models8322,8323and8325arelabeledINPUTandOUTPUTontherespective
ends.
Model83
21islabeledontheoutputendonly.
Thepr
operendsoftheseattenuatorsmayalso beidentifiedbytheinput
connectorbeingmountedontheflatgoldcoloreddiscwhereastheoutput
connectorismountedontheroundedsilvercoloreddome.
CAUTION
1. Performth
eRFAssemblyTestontheAttenuator,see"RFAssembly
ResistanceTest"onpage 10.
2. Connectthetr
ansmittingequipmentundertesttotheinputofthe
attenuator.
Use50ohmco
axialcabling(RG8A/U,RG9/U,RG213/Uorequivalent)
equippedwithplugswhichmatewiththeconnectorsontheattenuator.
3. Connecttheoutputtoas
uitableload.
4. Proceed acc
ordingto"OperatingInstructions" onpa ge 8.
Note: Whenre
connectingtheantenna,itmaybecomenecessary
toslightlyreadjustthetransmitterduetopossibledifferencesin
VSWRbetweentheattenuatorandtheantennasystem.
WARNING
LeakingRFenergyisapotentialhealthhazard.
Neverattempttoconnectordisconnectequipmentfromthetransmission
linewhileRFpowerisbeingapplied.
Severebu
rns,electricalshock,ordeathcanoccur.
Theinp
utandoutputendsoftheseattenuatorsareclearlylabeled.Donot
coupleanattenuatorbackwardstothedirectionofpowerflow.Destructionof
theoutputresistorwillresult.
8
Chapter 4 Operating Instructions
TheSeries8320TENULINE®Attenuatorsshouldfunctionfaultlessly,absorbing
andconverting RFenergyintoheatindefinitely,iftheyareproperlymaintained
andnotsubjectedtoanoverload.
Normal Operation
Note: TheSeries8320TENULINE®Attenuatorsarenotintendedor
recommendedforoutdoorusewheretheywillbeunprotectedand
exposedtotheelements.
1. Installtheattenuatorinthetransmissionline,see"Installingin a50Ohm
Line"onpage 7.
2. (Model8325)VerifytheVentPlughasbeeninstalled,see"VentPlug
Installation(Model8325)"onpage6.
3. Proceed accordingtothetransmittermanufacturersinstructions.
Theattenuatormaybesubjectedtoverymoderateoverloadsforlimited
periodsoftimewithoutoverheating.However,thisshouldbedonevery
cautiouslytoguardtheattenuatoragainstthedangersofoverheating.
CAUTION
Theinputandoutputendsoftheseattenuatorsareclearlylabeled.Donot
coupleanattenuatorbackwardstothe
directionofpowerflow.Destructionof
theoutputresistorwillresult.
WARNING
Theventplugmustbeinstalledatalltimeswhentheunitisinoperationor
cooling.Alwayschecktoensureventplugisinstalledpriortooperation.
Failuretodothiscouldresultindamagetotheequipmentand
endangerthe
operatorssaf ety.
WARNING
Usingtheattenuatorintheupperendofitspowerdissipationrangewillcause
thehousingtobecomehot!
Careshouldbeexercisedintouchingthem.
OperatingInstructions
9
Emergency Shutdown
Shouldtherebeanyabnormaloperationorfailureoftheattenuator,shutdown
thetransmitterimmediatelyandallowtheunittocoolbeforeperformingany
maintenance.
1. DisableRFpoweratthetransmitter.
WARNING
LeakingRFenergyisapotentialhealthhazard.
Neverattempttoconnectordisconnectequipmentfromthetransmission
linewhileRFpowerisbeingapplied.
Severeburns,electricalshock,ordeathcanoccur.
10
Chapter 5 Maintenance
RF Assembly Resistance Test
Note: Thesetestsarebynomeansanecessitytotheoperationof
theattenuatorbutmerelyguidelinesfortheusersinformation.
AccuratemeasurementoftheDCresistancebetweentheinputtoground,
outputtoground,andinputtooutputwillprovideagoodcheckofthecondition
oftheattenuator.
CheckingtheDCresistanceissimplyusedtomeasureachangeintheresistance
overtime.TrackingtheDCresistanceshouldstartbefore theunitisfirstputinto
service.Performthefollowingstepsandrecordthevalueforfuturecomparison.
Resistancemeasurementsshouldbetakenperiodicallyaccordingtouse.
Preparation:
Tools:Commonhandtools.
Ohmmeterwithanaccuracyof±1%at50ohms(orusearesistance
bridge).
Uselowresistanceleads,preferablyashortpieceof50ohmcoaxial
cablefittedwithanappropriateconnectororalligatorclips.
Temperatureoftheattenuatorshouldbestabilizedbetween20°Cto
25°C(68°Fto77°F).
DC Resistance Measurement
Note: Itisrecommendedthatthisresistancecheckbeperformed
eachtimetheattenuatoristobeused.
1. TurnoffRFpowerbeforemakinganydisconnections.
2. DisconnecttheRFcoaxialline.
3. Take thefollowingmeasurements:
WARNING
NeverattempttoconnectordisconnectRFequipmentfromthetransmission
linewhileRFpowerisbeingapplied.
LeakingRFenergyisapotentialhealthhazard.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

BIRD 8325 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI