Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual
www.PressureSystems.com
- vii -
Table of Contents (Cont.)
3.1.2 Commands ...............................................3-2
3.1.2.1 General Command Format .............................3-2
3.1.2.2 Command Field .....................................3-3
3.1.2.3 Position Field ....................................... 3-3
3.1.2.4 Datum Fields .......................................3-4
3.1.2.5 Format Field ........................................3-4
3.1.3 Responses ................................................3-4
3.1.3.1 Interpreting Offset Values (Re-zero Calibration Adjustment) ..3-5
3.1.3.2 Interpreting Gain Values (Span Calibration Adjustment) ..... 3-6
3.1.3.3 Interpreting Engineering Unit Output .................... 3-6
3.1.4 Functional Command Overview ..............................3-6
3.1.4.1 Startup Initialization ............................3-6
3.1.4.2 Module Data Acquisition ..............................3-7
3.1.4.3 Calibration Adjustment of Offset/Gain
Correction Coefficients .........................3-8
3.1.4.4 Delivery of Data to Host ..............................3-9
3.1.4.5 Network Query and Control Functions ...................3-9
3.1.4.6 Other Functions ....................................3-10
3.2 Detailed Command Description Reference ...........................3-10
A Power Up Clear ..........................................3-12
B Reset ...................................................3-13
C Configure/Control Multi-Point Calibration .....................3-14
V Read Transducer Voltages ..................................3-22
Z Calculate and Set Gains ....................................3-24
a Read Transducer A/D Counts ............................... 3-26
b Read High-Speed Data ..................................... 3-28
c Define/Control Autonomous Host Streams .....................3-29
h Calculate and Set Offsets ...................................3-45
m Read Temperature Counts ..................................3-47
n Read Temperature Voltages .................................3-49
q Read Module Status .......................................3-51
r Read High-Precision Data ..................................3-54
t Read Transducer Temperature ............................... 3-56
u Read Internal Coefficients ..................................3-58
v Download Internal Coefficients .............................. 3-62
w Set Operating Options .....................................3-65
psi9000 Network Query .....................................3-69
psireboot Re-boot Module .................................... 3-71
psiarp Change Module’s IP Address Resolution and Re-boot ......3-72