  • Hello! I'm here to assist you with the Peerless wall mount installation and assembly manual. This document provides detailed instructions for mounting the PANA-85WM model, compatible with TH-85PF12U and TH-85VX200U displays. It covers hardware requirements, mounting options for various wall types, and steps for both landscape and portrait installations, including tilt adjustment options. I can answer your questions about installation, load capacity, or other details available in the manual.
  • What is the maximum load capacity of this wall mount?
    What types of wall construction is this mount compatible with?
    Can this mount be used outdoors?
    What orientations does this wall mount support?
1 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Model: PANA-85WM
Installation and Assembly:
Wall Mount for Panasonic TH-85PF12U and TH-85VX200U
Landscape
Portrait
Maximum Load Capacity:
270 lb (122 kg)
2 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Triple Wood Stud Wall ......................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Installing Tilt Brackets .............................................................................................................................................................7
Mounting and Removing Flat Panel Screen ...........................................................................................................................8
IMPORTANT! Read instruction sheet before you start installation and assembly.
• DonotbegintoinstallyourPeerlessproductuntilyouhavereadandunderstoodtheinstructionsandwarnings
containedinthisInstallationSheet.Ifyouhaveanyquestionsregardinganyoftheinstructionsorwarnings,forUS
customerspleasecallPeerlesscustomercareat1-800-865-2112,forallinternationalcustomers,pleasecontact
yourlocaldistributor.
• Thisproductshouldonlybeinstalledbysomeoneofgoodmechanicalaptitude,hasexperiencewithbasicbuilding
construction,andfullyunderstandstheseinstructions.
• Makesurethatthesupportingsurfacewillsafelysupportthecombinedloadoftheequipmentandallattached
hardwareandcomponents.
• NeverexceedtheMaximumLoadCapacity.Seepageone.
• Ifmountingtowoodwallstuds,makesurethatmountingscrewsareanchoredintothecenterofthestuds.Useof
an"edgetoedge"studnderishighlyrecommended.
• Alwaysuseanassistantormechanicalliftingequipmenttosafelyliftandpositionequipment.
• Tightenscrewsrmly,butdonotovertighten.Overtighteningcandamagetheitems,greatlyreducingtheirholding
power.
• Thisproductisintendedforindooruseonly.Useofthisproductoutdoorscouldleadtoproductfailureandpersonal
injury.
• Thisproductwasdesignedtobeinstalledonthefollowingwallconstructiononly;
WALL CONSTRUCTION HARDWARE REQUIRED
 •Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
•MetalStud   ContactQualiedProfessional
•Brick    ContactQualiedProfessional
•Otherorunsure?   ContactQualiedProfessional
WARNING
3 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
AB C
F
D
E JH KG I L
Description Qty. Part #
A
wallplate 1 201-1697
Btilt plate 1 201-1695
Csupport tube 2 201-1693
Dadapter bracket 2 201-1692
Erectangle cap 4 590-1334
FM8x15mmphillipsscrew 18 520-9257
GM5x8mmphillipsscrew 2 570-0005
H8mmanchor 9 590-0320
I#14x2.5woodscrew 9 5S1-015-CO3
J5/16splitwasher 18 540-9405
K5/16washer 18 540-9406
Llock bracket 2 201-1698
Parts List
4 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Installation to Triple Wood Stud Wall
Useastudndertolocatetheedgesofthestuds.Useofanedge-to-edgestudnderishighlyrecommended.
Basedontheiredges,drawaverticallinedowneachstud’scenter.Placewallplate(A)onwallasatemplate.
Levelplate,andmarkthecenteroftheninemountingholes.Makesurethatthemountingholesareonthestud
centerlines.Drillnine5/32"(4mm)dia.holes2.5"(64mm)deep.Makesurethatthewallplateislevel,secureit
usingnine#14x2.5"woodscrews(I)asshown.
Skip to step 2.
• Installermustverifythatthesupportingsurfacewillsafelysupportthecombinedloadoftheequipmentandall
attachedhardwareandcomponents.
• Tightenwoodscrewssothatwallplateisrmlyattached,butdonotovertighten.Overtighteningcandamagethe
screws,greatlyreducingtheirholdingpower.
• Nevertighteninexcessof80in.•lb(9N.M.).
• Makesurethatmountingscrewsareanchoredintothecenterofthestud.Theuseofan"edgetoedge"studnder
ishighlyrecommended.
• Hardwareprovidedisforattachmentofmountthroughstandardthicknessdrywallorplasterintowoodstuds.Install-
ersareresponsibletoprovidehardwareforothertypesofmountingsituations.
WARNING
1
A
I
5 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
solid concrete
cinder block
Installation to Solid Concrete or Cinder Block
• WheninstallingPeerlesswallmountsoncinderblock,verifythatyouhaveaminimumof1-3/8"(35mm)ofactual
concretethicknessintheholetobeusedfortheconcreteanchors.Donotdrillintomortarjoints!Besuretomount
inasolidpartoftheblock,generally1"(25mm)minimumfromthesideoftheblock.CinderblockmustmeetASTM
C-90specications.Itissuggestedthatastandardelectricdrillonslowsettingisusedtodrilltheholeinsteadofa
hammerdrilltoavoidbreakingoutthebackoftheholewhenenteringavoidorcavity.
• Concretemustbe2000psidensityminimum.Lighterdensityconcretemaynotholdconcreteanchor.
• Makesurethatthewallwillsafelysupportfourtimesthecombinedloadoftheequipmentandallattachedhardware
and components.
WARNING
1
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
drywall
plaster/
drywall
concrete concrete
1
3
2
H
Drillholesandinsertanchors(H).
Place plate (A)overanchors(H)andsecurewithscrews(I).
Tightenallfasteners.
A
H
I
concrete
surface
• Tightenscrewssothatwallplateisrmlyattached,
but do not overtighten.Overtighteningcandamage
screws,greatlyreducingtheirholdingpower.
• Nevertighteninexcessof80in.•lb(9N.M.).
• Alwaysattachconcreteexpansionanchorsdirectly
to load-bearing concrete.
• Neverattachconcreteexpansionanchorsto
concretecoveredwithplaster,drywall,orother
nishingmaterial.Ifmountingtoconcretesurfaces
coveredwithanishingsurfaceisunavoidable,
thenishingsurfacemustbecounterboredas
shownbelow.Besureconcreteanchorsdonot
pullawayfromconcretewhentighteningscrews.If
plaster/drywallisthickerthan5/8"(16mm),custom
fastenersmustbesuppliedbyinstaller.
WARNING
Makesurethatwallplate(A)islevel,useitasa
templatetomarkninemountingholes.Drillnine5/16"
(8mm)dia.holestoaminimumdepthof2.5"(64mm).
Insertanchors(H)inholesushwithwallasshownin
gure1.1.Placewallplateoveranchorsandsecure
withnine#14x2.5"screws(I).Level,thentightenall
fastenersasshowning.1.2.
H
IA
Fig. 1.1
Fig. 1.2
6 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Securetwosupporttubes(C) to tilt plate (B)usingfourM8x15mmphillipsscrews(F),four5/16splitwashers(J),
andfour5/16washers(K).
Securefourrectanglecaps(E) to support tubes (C)asshown.
2
3
Landscape Portrait
Landscape Portrait
B
FJK
B
FJK
D
CC
Securetwoadapterbrackets(D) to support tubes (C)usingeightM8x15mmphillipsscrews(F),eight5/16split
washers(J),andeight5/16washers(K)tocreatebracketassembly.
NOTE:Besurekeyholespointdown.
E
E
FJK
FJK
D
C
C
Keyhole
Keyhole
7 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Tomakesurebracketassemblykeyholeareproperlyalignedwithstandoffs,positionbracketassembly
ontodisplaystandoffs.
Removebracketassemblyfrombackofdisplay.
Secure tilt plate (B)ofbracketassemblytowallplate(A)atdesiredtiltangleusingsixM8x15mmphillipsscrews
(F),six5/16splitwashers(J),andsix5/16washers(K).SecureoneM8x15mmphillipsscrews(F),5/16split
washer(J),and5/16washer(K)intoslotoftiltplate(B)asshowninDetail1.
4
5
Landscape Portrait
F
J
K
F,J, and K
F
J
K
A
B
A
B
10°
Slot
Display
MountingSurface
NotShownforClarity
B
Detail 1
8 of 8 ISSUED: 12-18-09 SHEET #: 125-9090-4 03-24-11
Hookdisplaystandoffsintokeyholeslotsonadapterbrackets(D)ofbracketassembly.
NOTE:Makesurethatstandoffsrestatthebottomofkeyholeslotsasshownindetail2.
Securedisplaystandoffsinkeyholeusingtwolockbrackets(L)andM5x8mmphillipsscrews(G)
asshownindetail3.
6
Detail 2
Keyhole
DisplayStandoff
Detail 3
D
L
Display
G
L
MountingSurface
NotShownforClarity
Landscape
Portrait
Detail 2
Detail 3
MountingSurface
NotShownforClarity
Display
Keyhole
DisplayStandoff
L
G
L
/