Installation and Assembly:
Full Service Video Wall Mount
Model: DS-VW760
EXTENDED
COLLAPSED
Maximum Load Capacity: 150 Ib ( 68 kg)
2 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Table of Contents
Horizontal and Vertical Video Wall Mount Assembly Formula ................................................................................................3
Parts List.................................................................................................................................................................................4
Mounting and Removing Flat Panel Screen ...........................................................................................................................8
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall ................................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Installing Tilt Brackets .............................................................................................................................................................6
Mounting and Removing Flat Panel Screen
NOTE: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
studnder("edgetoedge"studnderisrecommended)
• phillips screwdriver
drill
• 5/16"(8mm)bitforconcreteandcinderblockwall
• 5/32"(4mm)bitforwoodstudwall
• level
• DonotbegintoinstallyourPeerlessproductuntilyouhavereadandunderstoodtheinstructionsandwarnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• Thisproductshouldonlybeinstalledbysomeoneofgoodmechanicalaptitude,hasexperiencewithbasicbuilding
construction, and fully understands these instructions.
• Makesurethatthesupportingsurfacewillsafelysupportthecombinedloadoftheequipmentandallattached
hardware and components.
• NeverexceedtheMaximumLoadCapacity.Seepageone.
• Ifmountingtowoodwallstuds,makesurethatmountingscrewsareanchoredintothecenterofthestuds.Useof
an"edgetoedge"studnderishighlyrecommended.
• Alwaysuseanassistantormechanicalliftingequipmenttosafelyliftandpositionequipment.
• Tightenscrewsrmly,butdonotovertighten.Overtighteningcandamagetheitems,greatlyreducingtheirholding
power.
• Thisproductisintendedforindooruseonly.Useofthisproductoutdoorscouldleadtoproductfailureandpersonal
injury.
• Thisproductwasdesignedtobeinstalledonthefollowingwallconstructiononly;
WALL CONSTRUCTION HARDWARE REQUIRED
•Wood Stud Included
Wood Beam Included
Solid Concrete Included
CinderBlock ContactQualiedProfessional
•MetalStud ContactQualiedProfessional
•Brick ContactQualiedProfessional
•Otherorunsure? ContactQualiedProfessional
WARNING
Accessories
DS-ACC760 Cable Release Kit
• DS-VWS0## Wall Plate Spacer Kit
3 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Accessories
DS-ACC760 Cable Release Kit
• DS-VWS0## Wall Plate Spacer Kit
If DS-VWS0## Wall Plate Spacer Kit is not available use diagram below to determine vertical spacing.
If DS-VWS0## Wall Plate Spacer Kit is not available use diagram below to determine horizontal spacing.
Todetermineedgeofsecondmount,add(Z)toedgeorrstmount.
WIDTH
Vertical Spacing Location
Horizontal Spacing Location
H
Vertical Location
X - 10.25 + (.938 OR 1.688) = (Y1 OR Y2)
DISPLAY WIDTH - (35) = Z (SPACING BETWEEN MOUNTS)
Horizontal Location
DISPLAY WIDTH
DISPLAY
HEIGHT
X
Y2
Y1
.938
1.688
10.25
16.00"
20.00"
24.00"
17.50"Z
Todeterminelowermountingslotpositionofsecondmount,adddisplayheightto(Y1)or(Y2)
4 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Openvideowallmountassemblybyreleasinglockingtab.Pullorpushup
on locking tab.
A
1
B C
D E F G
H I J K
PartsList
Description Qty. Part#
A pulloutmountassembly 1 1451104
B adapterbracket 2 1451105
C lockbracket 2 1451091
D M5x10mmsocketpintypeFscrew 2 5201164
E #14x2.5"hexheadwoodscrew 4 5S1015C03
F concreteanchor 4 5900320
G fenderwasher 4 5401008
H nylonshoulderwasher 4 5902233
I M6x12mmphillipsscrew 4 5201128
J M8x15mmphillipsscrew 4 5209257
K 4mmallenwrench 1 5609646
L cabletie(notshown) 2 5609711
M meshsleeve(notshown) 1 6001014
VIDEOWALL
MOUNTASSEMBLY
PULL UP
PUSH UP
LOCKINGTAB
LOCKINGTAB
5 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Remove display carriage by removing clip, pull release pin, and screws as shown. Remove screws using
4mmallenwrench(K).
2
Removing Display Carriage
LOCKINGTAB
LOCKINGTAB
VIDEOWALL
MOUNTASSEMBLY
DISPLAY CARRIAGE
VIDEOWALL
MOUNTASSEMBLY
DISPLAY CARRIAGE
CLIP
RELEASEPIN
SCREWS
E
G
Installation to Wall Stud
Useastudndertolocatetheedgesofthestud.Useofanedge-to-edgestudnderishighlyrecommended.
Based on their edges, draw a vertical line down the stud center. Place video wall mount assembly on wall as a
template. Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on
thestudcenterline.Drillfour5/32"(4mm)dia.holes2-1/2"(65mm)deep.Makesurethatthevideowallmount
assemblyislevel,secureitusingfour#14x2.5"woodscrews(E)andfenderwashers(G)asshownbelow.
• Installermustverifythatthesupportingsurfacewillsafelysupportthecombinedloadoftheequipmentandall
attached hardware and components.
• Tightenwoodscrewssothatwallplateisrmlyattached,butdonotovertighten.Overtighteningcandamagethe
screws, greatly reducing their holding power.
• Nevertighteninexcessof80in.•lb(9N.M.).
• Makesurethatmountingscrewsareanchoredintothecenterofthestud.Theuseofan"edgetoedge"studnder
is highly recommended.
• Hardwareprovidedisforattachmentofmountthroughstandardthicknessdrywallorplasterintowoodstuds.Install-
ers are responsible to provide hardware for other types of mounting situations.
WARNING
3
VIDEOWALL
MOUNTASSEMBLY
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
6 of 14
E
F
G
solid concrete
cinder block
VIDEOWALL
MOUNTASSEMBLY
Installation to Solid Concrete or Cinder Block
• WheninstallingPeerlesswallmountsoncinderblock,verifythatyouhaveaminimumof1-3/8"(35mm)ofactual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
inasolidpartoftheblock,generally1"(25mm)minimumfromthesideoftheblock.CinderblockmustmeetASTM
C-90specications.Itissuggestedthatastandardelectricdrillonslowsettingisusedtodrilltheholeinsteadofa
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concretemustbe2000psidensityminimum.Lighterdensityconcretemaynotholdconcreteanchor.
• Makesurethatthewallwillsafelysupportfourtimesthecombinedloadoftheequipmentandallattachedhardware
and components.
WARNING
1
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
F
Drillholesandinsertanchors(F).
Placeplate(A)overanchors(E)andsecurewithscrews(F).
Tighten all fasteners.
A
F
E
concrete
surface
• Tightenscrewssothatwallplateisrmlyattached,
but do not overtighten.Overtighteningcandamage
screws, greatly reducing their holding power.
• Nevertighteninexcessof80in.•lb(9N.M.).
• Alwaysattachconcreteexpansionanchorsdirectly
to load-bearing concrete.
• Neverattachconcreteexpansionanchorsto
concrete covered with plaster, drywall, or other
nishingmaterial.Ifmountingtoconcretesurfaces
coveredwithanishingsurfaceisunavoidable,
thenishingsurfacemustbecounterboredas
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywallisthickerthan5/8"(16mm),custom
fasteners must be supplied by installer
WARNING
Make sure that video wall mount assembly is level,
use it as a template to mark four mounting holes.
Drillfour1/4”(6mm)dia.holestoaminimumdepth
of2.5”(64mm).Insertanchors(F)inholesush
withwallasshown(right).Placevideowallmount
assembly over anchors and secure with four #14
x2.5”screws(E),andfenderwashers(G).Level,
then tighten all fasteners.
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
7 of 14
8 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Secure display carriage by pulling release pin, fastening clevis pin, clip, four screws, and spacer as shown.
NOTE: make sure that spacer is in-between display carriage and video wall mount assembly.
Re-Attaching Display Carriage
4
VIDEOWALL
MOUNTASSEMBLY
DISPLAY CARRIAGE
CLIP
RELEASEPIN
SCREWS
HOLEINPIN
SPACER
CLEVISPIN
Attachadapterbrackets(B)tobackofdisplayusingfourM6x12mmphillipsscrews(I)withnylonshoulderwasher(H),orfour
M8x15mmphillipsscrews(J)asshownbelow.
NOTE: Hardware to attach dedicated plates to the mount are included with the dedicated plates.
B
H
I or J
5
400 mm
300 mm
200 mm
PLP
MAX VESA-600 mm
MINVESA-200mm
Attaching Adapter Brackets to Display
DISPLAY
9 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
B
B
B
B
6
600 mm
400 mm
300 mm
200 mm
PLP
SECURITY SCREW
Attachadapterbrackets(B)todisplaycarriage.Slideadapterbrackets(B)topositionbasedonholepatternasshownbelow.
Loosely fasten in place using security screw as shown in detail 1.
NOTE:Oncedisplayislocatedindesiredposition,tightensecurityscrewsusing4mmallenwrench(K)tolockinplace.
Attaching Adapter Brackets to Display Carriage
DISPLAY CARRIAGE
DISPLAY CARRIAGE
FRONT
DETAIL 1
OUTSIDEEDGEOF
ADAPTER BRACKET
DETAIL 2
Horizontal Display Position
OPTIONAL GUIDE: When positioning adapter brackets make sure outside edge
of adapter bracket is in notch on display carriage as shown in detail 2.
NOTCH
Screen and adapter brackets can slide along rail to position
screen horizontally.
10 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Use legend below to determine position of display.
NOTE: Eachknobcanbeadjustedindependentlyfornetuningadjustments.
7
Turn knob CLOCKWISE to tighten
Turn knob COUNTER-CLOCKWISE to loosen
UP
ROTATE LEFT ROTATE RIGHT
DOWN
Display Carriage Adjustment
11 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
Turn knob CLOCKWISE to tighten
Turn knob COUNTER-CLOCKWISE to loosen
UP
ROTATE LEFT
TOP
TOP
TOP
TOP
TOP
TOP
Use legend below to determine position of display.
NOTE: Eachknobcanbeadjustedindependentlyfornetuningadjustments.
8
Turn knob CLOCKWISE to tighten
Turn knob COUNTER-CLOCKWISE to loosen
DOWN
IN
OUT
TILT BACKWARD TILT RIGHT
TILT LEFT
TILT FORWARD
Adapter Bracket Adjustment
BACK BACK BACK
BACK BACK BACK
12 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
9
TILT FOWARD
TILT LEFT
DISPLAY CABLE
S
V
IDEO
WALL
MOUN
T
ASSEMBL
Y
CABLE
THROUGH
TOP
CABLE
THROUGH BOTT
OM
DISPL
AY
Display cables can be routed through top or bottom of video wall mount assembly.
NOTE:Usemeshsleeve(M)andcableties(L)forcablemanagementasshownindetail3
NOTE: Cable ties and cable management slots on video wall mount assembly can be used to secure display cables.
Cable Management
DETAIL 3
CABLEMANAGEMENT
SLOTS
M
L
13 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
10
VIDEOWALL
MOUNTASSEMBLY
DISPLAY CARRIAGE
ACCESS BRACKETS
VIDEOWALL
MOUNTASSEMBLY
DISPLAY CARRIAGE
ACCESS BRACKETS
Opendisplaycarriagebyreleasinglockingpin.Onceopenpushdownonaccessbrackettolockdisplaycarriageinplace.
NOTE: Make sure that access bracket is notch in display carriage as shown in detail 4.
LOCKINGPIN
SLOT
SLOT
Open and Close Display Carriage
Close Display Carriage
NOTCH
NOTCH
Closedisplaycarriagebypullinguponaccessbrackettounlockdisplaycarriage.Onceunlockedclosedisplaycarriage.
NOTE: Make sure that access bracket is out of notch in display carriage before closing.
DETAIL 4
14 of 14
ISSUED: 04-23-10 SHEET #: 145-9010-2 04-27-10
11
Securelockingtabusingtwosocketpinscrews(D)asshownbelow.
Lockbracket(C)andlock(notsupplied)canbeusedtosecuredisplaycarriagetovideowallmountassemblyas
shown in below.
C
C
LOCKINGTAB
D
LOCK
(NOTSUPPLIED)
VIDEOWALL
MOUNTASSEMBLY
SLOTINVIDEOWALL
MOUNTASSEMBLY
Optional
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Peerless DS-VW760 Specification

Category
Flat panel wall mounts
Type
Specification

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI