Korber Solutions LTI MOTION ServoOne CM Operating instructions

Type
Operating instructions

This manual is also suitable for

Expansion module
Compact multi-axis system ServoOne CM
ServoOne CM
Operation Manual
2
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
Overview of SO CM-E expansion modules
Expansion module Single Expansion module Dual Expansion module Dual End
SO CM-E.x0xx.0 SO CM-E.x0xx.1 SO CM-E.x0xx.2
Operation Manual Expansion Module SO CM-E
Compact multi-axis system ServoOne CM
1800.202B.0-01
Date: 02/2019
This documentation is to be kept!
The German version is the original of this document.
Multi-axis system ServoOne CM
Consisting of the ServoOne CM-P supply unit, the DC-powered ServoOne CM axis
controllers and a matching controller MotionOne CM, the compact multi-axis system
SystemOne CM offers a high degree of solutions expertise and exibility in the range
from 2 A to 210 A rated current.
With the aid of the ServoOne SO CM-E expansion module, the ServoOne CM axis
controllers BG1+2 can be combined with the ServoOne CM axis controllers BG3+4
without problems.
The addition of the ServoOne CM-C capacitance module to the ServoOne CM-P supply
unit BG3+4 makes possible usage in even more dynamic applications.
The external ServoOne CM-S switched-mode power supply is also available for the 24 V
control supply.
Reduction of the wiring and shortening of the installation times are just as easy to
achieve as resource-saving, cost-conscious operation.
Usage of the expansion module:
It is used to protect, monitor and adapt the smaller cable cross-section (DC link = lower
current carrying capacity) on the axis controllers SO CM BG1+2 to the larger cable
cross-section (DC link = higher current carrying capacity) on the axis controllers SO CM
BG3+4.
Subject to technical change without notice.
This document has been prepared based on DIN EN 82079-1. The content was
compiled with the greatest care and attention based on the latest information available to
us.
We should nevertheless point out that this document cannot always be updated
simultaneously with the on-going technical development of our products.
Information and specications may be subject to change at any time. For information on
the latest version, please visit www.lti-motion.com/socm.
3
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
Table of contents
1 General .......................................................................................5
1.1 Target group ........................................................................................................... 5
1.2 Prerequisites ...........................................................................................................5
1.3 Pictograms .............................................................................................................5
1.4 Disclaimer ...............................................................................................................5
1.5 Reference documents ............................................................................................5
1.6 Order code ............................................................................................................. 6
1.7 Rating plate ............................................................................................................6
1.8 Brief description ..................................................................................................... 7
1.9 Scope of supply...................................................................................................... 7
1.10 Disposal .................................................................................................................8
1.11 Sup po r t ..................................................................................................................8
2 Safety .........................................................................................9
2.1 O ve r vi ew ................................................................................................................ 9
2.2 Measures for your safety ........................................................................................ 9
2.3 General safety instructions and warnings ............................................................. 10
2.4 Intended use ......................................................................................................... 10
2.4.1 Repair .................................................................................................... 11
2.5 Misuse .................................................................................................................. 11
2.6 Responsibility ....................................................................................................... 11
2.7 Relevant laws, standards and directives applied .................................................. 11
2.8 Declaration of conformity ...................................................................................... 12
3 Mechanical installation .............................................................. 13
3.1 Notes for installation ............................................................................................. 13
3.1.1 Order and arrangement ......................................................................... 13
3.2 Mounting clearances ............................................................................................ 14
3.3 Cooling the devices .............................................................................................. 15
3.4 Installation of the devices for wall mounting .......................................................... 16
3.4.1 Dimensions, wall mounting model ......................................................... 16
4 Electrical installation .................................................................. 17
4.1 Before you start .................................................................................................... 17
4.2 Effective EMC installation ..................................................................................... 17
4.3 Overview of the connections ................................................................................ 18
4.4 Protective earth conductor connection................................................................. 19
4.4.1 PE connection in accordance with DIN EN 61800-5-1 .......................... 19
4.4.2 Connection principle ............................................................................. 19
4.5 Electrical isolation concept ................................................................................... 20
4.6 Connection of the supply voltages ....................................................................... 21
4.6.1 24 V control supply, "Single + Dual" model ........................................... 21
4.6.2 24 V control supply, "Dual End" model .................................................. 22
4.6.3 Power supply "Single + Dual" ................................................................ 22
4.6.4 Power supply, "Dual End" model ........................................................... 23
4.6.5 Overview of busbars in the group..........................................................23
4.7 Specication, fuses F+, F- .................................................................................... 24
4.7.1 Note about changing the fuses ............................................................. 24
4.8 "Dual" and "Dual End" model................................................................................ 25
4
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
4.9 Control connections (front panel) .......................................................................... 25
4.9.1 Layout, control connections .................................................................. 26
4.9.2 Specication, relay contact X5/ REL Output .......................................... 26
4.9.3 Specication, connection X6/ State.......................................................26
4.10 Cross-communication ..........................................................................................27
4.10.1 Specication .......................................................................................... 27
4.10.2 Connection example ............................................................................. 27
4.11 Expansion modules with "internal" quick shutdown in two rows .......................... 28
5 Diagnostics .............................................................................. 29
5.1 Status indication LEDs .........................................................................................29
A Appendix .................................................................................. 31
A.1 Technical data, SO CM-E ..................................................................................... 31
A.2 Ambient conditions ............................................................................................... 31
A.4 Certications.........................................................................................................33
A.4.1 CE certication ...................................................................................... 33
A.4.2 UL certication ...................................................................................... 33
A.5 Connection system .............................................................................................. 33
A.5.1 Connection cables for communication ..................................................33
A.5.2 Pre-assembled DC link cable, expansion modules ...............................33
Glossary ........................................................................................... 35
5
General
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
1 General
The product DVD from LTI Motion GmbH contains the complete documentation for all
product series. The documentation for a product series includes the operation manual
(hardware description), device help (software description) as well as further user manuals
(e.g. eld bus description) and specications. The documents are available in PDF
format.
1.1 Target group
Dear user,
The documentation forms part of the device and contains important information on
operation and service. It is aimed at all persons who undertake mounting, installation,
commissioning and servicing work on the product.
1.2 Prerequisites
Prerequisites for the usage of devices from LTI Motion GmbH:
yThe documentation on the devices is to be stored so it is legible, accessible at
all times and for the entire life of the product.
yThe user must read and understand the documentation on the device.
yQualication: to prevent injury or damage, personnel may only work on the
device if they have electrical engineering qualications.
yKnowledge required:
National health and safety regulations (e.g. DGUV V3 in Germany)
Mounting, installation, commissioning and operation of the device
Work in other areas, for example transport, storage and disposal is only allowed to be
undertaken by trained personnel.
1.3 Pictograms
The pictograms used in this operation manual signify the following for the user:
NOTE:
Useful information for the user.
Reference to other documents.
You will nd the "safety instructions and warnings" used in this operation manual in
chapter 2 Safety.
1.4 Disclaimer
Following the documentation on the devices from LTI Motion GmbH is a prerequisite:
yFor safe operation.
yTo achieve stated performance features and product characteristics.
LTI Motion GmbH does not accept any liability for injuries, damage or nancial losses
that result from the failure to follow the documentation.
1.5 Reference documents
NOTE:
You will nd all reference documents for this device on our web site at
www.lti-motion.com/socm
6
General
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
1.6 Order code
Article ID SO CM - E . x 0 x x . 0 x 0 0 . 0
ServoOne
Compact multi-axis system
Model E: Expansion module
Reserve x:
Cooling 0: Wall mounting (with heat sink)
1: Cold plate (without heat sink)
Reserved
Version
0: Single
1: Dual
2: Dual end*
Reserved x:
Extras 0: None
1: Assemblies coated
Model 0: LTI Motion
Version index
* In preparation
1.7 Rating plate
On the rating plate of the ServoOne CM-E expansion module you will nd the serial
number, from which you can identify the date of manufacture based on the following key.
Mac Adr.:
SW:
FS SW1:
SN:
SN:
FS SW2:
LTI Motion GmbH
35633 Lahnau
Germany
www.lti-motion.com
Multiple rated equipment. See instruction manual
In:
Out:
Year:
T1
T
SO CM-E.0000.1000.0
JJWWSXXXX
565V DC - 678V DC
2018
78A DC - 64A DC
565V DC - 678V DC
2 x (39A DC - 33A DC)
JJWWSXXXX
MACADR
V 0.1
SO CM-E.0000.1000.0
Serial no. key:
JJ (YY) = Year of production
WW = Week of production
S = Production site
xxxx = Sequential no. (per calendar week)
Figure 1.1 Rating plate (e.g. ServoOne CM-E expansion module Dual)
7
General
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
1.9 Scope of supply
The scope of supply includes:
yServoOne CM-E expansion module
yData cable set for cross-communication
yBusbar elements for control supply (24 V DC)
and DC link (DC Link +/-)
yProduct DVD with booklet
Additional scope of supply for the model SO CM-E.x0xx.1 (Dual).
yPre-assembled DC link cable (DC Link +/-)
Difference in the scope of supply for the model SO CM-E.x0xx.2 (Dual End)
yBusbar elements for DC link not included (DC Link +/-)
T
T1
Figure 1.2 Position of rating plate (T) Figure 1.3 Position of second rating plate (T1)
A second rating plate (T1) with only the most important information is on the top of
the busbar cover. In this way the rating plate data can also be seen if the devices are
installed in a row.
1.8 Brief description
NOTE:
Only the ServoOne CM-E expansion modules are described in this operation
manual. You will nd information on other components in the related
documentation.
Allocation:
Type Designation Input current Output current
SO CM-E.x0xx.0 Single 39 to 33 A DC 39 to 33 A DC
SO CM-E.x0xx.1 Dual 78 to 64 A DC 2x 39 to 2 x 32 A DC
SO CM-E.x0xx.2 Dual End 39 to 33 A DC 39 to 33 A DC
8
General
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
1.10 Disposal
Follow the current national regulations!
Depending on their characteristics, dispose of individual parts as:
a. Electrical waste
b. Plastic waste
c. Metal scrap
Or engage a certied disposal organisation with scrapping.
1.11 Support
Address: LTI Motion GmbH
Gewerbestrasse 5-9
35633 Lahnau
If you have any questions about the project planning for your machine or the
commissioning of your device, our Helpline will provide you with quick, specic
assistance.
The Helpline is available by e-mail or telephone:
Service hours: Mo.-Fr.: 8a.m. - 5p.m. (CET)
Telephone: +496441966-180
Internet: www.lti-motion.com
NOTE:
You will nd detailed information about our services on our web site
www.lti-motion.com Service
9
Safety
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
2 Safety
2.1 Overview
Our devices are state-of-the-art and comply with recognised safety regulations,
nevertheless hazards can arise. In this chapter:
yWe provide information on residual risks and hazards that can emanate from
our devices on usage as intended.
yWe warn about the foreseeable misuse of our devices.
yWe refer to the necessary care and measures to be taken to prevent risks.
2.2 Measures for your safety
NOTE:
Your device is only allowed to be installed and placed in operation taking into
account the documentation for the related device family!
Our devices are quick and safe to operate. For your own safety and for the safe function
of your device, please be sure to observe the following points:
1. Follow safety instructions for the devices:
Follow all safety instructions and warnings in the entire documentation related to the device series.
2. Electric drives are dangerous:
• Due to electrical voltages up to 480V AC and up to 800V DC
• Even 3min. after switching off the mains supply, dangerously high voltages of ≥50V may
still be present (capacitor charge). So check that electrical power is not present! See also the
warning label on the front panel on the device.
• Rotating parts
• Automatically starting drives.
• Hot components and surfaces
3. Protection against magnetic and/or electromagnetic elds during
installation and operation.
Persons tted with heart pacemakers, metallic implants or hearing aids etc. must not be allowed
access to the following areas:
• Areas in the immediate vicinity of electrical equipment!
• Areas where electronics components and drive controllers are installed,
repaired and operated!
• Areas where motors are installed, repaired and operated!
Motors with permanent magnets pose particular hazards.
4. During installation observe the following:
• Comply with connection conditions and technical data as per the documentation and the rating
plate!
• Comply with standards and directives on electrical installation, such as cable cross-section,
shielding, etc.!
• Do not touch electronic components or contacts!
Electrostatic discharge can harm people and destroy components!
• Take protection measures and use protective devices as per the applicable regulations
(e.g. EN 60204 or EN 61800-5-1)!
• Take "device earthing" protection measure!
5. Ambient conditions
• Follow the instructions on the transport, storage and correct operation of the devices stated in
the operation manual in "A Appendix".
10
Safety
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
2.3 General safety instructions and warnings
DANGER! Risk of injury due to electrical power!
• Carelessness will result in serious injuries or death.
Follow safety instructions and warnings in this document and on the device.
WARNING! Risk of injury due to electrical power!
• Carelessness may result in serious injuries or death.
Follow safety instructions and warnings in this document and on the device.
CAUTION! Risk of injury or damage to the device due to incorrect operation!
• Carelessness may result in minor injuries or damage.
Follow safety instructions and warnings in this document and on the device.
WARNING! Risk of injury due to hot surfaces and components!
• Carelessness may result in serious burns.
Electronic components may become hot during operation!
Follow safety instructions and warnings in this document and on the device!
Caution! Damage due to electrostatic discharge!
• Electrostatic discharge can destroy components.
Do not touch electronic components or contacts!
Follow safety instructions and warnings in this document and on the device!
DANGER! Risk of injury due to rotating parts on the motor!
• Carelessness will result in serious injuries or death.
Follow safety instructions and warnings in this document.
Pay attention to special safety instructions and warnings that are given here in the document before a
specic action and that warn the user about a specic hazard!
NOTE:
The pictograms may also be used on their own with the signal word, e.g.
in the connection diagrams, however they have the same function as in the
complete warning.
DANGER WARNING CAUTION
2.4 Intended use
Our devices are components intended for stationary electrical systems and machines in
the industrial and commercial sector.
The ServoOne CM-E expansion modules conform to the
Low Voltage Directive 2014/35/EU
Tested and certied in accordance with applicable standards (see declaration of conformity in
chap. 2.8).
When installed in machines it is prohibited to start-up intended operation until it has
been ascertained that the completed machine fully complies with the provisions of the
Machinery Directive (2006/42/EC); compliance with EN 60204 is mandatory.
Starting up intended operation is only permitted on compliance with the EMC Directive
2014/30/EU.
The devices meet the requirements of the harmonised product standard EN 61800-5-1.
You will nd information on the installation of your device in chapter "3 Mechanical
installation".
11
Safety
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
The emergency stop function (as per EN 60204) shuts down the supply of power to a
machine, which results in the drives coasting down in an uncontrolled manner. To avert
hazards, check whether it is appropriate:
To keep individual drives in operation
To initiate specic safety procedures
To incorporate an emergency stop function (emergency stop function: movement stop
by "switching off the electrical supply" or STO Safe Torque Off)
2.7 Relevant laws, standards and directives
applied
For information on the laws, standards and directives applied by LTIMotionGmbH,
please refer to the declaration of conformity.
NOTE:
Depending on the specic application for the devices, other laws, standards
and directives with provisions on "safety" may apply. If necessary, contact the
machine or system manufacturer.
2.4.1 Repair
Only have repairs undertaken by authorised repair shops. Unauthorised repairs could
lead to death, injury or damage (see previous sections). The warranty provided by
LTIMotion will be rendered void.
2.5 Misuse
Our devices are:
yNot intended for installation in vehicles. Deployment of the device in mobile
equipment is classed as non-standard ambient conditions and is permissible
only by special agreement.
yNot intended for installation in environments with harmful oils, acids, gases,
vapours, dusts, radiation etc.
yNot approved for usage in special applications (e.g. in potentially explosive
atmospheres or areas in which there is a risk of re).
yNot approved for usage outside a switch cabinet
2.6 Responsibility
Electronic devices are not fail-safe. The installer and/or operator of a complete machine
or system is responsible:
yFor ensuring the drive is rendered safe if the device fails
yFor ensuring the safety of personnel and machinery
yFor ensuring the complete machine is in correct working order
yFor the risk assessment on the complete machine or system according to
DIN EN 12100:2011
yPay attention to the topic of “Electrical equipment of machines” in
EN 60204-1:2006 “Safety of machinery”. The safety requirements on electrical
machines dened there are intended to protect personnel and machinery or
systems.
12
Safety
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
2.8 Declaration of conformity
13
Mechanical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
3 Mechanical installation
3.1 Notes for installation
During the installation work it is imperative you avoid ...
yDrill chippings, screws or other foreign bodies falling into the device
yMoisture entering the device
Switch cabinet
yThe device is designed only for installation in a stationary switch cabinet. The
switch cabinet must as a minimum provide IP4X protection. According to
ENISO13849-2 the switch cabinet must have IP54 protection or higher when
using the safety functions (STO and SBC in the axis controller).
Environment
yThe ServoOne CM-E module must not be installed in areas where it would be
permanently exposed to vibration. You will nd more information in the appen-
dix.
Soiling
yMaximum pollution degree 2 in accordance with EN60664-1. Further informa-
tion on ambient conditions can be found in the appendix.
Effective EMC installation
yTo obtain the best result for effective EMC installation you should use a conduc-
tive, well-earthed, chromated or galvanised backing plate.
If backing plates are varnished, remove the coating from the contact area! The devices
themselves have a chromated zinc frame.
NOTE:
On installing the CM-E module in the axis group, it is imperative the operation
manuals for the other devices (supply unit, controller, etc.) are also followed.
3.1.1 Order and arrangement
The following basic guidelines apply to the arrangement and installation of the CM-E
module:
Butt mounting and alignment
yThe devices can be mounted directly beside each other without any spacing.
They are fastened to the backing plate using two screw joints.
yAll devices in the axis group - supply unit (SO CM-P), axis controller (SO CM)
and the controller (MO CM) - are connected together using the 24 V busbars.
Given the same cooling concept, these connections can be made without addi-
tional compensation measures in relation to the device depth.
yDC link busbars are available for the power supply. The ServoOne CM axis
controllers BG3+4 are to be connected on the left side of the ServoOne CM-E
expansion module, the ServoOne CM axis controllers BG1+2 are to be con-
nected on the right side.
yThe devices must be mounted in the stipulated order one against the other see
Bild 3.1. A different order is not allowed, as otherwise there will be problems
with the busbars and the thermal interaction between the devices.
CAUTION! Damage to the device due to incorrect installation conditions!
The device may suffer irreparable damage if the conditions are not met.
• The direct connection of the DC link connections between SO CM BG3/4 and SO CM BG1/2
without an SO CM-E module is not allowed. Devices may be irreparably damaged if this
instruction is not followed.
NOTE:
You will nd rules for the arrangement of the various components of the
ServoOne CM system in the "Manual SO CM Multi-Axis System (ID no.:
1800.005B.X)"
14
Mechanical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
126
7
4
35
1.) MotionOne CM controller
2.) ServoOne CM-P supply unit BG3
3.) ServoOne CM-C capacitance module (optional)
4.) ServoOne CM axis controller BG3
5.) ServoOne CM axis controller BG4
6.) ServoOne CM-E expansion module
7.) Poss. ServoOne CM axis controller BG1+2
Figure 3.1 Butt mounting sequence
3.2 Mounting clearances
CAUTION! Damage to the device due to incorrect installation conditions!
The device may suffer irreparable damage if the conditions are not met.
• The minimum clearances stated in the gure below apply to the entire ServoOne CM
multi-axis system. The distances are primarily dened by the ServoOne CM-P BG3+4 and
ServoOne CM BG3+4 devices.
• The clearance above the devices is important to prevent the build-up of heat. The clearance
underneath and at the front is necessary to permit correct cable laying.
150
200*)
SO CM-P-BG3 SO CM-BG3
300
Figure 3.2 Mounting clearances ServoOne CM
15
Mechanical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
150
200 *)
300
SOCLP-BG4 SOCL-BG4
*) The bending radius of the connection cables must also be taken into account:
Figure 3.2 Mounting clearances ServoOne CM
NOTE:
Depending on the connection cables used (mains cable/motor cable), the
mounting clearances may increase signicantly due to the bending radii nec-
essary. For details see Operation Manual ServoOne CM BG3+4 and ServoOne
CM-P BG3+4.
3.3 Cooling the devices
Cooling air must be able to ow through the device (interior and heat sink) without re-
striction. If a thermal cut-out occurs, the cooling conditions must be improved.
Figure 3.3 Cooling air ows unhindered through the
device
16
Mechanical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
3.4 Installation of the devices for wall mounting
Step Action Comment
1.
Arrange the devices on the backing plate as per Bild 3.1.
Please also provide enough space to the left of the supply
unit for the MotionOne CM controller.
Align all devices in a multi-axis group in a line along the
top edge of the devices.
This action is necessary to be able to
couple the DC link using the busbars.
2.
Mark out the position of the tapped holes on the backing
plate.
Drill holes in the backing plate and cut a thread for each
xing screw in the backing plate.
Pay attention to the bending radius of the
connection cables!
For hole spacing and dimensional drawings
see Table2.1, Bild 3.4
3. Mount the CM-E module vertically on the backing plate. The contact surface must be bare metal
and conductive.
You will nd the next steps for the electrical installation in chapter 4.
3.4.1 Dimensions, wall mounting model
ServoOne CM-E BG1 (Single/Dual/Dual End)
Weight approx. 2.8 kg
H (height) 310
B (width) 54.5
T (depth) 241
A 27.5
C 299
C1 6
Side clearance Direct butt mounting
D Ø 5
All dimensions in mm
Table 3.1 Dimensions and mounting clearances for wall mounting
241,00
54,50
310
5
27,25
6 299
Figure 3.4 Dimensional drawing, SO CM-E module (for dimensions see Tabelle 3.1)
4 Electrical installation
4.1 Before you start
During the installation work it is imperative you avoid ...
yScrews, cable residue or other foreign bodies falling into the device
yMoisture entering the device
DANGER! Risk of injury due to electrical power!
Carelessness will result in serious injuries or death.
Never make or disconnect electrical connections while they are electrically live! Always
disconnect the power before working on the supply unit. Even 3min. after switching off the mains
supply, dangerously high voltages of ≥50V may still be present (capacitor charge). Therefore
always check electrical power is not present!
Only once the DC link voltage has dropped to a residual voltage of less than 50V (to be
measured at the DC link busbars) is it allowed to work on the device.
Pay attention to warning sign on the device (see front of device).
NOTE:
On installing the expansion module in a ServoOne CM multi-axis system, it is
imperative the operation manuals for the other devices (axis controllers, supply
unit) are also followed.
4.2 Effective EMC installation
Compliance with the EMC product standard
Commissioning i.e. start-up of intended operation is only permitted on strict compliance
with the EMC Directive (2014/30/EU). The installer/operator of a machine and/or system
must provide proof of compliance with the protection targets stipulated in the standard.
The essential EMC measures are already implemented in the design of the devices in
the form of optimised housing shielding, printed circuit board layout, lter measures and
selection of suitable connectors with shield plate. In addition to the internal measures,
the following installation measures are to be noted:
17
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
Routing of cables
yIf possible, signal cables should only enter from one side into the switch
cabinet.
yIt is recommended to twist lines of the same electrical circuit.
yAvoid unnecessary cable lengths and "loops of spare cable".
Shielding measures
yA shielded connection cable is not necessary for the connection of the
expansion module.
Cable type
yIf stipulated, please use shielded cables with double copper braiding with 60%
to 70% coverage. To connect LTi servomotors we recommend the usage of
pre-assembled motor and encoder cables from LTI Motion, as all EMC tests
have been undertaken successfully with these cables.
NOTE:
If connection cables from other suppliers are used, these cables must as a
minimum be equivalent. However, an assurance of stable, reliable operation
with such cables cannot be given by LTI Motion.
Earthing measures
yThe devices are to be fastened to a conductive, earthed backing plate. Earthing
measures to EN61800-5-1 are described in Chapter 4.4.
External components
yPlace larger loads near the supply.
yContactors, relays, solenoid valves (switched inductances) must be wired with
suppressors. The wiring must be directly connected to the respective coil.
yAny switched inductance should be at least 0.2m away from the process-
controlled assemblies.
If you require further detailed information on installation, you should consult the
LTIMotion Helpline, see Chapter 1.11.
18
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
Abbreviation Designation Details
X1/ DC Link DC link supply via terminals
Only on model SO CM-E.x0xx.1/(2) add.
connections for second expansion
module
X2/ 24 V DC 24 V control supply via terminal See Chapter 4.8
DC Link -/+ DC link supply busbars See Chapter 4.6.3
24 V DC Control supply busbars See Chapter 4.6.1
LEDs Error / Voltage See Chapter 5.1
X3/ XC IN Cross-communication input
See Chapter 4.10
X4/ XC OUT Cross-communication output
X5/ REL Output Relay contact (RO02) programmable See Chapter 4.9.2
X6/ State Digital inputs (programmable)
Test pulse outputs
See Chapter 4.9.3
X7/ ES "Internal" quick shutdown See Chapter 4.9.2
F+ = right
F- = left Fuses for DC link cable protection See Chapter 4.7
A Service cover
Connection for protective earth conductor/
earthing
See Chapter 4.4
Table 4.2 Key to the SO CM-E module layout
4.3 Overview of the connections
In the following you will nd the layout for the ServoOne CM-E expansion module with
the corresponding positions of the connectors and terminals.
24 V DC
DC Link +/-
X1/ DC Link
X2/ 24V DC
X3
X4
X6/State
X7/ES
F-
F+
A
X5/REL
LEDs
Figure 4.1 Layout, ServoOne CM-E expansion module
19
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
4.4.2 Connection principle
5
10
1
344
8
6 77
2
L ≤ 1,5 m
5
PE
Netz/Line
9
1. Mains lter
2. Mains choke
3. MotionOne CM controller
4. ServoOne CM-P supply unit BG3
5. ServoOne CM axis controller BG3/4
6. ServoOne CM-E expansion module
7. ServoOne CM axis controller BG1/2
8. Star topology earthing
9. Earthing for SO CM-E ≥ 16 mm2 (as per EN 61800-5-1)
10. Earthing in series (only SO CM BG1+2) optionally
PE strap (article no.: 1400.807.0) can be used
Figure 4.2 Example: Connection of the SO CM BG3/4 to the expansion module and SO CM
BG1/2
4.4 Protective earth conductor connection
Step Action Comment
1.
Connect the PE connections on the expansion module, the supply
unit, the axis controllers and the controller etc. to the PE rail (main
earth) in a star topology, see Figure 4.2.
Each device in the axis group
must be earthed!
2.
Connect the protective earth conductor connections on all other
components, such as mains lter*), mains choke*) etc. in a star
topology to the PE rail (main earth) in the switch cabinet.
*) Components are only
required for the ServoOne
CM-P supply unit.
4.4.1 PE connection in accordance with DIN EN 61800-5-1
The leakage current is > 3.5 mA. This situation results in the following minimum
requirements for the protective earth conductor cross-section as a function of the phase
conductor cross-section, as per EN61800-5-1.
Cross-section of the phase conductors Minimum cross-section
of the corresponding protective earth conductor
Q ≤ 16 mm2 Q however at least 10 mm2 (Cu)
16 < Q ≤ 35 mm2 16 mm2 (Cu)
Q > 35 mm2 Q/2
Table 4.3 Protective earth conductor cross-section
CAUTION! Risk of injury due to incorrect wiring!
Carelessness may result in injuries.
The protective earth conductor connection is a safety feature. Therefore, make sure that all
connections have good contact and are sufciently secure that they cannot come loose.
NOTE:
Always comply with local and national regulations and conditions.
20
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
X6
X11
X8
L1 L3
L2
11
19
12
24 V
GND
X5.1
X3 X3 X4
X5.2
DC Link -
DC Link+
GND
+24 V
X7
X8
X9
X10
X3
X4
BR X1
X1
X2
2
5
z
Netz/Line
PE
ZK
BR
X11
BR
15
7
DC Link+/-
GND
+24 V
F3
X3
X4
X6
X11
8
X5.1
X3 X4
X5.2
DC Link -
DC Link+
GND
+24 V
X7
X8
X9
X10
W
U
V
X12
Motor
3~
32
2
W
U
V
X14
Motor
3~
32
2
W
U
V
X13
Motor
3~
32
2
BRK
Motor
PELV
BI
ZK
PELV
PELV
PELV
PELV PELV
PELVPELV
L1 L2 L3 PE
L3
L2
L1
L3.1
L2.1
L1.1
1
14
13
6
L1
N
3
25
X5
X5
Motor1
3~
32
2 2
TEMP
BRAKE
5
L3
L2
L1
L3.1
L2.1
L1.1
WUV
Motor2
3~
32
WUV
TEMP
BRAKE
MOTOR 2
MOTOR 1
PELV
BI
ZK
PELV
PELV
PELV
PELV
PELV
VI
PELV PELV
PELVPELV
ZK
X6
X6
TP
PELV
PELV
PELV
BI
Netz
X6
X6
PF
EXP
PELV
PELV
BI
VI
X6
X6
DI
PELV
PELV
X7
ES
PELV
PELV
PELV
X2
24 V
X1
DC Link
PELV ZK
(1) Mains fuse for DC link supply (11) Supply unit SO CM-P BG3/4
(2) 24 V DC power supply unit (external) (12) Axis controller SO CM BG3/4
(3) Mains contactor (optional) (13) Switch cabinet
(5) Mains lter (accessory) (14) Panel
(6) Mains choke (accessory) (15) Braking resistor with temp. monitoring (external)
(7) SO CM-E expansion module (19) Star topology protective earth conductor via PE rail
(8) Axis controller SO CM BG1/2
Figure 4.3 Electrical isolation concept with key
4.5 Electrical isolation concept
The control terminals are designed as protective extra low voltage
(PELV) circuits and must only be operated with such PELV voltages,
as per the relevant specication. This aspect provides reliable
protection against electric shock.
The connections DC Link +/-, Motor1 U/V/W, Motor2 U/V/W are at
mains potential (low voltage).
The overview opposite shows the potential references for the
individual connections in detail. This concept also delivers better
operational safety and reliability of the axis controllers.
Connections
SO CM-E (7) Description Potential Abbre-
viation
Busbars
24V DC
Control section
supply voltage
Protective extra low
voltage circuit 3) PELV
Busbars DC
Link
DC link
supply voltage Low voltage 1) ZK
X1/ DC Link
(terminal)
DC link supply to the 2nd
SO CM-E via terminal and
pre-assembled cable 5)
Low voltage 1) ZK
X2/ 24 V DC
(terminal)
24 V supply to the
2nd SO CM-E
Protective extra low
voltage circuit 3) PELV
X3 / X4 Cross-communication Protective extra low
voltage circuit 3) PELV
X5 / REL Relay contact Reinforced insulation VI
X6 / State Dig. outputs (TP, REL) Protective extra low
voltage circuit 3) PELV
X7 / ES "Internal" quick shutdown PELV
X11 /
Safe - DI Safe digital inputs Protective extra low
voltage circuit 3) PELV
1) Low voltage = AC: U ≤ 1000 V, 2) Single isolation from the low-voltage network and PELV network
3) PELV (Protective Extra Low Voltage)
AC: U ≤ 50 V One connection for the extra low voltage is earthed.
4) Safe isolation from the low-voltage network and PELV network, 5) See .......
Table 4.4 Key to the overview "Electrical isolation concept"
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Korber Solutions LTI MOTION ServoOne CM Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI