Triple Clear TC-POU-10-KIT User manual

Type
User manual
REPLACING THE FILTER
1. Close inlet isolation valve and open cold water faucet to relieve
pressure. Once pressure is relieved close cold water faucet.
2. Close outlet isolation valve.
3. Remove inlet and outlet connections on Triple Clear Force
Field Filter by pushing in collet and pulling tubing straight out of
connections.
4. Remove Triple Clear Force Field Filter from mounting bracket and
discard appropriately.
5. Install new Triple Clear Force Field Filter into mounting bracket.
6. Insert inlet and outlet tubing in the appropriate filter connections.
Tubing should insert 3/4 to 7/8” into connections.
7. Open inlet isolation valve slowly, inspecting tubing and
connections for any leaks.
8. Open outlet isolation valve slowly, inspecting tubing and
connections for any leaks.
NOTE: IN THE EVENT OF LEAKAGE, TURN OFF WATER SUPPLY
AND TAKE APPROPRIATE ACTION TO RECTIFY.
9. Open faucet to purge any trapped air from the system, confirm
proper operation, and allow filter to flush prior to use. A minimum of
XXX gallons is recommended to flush the filter.
For more information or questions, please contact your authorized
installer.
Installation and
Operating Instructions
Triple Clear Force Field Filter
TM
TC-POU-FFC10
and
TC-POU-FFC5
SAFETY INFORMATION
Read all safety information and instructions
prior to installation of the Triple Clear Force Field Filter.
• The Triple Clear Force Field Filter is intended for use in filtering potable water in
homes. The system is typically installed at the point of use, and must be installed
according to these instructions.
• This filter is intended to be used in a vertical arrangement and should be in a
location that will prevent it from being struck by other items.
• When choosing a position to mount the filter bracket, do not install near electric
wiring, piping and/or existing water lines which may be in the path of a drilling tool
• Install in accordance with existing state or local plumbing codes. Ensure all tubing
and fittings are secure and free of leaks.
• Do not use with water that is not potable.
• Install on cold water lines only.
• Do not install in direct sunlight.
• The filter must be protected from freezing. Structural integrity may be compromised
should filter be allowed to freeze.
• The Triple Clear Force Field Filter is designed to be used at a maximum pressure of
80 psi. If water pressure exceeds 80 psi a pressure limiting device must be installed.
• Do not install where water hammer conditions are present. If water hammer
conditions do exist, a water hammer arrester must be installed.
• Do not install on hot water supply lines. The maximum operating water temperature
of this filter system is 80°F.
• The Triple Clear Force Field Filter is designed to be replaced every XXX months.
PARTS AND MATERIALS: (included)
Triple Clear Force Field Filter (A)
Mounting bracket (B)
2 – 3/8” opaque tubing (C)
2 – 3/8” isolation valves (D)
4 – mounting screws (E)
4 – mounting screw anchors (F)
TOOLS REQUIRED:
(Not included)
#2 Phillips head screwdriver
Drill
Pencil
Level
BEFORE YOU BEGIN:
• Remove items from the immediate area of the installation.
• Please note water spillage may occur during installation and appropriate measures
should be taken
• For optimum performance the filter must be installed with the inlet and outlet ports
as labeled. Make sure not to reverse connections.
• The Triple Clear Force Field Filter has been designed for a maximum flow rate of
XXX gpm.
• Failure to follow instructions may void any expressed or implied warranties.
7. Turn on the cold
water supply slowly,
inspecting tubing and
connections for any
leaks.
8. Open inlet isolation
valve slowly,
inspecting tubing and
connections for any
leaks.
9. Open outlet
isolation valve slowly,
inspecting tubing and
connections for any
leaks.
NOTE: IN THE
EVENT OF LEAKAGE,
TURN OFF WATER
SUPPLY AND TAKE
APPROPRIATE ACTION
TO RECTIFY.
10. Open faucet to
purge any trapped
air from the system,
confirm proper
operation, and allow
filter to flush prior
to use. A minimum
of XXX gallons is
recommended to flush
the filter.
5. Insert appropriate opaque
tubing into the inlet side of the
Triple Clear Force Field Filter.
Tubing should insert 3/4 to 7/8”
into the inlet side.
6. Insert other opaque
tubing into the outlet
side of the Triple Clear
Force Field Filter. Tubing
should insert 3/4 to 7/8”
into the outlet side.
3. Fasten the bracket to the wall using the four mounting screws
included and the anchors as necessary.
4. Verify the mounting bracket is secure.
INSTALLING THE MOUNTING BRACKET:
1. Select a location for the mounting bracket. For ease of filter
replacement select a location that offers easy access.
2. Using the level place the mounting bracket level against the
wall and mark the four screw holes.
INSTALLING THE FILTER:
1. (a)Turn off
the cold water
supply, (b)open
cold water
faucet and
(c)cut into
existing 3/8”
supply lines.
Once supply line
has been cut,
(d)close cold
water faucet.
2. Install
isolation valve
on each side of
the cut supply
line by fully
inserting supply
line tubing into
socket of the
isolation valve.
Tubing should
insert 3/4 to 7/8”
into isolation
valve socket.
NOTE: VALVES SHOULD BE IN THE CLOSED
POSITION DURING INSTALLATION
3. Insert
one piece of
the opaque
supply tubing
into the other
side of each
isolation
valve. Tubing
should insert
3/4 to 7/8”
into isolation
valve socket.
4. Install the Triple Clear Force
Field Filter into the mounting
bracket, ensuring inlet and outlet
are appropriately located.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Triple Clear TC-POU-10-KIT User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI