Instruction Manual
IM-106-880 Original Issue
February 2005
1-11
OCX 8800
Table 1-1. Product Matrix - General Purpose OCX 8800
OCX88A O
2
/Combustibles Transmitter
Code Probe Length and Material
00 No Probe or Exhaust Tube
11 18 in. (457 mm) 316 SST up to 1300°F (704°C)
21 18 in. (457 mm) Inconel 600 up to 2600°F (1427°C)
31 18 in. (457 mm) Ceramic up to 2600°F (1427°C)
12 3 ft (0.91 m) 316 SST up to 1300°F (704°C)
22 3 ft (0.91 m) Inconel 600 up to 1832°F (1000°C)
32 3 ft (0.91 m) Ceramic up to 2600°F (1427°C)
13 6 ft (1.83 m) 316 SST up to 1300°F (704°C)
23 6 ft (1.83 m) Inconel 600 up to 1832°F (1000°C)
14 9 ft (2.7 m) 316 SST up to 1300°F (704°C)
24 9 ft (2.7 m) Inconel 600 up to 1832°F (1000°C)
Code Probe Mounting Assembly
10 (ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes
20 (DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes
Code Mounting Hardware - Stack Side
0 No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)
1 New Installation - Square weld plate with studs
2 Model 218/240 Mounting Plate (with Model 218/240 Shield Removed)
3 Existing Model 218/240 Support Shield
4 Special Mounting
(1)
5 Model 132 Adapter Plate
Code Mounting Hardware - Probe Side
0 No Adapter Plate
1 Probe Only (ANSI)
2 Probe Only (DIN)
Code Electronics Housing - Communications
H1 HART Communications
H2 HART Communications with Local Operator Interface
H3 HART Communications with Calibration Solenoids
H4 HART Communications with Local Operator Interface and Calibration Solenoids
Code Electronics Mounting
01 Integral to Sensor Housing
02 Remote Electronics and no cable
03 Remote Electronics and 20 ft (6 m) cable
04 Remote Electronics and 40 ft (12 m) cable
05 Remote Electronics and 60 ft (18 m) cable
06 Remote Electronics and 80 ft (24 m) cable
07 Remote Electronics and 100 ft (30 m) cable
08 Remote Electronics and 150 ft (46 m) cable
Code Accessories
00 None
01 Flow meters & Ref.
Air
Set
02 In-Situ Filter (Stainless Steel only)
03 In-Situ Filter (SST), Flow meters & Ref.
Air
Set
11 Flow meters, and Ref.
Air Set
with Blowback
12 In-Situ Filter (SST) with Blowback
13 In-Situ Filter (SST), Flow meters & Ref.
Air
Set with Blowback
OCX88A 11 10 1 1 H3 06 02 Example
NOTE:
(1) Provide details of the existing mounting plate as follows:
Plate with studs Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate.
Plate without studs Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories.