CAME PXC2 Installation guide

Type
Installation guide
PCX2-32 - PXC2-64 - PXC2-212
PXC2-212
FA01869-EN
INSTALLER MANUAL
E
n
g
l
i
s
h
Control unit
Burglar proofi ng
Page
2 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
CONTENTS
SYMBOLS AND GLOSSARY . . . . . . . . . . . . . . . . . . PAG. 3
USAGE CONDITIONS . . . . . . . . . . . . . . . . . . . . . . PAG. 3
DESCRIPTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . 3
WARRANTY AND LIMITS OF LIABILITY . . . . . . . . . . . . . . . . . . 3
IMPORTANT FOR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . 3
SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . . PAG. 4
SYSTEM CABLING. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL UNIT INSTALLATION . . . . . . . . . . . . . . . . PAG. 5
CONTROL UNIT PXC2 TECHNICAL CHARACTERISTICS . . . . . . . . . . 5
RS-485 BUS CABLING. . . . . . . . . . . . . . . . . . . . . . . . . . 6
TRADITIONAL CABLING (input - output) . . . . . . . . . . . . . . . . . . . . . 6
BRANCHED-OUT CABLING. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
DOUBLE-BRANCH CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CABLING WITH BUS AMPLIFIER . . . . . . . . . . . . . . . . . . . . . . . . . 8
APPLICATION NOTES ON BUS RS-485 CABLING . . . . . . . . . . . . . . . . . 9
CHOOSING THE CABLE SECTION FOR THE RS-485 BUS . . . . . . . . . . . . . 9
INPUTS CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
MAIN CONTROL UNIT COMPONENTS . . . . . . . . . . . . . . . . . .12
LIST OF ELECTRICAL AND MECHANICAL CHARACTERISTICS. . . . . . .12
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . .13
WALL-MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
230 VAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SD TYPE (BATTERIES) CAN BE USED, SPECIFIC TO THE OUTPUT TERMI-
NALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
TAMPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
OUTPUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Relay 1 - Relay 2- Relay 3 alarm relay outputs . . . . . . . . . . . . . . . . 17
KEYPADS - PXKTB02/PXKTN02 . . . . . . . . . . . . . . . . PAG. 18
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ADDRESSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
KEYPAD DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
DISPLAY ICONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SYSTEM STATUS INDICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 19
SYSTEM STATUS ALWAYS DISPLAYED . . . . . . . . . . . . . . . . . . . . . 19
ALPHANUMERIC KEYPAD . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
KEYPAD MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PXITU01 KEY READER AND PXTAG01 KEY PXTAG01/PCT/TST01 KEYS
PAG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
SYSTEM STATUS DISPLAYING . . . . . . . . . . . . . . . . . . . . . . . . . 21
EXPANSION MODULES . . . . . . . . . . . . . . . . . . . . . PAG. 22
PX4IOR (EXPANSION MODULE WITH 4 CONNECTION POINTS). . . . . .22
TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
board description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
ADDRESSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PXWRX01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
ADDRESSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . PAG. 24
PXONV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PXMC3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DESCRIPTION OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LED STATUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Fitting the SIM-CARD (not supplied) . . . . . . . . . . . . . . . . . . . . . . 25
PXTEL01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DESCRIPTION OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LED STATUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Page
3 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Symbols and glossary
Rapidly flashing warning light.
Slowly flashing warning light.
INSTALLER: any person or business responsible for planning, install-
ing and programming the system.
USER: any person using the security alarm system.
This symbol shows which parts describe safety issues.
This symbol shows parts which must be read with care.
Warning light off.
Permanently on warning light.
Flashing warning light.
Usage conditions
Description for use
The security alarm control units of the PXC2 (PXC2-32, PXC2-64,
PXC2-212) series are designed to enhance security in both homes
and service-sector businesses.
Any installation and/or use other than that specified in this
manual is forbidden.
Warranty and limits of liability
Our product warranty refers to restoring compliance to the prod-
ucts through repairs or free replacement of any materials found to
be non-compliant due to defects resulting from errors in the manu-
facturing process, including any expenses incurred due to products
having to be replaced (interventions, shipping...).
Sellers of CAME SpA products are directly liable to consumers, and
have the function of upholding this right of warranty on our products.
Consumers must apply to the seller, and only the seller, who supplied
the goods, when upholding this right, and must also report any faults
and defects of the product to the seller within two months of noticing
them.
The warranty is invalidated if the User fails to point out the fault with-
in the times indicated above. A claim is never grounds for the final
customer to cancel or reduce orders, nor for the payment of com-
pensation of any kind on our part. Our warranty lapses if the parts
returned as faulty have been tampered with or repaired in any way.
Came SpA cannot be considered liable in the event of damage caused
by improper use of its products. In as much as it is the installer who
designs and installs the security alarm system using both CAME SpA
and those of third parties, the Company cannot vouch for the relia-
bility of the security alarm system. CAME SpA denies any liability for
claims made by the User, Installer or third parties in connection with
the use and installation of our products.
Important for SAFETY
If properly planned, the security system guarantees a high level of
safety to the buildings where it is to be used and the Users who will
use it. To ensure this, certain rules must be followed:
The installation must be carried out by qualified, expert staff and
in full compliance with applicable laws.
Check main power source connections and relative ground con-
nections.
Once the system is up and running, make sure users have
changed the factory User Code (123456).
Maintenance on the system must only be carried out by qualified
personnel; do not try to tamper with the system; you risk compromis-
ing its proper working order, and risk electrocution due to the voltage.
sms
CAME CLOUD
Page 4 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
System installation
System cabling
PXMC3G
3G communication
module
PXONV
ONVIF video-camera
connection module
PXSEA/PXSEG
Outdoor siren
Telephone
Tablet/Smartphone
Modem router
Switch
PXTEL01
PSTN module
PXIPC01
Cable for
programming
PXWRC04/PXWRC16
Remote control
PXWRX01
Wireless receiver
PX4IOR
Expansion module 4 I/O
PXTAG01
Transponder key
PXITU01
Key reader for
transponder key
Smartphone
PXKTN02
Wired keypad
PXWCOB01
Wireless perimeter
detector
PXWIR01
Wireless volumetric
detector
Home automation
CAME Domotic 3.0
LAN network
INTERNET
Bus RS485
PSTN line
Internal connection
Standard connection
Wireless connection
Tablet
PXDGWF
DONGLE wifi
PXALS1501/PXALS3001
Additional power driver
Page
5 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Control unit installation
CONTROL UNIT PXC2 TECHNICAL CHARACTERISTICS
DESCRIPTION
PXC2-32 PXC2-64 PXC2-212
Basic connection points in the control unit
888
External connection points
24 56 204
Total connection points
32 64 212
RS485 Bus lines
122
Number of I/O wire modules
Connectable on bus
16 PX4IOR 32 PX4IOR
Distributed on the 2 bus lines
64 PX4IOR
Distributed on the 2 bus lines
Control unit relay outputs (programmable)
123
Areas
4816
Scenarios
32 32 32
Key readers
4816
Keypads
4 (1 wired, 3 wireless or
wired)
8 (1 wired, 7 wireless or
wired)
16 (1 wired, 15 wireless or
wired)
Transponder keys
99 999 999
Digital key combinations 1,000,000 1,000,000 1,000,000
User codes
99 999 999
Transmitters
83232
Wireless receivers on bus
2816
Events (*)
1,000 10,000 10,000
PSTN module
Optional (PXTEL01)
3G Module
Optional (PXMC3G)
Processing and signal priorities 1) Alarm/burglary, 2) Sabotage, 3) Fault/Exclusion
Speech synthesis
Standard
Telephone numbers
81632
Power-supply units on BUS
248
LAN interface
Standard Standard Standard
Control via SMS
With PXMC3G module
Remote control with voice guidance
With PXSV and PXTEL01 or PXMC3G modules
Wi-Fi connection
Through PXWIFI module
Cloud Connection
Standard
Live video check (ONVIF cameras)
With PXONV module
ID Contact protocol on PSTN
With PXTEL01 module
ID Contact protocol on GSM
With PXMC3G module
SIA-IP protocol
With PXMC3G module or via LAN
Power supply unit (A)
235
Casing
Metal Metal Metal
Dimensions
(405x295x90) 405x295x90 490x360x90
Fittable battery (Ah)
7.2 17 17
Environmental class
222
Regulatory compliance
EN 50131-6, EN 50131-
Grade 2
EN 50131-6, EN 50131- 3
Grade 2
EN 50131-6, EN 50131- 3
Grade 3
(*) Control unit events are stored in a non-volatile FLASH memory that does not require power to guarantee data storage. A minimum
data storage life of 40 years is guaranteed.
Page
6 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
RS-485 Bus cabling
If the remote devices are properly installed, all the bus communication LEDs featured on each device should flash. If any of them are
not flashing it means that the device has not been correctly installed and programmed (check wiring, address and programming in control unit).
TRADITIONAL CABLING (INPUT - OUTPUT)
BRANCHED-OUT CABLING
Branching out consists of a cable with three pairs, two of which are twisted (each pair is made up of conductors A and B).
Analysing the circuit made in this way it is noticed that the structure of the RS-485 bus is still linear (input-output).
Page
7 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
DOUBLE-BRANCH CABLING
Page
8 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
CABLING WITH BUS AMPLIFIER
PXABR
Page
9 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
For long bus sections always install
the 150 ohm resistors between terminals A and B on both ends of
the bus.
Always set up the bus wiring in “input and output” mode. Do not
cable the bus in star configuration.
If this configuration is required follow the directions in this chapter.
CHOOSING THE CABLE SECTION FOR THE RS-485 BUS
For the RS-485 bus it is suggested to use the following cable:
Twisted and grade 4-screened cable (600/1000 V).
A twisted pair for data with cross-section 2x0.22 mm².
A pair to power the 2x0.5 mm² or greater cross-section depending
on distances and voltages (check table below).
Below is the table for calculating the cross-section of power cables
with varying distances and power draws.
Any drops in power voltage must not exceed 1.4 V (voltage
measured on terminals of the power supply and those of the device
on the remotest bus).
MAXIMUM
CABLE LENGTH RS-
485
POWER ABSORPTION
0.1 A 0.25 A 0.5 A 1 A
CROSS-
SECTION
0.5 mm2175 m 70 m 35 m 17 m
0.75 mm2262 m 105 m 52 m 26 m
1 mm2350 m 140 m 70 m 35 m
1.5 mm2525 m 210 m 105 m 52 m
If a cable does not have the proper section additional auxiliary power
sources must be added.
Example:
If we have:
• PXC2-32
• PXKTB02 (maximum consumption 60 mA)
• PX4IOR (maximum consumption 40 mA)
• Sensors connected to the remote expansion inputs (total consump-
tion 150 mA)
• Connection distance 200 m.
With maximum consumption of 250 mA in this case we can either
use a 1.5 mm² section cable, or a 0.5 mm² section cable plus an aux-
iliary power supply connected at the end of the line as shown below:
APPLICATION NOTES ON BUS RS-485 CABLING
Cabling of the bus connecting the control unit to the plugs, bus am-
plifiers and keypads must follow the rules dictated by the RS-485.
Only use a screened and twisted cable with section of at least:
• 2x0.5 mm² for power supply and twisted 2x0.22mm² for data.
• 2x0.5 mm² for power supply and twisted 2x2x0.22 mm² for data
(used to perform branching).
The braid must always be continuous and connected to the control
unit’s negative (-) terminal.
The maximum length of the cable (max sections of 800m) and the
cross-section of the conductors depend on the number of modules
and the overall draw on the different bus sections. When power draw
increases the voltage drop on the cables increases and so reduces
the power supply current to the devices on bus.
The voltage at all + and - terminals of the devices on bus (keypads,
plugs, modules, ...) must not fall below 12 V DC.
If less, add an auxiliary power source and disconnect the positive
while keeping the negative mutual.
Greater than 12 Vdc
YES
NO
4,7 KOHM
4,7 KOHM
Page
10 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Maximum communication performance is guaranteed by
using the specified cable (PXC75). The maximum communication
speed between the peripherals is 115,200 baud. If the cable speci-
fied is not used or if there are problems at installation, the control unit
transfer speed can be decreased (38,400, 9,600, 4,800 and 2,400
baud). The speed of the peripherals is set automatically.
Inputs cabling
Balancing is done with 4.7 kohm resistors at 5%, with 2.2 kohm for
Triple Balancing.
If it is necessary to use different balancing resistors, they can be set
up using the PXC2-Manager programming software.
The following values can be set via PXC2-Manager:
1K0,1K2,1K5,1K8, 2K2, 3K3, 3K9, 4K7, 5K6, 6K8, 8K2, 10K, 12K ohm
Yellow 4
Purple 7
Red x100
Gold 5%
NORMALLY OPEN (NO)
NORMALLY CLOSED (NC)
SINGLE BALANCING (SB)
DOUBLE BALANCING (DB)
DOUBLE BALANCING (DB)
ALARM
TAMPER
To guarantee compliance with standard EN50131 grade 3 the
inputs must be: Single/Double/Triple balanced.
RS-485 CABLE
Shielded 2x1.5mm² + 2x0.22mm² twisted
Control unit BUS device
RS-485 CABLE
Shielded 2x0.5mm² + 2x0.22mm² twisted
Control unit Auxiliary
power supply
Device
on bus
+ - TC TAMPER ALARM
4,7 KOHM TAMPER
2,2 KOHM4,7 KOHM
ALARM 2 ALARM 1
Page
11 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
PULSE OR INERTIAL COUNTER (IC)
DOUBLE BALANCING SENSOR (DB) WITH MICROWAVE BLOCK WHEN
CONTROL UNIT IS OFF (TC)
- If a relay is used inside the control unit:
RT: tamper resistance
R1: alarm resistance 1
R2: alarm resistance 2
To comply with EN50131-3, anti-mask signals must be confi gured
as “fail” or “instant” inputs.
TRIPLE BALANCING (TB)
DOUBLE BALANCING SENSOR (DB)
- If a terminal is used as an output from the control unit:
If you want to connect a LED to the output, it is advisable
to use a relay as in the diagram shown here. Otherwise the LED may
remain slightly lit even in stand-by.
CONNECTION OF A SENSOR WITH ANTIMASK USING THE TRIPLE
BALANCING
Page
12 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Main control unit components
PXC2-32 / PXC2-64 PXC2-212
230 Vac mains connection terminals. Be careful, live parts
Earth Faston / Terminal connection
Earth connection cable for cover
Battery-connection cables. Respect the polarity (red = +, black = -)
Control unit tamper
The battery must be secured to the control unit mechanics using double-sided tape.
- use a VRLA (valve regulated lead acid) battery
- the battery casing must be flammability standard UL94V-1 or higher
- the battery must comply with standard IEC 60896-21:2004 and/or IEC 60896-22:2004.
- the battery must be replaced by an experienced technician.
In the PXC2-212 control unit, the battery must be installed with the fuse holder supplied and a 6 Ah fuse.
LIST OF ELECTRICAL AND MECHANICAL CHARACTERISTICS
CONTROL UNIT MODEL PXC2-64 PXC2-212
Input power supply voltage 230 V AC; 50-60Hz
Output rated voltage 13.8 V DC
Battery charger voltage (type A – EN50131-6)
13.8 V DC
0.75 A
13.8 V DC
1.1 A
13.8 V DC
1.5 A
Output voltage range 9-14.0 V DC
Overcurrent protection 17.5 V DC
Maximum current draw 0.42 A @ 230 V AC 0.56 A @ 230 V AC 0.85 A @ 230 V AC
Control board current draw 150 mA 150 mA 150 mA
Low SD level (battery) 11.4 V 11.4 V 11.4 V
Power supply outputs fault voltage 9.8 V 9.8 V 9.8 V
Intervention voltage for SD deep discharge protection 9.5 V 9.5 V 9.5 V
Maximum ripple on the output power supply voltage 200 mV 200 mV 200 mV
Alarm transmission operating mode Pass-through
Operating temperature - 10 to + 40 °C
Maximum humidity (not condensed) 75%
IP protection rating 30
ATS classification [EN50131] SP3
Casing size (mm) 405x295x90 490x360x90
Safety rating EN50131-3 2 2 3
Safety rating EN50131-6 2 2 3
Environmental class II II II
Maximum degree of pollution 2 2 2
Compliant with EN60950-1, EN50130-4-1, EN50131-1, EN50136-2
IMQ certification
Page
13 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Board description
RS485 BUS
RS-485 bus terminals for connecting keypads, remote mod-
ules and key readers.
[+,-] bus power-supply.
[A,B] data.
[F6] for PXC2-32: 0.75 A self-resetting fuse
[F6] for PXC2-64: 1.1 A self-resetting fuse
[F6] for PXC2-212: 1.5 A self-resetting fuse
PXC2-32 has only one RS485 BUS while PXC2-64
and PXC2-212 have two RS485 BUSes
Connection Points
Control unit connection points, can be inputs of NO, NC, SB,
DB, TB, CI type or outputs.
[+,-] power supply.
[1, 2, 3, 4, 5, 6, 7, 8] If set as inputs.The reference is at
negative.
If they are set as outputs they are open collector outputs pro-
grammable to negative and protected by a 100 ohm resistor
(ON = 0 Vdc, OFF = NO).
[F3] for PXC2-32: 0.75 A self-resetting fuse
[F3] for PXC2-64: 1.1 A self-resetting fuse
[F3] for PXC2-212: 1.5 A self-resetting fuse
A short circuit with open collector output active for
a prolonged time can lead to the protection resistance failure
Control unit output terminals.
[AUX +, -] power supply available in output protected by
self-resetting fuse F5.
[NO, C, NC] relay 1, General alarm relay with dry contacts
[NO, C, NC] relay 2-3, Programmable relay with dry contacts
[F5] for PXC2-32: 1.1 A self-resetting fuse
[F5] for PXC2-64: 1.1 A self-resetting fuse
[F5] for PXC2-212: 1.5 A self-resetting fuse
Tamper
[T, +] terminals for the control unit tamper connection.
[JP1] jumper to enable / disable the tamper (position C to
disable the control unit tamper, position O to enable it). For
additional details, see the TAMPER chapter.
DipSwitch
Dip 1 is used to set the control unit from service to maintenance
(ON = Maintenance, OFF = Service)
Dip 2 is used to reset the Codes and Keys to the factory value.
Dip 3 is used to reset the parameters to the factory value
Dip 4 is used to enable the control unit firmware programming
PXMC3G
[CN1] Connector for PXMC3G module
PXTEL01
[CN2] Connector for PXTEL01 module
Additional modules
[CN3] connector for the PXONV connection module.
Ethernet connector
Ethernet connector for connection to the local LAN network
USB Device Connector
USB Device connector for programming through PXC2-Man-
ager
SD Card Slot
Slot for installing an SD card for storing CCTV camera videos
Reset button
[P1] button to restart the control unit (it is not used to restore
parameters; it does not modify the configuration).
Short press: system reset software. The system restarts
maintaining all the statuses unchanged
Long press (more than 5s): system hardware reset. The sys-
tem restarts and all internal statuses are reset. Equivalent
to completely shutting down the system (battery + network)
Power supply
[Vac] Power supply connection connector
Page
14 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Status LED
Status LED for checking the correct operation of the security
control unit
LED1 green:
- the system is off
- the system is in operation
- during initialization
LED2 red:
- Communication with RS485 BUS peripherals
LED3 green:
- battery not installed or discharged
- battery charged
LED4 red:
- configured system
- system in peripheral configuration (at start-up or after
exiting the technical menu)
Led5 green:
- inactive telephone indications
- telephone indications in progress (both outgoing and
incoming)
Led6 red:
- no connection to Came Connect
- system connected to Came Connect
- device connected remotely
Led7 Green:
- unpowered system
- powered system
Wall-mounting
PXC2-32/PXC2-64 PXC2-212
Install the control unit in a place away from access points and difficult to identify.
Fix on a wall suitable to sustain the control unit over time.
Prepare the holes and channel for cable passage before installation.
Use the 4 holes for fixing to the wall and use 6 x 30 mm plugs with screws 4.5 x 40 mm or higher.
The control unit must be installed at a maximum height of 2m.
Battery
[Vbat] Battery connection connector.
USB Host Ports
USB host ports for connecting the WiFi dongle and for updat-
ing the control unit and peripherals on the 485 bus through
USB key.
+-
Page
15 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Cabling
230 VAC
PCX2-32/64/212
PE
Disconnect the magneto thermal switch associated with the control unit, before cabling the 230 Vac network and for the entire time that
the control unit is open.
Handling 230 Vac cables is dangerous; danger of death by electrocution. Connect the earth via a Faston to the corresponding connector.
Connecting the earth must be done according to current regulations.
Connect the 230 Vac Line and Neutral cable to the transformer terminals.
Lock the 230 Vac power cable to the casing so that it cannot move even if the terminals are disconnected.
Before closing the control unit, always check that all of the metal parts are connected to earth (control unit and cover).
Reconnect the magneto thermal switch associated to the control unit only once the cabling inside it are finished.
A suitable double-pole disconnection device must be installed for the installation to be to standard. This device must be outside the con-
trol unit and easily accessible, and the distance between contacts must be at least 3 mm. This is so as to comply with current standards. An
example device is a double-pole circuit breaker.
BATTERY
The battery is the secondary power source for the security alarm
control unit.
CAUTION! THERE IS DANGER OF THE BATTERY EXPLODING IF
IT IS REPLACED WITH THE WRONG TYPE.
DISPOSE OF THE USED BATTERIES FOLLOWING THE INSTRUC-
TIONS.
Respect the polar-
ities of the battery
when connecting.
Page
16 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
SD TYPE (BATTERIES) CAN BE USED, SPECIFIC TO THE OUTPUT TERMINALS
CONTROL UNIT MODEL PXC2-32 PXC2-64 PXC2-212
Type of SD (buffer bat-
tery)
Battery type Rechargeable lead battery with flammability class of the casing UL94-V2 or
better
Nominal voltage 12V
Nominal capacity 7Ah 7Ah 18Ah 7Ah 18Ah
Loading time 24h (80% charge)
Maximum internal resistance 1.5 Ohm 1.5 Ohm 0.5 Ohm 1.5 Ohm 0.5 Ohm
Maximum current deliv-
erable at 12V
Total 2A 3A 5A
BUS output 0.5A 1A 1.5A
Connection points output 0.5A 0.75A 1.5A
Auxiliary output 0.75A 0.75A 1.5A
Maximum current deliv-
erable at 5V USB output 0.5A 0.5A 0.5A
Maximum current per connection point
as an output 100mA 100mA 100mA
Motherboard consumption 150mA 150mA 150mA
Modules consumption on motherboard (3G in coupling) 800mA 800mA 800mA
3G consumption on call 300mA 300mA 300mA
PSTN 30mA 30mA 30mA
WiFi dongle 230mA 230mA 230mA
TAMPER
CONTROL UNIT TAMPER ENABLED (JP1 on 0)
To guarantee compliance with standard EN50131 grade 3, the
tamper CANNOT be disabled.
ANTI-OPENING TAMPER-PROOF INSTALLATION
CONTROL UNIT TAMPER DISABLED (JP1 on C)
Drill the container on the right side of the control unit with a drill
for iron so that the tamper can be fixed with the screw (short) in a
horizontal position.
Fix the tamper on the right side of the control unit with the sec-
ond screw (short).
ANTI-OPENING AND ANTI-TEAR TAMPER INSTALLATION
Drill the wall (with a tip suitable for the dowel supplied) at the
height of the hole in correspondence with the tamper.
Insert the appropriate screw (long) on the hole on the right side
of the control unit, screw the shim and fix with the locking nut. The
tamper must be able to rotate.
Adjust the height of the plug screw so that when the cover is
closed the tamper lever closes.
To guarantee compliance with standard EN50131 grade 3, the
control unit tamper must be mounted in anti-opening and anti-re-
moval mode.
APF22
Page
17 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
OUTPUTS
All connection points of the control unit can be programmed as inputs
or outputs. If programmed as outputs they are of Open Collector type
which provide a negative when they are active.
A 12 VDC short circuit with an active output for a prolonged time
can lead to the protection resistance failure.
Use of standard relays
use of RL002 card
• Indication devices
Acoustic/Visual (max load 50mA):
If you want to control a relay with an Open Collector output (or relay
output), it is necessary to add a diode (1N4007) in parallel to the
relay coil.
RELAY 1 - RELAY 2- RELAY 3 ALARM RELAY OUTPUTS
Relay outputs 2 and 3 are programmable, while relay output 1 always
follows the general alarm and sabotage status and remains active for
the programmed time.
Note: PXC2-32 has only relay 1, PXC2-64 has Relay 1 and Relay 2,
while PXC2-212 has Relay 1-2-3.
Siren not self-powered
Self-powered siren
08:24 19/03/13
#####UUUPX---
08:24 19/03/13
#####UUUPX---
08:24 19/03/13
#####UUUPX---
08:24 19/03/13
#####UUUPX---
Page
18 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Keypads - PXKTB02/PXKTN02
Capacitive "Flat" black (PXKTN02) or white (PXKTB02) keypads con-
nectable on Bus. Wall or flush mounted.
TYPE B ACE device, EN50131 GRADE 3 certified ( ).
BOARD DESCRIPTION
PXKTN02
PXKTB02
RS-485 bus terminals for connecting keypads and key readers:
[+,-] bus power supply;
[A,B] data
Terminals 1,2 : Connection points
Anti-opening / anti-tear tamper.
Red LED signalling communication on the bus. If it flashes it
means that the keypad communicates with the control unit
Keypad buzzer.
In compliance with EN50131, after 5 invalid attempts to access the
keypad using the PIN, access is blocked for 100 seconds.
After 21 invalid attempts, the system generates a device tampering
alarm.
INSTALLATION
The keypads must be installed on the wall in sheltered, raised or
recessed areas with an OPALESI box (PXWKTN01/PXWKTB01 only).
Connect the control unit and keypads to the respective terminals [+
A B -].
ADDRESSING
The keypad addressing is performed directly on the keypad through
the local menu.
KEYPAD DISPLAY
The display is made up of 2 rows of 16 characters each. The keypad
in stand-by goes in “Energy saving” mode decreasing its light inten-
sity after a set time.
Under the display there are 16 numbers which make it easier to in-
terpret the second row of the display. Its key for understanding is:
# = area on;
U = area in turning-on phase (output time counting in progress);
X = area turning on but not ready for arming because there are open
inputs;
P = area partially on (there is at least one input associated to the
area temporarily disabled);
A = area in alarm status;
R = area in active patrol function;
N = area disabled not ready
- = area off;
= area not managed by the keypad.
Example: reading of display represented:
Managed areas: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13.
Unmanaged areas: 14, 15, 16.
On areas: 1, 2, 3, 4, 5.
Area in turning-on phase: 6, 7, 8.
Areas partly on. 9.
Area not ready: 10.
Areas off: 10, 11, 12, 13.
Page
19 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
DISPLAY ICONS
Icon Meaning
CAME logo
System armed
System not armed
System partial armed
Programming
Event memory
User menu
Alarm memory
Not ready for arming
Generic power supply malfunction
230 V network power supply malfunction
Battery malfunction
PSTN line malfunction
GSM line malfunction
Serial connection (local)
Ethernet connection (remote)
SYSTEM STATUS INDICATIONS
The system status signals operate according to the installer pro-
gramming. Depending on the programming, the display can always
be kept visible (LED and display visible) or can activate the Masking
mode (No information is given on the system status).
In Masking mode
Only the RED LEDs of the key readers and YELLOW ones for the key-
pads indicate that there are events to be displayed.
All other signals are displayed when accessing the keypad and the
key readers for the programmed time (30 seconds max.).
SYSTEM STATUS ALWAYS DISPLAYED
LEDs Status Indications
(green)
It indicates that there are open inputs. If a sce-
nario is started up an alarm could be generated.
Check the open inputs in the scenario's start-up
phase.
It indicates that NO inputs are open. The system
can be turned on with no problem.
(green)
It indicates that the managed areas are off (sys-
tem off).
It indicates that all the managed areas are on
(system totally on).
It shows that at least one managed area is on
(system partially on).
LEDs Status Indications
(red)
It indicates that the managed areas are not in
alarm status
It indicates that at least one managed area is in
alarm (the system is alarm status).
It indicates that the associated system has de-
tected and alarm, and that it has been muted. See
the events list for the list of alarms.
(yellow)
It shows that there are no malfunctions in the
system.
Indicates that an active fault is present
When the 'Status Masking' function is active, it in-
dicates the presence of an event to be displayed.
It indicates that there is no faults memory in the
system.
= Off = On steady = On flashing
The indication of events that occur at the same time follows
the following priority: alarms, output times, faults. The displaying on
the monitor is made cyclically.
Each keypad only displays the statuses of its areas of compe-
tence
ALPHANUMERIC KEYPAD
Buttons Functions
The alphanumeric buttons are for entering access
codes, selecting areas in during the powering on
phase and for changing parameters.
Browsing and selecting buttons
Parameter changing buttons.
After entering the code, it grants access to the User
Menu. Pressed for more than 5 seconds allows ac-
cess to the keypad menu.
Scenarios launching buttons.
Button for turning off the system.
KEYPAD MENU
The Keypad Menu is independent from the control unit menu and
allows to set different keypad features such as the language, con-
trast and brightness of the display, lighting of the buttons and of the
system status LEDs, and other functions as shown in the following
table.
To enter the Keypad Menu, press and keep pressed for a few seconds
, until the display shows KEYPAD LANGUAGE. Then use the buttons to
navigate and select as shown.
Pressing 2 times consecutively [#], the Keypad Menu is closed. After
xx seconds without any action, the keypad enters in STANDBY mode
and after further xx seconds it automatically exits from the Keypad
Menu. The LEARNING menu is available only on wireless keypads.
Page
20 - Manual FA01869-EN - 08/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
MENU ITEMS VALUES
LANGUAGE
KEYPAD
-> Italiano - English
Français - РУССКИЙ
<-
ADDRESS
KEYPAD
-> ADDRESS
N.--XX
<-
TAMPER -> ENABLED/
DISABLED
<-
CONTRAST
DISPLAY
->
<-
BRIGHTNESS
DISPLAY
->
<-
LIGHTING
KEYPAD ON
->
<-
LIGHTING
STANDBY KEYPAD
->
<-
BRIGHTNESS
STATE LED
->
<-
PXITU01 key reader and PXTAG01 key PXTAG01/PCT/TST01 keys
The PXITU01 key reader is a transponder reader of PXTAG01 keys,
which allows to manage the alarm system when turning on and off
using up to 3 scenarios that can be changed.
EN50131 GRADE 3 certified device ( ).
The key is used to manage the system through key reader. It does
not contain batteries and to work it must have been previously ac-
quired by the control unit.
Each key is uniquely recognized within the control unit and the event
memory.
If in the
SPECIAL FUNCTIONS
of the technical menu the
PRE-ARMING TEST
has been enabled, in the case of existing anomalies in the system
(no telephone line, no communication with at least one device in the
system, etc.) the starting of the scenarios through the key reader will
be inhibited (the key reader emits a beep and cancels the operation).
hole cover cap, civil series
transponder key reader
warning LED
key sensitive zone
MENU ITEMS VALUES
BUZZER -> ENABLED/
DISABLED
<-
BUTTON MODE
WAKEUP
-> VALID/
NOT VALID
<-
KEYPAD CLEANING
-> 30 s
<-
VERSION
KEYPAD
-> CAME
v.X.YY BUILDN
<-
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

CAME PXC2 Installation guide

Type
Installation guide