  • Hello! I am an AI chatbot trained to assist you with the Zodiac PW 5M Instructions For Installation And Use Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PW
5M-7M-9M-11M
Ver. : 11/2011
SA
H0357903.A1.SAVer.11/20111
Summary
Installation......................................................................................2
1.1General..............................................................................................................2
1.2Operatingconditions.........................................................................................3
1.3Installation.........................................................................................................3
Operation........................................................................................6
2.1TheControlPanel..............................................................................................6
2.2Checkstobeperformedbeforeoperatingtheappliance.................................7
2.3Startingtheappliance........................................................................................7
2.4Checkstoperformafteroperatingtheappliance.............................................7
2.5Winterizing........................................................................................................8
Maintenance...................................................................................8
3.1Maintenanceinstructions..................................................................................8
3.2Recyclingtheproduct........................................................................................9
3.3Additionalrecommendations............................................................................9
Errorcodes....................................................................................10
FAQ................................................................................................11
Technicalinformation....................................................................12
6.1Technicalspecifications...................................................................................12
Warranties.....................................................................................12
Registrationonline........................................................................14
Conformitycertificate....................................................................14
Pleasereadthismanualcarefullybeforeinstalling,maintainingorrepairingthis
appliance!Thesymbolindicatesimportantinformationthatmustbetakeninto
accountinordertoavoidriskofpersonalinjuryand/ordamagetotheappliance.The
symbolindicatesusefulinformation.
Aspartofourcontinuousimprovementpolicyourproductsmaybesubjecttochange
withoutnotice.
Availableintheappendixesattheendofthemanual:
- electricaldiagram
- dimensions
H0357903.A1.SAVer.11/20112
Installation
1.1General
1.1.1Caution
1.1.2Generaltermsofdelivery,storageandtransport
Anyequipment,includingcarriageandpackingfree,isshippedattherecipient’srisk.
Exclusiveuse:heatingswimmingpoolwater(notbeusedforanyother
application),
theproductmustbeinstalledbyaqualifiedtechnicianaccordingtothe
manufacturer’sinstructionsandincompliancewithlocalregulations.The
installerisresponsibleforthecorrectinstallationofthedeviceandalsofor
ensuringcompliancewithlocalregulationsinthisrespect.Themanufacturer
willnotbeheldresponsibleforanypotentialissuesthatmayariseduetofailure
tocomplywithlocalregulationspertainingtoinstallation,
incorrectinstallationmaycauseseriousdamageand/orpersonalinjuries
(possiblydeath),
thatthisdevicemustbehandledbycompetentandcapablepeople(physically
andmentally)whohavereceivedadequateinstructionsforuse(byreadingthe
userguideorasinstructedbytheinstaller).Personswhodonotsatisfythese
requirementsmustnothandletheappliancesoastoavoidexposureto
potentiallydangerousparts.
Intheeventofmalfunctiondonotattempttorepairtheapplianceyourself:call
yourretailer,
beforeworkingontheappliance,ensurethatthepowersupplyisdisconnected
andsecured,
Priortoanyoperation,checkthat:
- Thevoltageontheidentificationplateoftheappliancecorrespondstothe
mainvoltageavailableonsite,
- thesocketandthepowersuppliedareadaptedtothepowerrequirements
oftheheatpump,andthattheyaregrounded,
- theelectricalplugisadaptedtothesocketavailable.
eliminationorshuntingofoneofthesafetyleadsautomaticallytothe
cancellationoftheguarantee,asforthereplacementofpartsbynonoriginal
parts,
Keeptheapplianceoutofthereachofchildren,
DonotventR410Aintotheatmosphere:R410Aisafluorinatedgreenhousegas,
coveredbytheKyotoProtocol,withaGlobalWarmingPotential(GWP)=1975‐
(DirectiveoftheEC842/2006).
H0357903.A1.SAVer.11/20113
Inthecaseofdamagecausedduringshippingtherecipientmustmentionany
reservationsinwritingonthecarrier'sdeliverynote(confirmationtobesenttothe
carrierwithin48hoursbyregisteredmailandAcknowledgementofReceipt).
Iftheappliancehasbeenturnedonitsside,mentionyourreservationsinwritingto
thecarrier.
1.1.3Contents
X1x2
1.2Operatingconditions
Operatingrange:
between7°Cand32°Cofairtemperature
between10°Cand32°Cofwatertemperature
1.3Installation
1.3.1Selectinganinstallationsite
theheatpumpmustbeinstalledataminimumdistancefromtheendofthepoolso
astoavoidexposuretowatersplashes.Theappropriatedistanceshouldbedefined
withreferencetothenationalelectricalstandardsthatapplyinthecountryof
installation.
Theheatpumpmustnotbeinstalled:
- nearaheatsourceornearinflammablegas,
- neararoadwithariskofwaterandmudsplashes,
- facingstrongwind,
- withtheventfacingtowardapermanentortemporaryobstacle(window,wall,
hedge,etc…),itmustbeatleast3metersfromsuch.
1.3.2Installingtheappliance
placeontoastable,solid(concreteslabtype)and
levelsurface,
protectfromrisksoffloodingduetocondensation
producedbytheappliancewhilstitisoperating.
Theappliancemustbeinstalledoutdoorsandtheremustbeadequateopenspace
surroundingit(see§1.3.3).
Donotpickuptheunitusingtheoutercasing,usethebasetoliftandmovethe
unit.
Fixingholes
H0357903.A1.SAVer.11/20114
1.3.3Hydraulicconnections

ConnectionsshouldbemadeusingØ50PVCpipe,gluingthepipeworkconnectorsto
theswimmingpoolfiltrationsystem,afterthefilterandbeforeanywatertreatment
system.Inordertoensurethewatertightnessbetweenthesejointsandtheheat
pump,wrapTeflontapearoundthethreadingofthewaterintakeandoutput.
Evenifthewaterflowislowerthan8m³/h,itisrecommendedthatabypass
installationbeused(valveVBclosed,valvesVEandVSopen)soastofacilitate
interventionsontheappliance.
Respectthedirectionofthehydraulicconnection(see§"Dimensions"inthe
appendix).
Itispossibletofixtheappliancetothegroundusingtheholesinthebaseofthe
applianceorusingfixingrails(notsupplied).Itisalsopossibletofixtheappliance
withbrackets(notsupplied).
Adrillingexplanationdiagramisavailableontherearofthepackagingbox.
*Minimumdistance
filter
watertreatment
bypass
Withoutbypass
Withbypass
(recommended)
H0357903.A1.SAVer.11/20115
Installingabypassismandatoryifthewaterflowishigherthan8m³/h,usevalveVBto
adjustthewaterflowandleavevalvesVEandVSopen.
PW5M 7M 9M 11M
Testpressurebar 6
Operatingpressurebar 1.5
HeadLossmCE 2.3 2.45 4.95 5
Minimumwaterflowratem³/h 2
Averagewaterflowratem³/h 3 4 5 5
Maximumwaterflowrate*m³/h 8
*thisflowratemustnotbeexceeded
1.3.4Electricalconnections
theunitisdesignedforconnectiontoageneralpowersupplywithfullearthand
neutralorneutralearthsystems,
electricalprotection:bycircuitbreaker(curveD)orfuse(Am),andwitha30mA
differentialtripswitchattheheadofthesupplyline(circuitbreakerorswitch).
PW5M7M9M
connectthepowercordsuppliedwiththeappliancetoa16Asocketcomplyingwith
thestandardsandregulationsinforceinthecountrywhereitisinstalled,
extensioncordsandadaptersmustnotbeused,
Ifthepowersupplycableisnotlongenough,contactaqualifiedtechnician.
PW11
theelectricalsupplyoftheappliancemustcomefromaprotectionandswitching
device(notsupplied)complyingwiththestandardsandregulationsinforceinthe
country,
theelectricalsupplycablemustnotbeexposedtoelementsthataresharp,hotor
representacrushhazard,
checkthatallcablesaresecureandallterminalconnectionsarecorrect.
Looseterminalsmaycausethesupplyterminalboardtooverheat, andwillvoid
thewarranty.
Theappliancemustbeearthed.
Acceptabletolerancefortensionvariation:‐10%,+7%(whileoperating)
Riskofelectricalshockinsidethedevice.
Onlyafullyqualifiedandapprovedtechnicianshouldperformcabling
connectionsinsidetheappliance.
Ifthepowercableisdamageditmustbereplacedbyaqualifiedtechnician.
H0357903.A1.SAVer.11/20116
supplycablesection:forcablesofamaximumlengthof20metres(calculationbase:
5A/mm²),mustbecheckedandadapteddependingoninstallationconditions
PFPVoltage
Maximumcurrent
consumptionCablesectionElectricalprotection
Amm²  A
11M230V50Hz15.5 3x2.53G2.5 16
Operation
2.1TheControlPanel
SymbolDesignationNotflashingFlashing Of
f
waterflowWaterflowis
correct
Waterflowtolowor
nowaterflow/
HeatingactiveStartingupinactive
externalpump
(option)Refertothemanualoftheoptionalfeature
ambientair
temperatureSufficientinsufficient/
DefaultSee§4
“on/off”button
Buttonfordisplayingthetemperatureofthepoolwaterorforsetting
parameters
electricalconduitsmustbesecured,
usethestuffingboxtobringthesupplycableintotheappliance.
phase(L)+neutral(N)+Earth(PE)
H0357903.A1.SAVer.11/20117
SymbolDesignation NotflashingFlashing Of
f

settingvaluesbuttons
2.2Checkstobeperformedbeforeoperatingtheappliance
thehydraulicconnectionsmustbetight,
theunitmustbestable(aswellaslevelandupright),
theelectricalsupplycablemustnotbeexposedtosharporhotelementswhichcould
damageitorcrushit.
2.3Startingtheappliance
openthewatersupplyandadjustthevalves,ifany(see§1.3.3),
connecttheheatpumptothepowersupply:then,
toturnontheappliance:pressfor2secondson:
thenbydefaultthescreenwilldisplaytherequestedtemperature,
tosetthedesiredtemperature("requestedtemperature"):whentheheatpumpis
operating,pressonortosetthevalue.
It’spossibletoreadthewatertemperature:whenwaterisflowingthroughtheheat
pump,presson:flashesfor10secondsthendisplaysthe
fixedrequestedtemperature,
It’spossibletolockthekeyboard:
- lockthekeyboard:pressonandsimultaneouslyfor3seconds:
willbedisplayedfor3secondsthen:,
- unlockthekeyboard:pressonandsimultaneouslyfor3seconds:
willflashfor4secondsthen:,
2.4Checkstoperformafteroperatingtheappliance
Afterfollowingthestepsforrunningtheheatpump,temporarilycutthewater
circulationtocheckthattheheatpumpstopsoperating:thewater
flowdiodeshouldflash.
H0357903.A1.SAVer.11/20118
2.5Winterizing
switchofftheheatpumpbypressingthe buttonfor2seconds,thendisconnect
thepowercable,
ensurethatnowaterisflowingthroughtheheatpump,
drainthewatercondenser(riskoffreezing)byremovingthetwopoolwaterinletand
outletconnectionsatthebackoftheheatpump,
inthecaseofafullwinterizingofthepool:connecttheinletandoutletconnections
"lightly"withouttightening(oneturn)inordertoavoidforeignbodiesenteringinto
thecondenser,
inthecaseofwinterizingtheheatpumpalone:donotreconnecttheinletandoutlet
connectors,insteadplacetwostops(supplied)onthecondenserwaterinletand
outlet.
Maintenance
3.1Maintenanceinstructions

ensurethatnoforeignbodiesobstructthefangrid,
cleantheinsideoftheappliance,donotusesolventbasedcleaningproducts,
cleantheevaporator(forplacingsee§“Dimensions”inappendix)withasoftbrush
andafreshwaterhose(disconnectthepowercable),donottwistorbendthemetal
blades,
checkthecorrectoperationoftheregulator,
checkthatthecondensationisdrainedproperlywhilsttheapplianceisoperating.
Thefollowingoperationsmustbeperformedbyaqualifiedtechnician:
checkthecorrectworkingconditionofallsafetycomponents,
checkthatallmetalelementsareearthed,
checkthetighteningandconnectionsoftheelectriccablesandthecleanlinessofthe
electricalequipmentbox,
Ageneralservicingoftheapplianceisrecommendedbothwhenwinterizingand
whenrestartinginordertoensuretheproperoperationofyourheatpump,to
preserveitsperformanceandtopreventpotentialfailures.
Servicingcostswillbebornebytheuser.
Donotuseahighpressurewaterhose.
Toavoiddamagingtheappliancewithcondensation,donotcoveritwithanair
tightcover.
Winterizingisessentialduetotheriskofthecondenserfreezing.Thissituationis
notcoveredbythewarranty.
H0357903.A1.SAVer.11/20119
3.2Recyclingtheproduct
Thissymbolmeansthattheequipmentmustnotthrowitintoyour
householdwaste.Itwillbecollectedselectivelysothatitcanbereused,
recycledorrecovered.Anysubstancesitmaycontainwhicharepotentially
dangeroustotheenvironmentwillbeeliminatedorneutralised.
Enquirewithyourretailerfortheconditionsthatapplytotherecyclingofyourproduct.
3.3Additionalrecommendations
InrelationwiththePressurisedEquipmentDirective(PED97/23/CE)
3.3.1Installationandmaintenance
theunitmaynotbeinstalledclosetocombustiblematerials,ortheairductinletof
anadjacentbuilding.
forcertainappliances,itisessentialtofitprotectiongridsiftheunitisinstalledinan
areawhichisunprotectedandeasilyaccessible.
duringinstallation,repairandmaintenancework,itisstrictlyprohibitedtostepon
pipesandhosesasthesecouldbreakandtheescapingrefrigerantcouldcause
seriousscalding.
whenservicingtheappliance,thecompositionandstateofheatcarryingfluidmust
bechecked,aswellastheabsenceofanyrefrigerant.
duringtheannualunitsealingtestinaccordancewithvalidlegislation,thehighand
lowpressureswitchesmustbecheckedtoensuretheyaresecurelyfastenedtothe
refrigerationcircuitandthattheyshutofftheelectricalcircuitwhentripped.
duringmaintenancework,ensuretherearenotracesofcorrosionoroilaround
refrigerationcomponents.
beforebeginningworkontherefrigerationcircuit,isolatetheapplianceandwait
severalminutesbeforeremovingthetemperatureorpressuresensors.Certain
elementssuchasthecompressorandassociatedpipingmayattaintemperaturesin
excessof100°Candhighpressureswiththeconsequentriskofseverescalding.
3.3.2Repair
allbrazingworkmustbecarriedoutbyaqualifiedbrazer/welder,
replacementpipesmustalwaysbemadeofcopperincompliancewithstandardNF
EN127351.
leakdetection,pressuretest:
- neveruseoxygenordryair,riskoffireorexplosion,
- usedrynitrogenorthemixtureofnitrogenandrefrigerantindicatedonthename
plate,
- thetestpressureforboththehighandlowpressurecircuitsmustnotexceed42
bar.
H0357903.A1.SAVer.11/201110
thehighpressurecircuitpipesaremadeofcopperandhaveadiameterequaltoor
greaterthan1’’5/8.Acertificateasindicatedin§2.1incompliancewithstandardNF
EN10204willberequestedfromthesupplierandfiledintheinstallationtechnical
documentation.
thetechnicaldatarelativetothesafetyrequirementsofthevariousapplicable
directivesmustbeindicatedonthenameplate.Thisdatamustberecordedinthe
unitinstallationinstructionswhichareincludedintheinstallationtechnicalfile:
modelcodeserialnumber,maximumandminimumOT,OP,yearofmanufacture,
EClabel,manufacturer’saddress,refrigerantandweight,electricalparameters,
thermodynamicandacousticperformance.
Errorcodes
DisplayDesignation Cause Solution
Air
temperature
sensorfault
Sensorfaultyor
disconnected
Replacethesensor,contact
yourretaileroraqualified
technician
Defrost
sensorfault
Sensordefective
ordisconnected
Replacethesensor,contact
yourretaileroraqualified
technician
Low
pressure
fault
Gasleakonthe
refrigerating
circuit
Contactyourretailerora
qualifiedtechnician
High
pressure
fault
Insufficientwater
floworfaultyflow
sensor
Checkthewaterflowor
contactyourretailerora
qualifiedtechnician
OtherContactyourretailerora
qualifiedtechnician
Water
temperature
sensorfault
Sensordefective
ordisconnected
Replacethesensor,contact
yourretaileroraqualified
technician
Defrost
cyclefault
(>20
minutes)
Ambientair
temperaturetoo
low
Waituntiltheairtemperature
reachestheoperating
temperaturerange
Thefanisnot
operational
Contactyourretailerora
qualifiedtechnician
Theevaporatoris
cloggedup
Cleantheevaporator(see
§2.1)
Valueforair
temperatureor
defrostisincorrect
Contactyourretailerora
qualifiedtechnician
H0357903.A1.SAVer.11/201111
FAQ
Isitpossibletoimprovethetemperatureperformance?
Aheatpumpisdesignedtoextractheatfromthesurroundingairandtransferitto
thepoolwater.Thehighertheairtemperature,themoreheattheheatpumpwillbe
abletotransfertothepoolwater.
Settingthesetpointtomaximumwillnotheatthewateranyfaster.
Inordertoimprovetheefficiencyofyourheatpumpitisrecommendedthatyou:
- protectthepoolwithacover(floatingcover,rollercover…),soastoavoidheat
loss,
-
chooseperiodswhentheoutsidetemperatureismild(>onaverage10°C)in
ordertofacilitatethetemperatureincrease(thismaytakeseveraldays.The
actualtimewillvaryaccordingtoweatherconditionsandthepoweroftheheat
pump),
- thehigherthesurroundingairtemperature,themoreefficienttheheatpumpwill
be.
Checkthatthefiltrationtimeissufficient:
duringtheheatingphase,watercirculationmustbecontinuous(24h/24),
maintainthetemperaturethroughouttheseason,allowforan"automatic"
circulationofatleast12hrs/day(thelongerthistimeis,themoretimetheheat
pumpwillhavetofunctionandtoheatthewater).
Whyismyheatpumpnotheating?
Severalreasonscouldexplainthissituation:
1. Atstartuptheapplianceremainson"pause"for30secondsbeforeactually
startingup:checkthatthistimehaspassed,
2. oncethepoolhasreachedtherequiredtemperature,theheatpumpswitches
off:checkthatthewatertemperatureislowerthantherequestedtemperature
(see§2.4),
3. whenthereisnowaterfloworwhenitisinsufficient,theheatpumpwillstop:
checkthatwaterisflowingcorrectlythroughtheheatpump,viaanexternal
circulationsystem,thatthepipeworkconnectionsarecorrectandcheckthat
the"waterflow"diodeislitandnotflashing,
4. whentheoutdoorairtemperaturedropsbelow7°C,theheatpumpwillstop:
checktheoutdoortemperatureaswellasthe"surroundingairtemperature"
indicator
5. Theheatpumpmayhavedetectedamalfunction:checktoseeifanerrorcode
isdisplayedonthescreen,ifsoreferto§4.
Iftheproblempersistsafteryouhavecheckedalltheabovepoints,contactyour
retailer.
H0357903.A1.SAVer.11/201112
Theheatpumpisgivingoffwater:isthisnormal?
Yourappliancewillgiveoffwaterintheformofcondensation.Thiswateristhe
humiditycontainedintheairwhichcondensesoncontactwithcertaincold
componentsinsidetheheatpump.
Caution:yourappliancecandrainseverallitresofwaterperday.
Whereshouldmywatertreatmentsystembepositionedwithrespecttothe
heatingsystem?
Thewatertreatmentsystem(chlorinator,saltchlorinator,etc…)mustbeinstalled
preferablydownstreamfromtheheatpump(seeinstallation§1.3.3),andmustbe
compatiblewiththelatter(checkwiththemanufacturer).
Technicalinformation
6.1Technicalspecifications
PW5M 7M 9M11M
Singlephasevoltage 230V50Hz
Powerconsumption* kW 0.98 1.56 2.062.6
Powerrestored*kW 4.65 6.52 8.610.5
Nominalcurrentconsumption* A4.45 7.09 9.3612.4
COP*4.7 4.2 4.24.1
SoundpowerdBA 65.4 66.7 6972
Soundpressureat10meters dBA 37.4 38.7 4144
ProtectioncalibreA16
* withanambientairof+15°Candapoolwaterof24°C,humidity70%
unitprotectionclass:IP24
refrigerantgas:R410A
refrigerantcharge:seeproductinformationplate
Warranties
Principle
Unlessotherwisestipulated,wecontractuallyguaranteethecorrectoperationofour
newProducts.WeguaranteethatourProductsconformtotheirtechnical
specificationsandthattheyarefreeofmaterialandmanufacturingdefault.
Thepresentwarrantyislimited,atourdiscretion,eithertotherepairorexchangefora
neworrepackedProduct,ortotherefundofanyProductsrecognizedasbeing
defectivebyourservices.ShippingexpensesfortherepairedorreplacedProducts
deliveredtotheclientwillbebornebyus.Theguaranteeexcludesanylabourcosts,
traveland/oraccommodationexpensesincurredastheresultofrepairsmadeoutside
ofcontinentalFranceandexcludesanypaymentofdamages.
AllProductreturnsmustfirstbeapprovedanddeterminedbyourservices.Returns
sentbytheClientwithoutourpriorapprovalwillnotbeaccepted.
H0357903.A1.SAVer.11/201113
Inparticular,thesparepartswarrantywillonlybehonouredafteranalysisand
inspectionofthereturnedsparepartsbyourcompanyfollowedbythedecisionto
replacesaidparts.
Inallcasestheseller'slegalwarrantywillcontinuetoapply.
Inordertobenefitfromthewarranty,theClientandtheEndUseragreetorespectthe
followingparametersconcerningthewaterbalanceoftheswimmingpool:pH:6.8<pH
<7.6;freechlorine:<3,0mg/L;totalbromine:<5.0mg/L;stabilisingagent(ifused):<
75mg/L;totaldissolvedmetals(iron,manganese,copper,zinc…):<0.1mg/L
Note:usingwaterdrawnfromawellisforbidden.
Generallimitations
ThepresentwarrantydoesnotapplytovisibledefectsthattheClientfailedtoreport
uponacceptingdeliveryoftheProducts.
Alsoexcludedfromthewarrantyare:defectsordeteriorationduetotheunsuitability
oftheProductwithrespecttotheendUser'sneeds,duetonormalwear,to
negligence,toincorrectinstallationortoausethatdoesnotconformtothe
recommendationsmentionedintheUserManual,tolackofmaintenanceand/ora
handlingaccident,toincorrectstorage,and/orbystudies,instructionsand/or
specificationsmadebyourClient.
AnymodificationsmadebytheClient,bytheEndUserorbyanythirdpartytoour
Productswillautomaticallyvoidthewarrantyinfull.Thesamewillapplyiforiginal
partsweretobereplacedwithsparepartsnotsoldbyus.
OurClientwillberesponsibleforensuringcompatibilityofourProductswithanyother
poolequipmentitmaybeinstalledwith,bycheckingwiththedifferentmanufacturers
concerned,alsoforensuringthatallinstallationandoperatinginstructionsandrules
arerespectedinorderfortheoverallsystemtooperatecorrectly.
Inthecaseofareturnoftheproducttoourworkshop,shippingexpensestoandfro,
willbebornebytheenduser,exceptforthoseexpensesmentionedunderparagraph2
ofthepresentarticle.
Immobilisationanddeprivationofuseofanapplianceduetorepairwillnotgivethe
righttocompensation.
Thiswarrantywillbecomevoidinthecaseofadefaultinpaymentorlatepaymentby
ourClientfortheProductconcerned.
Periodcoveredbythewarranty
Theeffectivewarrantystartdateisthedatementionedonthesalesinvoiceforthe
newProductasissuedbyourClienttotheEndUser.Thisdocumentwillberequiredas
proofofpurchaseinorderforthewarrantytobeeffective.Failingthis,ourClientshall
bearthefullcostofanyclaimsmadebytheendUserunderthecontractualwarranty
andafteritsexpirydate.
Undernocircumstancesshallanyrepairsorreplacementscarriedoutundertheterms
ofthiswarrantycauseitsdurationtobeextendedorrenewed.
H0357903.A1.SAVer.11/201114
ParticulardispositionsforProductsofHeatingandDehumidificationrange
Unlessotherwisespecified,weguaranteethecorrectoperationofournewproducts
installedandputintoservicebyaprofessionalinstaller(excludinginstallationvia
"retrofit"kit")foraperiodoftwoyearsstartingfromthedatementionedonthe
invoiceasissuedbyourClienttotheendUser.Usersarealsorequiredtohavean
approvedtechnicianperformregularmaintenanceonourproducts,asdetailedinthe
instructionsintheproductuserguide.
Thewarrantyonlycoversdefaultsinmaterialsandcraftsmanshipthathavebeen
acknowledgedbyourtechnicaldepartment/services.
Thepresentwarrantydoesnotapplytomalfunctionsand/ordegradationsdueto
externalfactorsunrelatedtous(poorpowersupply,adjustmentofthebypass,
incorrectaircirculation,badinsulationofthepremises,thermalbridges,incorrect
winterization,etc.…).
Theheatexchangeroftheheatpumpsbenefitsfroma5yearwarrantyagainst
corrosion.
Registrationonline
Registeryourproductonourwebsite:
- youwillbethefirsttobeinformedofnewZodiacproductsandspecialoffers,
- Youcanhelpustoconstantlyimprovethequalityofourproducts.
AustraliaNewZealand www.zodiac.com.au
SouthAfrica www.zodiac.co.za
Europeandrestoftheworld www.zodiacpoolcare.com
Conformitycertificate
Z.P.C.E.declaresthattheherewithproductsorranges:
SwimmingpoolHeatpumps:ZodiacPower5M7M9M11M
areinconformitywiththeprovisions:
oftheELECTROMAGNETICCOMPATIBILITYdirective89/336/EEC.
oftheLOWVOLTAGEdirective73/23/EEC.
Foranywarrantyissues,pleasecontactyourlocalretailer.
Werecommendthatyoukeepyourpurchaseinvoicesafe,ifyourequireassistance
foryourproduct.
H0357903.A1.SAVer.11/20111
Electricdiagram
PW5M7M9MP1
English Powersupply230V1N50Hz
H0357903.A1.SAVer.11/20112
PW11M LNPE
English Powersupply230V1N50Hz
H0357903.A1.SAVer.11/20113
AFDigitaldisplay
Earth
C1Compressorcapacitor
C2Fancapacitor
C3Auxiliarypumpcapacitor
CDFlowratecontroler
E1Highpressureswitch
E2Lowpressureswitch
ED1Auxiliarypump
F1Fuse
KM1Compressorrelay
KM2Fanrelay
KM3Auxiliarypumprelay
KM4Complementaryrelay
M1Compressor
M2Fan
M3Auxiliarypump(150W200Wmaximum)
SD1Watertemperaturesensor
SD2Airtemperaturesensor
SD3Defrostsensor
T1Transformer
Dimensions
H0357903.A1.SAVer.11/20114
PWweight(Kg)
5M45
7M47
9M48
11M51
EnglishpoolwaterinletpoolwateroutletEvaporator
ZODIAC POOL CARE EUROPE / BP 90023, 49180 St Barthélémy d’Anjou cedex-France / S.A.S.U AU CAPITAL DE 517 200 E / SIREN 395 068 679 / RCS PARIS / Pour Qui Pourquoi / H03579-03.A
/