Crestron CEN-RFGWX-EX User manual

Category
Gateways/controllers
Type
User manual

This manual is also suitable for

Crestron CEN-RFGW-EX
infiNET EX™ Gateway
Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners.
©2009 Crestron Electronics, Inc.
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Contents
infiNET EX™ Gateway: CEN-RFGW-EX 1
Introduction ...............................................................................................................................1
Features and Functions................................................................................................ 2
Specifications ..............................................................................................................3
Physical Description....................................................................................................5
Industry Compliance ................................................................................................... 9
Setup ........................................................................................................................................11
Network Wiring.........................................................................................................11
Identity Code ............................................................................................................. 12
Installation................................................................................................................. 13
Hardware Hookup .....................................................................................................14
Programming Software............................................................................................................16
Earliest Version Software Requirements for the PC .................................................16
Programming with Crestron SystemBuilder.............................................................. 16
Programming with SIMPL Windows ........................................................................ 16
Example Program...................................................................................................... 19
Uploading and Upgrading........................................................................................................ 20
Establishing Communication.....................................................................................20
Programs and Firmware ............................................................................................21
Program Checks ........................................................................................................ 22
Operation .................................................................................................................................23
Problem Solving ......................................................................................................................25
Troubleshooting......................................................................................................... 25
Check Network Wiring..............................................................................................27
Reference Documents................................................................................................ 29
Further Inquiries ........................................................................................................29
Future Updates ..........................................................................................................29
Appendix A: The RF Spectrum ..............................................................................................30
Appendix B: Optimum RF Reception Guidelines .................................................................. 31
Minimize Interference ............................................................................................... 31
Gateway Placement ...................................................................................................31
Antenna Orientation ..................................................................................................32
Return and Warranty Policies .................................................................................................. 34
Merchandise Returns / Repair Service ......................................................................34
CRESTRON Limited Warranty.................................................................................34
Operations & Installation Guide – DOC. 6706A Contents i
Crestron CEN-RFGW-EX infiNET EX™ Gateway
infiNET EX™ Gateway:
CEN-RFGW-EX
Introduction
The CEN-RFGW-EX gateway is an RF wireless transceiver designed for
use with the MLX-2 infiNET EX™ LCD Handheld Remote and other
Crestron
®
infiNET EX devices as part of a Crestron control system.
“Wi-Fi friendly” RF technology permits selection from 16 ISM
*
channels
within the 2.4 GHz spectrum to minimize the possibility of interference
with other RF equipment including 802.11 devices. The CEN-RFGW-EX
affords a range of approximately 100 feet (30 meters) indoors.
Up to 16 MLX-2 remotes or other infiNET EX devices, may be
associated with a single CEN-RFGW-EX. Setup is simple, utilizing
dynamic discovery to locate and acquire each remote automatically. Each
wireless connection is monitored continuously, diligently keeping track
when remotes go to sleep or wander out of range and restoring
communications seamlessly when any remote reappears on the network.
More than just a wireless bridge, the CEN-RFGW-EX actually functions
as a proxy for each MLX-2, processing every button press and display
change right onboard. So when a remote goes to sleep or out of range, the
gateway continues communicating with the control system, keeping sync
with every command and updating the remote’s display the instant it
awakens or reconnects.
* Industrial, Scientific and Medical; refers to frequency range used for unlicensed
communications applications, such as Wi-Fi.
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 1
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
A choice of Cresnet
®
or PoE (Power-over-Ethernet) powers the
CEN-RFGW-EX right through the network wiring, eliminating the need
for a separate wall-wart power supply. The CEN-RFGW-EX is available
with a PoE Injector, PWE-4803RU included (as model
CEN-RFGW-EX-PWE), which simply connects inline with the Ethernet
cable connected to the gateway, allowing for installation at any
convenient location. Or, using Crestron’s 5-port PoE switch
(CEN-SW-POE-5, sold separately), up to four gateways and other PoE
devices can be powered from a single location, simplifying design and
wiring.
Features and Functions
infiNET EX 2-way RF wireless transceiver/gateway
Manages up to 16 MLX-2 handheld remotes or other Crestron
infiNET EX devices
Up to 100 feet (30 meters) range indoors
Dynamic discovery for fast, easy setup
“Wi-Fi friendly” channel selection
Built-in RF network diagnostics
Cresnet or Ethernet control system interface
PoE “Power-over-Ethernet” compatible
2 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Specifications
Specifications for the CEN-RFGW-EX are listed in the following table.
CEN-RFGW-EX Specifications
SPECIFICATION DETAILS
Wireless
RF Transceiver infiNET EX 2-way RF, 2.4 GHz
ISM Channels 11-26 (2400 to
2483.5 MHz), IEEE 802.15.4
compliant;
Maximum 16 remotes per
gateway;
Default RF channel is 15
Range (typical) 100 feet (30 meters) indoors,
subject to site-specific conditions
Ethernet 10BASE-T/100BASE-TX,
auto-switching, auto-negotiating,
auto-discovery, full/half duplex,
TCP/IP, UDP/IP, CIP, DHCP,
IEEE 802.3U and 802.3af
compliant;
Unit ships with DHCP enabled.
Power Requirements
1
PoE <45 mA @ 48 Volts DC
Cresnet Power Usage 2 Watts
(0.09 Amps @ 24 Volts DC)
Default Net ID 2F
Minimum 2-Series Control
System Update File
2, 3
Version 3.155.1240 or later
Environmental
Temperature 41º to 104º F (5º to 40º C)
Humidity 10% to 90% RH (non-
condensing)
Heat Dissipation 7 BTU/Hr
(Continued on following page)
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 3
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
CEN-RFGW-EX Specifications (Continued)
SPECIFICATION DETAILS
Enclosure Aluminum with polycarbonate
label overlay, freestanding or
surface mount with (4) integral
mounting flanges.
Dimensions
(without antenna)
Height 6.41 in (16.27 cm)
Width 3.91 in (9.94 cm)
Depth 1.43 in (3.62 cm)
Weight 13.1 oz (372.7 g)
Available Models
CEN-RFGW-EX infiNET EX Gateway
CEN-RFGW-EX-PWE infiNET EX Gateway
w/PoE Injector
Available Accessories
PWE-4803RU PoE Injector (included with model
CEN-RFGW-EX-PWE)
CEN-SW-POE-5 5-Port PoE Switch
1. May be powered by PoE or Cresnet network power.
2. The latest software versions can be obtained from the Crestron website. Refer to
the NOTE following these footnotes.
3. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest
Crestron Product Catalog for a complete list of 2-Series control systems.
NOTE: Crestron software and any files on the website are for authorized
Crestron dealers and Crestron Authorized Independent Programmers
(CAIP) only. New users may be required to register to obtain access to
certain areas of the site (including the FTP site).
4 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Physical Description
This section provides information on the connections, controls and
indicators available on your CEN-RFGW-EX.
CEN-RFGW-EX Physical View
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 5
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
CEN-RFGW-EX Overall Dimensions (Top, Front, Side and Bottom Views)
1
6.41 in
(16.27 cm)
1.43 in
(3.62 cm)
6
5
4
2
1
5.30 in
(13.47 cm)
3.50 in
(8.89 cm)
3
7
8
3.91 in
(9.94 cm)
6 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Connectors, Controls & Indicators
# CONNECTORS
1
,
CONTROLS &
INDICATORS
DESCRIPTION
1 ANTENNA (1) Connection for supplied
antenna
2 PWR LED (1) Green LED, indicates
operating power supplied from
Cresnet network or PoE
3 NET LED (1) Yellow LED, indicates
communication with the
Cresnet system
4 ACTIVITY LED (1) Red LED, indicates
wireless communications
5 ACQUIRE
(Button and LED)
(1) Recessed pushbutton with
red LED, used to set up
connections with wireless
devices
6 SETUP
(Button and LED)
(1) Recessed pushbutton with
red LED, used to set up
connection with the control
system via Cresnet or Ethernet
7 LAN PoE
2, 3, 4
GREEN
LED
YELLOW
LED
PIN 8
PIN 1
(1) 8-wire RJ-45 with two LED
indicators;
10BASE-T/100BASE-TX
Ethernet port, 802.3af Power
over Ethernet compliant;
Green LED indicates link
status;
Yellow LED indicates Ethernet
activity
PIN SIGNAL PIN SIGNAL
1 TX + 5 N/C
2 TX - 6 RC -
3 RC+ 7 N/C
4 N/C 8 N/C
(Continued on following page)
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 7
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Connectors, Controls & Indicators (Continued)
# CONNECTORS
1
,
CONTROLS &
INDICATORS
DESCRIPTION
8 NET
3
GZ Y
24
(1) 3.5 mm detachable terminal
block;
Cresnet slave port, connects to
Cresnet control network
24: Power (24 Volts DC)
Y: Data
Z: Data
G: Ground
1. Interface connector for NET port is provided with the unit.
2. To determine which is pin 1 on the cable, hold the cable so that the end of the
eight pin modular jack is facing away from you, with the clip down and copper
side up. Pin 1 is on the far left.
3. Power should be supplied through either the LAN PoE port or the NET port but
not both.
4. The pin out table indicates signal connections. DC power applied by Ethernet
power sourcing equipment (PSE) can connect to either signal pins or N/C pins.
8 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Industry Compliance
As of the date of manufacture, the CEN-RFGW-EX has been tested and
found to comply with specifications for CE marking and standards per
EMC and Radiocommunications Compliance Labelling.
Federal Communications Commission (FCC) Compliance Statement
FCC ID: EROCEN-RFGW-EX
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the
manufacturer responsible for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 9
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Industry Canada (IC) Compliance Statement
IC: 5683C-CENRFGWEX
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference
that may cause undesired operation of the device.
10 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Setup
Network Wiring
When wiring the Cresnet and Ethernet network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results
or damage to the equipment. Please use the Crestron Power
Calculator to help calculate how much power is needed for the
system (www.crestron.com/calculators
).
Cresnet
For networks with 20 or more devices, use a Cresnet Hub/Repeater
(CNXHUB) to maintain signal quality.
For more details, refer to “Check Network Wiring” which starts on page
27.
Ethernet
The CEN-RFGW-EX can also use high-speed Ethernet for
communications between the device and a control system, computer,
digital media server and other IP-based devices.
For information on connecting Ethernet devices in a Crestron system,
refer to the latest version of the Crestron e-Control
Reference Guide
(Doc. 6052), which is available for download from the Crestron website
(www.crestron.com/manuals
).
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 11
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Identity Code
Net ID
The Net ID of the CEN-RFGW-EX has been factory set to 2F. The Net
IDs of multiple CEN-RFGW-EX devices in the same system must be
unique. Net IDs are changed from a personal computer (PC) via Crestron
Toolbox™ (refer to “Establishing Communication” which starts on page
20).
When setting the Net ID, consider the following:
The Net ID of each unit must match an ID code specified in the
SIMPL™ Windows
®
program.
Each network device must have a unique Net ID.
For more details, refer to the Crestron Toolbox help file.
IP ID
The IP ID is set within the CEN-RFGW-EX’s table using Crestron
Toolbox. For information on setting an IP table, refer to the Crestron
Toolbox help file. The IP IDs of multiple CEN-RFGW-EX devices in the
same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the
SIMPL™ Windows
®
program.
Each device using IP to communicate with a control system must
have a unique IP ID.
12 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
Installation
Ventilation
To prevent overheating, do not operate this product in an area that
exceeds the environmental temperature range listed in the table of
specifications. Consider using forced air ventilation and/or incrementing
the spacing between units to reduce overheating. Consideration must be
given if installed in a closed or multi-unit rack assembly since the
operating ambient temperature of the environment may be greater than
the room ambient temperature. Contact with thermal insulating materials
should be avoided on all sides of the unit.
Placement
Tips
When installing a CEN-RFGW-EX near another CEN-RFGW-EX, for
optimum performance, keep the following in mind:
Do not place multiple gateways on the same channel. Refer to
“Appendix A: The RF Spectrum” on page 30 for details.
Gateways on adjacent channels should be at least 12 feet
(3.7 meters) apart.
Gateways on non-adjacent channels should be at least three feet
(0.9 meters) apart.
When installing a CEN-RFGW-EX near a Wi-Fi access point, for
optimum performance, keep the following in mind:
Gateways on RF channels adjacent to operating Wi-Fi channels
should be placed at least 12 feet (3.7 meters) from the nearest
Wi-Fi access point.
Gateways on RF channels that are non-adjacent to Wi-Fi channels
should be located at least six feet (1.8 meters) from the nearest Wi-
Fi access point.
For more information on RF channels and their interaction with the
Wi-Fi spectrum, refer to “Appendix A: The RF Spectrum” on page 30.
For additional information on optimal gateway placement, refer to
“Appendix B: Optimum RF Reception Guidelines” which starts on page
31.
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 13
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Hardware Hookup
Make the necessary connections as called out in the illustrations that
follow this paragraph. Refer to “Network Wiring” on page 11 before
attaching the 4-position terminal block connector. Apply power after all
connections have been made.
NOTE: Power should be supplied through either the LAN PoE port or
the NET port but not both.
When making connections to the CEN-RFGW-EX, use Crestron power
supplies for Crestron equipment.
Hardware Connections for the CEN-RFGW-EX (Top View)
ANTENNA:
FOR INCLUDED
ANTENNA
Hardware Connections for the CEN-RFGW-EX (Bottom View)
LAN PoE:
10BASE-T /
100BASE-TX
ETHERNET TO LAN
NET:
TO CONTROL SYSTEM
AND OTHER CRESNET
DEVICES
14 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
Crestron CEN-RFGW-EX infiNET EX™ Gateway
NOTE: Antenna must be attached directly to the antenna connector. It
should not be extended with a cable.
NOTE: Although both the LAN PoE and NET ports can be used for
configuration, there can only be one control connection to the control
system.
Operations & Installation Guide – DOC. 6706A infiNET EX™ Gateway: CEN-RFGW-EX 15
InfiNET EX™ Gateway Crestron CEN-RFGW-EX
Programming Software
Have a question or comment about Crestron software?
Answers to frequently asked questions (FAQs) can be viewed in the
Online Help section of the Crestron website. To post a question or view
questions you have submitted to Crestron’s True Blue Support, log in at
http://support.crestron.com
. First-time users will need to establish a user
account.
Earliest Version Software Requirements for the
PC
NOTE: Crestron recommends that you use the latest software to take
advantage of the most recently released features. The latest software is
available from the Crestron website.
Crestron has developed an assortment of Windows
-based software tools
to develop an infiNET system. For the minimum recommended software
versions, visit the Version Tracker page of the Crestron website
(www.crestron.com/versiontracker
).
Programming with Crestron SystemBuilder
Crestron SystemBuilder is the easiest method of programming but does
not offer as much flexibility as SIMPL Windows. For additional details,
download SystemBuilder from the Crestron website and examine the
extensive help file.
Programming with SIMPL Windows
NOTE: While SIMPL Windows can be used to program the
CEN-RFGW-EX, it is recommended to use SystemBuilder for
configuring a system.
SIMPL Windows is Crestron’s premier software for programming
Crestron control systems. It is organized into two separate but equally
important “Managers”.
16 infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Crestron CEN-RFGWX-EX User manual

Category
Gateways/controllers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI