ICP DAS USA GRP-530M User manual

Type
User manual
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
1
GRP-530M
GRP-540M Serial
3G / 4G Gateway
User Manual v1.14
High Quality, Industrial Data Acquisition, and Control Products
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
2
Warranty
All products manufactured by ICP DAS are warranted against
defective materials for a period of one year from the date of delivery to
the original purchaser.
Warning
ICP DAS assumes no liability for damages consequent to the use
of this product. ICP DAS reserves the right to change this manual at
any time without notice. The information furnished by ICP DAS is
believed to be accurate and reliable. However, no responsibility is
assumed by ICP DAS for its use, or for any infringements of patents or
other rights of third parties resulting from its use. This is licensed under
the terms of the GNU General Public License version 2.
Copyright
Copyright 2015 by ICP DAS CO., LTD. All rights reserved
worldwide.
Trademark
The names used for identification only may be registered
trademarks of their respective companies.
Version
Date
Author
Description
1.00
2015/11/05
Malo
Release version
1.11
2016/10/26
Malo
New feature: GPS Function
1.13
2016/11/21
Malo
Add 4G version (GRP-540M-4GE)
1.14
2017/01/11
Malo
Add DDNS Function
New feature: RTU-CAN Function
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
3
Table of Contents
1. Introduction ............................................................................................... 4
1.1 Features ............................................................................................................. 5
1.2 Applications ...................................................................................................... 5
2. Hardware ................................................................................................... 8
2.1 Specifications (GRP-530M) ............................................................................. 8
2.2 Specifications (GRP-540M Serial) ................................................................... 9
2.3 Appearance and pin assignments .................................................................... 11
2.4 Dimensions ..................................................................................................... 12
2.5 LED indicators ................................................................................................ 13
2.6 Installing Device ............................................................................................. 14
3. Web Utility .............................................................................................. 15
3.1 Login the Utility ............................................................................................. 15
3.2 Information ..................................................................................................... 16
3.3 Network .......................................................................................................... 19
3.4 System ............................................................................................................ 26
3.5 VxServer ......................................................................................................... 29
3.6 RTU Client ...................................................................................................... 31
3.7 RTU CAN Client ............................................................................................ 38
4. Example ................................................................................................... 42
4.1 3G/4G Router Application .............................................................................. 42
4.2 Web Server and IP Camera Application ......................................................... 45
4.3 Remote I/O Control / Temperature Monitor ................................................... 49
4.4 Modbus/TCP to Modbus/RTU over 3G, and Card Reader Monitor ............... 55
4.5 RTU Client for Remote Control Application with RTU API.......................... 62
4.6 RTU Client for Remote Control Application with OPC DA Server. .............. 74
4.7 RTU Client for Remote Control Application with InduSoft........................... 77
4.8 Email or FTP report I/O logger file. ............................................................... 79
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
4
1. Introduction
The GRP-530M / GRP-540M provided by ICP DAS is a 3G/4G gateway for Ethernet or
serial port. With GPS function, it can also be a GPS tracking system. It can be used in M2M
application fields to transfer the remote I/O, Modbus data or video of the camera via 3G/4G.
Within the high performance CPU, the it can handle a large of data and are suit for the hard
industrial environment. The GRP-530M / GRP-540M have 3G/4G module, Ethernet interface,
CAN Bus, and GPS module.
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
5
1.1 Features
Support WCDMA 850/900/1900/2100 MHz and GSM 850 / 900 / 1800 / 1900 MHz.
(GRP-530M)
Support 4G/3G/2G (GRP-540M Serial)
10/100 Base-TX compatible Ethernet controller
COM port: COM1 (3-wire RS232), COM2 (3-wire RS232), COM3 (RS-485)
Support CAN
GPS : 32 channels with All-In-View tracking (option)
Support Micro SD card.
Provide 3G / 4G Router function.
Support port mapping (port forward) function.
Serial Port to 3G / 4G Gateway
High reliability in harsh environments
DIN-Rail mountable
1.2 Applications
3G / 4G Router
Home/Factory security
Remote Video Monitor
Energy Management
Temperature Monitoring
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
6
Application 1: 3G/4G Router
Application 2: Remote Video Monitor
Application 3: Remote Control (Serial Port to 3G/4G gateway)
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
7
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
8
2. Hardware
2.1 Specifications (GRP-530M)
Item
GRP-530M
System / Software
3G Gateway
Embedded service
System
CPU
RAM
Flash
EEPROM
Expansion Flash Memory
RTC(Real Time Clock)
64-bit Hardware Serial Number
Watchdog Timer
LED Indicator
Rotary Switch
GSM System
Frequency Band
GPRS connectivity
3G System
Frequency Band
Data Transmission
GPS System
Support Channels
Protocol Support
Comm. Interface
Ethernet
COM1
COM2
COM3
CAN
Mechanism
Casing
Dimensions(W x L x H)
Installation
Power
Protection
Frame Ground Protection
Required Supply Voltage
Power Consumption
Environment
Operation Temp.
Storage Temp.
Humidity
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
9
2.2 Specifications (GRP-540M Serial)
Item
GRP-540M-4GE
GRP-540M-4GA
GRP-540M-4GC
Software
Gateway Function
Ethernet and Serial port (RS-232 x1, RS-485 x1) to 3G/4G
Embedded service
Web Server, Router function
System
CPU
ARM CPU
EEPROM
16 KB (Data Retention: 40 years; 1,000,000 erase/write cycles)
Expansion Flash Memory
SD Card (Max. 32GB SDHC)
RTC(Real Time Clock)
Provide seconds, minutes, hours, day of week/month, month and year
64-bit Hardware Serial Number
Yes
Watchdog Timer
Yes
LED Indicator
4 LEDs (RUN/PWR, 4G, L1, L2)
Rotary Switch
Yes (0~9)
GSM System
Frequency Band
GSM : 850/900/1800/1900 MHz
GPRS connectivity
GPRS class 12/10; GPRS station class B
DATA GPRS
Downlink transfer: Max. 85.6 kbps; Uplink transfer: Max 42.8kbps
3G System
Frequency Band (MHz)
WCDMA
850/900/2100
WCDMA
850/1700/1900
WCDMA 900/2100
TD-SCDMA 1900/2100
Data Transmission
DC-HSPA+ Download: Max. 42 Mbps; Upload: Max 5.76Mbps
TD-SCDMA Download: Max. 4.2 Mbps; Upload: Max 2.2Mbps
4G System
Frequency Band
FDD LTE:
B1/B3/B5/B7/B8/B20
FDD LTE:
B2/B4/B5/B12/B17
FDD LTE: B1/B3/B8
TDD LTE:
B38/B39/B40/B41
Data Transmission
Download Max 100Mbps / Upload Max 50Mbps
GPS System
Support Channels
32
Protocol Support
NMEA 0183
Comm. Interface
Ethernet
RJ-45, 10/100 Base-TX
(Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM1
RS-232 (RxD, TxD and GND); Non-isolated(Console, Debug)
COM2
RS-232 (RxD, TxD and GND); Non-isolated
COM3
RS-485 (D2+, D2-); 3000 VDC isolated
CAN
CAN Bus (CAN_H, CAN_L)
Mechanism
Casing
Metal
Dimensions(W x L x H)
117 mm x 126 mm x 58 mm (W x L x H)
Installation
DIN-Rail / Screw
Power
Protection
Power reverse polarity protection
Frame Ground Protection
ESD, Surge, EFT, Hi-Pot
Required Supply Voltage
+10 V
DC
~ +48 V
DC
Power Consumption
4.8W ( 200 mA @ 24 V
DC
)
Environment
Operation Temp.
-25 to 75
Storage Temp.
-30 to 80
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
10
Humidity
5~95% non-condensing
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
11
2.3 Appearance and pin assignments
COM Port & Power Iput
Terminal No.
Pin Assignmnt
Power
01
F.G.
02
P.GND
03
PWR
COM1
04
TxD1
05
RxD
06
GND
COM2
07
TxD2
08
RxD2
09
GND
COM3
10
D+
11
D-
CAN
12
CAN.GND
13
CAN_H
14
CAN_L
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
12
2.4 Dimensions
Unit: mm
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
13
2.5 LED indicators
There are three LED indicators to help users to judge the various conditions of device. The
description is as follows
A. PWR(Green)Power LED to indicate whether the external power is input or not. The
description is as follows:
The external power is active
The external power is not active
on
off
B. RUN(Red)RUN LED indicates if the OS is normal or fail.
Normal
Fail
Heart beat (1 sec.)
Always ON or OFF
C. L1(Green/Red)this Led indicates the status of RTU Client.
Normal
Fail
500ms ON / 500ms OFF
Always ON or OFF
D. L2(Green/Red)reserve.
E. 3G (Red)The LED indicates the status of 3G module.
(the 3G/4G module need about 60 seconds to register network usually)
Registered
3G/GPRS data transmit
Not Register
800ms ON / 200ms OFF
200ms ON, 200ms OFF
200ms ON / 800ms OFF
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
14
2.6 Installing Device
Before using, please follow these steps to install the device below:
A. Install the antenna
B. Plug in the normal SIM card (Before apply the SIM card, confirm it is OK by mobile
phone.)
C. Plug the Ethernet cable if you need it.
D. If you want to use the Micro SD card, please insert it into the slot.
E. Connect the DC.+VS and DC.GND to the power supply.
F. It is needed to wait about 20 ~ 30 seconds for OS booting. After finishing the process, the
device would be in normal operation mode and the OS LED would blank as heart beat
per 1 sec.
G. It is needed to wait about 30 ~ 60 seconds to search the 3G/4G base station and register
to the ISP. After finishing the process, the 3G LED would blank per 1 sec.
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
15
3. Web Utility
You must configure the device from web utility before using.
3.1 Login the Utility
Please login before you use the web utility. The default username is admin, and the
default password is admin
Default IP = 192.168.255.1
Default Mask = 255.255.0.0
After login, the screenshot is showed as below:
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
16
3.2 Information
You can get the basic information of the device here.
3.2.1 Device Information
This page provides basic device information:
(1) Product Name: the Name of your product
(2) Serial Number: only one number of ICPDAS product
(3) OS Kernel Version: linux kernel version.
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
17
3.2.2 Network Information
This page provides basic network information:
(1) Ethernet: Ethernet information
Mode: static IP
MAC address: a unique identifier assigned to network interfaces.
IP Address: a computer's address under the Internet Protocol
Mask: Mask will be provided from Gateway provider.
(2) Mobile Network information: the information will show out after dial up
Status: connected mean the modem dial-up success.
IP Address: the IP is provide by ISP provider.
P-t-P: provide by ISP provider
(3) Modem information:
IMEI: IMEI number of 4G module.
PIN Code: the status of PIN Code. Please refer to below:
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
18
READY: PIN Code is ready.
SIM PIN: need PIN code of SIM card
SIM PUK: need PUK code of SIM card
SIM failure: Access SIM Card failure
Register Status: Indicating machine connect to mobile network successful or not.
Signal Quality: the 3G/4G signal quality.
3.2.3 Storage Information
This page provides information about Micro SD card, USB Disk:
(1) USB Disk / SD card:
Size: total size of storage
used: the size is used
Available: free space in the storage
Path: the mount point in file system.
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
19
3.3 Network
The user can configure the Network functions here.
3.3.1 Ethernet
This page provides the basic settings of Ethernet:
(1) IP Address: IP of Ethernet.
(2) Mask: the Mask of the gateway.
(3) Gateway: IP of the gateway.
3.3.2 PIN / APN Configure
This page provides basic settings of 3G network:
(1) PIN Code: PIN Code are 4 character number provided by SIM Card provider
(2) Phone Number: usually fill it as *99***1# or *99#. The number is depended on
SIM Card provider
(3) APN: Access Point Name, please ask your SIM Card provider.
(4) User Name: the username for dial-up. Please ask your SIM Card provider.
(5) Password: the password for dial-up. Please ask your SIM Card provider.
3.3.3 Network Reconnection
This function can keep the device always on mobile network, but it will send the
GRP-530M / GRP-540M User Manual, V1.14, Jan. 2017
20
IMCP signals to check mobile network.
The default setting is Enable to keep device always online.
(1) Server IP: the target IP or URL that you want to send signal (ping the target IP).
(2) Max. Retry: if the system retry time is over this number, it will reset 3G/4G modem
and dial-up to try again.
(3) Interval Time: the interval time between this retry and last.
(4) Enable Function: if you enable this function, it will run immediately.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81

ICP DAS USA GRP-530M User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI