QuickStartfor
CANLogger series
Dec 2015, Version 1.0.2
Congratulations on purchasing CANLogger series‐the most popular automation
solutionforCANBusdatalogging.ThisQuickStartwillprovideinformationneeded
to get started with CANLogger series. Please also consult the User Manual for
detailedinformationonthesetupanduseofCANLoggerseries.
CANLoggerseriesQuickStart
Inadditiontothisguide,thepackageincludesthefollowingitems:
1
CANLogger100or
CANLogger200
SoftwareUtilityCD
USBcable
(CAUSB15)
ScrewDriver
(1C016)
microSD
(3LMSD40001)
M12A5PIP68connector
(4PIO1K0000003)
Core
(4SIO1K0000014)
y CANLoggerseriesUserManual
CD:\fieldbus_cd\can\canlogger\manual\
ftp://ftp.icpdas.com/pub/cd/fieldbus_cd/can/canlogger/manual/
y CANLoggerseriesWebsite
http://www.icpdas.com/root/product/solutions/industrial_communication/fieldbus/can_bu
s/specific_device/canlogger.html
y ICPDASWebsite
http://www.icpdas.com/
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
1
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
HardwareInstallation
BeforeusingCANLoggerdevice,somethingsmustbedone.
Step1:PrepareoneCANLoggerdevice
Step2:SettheCANbaudrateofCANLoggerdevicebyusingrotary
switch
CANLoggerseriesQuickStart
SwitchValueMeaning
0 Setbaudrateto10kbps
1 Setbaudrateto20kbps
2 Setbaudrateto50kbps
3 Setbaudrateto100kbps
4 Setbaudrateto125kbps
5 Setbaudrateto250kbps
6 Setbaudrateto500kbps
7 Setbaudrateto800kbps
8 Setbaudrateto1Mbps
9
Setbaudratetouserdefinedbaudratewhichisconfiguredby
CANLoggerutility.
A~E N/A
F
SetCANLoggerdeviceintofirmwareupdatemode.Thefirmware
updatetoolisneeded.
2
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
Step3:Determineiftheterminatorresistorisneededornot
Checktheapplicationstructure,anddetermineiftheterminatorresistorisneededornot.You
canfinditatthepositionasfollows.
CANLoggerseriesQuickStart
3

Generally,ifyourapplicationisasfollows,werecommendyoutoenabletheterminatorresistor.
Ifyourapplicationislikethestructureasfollows,theterminatorresistorisnotneeded.
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
Step4:ConnecttheCANport,powerline,framegroundorUSBportof
theCANLoggerdevice.
Thepinassignmentandwireconnectionareasfollows.Whenfinished,runyourapplicationwith
theCANLoggerdevice.
CANLoggerseriesQuickStart
Pin.No. Name Meaning
1 F.G. FrameGround.
2 +Vs VoltageSourceInput.+10VDC~ +30VDC.
3 GND PowerGround.
4 CAN_H CAN_High,signallineofCANport.
5 CAN_L CAN_Low,signallineofCANport.

4
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
2
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Utilitytool
WhenuserswanttouseuserdefinedCANbaudrate,CANmessag efilteranddiagnosticfunctiononthe
CANLoggerseries,theCANLoggerUtilitytoolmaybeneeded.
Step1:InstalltheCANLoggerUtility
Thesoftwareislocatedat:
Fieldbus_CD:\CAN\Converter\CANLogger\Software\Utility
http://www.icpdas.com/products/Remote_IO/can_bus/canlogger.htm
CANLoggerseriesQuickStart
Step2:SettinguptheCANLoggermodule
1. ConnectthePCavailableUSBportwiththeUSBportoftheCANLoggerdevice.Userscan
findthecommunicationcable(CAUSB15)intheproductbox.
2. ExecutetheCANLoggerUtilitytool.
5
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
Step3:ConfiguretheCANLoggerseries
WhenexecutingtheUtility,thetoolwilltrytoscanallthenecessaryCANLoggermodulesand
listallscannedmoduleinformationontheleftbottomoftheUtilitymainframe.Usercanpress
the“Refresh”buttomtorescanthenewerinsertedCANLoggermodule.
CANLoggerseriesQuickStart
ViatheCANLoggerUtility, usercansettheCANportoperationmodeandfilterparameterof
themodule.Pleaseref ertothefollowingstepstoconfiguretheCANLoggerseries.
1. SelectthenecessaryCANLoggermoduleandthenpressthe“Configurate”buttom.
Thenthe“DeviceConfiguration”windowwillbepoppedup.
6
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
CANLogger seriesQuickStart
7
2. Onthe“DeviceConfiguration”windows,usercansettheCANBusparameter,andother
prarameters.Thedetailfunctionsoftheseparametersarelistbelow.
[CANBusParameters]
“PortEnable” : Enable/DisabletheCAN1/CAN2port.
“SilentMode”: SettheCANportintosilentmode.WhensettingtheCANportintosilent
mode,theCANportwilljustreceiveCANmessages,noCANAckcommand
besenttotheCANBus.
“BaudRate”:CANBusbaudrateinused.Viasettingtherataryswitchfrom‘0’~‘8’,usercan
changetheCANBusbaudratefrom‘10kbps’to‘1Mbps’.Ifyouwanttouse
userdefinedCANbaudrate,usercansettherataryswitchto‘9’,andthensetthe
“DefinedBaudRate”parametertotheCANbaudratethatyouneed.
“DefinedBaudRate”: CANBusbaudrateusedforuserdefined.AftersettheCANrotaryswitch
to‘9’,youcansetthisparametertothebaudrateyouneed.
“SamplePoint”: SamplepointofCANbaudratebittiming.
“CANIDFilter”: CANmessageIDfilter.
[Mode]: ModeofCANID,canbesetto2.0A(11bitCANID)and2.0B(29bitCANID).
[Mask]: MaskCANIDbits.Beusewith[Arbitration]parameter.Bitvalueof0meandoes
notcarethebitofcorrespondingArbitrationCANID”andbitvalueof1means
thisbitneedbematchedwiththecorrespondingbitofArbitrationCANID”.
[Arbitration]: ArbitrationCANIDbit.TheCANIDthatyouwanttousefortheCANIDfilter.
[Example]
1. AllCANIDpassed.
[Mode]=“2.0A
[Mask]=“000”
[Arbitration]=“000”
2. Filterallmessagesex ceptIDof0x123.
[Mode]=“2.0A
[Mask]=“7FF”
[Arbitration]=“123”
3. Filterallmessagesex ceptIDfrom0x100~0x10F.
[Mode]=“2.0A
[Mask]=“7F0”
[Arbitration]=“100”
[OtherParameters]
“DeviceRealtimeclock”: RTCtimeoftheCANLoggerdevice.Thisparameterisusedfor
CANLoggerdevicetologthereceivedCANmessagesintoSDcard.
“RTCBatteryVoltage: CrrentbatteryvoltagethatRTCused.Thebatteryvaltagemustbe
thevaluebetween2.2V
DC
to3.6V
DC
.
Copyright © 2015 ICP DAS Co., Ltd. All Rights Reserved. E  -mail: [email protected]
Step4:Transmit,receiveCANmessagesandcheckCANBusstate
ByusingtheCANLoggerUtiltiytool,usercantransmit,receiveCANmessagesandchecktheCAN
BusstateoftheCANLoggerdevices.
1. ConnectwiththeselectedCANLoggerdevice.
2. TransmitCANmessages,checkreceivedCANmessagesandCANBusstate.
CANLoggerseriesQuickStart
3
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Core’sapplicationandwiring
Core(Ferrite)isusefultoreduce
ElectroMagnetic
Interference(EMI)andantinoise,itmainlyusesfor
communicationinterfacelikeCANBusandDCpowersupplyline.
8
ThebelowphotosarethewiringofthecoreonCANBusside.