6) Slip canopy over screw collar loop and thread on threaded
ring. Aach chain[I] (open one link[H]) to boom of
screw collar loop. Unscrew threaded ring, let canopy and
threaded ring slip down.
7) Adjust chain to desired length by removing chain links and
aach chain to large loop[J] on top of main body of xture
with one open link[H], close the open links by wrapping
with a towel and squeezing closed using pliers.
8) Weave electrical wire and ground wire through chain[I]
no more than 3 inches apart. Pass wire through threaded
ring[F], canopy, screw collar loop, threaded pipe and into
outlet box.
9) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
11) Raise canopy to ceiling.
12) Secure canopy in place by ghtening threaded ring onto
screw collar loop.
13) Take the four side arms[L] and with the studded ball
knobs[M] aach the arm to the top of the main body of
the xture[K] as shown.
14) Take the lower bracket[N] and place the lower part of
the side arms into the bracket and secure into place with
the four (4) supplied screws[P] as shown.
15) Install the recommended bulbs (not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
1) Take threaded pipe[A] from parts bag and screw in screw
collar loop[B] a minimum of 6 mm (1/4”). Lock into place
with hexnut[C].
2) Run another hexnut down threaded pipe almost touching
rst hexnut. Now screw threaded pipe into mounng
strap[D]. Mounng strap must be posioned with
extruded thread faced into outlet box[E]. Threaded pipe
must protrude out the back of mounng strap. Screw
third hexnut onto end of threaded pipe protruding from
back of mounng strap.
3) Connect mounng strap[D] to outlet box using the strap
mounng screws[O].
4) Unscrew the threaded ring[F] from screw collar loop. Take
canopy[G] and pass over screw collar loop. Approximately
one half of the screw collar loop exterior threads should
be exposed. Adjust screw collar loop by turning assembly
up or down in mounng strap. Remove canopy.
5) Aer desired posion is found, ghten both top and
boom hexnuts up against the boom and top of the
mounng strap.
Installaon Instrucons (connued)
E
D
C
O
A
G
B
F
H
I
H
J
K
L
M
N
P
[A] Threaded
Pipe
[B] Screw Collar
Loop
[C] Hexnut
[D] Mounting
Strap
[E] Outlet Box
[F] Threaded
Ring
[G] Canopy
[H] Chain Link
[I] Chain
[J] Large Loop
[K] Main Body of
Fixture
[L] Side Arms
[M] Studded Ball
Knobs
[N] Lower
Bracket
[O] Strap
Mounting
Screws
[P] Screws
IS-43034-CB
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
6) Slip canopy over screw collar loop and thread on threaded
ring. Aach chain[I] (open one link[H]) to boom of
screw collar loop. Unscrew threaded ring, let canopy and
threaded ring slip down.
7) Adjust chain to desired length by removing chain links and
aach chain to large loop[J] on top of main body of xture
with one open link[H], close the open links by wrapping
with a towel and squeezing closed using pliers.
8) Weave electrical wire and ground wire through chain[I]
no more than 3 inches apart. Pass wire through threaded
ring[F], canopy, screw collar loop, threaded pipe and into
outlet box.
9) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
11) Raise canopy to ceiling.
12) Secure canopy in place by ghtening threaded ring onto
screw collar loop.
13) Take the four side arms[L] and with the studded ball
knobs[M] aach the arm to the top of the main body of
the xture[K] as shown.
14) Take the lower bracket[N] and place the lower part of
the side arms into the bracket and secure into place with
the four (4) supplied screws[P] as shown.
15) Install the recommended bulbs (not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
1) Take threaded pipe[A] from parts bag and screw in screw
collar loop[B] a minimum of 6 mm (1/4”). Lock into place
with hexnut[C].
2) Run another hexnut down threaded pipe almost touching
rst hexnut. Now screw threaded pipe into mounng
strap[D]. Mounng strap must be posioned with
extruded thread faced into outlet box[E]. Threaded pipe
must protrude out the back of mounng strap. Screw
third hexnut onto end of threaded pipe protruding from
back of mounng strap.
3) Connect mounng strap[D] to outlet box using the strap
mounng screws[O].
4) Unscrew the threaded ring[F] from screw collar loop. Take
canopy[G] and pass over screw collar loop. Approximately
one half of the screw collar loop exterior threads should
be exposed. Adjust screw collar loop by turning assembly
up or down in mounng strap. Remove canopy.
5) Aer desired posion is found, ghten both top and
boom hexnuts up against the boom and top of the
mounng strap.
Installaon Instrucons (connued)
E
D
C
O
A
G
B
F
H
I
H
J
K
L
M
N
P
[A] Threaded
Pipe
[B] Screw Collar
Loop
[C] Hexnut
[D] Mounting
Strap
[E] Outlet Box
[F] Threaded
Ring
[G] Canopy
[H] Chain Link
[I] Chain
[J] Large Loop
[K] Main Body of
Fixture
[L] Side Arms
[M] Studded Ball
Knobs
[N] Lower
Bracket
[O] Strap
Mounting
Screws
[P] Screws
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 43034DAG User manual

Type
User manual

Ask a question and I''ll find the answer in the document