  • Hello! I am an AI chatbot trained to assist you with the servibell SB-HCM-3000N Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
!
Operating Manual
Wristwatch-type.Receiver................................... model: SB-HCM-3000N
(Model names may vary by country)
<Button Descriptions>
FUN (FUNCTION): To start function, To enter chosen function.
PWR (POWER): Power ON/OFF, To move on to next function, To move on to next number/menu
ESC (ESC): To delete the calling numbers one by one, To complete/exit function
<Basic Descriptions>
POWER ON: Press “PWR” button for 3 seconds to turn on the Wristwatch-type Receiver. When power is turned on, the
screen will show “333 222 111 000” with a short beeping sound and vibration. The backlight is shortly turned on and off.
Now the screen is on the stand-by status.
POWER OFF: Press “PWR” button for 3 seconds to turn it off.
CHARGING: GREEN: Plug in the adapter and the LED light on the adapter will turn on green.
RED: As the USB cable is connected to the Wristwatch-type Receiver, the LED light turns into red which
means the receiver is in the charging status.
GREEN: When the receiver is fully charged, the LED light turns into green.
* After fully charged, the battery will maintain approximately 40 hours on a stand-by status till the next charging.
BACKLIGHT: Backlight is on for 2 seconds and then goes off at the moment the Wristwatch-type Receiver gets the
signal or the Function buttons are performed.
BATTERY CHECK & BELL TEST: Press “ESC” button for 3 seconds on Stand by Mode, then “rF###” will appear.
###: Voltage indication
Push the buttons on Wireless Service Bell. It’s normal if rF blinks on display making a beeping sound. press “ESC” to
exit the function.
* Using this Bell Test Mode, you can test the Wireless Service Bells without registering them on receivers.
BATTERY ALARM: When the battery is low, melody will be played and the battery icon will blink.
RESET: The first thing you have to do is resetting SB-HCM-3000N before performing any function.
(Go to Function F6 (bdE))
* After the reset (“dEL”), everything turns into the basic settings. So you have to change them according to your needs.
<Main Features>
1. Dimensions: 42mm X 57mm X 15 mm
2. Frequency: 433.92MHz
3. Power: DC3.7V/180mA
4. Battery: Lithium Polymer (Internal)
5. Receive Sensitivity: -105dBm
6. Expected Battery Life: 40 hours standby
7. Internal Battery
8. Internal Antenna
9. Backlight LED Blue
10. 3 signals, 3-digit display
11. Multiple Bell registration with same number is possible.
12. The standard type of cable (Micro USB) is offered.
13. Priority Numbers: U00~U06
14. Cancel Numbers: U07, U08, U09
Basic Settings
F2 (bEL): 4
F3 (dSP): 5
F4 (bno): 1
Beep Sound: melody and vibration
Display Time: 5 SEC!
Beep Number: 1 TIME
!
<Functions>
F1 (rEC): Number Registration
F2 (bEL): Melody/Vibration Selection
F3 (dSP): Number Display Time
F4 (bno): To change number of times the melody or vibration repeats
F5 (HdE): To delete Registered Multi-Data Terminal
F6 (bdE): To delete Registered Numbers or reset
F9 (rSP): Recall Time Setting (to prevent multiple calling when using repeater)
1. F1 (rEC) Number Registration
A) Registering Wireless Service Bell
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “ENT” button, screen will display “000” and the last “0” blinks. You can use “FUN” button to move the
blinking digit. Press “PWR” button to change the numbers. When you choose the desired number, move on to Step 3.
Step 3. Press the Wireless Service Bell that you want to register. The wristwatch will make a beep sound and blink for 2
seconds to indicate the registration is completed.
Step 4. Use “FUN” and “PWR” buttons to go on to the next desired number and do Step 2 and 3 again.
Step 5. When you finish registration, press “ESCto exit the function.
Step 6. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
* Up to 2,399 Wireless Service Bells can be registered with SB-HCM-3000N.
001~999, A00~A99, b00~b99, C00~C99, d00~d99, E00~E99, F00~F99, H00~H99, L00~L99, n00~n99, o00~o99,
P00~P99, r00~r99, t00~t99, U00~U99 (U00~U06 have priority. Only waiting version)
* Cancel Bell Registration
U07, U08, U09: If you want to cancel the call showed up on the specific site (left, upper right or lower right) on
Wristwatch-type Receiver’s display, register U07, U08 and U09 with each Wireless Service Bell.
U07: When you push the NO. U07 Bell, the left number on the Receiver will be canceled.
U08: When you push the NO. U08 Bell, the upper right number on the Receiver will be canceled.
U09: When you push the NO. U09 Bell, the lower right number on the Receiver will be canceled.
* If you want to change the number of the Wireless Service Bell, just register the new number. There is no need of
deleting the previously registered number from the Receiver.
* Multiple bells can be registered with same number. (Up to 2,399)
B) Registering Multi-Data Terminal
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “ENT” button, screen will display “000” and the last “0” blinks. You can use “FUN” button to move the
blinking digit. Press “PWR” button to change the numbers. When you choose the desired number, move on to Step 3.
* You can register 5 Multi-Data Terminals to each receiver. So, in Step 2, registering number is limited from
001~005. (Each number should match to each Multi-Data Terminal.) However, the registering number for Multi-Data
Terminal is nothing to do with the numbers of Service Bells.
Step 3. Now press “REC” button on the Multi-Data Terminal and number “0” twice. Lastly, press “CALL” button.
(REC à 00 à CALL)
Step 4. The numbers both on the receiver and the Multi-Data Terminal will blink twice. Now the Multi-Data Terminal is
registered to the receiver.
2. F2 (bEL) Melody/Vibration Selection
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F2 (bEL)” is displayed.
Step 3. Press “ENT” button and then the current melody (and/or vibration, voice) will be played.
Step 4. Press “PWR” buttons to choose the desired melody (and/or vibration, voice) from 1 to 9. Exit the function with
ESC”.
1: melody number 1
2: melody number 2
3: melody number 3
4: melody and vibration
5: vibration
!
6: mute
7: voice and vibration
8: voice and melody
9: voice
Voice require earphones to be sold separately.
Volume function when setting voice(7~9) with button “FUN=UP” or “PWR=DOWN” uol 1~uol 10
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
3. F3 (dSP) Number Display Time
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F3 (dSP)” is displayed.
Step 3. Press “ENT” button and the screen will show the current display time number. (00, 05~15) Press “PWR
buttons to set the desired display time.
00: Infinite display time
05~15: The calling numbers will be displayed on the screen for 5~15 seconds.
Step 5. Exit the function with ESC”.
Step 6. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
4. F4 (bno) To change number of times the melody or vibration repeats
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F4 (bno)” is displayed.
Step 3. Press “ENT” button. The current number of melody repetition will be displayed.
Step 4. Change the status by using “PWR” button.
1: melody or vibration plays 1 time
2: melody or vibration repeats 2 times
3: melody or vibration repeats 3 times
4: melody or vibration repeats 4 times
5: melody or vibration repeats 5 times
Step 5. Exit the function with ESC”.
Step 6. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
5. F5 (HdE) To delete Registered Multi-Data Terminal
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F5 (HdE)” is displayed.
Step 3. Press “ENT” button. The number 1 will appear. There are five numbers, 1 to 5, for each registered Multi-Data
Terminal.
Step 4. If you want to delete and unregister a certain number of Multi-Data Terminal, press “FUN” for two seconds. The
beeping sound means that the number is unregistered. Skip the numbers by using “PWR” button. There are no “all
delete” function for Multi-Data Terminal.
Step 5. As the unregistration is completed, press “ESCbutton as you finish deleting.
Step 6. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
6. F6 (bdE) To delete Registered Numbers or reset
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F6 (bdE)” is displayed.
Step 3. Press “ENT” button and the screen will display the lowest registered number from Wireless Service Bells.
Step 4. Press ENTbutton to delete the number. When the number is deleted, the next one will appear. You can use
PWRbuttons to skip and not to delete the numbers.
If you want to delete all the registered numbers, press “FUN” for 3 seconds. Then “dEL” appears on the screen and after
5~15 seconds, the message turns into “OOO”. Now all the numbers are unregistered.
Step 5. As the unregistration is completed, press “ESCbutton as you finish deleting.
Step 6. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
!
7. F9 (rSP) Recall Time Setting (When using repeater)
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press “PWR” button until F9 (rSP)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR”
button(0~4).
0: All
1: After 0.5 seconds
2: After 1 second
3: After 1.5 seconds
4: After 2 seconds
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
Special Functions
1.E1 (Pdt) Product settings: Standard Version/Waiting Version
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR”
button(1~2).
1: Standard Version
(The calling number moves from left to right on display. For example, when 1, 2, and 3 calling number come in order,
they will appear on display as 3, 2, and 1.)
2: Waiting Version
(The calling number will be stacked up from left to right. For example, when 1, 2, and 3 calling number come in order,
they will appear on display as 1, 2, and 3. If the more calling numbers continue to come, they will be saved up to ten.
As the display shows 1, 2, and 3, seven more callings (4 to 10) can be saved and showed up later.)
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
2. E2 (rF) Receive Settings: Service Bell input code
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until E2 (rF)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR” button(8, F,
C).
8: Products in 2014
F: Products before 2014
C: Special-purpose Service Bell
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
3. E3 (Cb) Calling display: to select whether the English displays or not
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until “E3 (Cb)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR” button(nor,
CAL).
nor: Show only numbers
CAL: CAL, and BIL are displayed in numbers and alphabets.
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
!
4. E4 (bit) Product type: Select Transmitter
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until “E4 (bit)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR” button(oLd,
nE).
oLd: 20bit
nE: 32bit (When the bell is changed, the existing bell registration value is automatically initialized.)
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
!
5. E5 (CoP) Memory duplication: Copy cable
* Before duplicating the memory of one Wristwatch-type Receiver(A) to another(B), prepare the Copy Cable.
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until “E5 (CoP)” is displayed. Press “FUN” button and the screen will show the current
number.
Step 4. Change the status by using “PWR” button “td”
td: Sending device
rd: Receiving device
Step 5. Now take the Wristwatch-type Receiver(B) whose memory is to be replaced by the memory of the Receiver(A)
and do Steps 1 and 3.
Step 6. Press “PWR” of the Receiver(B) to choose rd.
Step 7. Connect the Receiver (A) and (B) with the Copy Cable, and press “FUN on the Receiver(A). The status is
normal if “rd” on the Receiver(B) blinks while transmitting. When it’s completed(100%), the Receiver(B) goes to the
stand-by mode.
Step 8. Repeat steps 5 to 7 to continue copying multiple copies.
Step 9. When you finish, press “ESC” to exit the function.
Step 10. Now disconnect the Copy Cable from the Receivers (A) and (B).
* Copy cable require earphones to be sold separately.
6. E7 (AP) Wireless ID setting: Set up signal reception of repeater
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until E7 (AP)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR”
button(AP0~AP9).
AP0: Receives AP0 ~ AP9 signal of repeater
AP1~AP9: Receives the repeater signal selected when AP1 ~ AP9 is selected
(If AP5 is set in the receiver, it receives only the AP5 signal of the repeater, and AP0,1,2,3,4,6,7,8,9 of the repeater is
not received.)
Step 4. Press “ESC” button to exit the function.
Step 5. If you want to select the other function, use “PWR”. Or if you want to go back to the stand-by status, press
“ESC”.
7. E8 (grP) Multi Terminal Group Registration: Multi-terminal ID number registration
Step 1. Press and hold “FUN” button for 3 seconds. F1 (rEC) displayed.
Step 2. Press and hold “FUN” button for 3 seconds. E1 (Pdt) displayed.
Step 3. Press “PWR” button until E8 (grP)” is displayed.
Step 3. Press “ENT” button and the screen will show the current number. Change the status by using “PWR” button(ID
and no).
*Choose ID, and five Multi-terminals (01 to 05) can be registered.
*Choose no, and you can register 10 Wristwatch-type Receivers to one Multi-terminal. The Multi-terminal will be able to
call each Wristwatch-type receiver separately from 1 to 10.
/