Dell EMC PowerStore Release Notes
Dell EMC PowerStore
Release Notes
Release Version: 1.0.0.0.5.109
Release Type: Major (MA)
May, 2020
2 Dell EMC PowerStore Release Notes
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with
respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for
a particular purpose.
Use, copying, and distribution of any software described in this publication requires an applicable software license.
Copyright © 2020 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are
trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
Contents
3 Dell EMC PowerStore Release Notes
Contents
Product Description ............................................................................................................................................................. 4
PowerStore deployment models .................................................................................................................................. 5
Known Issues ...................................................................................................................................................................... 6
Limitations ......................................................................................................................................................................... 16
PowerStore T and PowerStore X model limitations ................................................................................................... 16
PowerStore X model limitations ................................................................................................................................. 17
Installation and Upgrade Considerations .......................................................................................................................... 17
Environment and System Requirements .......................................................................................................................... 17
Support Matrix ............................................................................................................................................................ 17
Where to Get Help ............................................................................................................................................................ 17
Product Description
4 Dell EMC PowerStore Release Notes
Product Description
The ground-breaking Dell EMC PowerStore achieves new levels of operational simplicity and agility, utilizing a container-
based architecture, advanced storage technologies, and intelligent automation to unlock the power of your data. Based
on a scale-out architecture and hardware-accelerated advanced data reduction, PowerStore is designed to deliver
enhanced resource utilization and performance that keeps pace with application and system growth. Utilizing the proven
capabilities of VMware ESXi, PowerStore X models with AppsON provide the unique ability to host data-intensive and
storage applications directly on the PowerStore system with a storage-based virtualization environment, with the flexibility
of seamless movement of applications between the storage system and external VMware servers. PowerStore T models
provide organizations with all the benefits of an enterprise unified storage platform for block, file and vVol data, while
enabling flexible growth with the intelligent scale-up AND scale-out capability of appliance clusters. Highlighted features
include:
Brand new built from scratch all NMve Platform:
o All NVMe
o Active-Active architecture
o Container based PowerStoreOS
o Block, File, and vVols
o NVMe Flash and Storage Class Memory (SCM) media support
o 25 Gbe iSCSI and 32Gb FC support
o Compact 2U starting form factorEnterprise Data Services & Leading Data Reduction:
o Inline dedupe and compression
o Native async replication
o Snapshots and space efficient thin clones
Enterprise Data Services & Data Reduction:
o Inline dedupe and compression
o Native async replication
o Snapshots and space efficient thin clones
o Advanced drive failure protection and sparing technology
Simple and intelligent Management & Serviceability:
o Embedded management
o Built in AI for simple, autonomous storage administration and proactive health analytics
o CloudIQ
o VM Visibility
o New Anytime Upgrade Program
o Integration with automation framework
Flexible & Granular Scalability:
o Scale Up in single drive increments, up to 2.8 PBe per appliance
o Scale Out to 4 appliances, up to 11.3 PBe per cluster
o Scale Down
VMware:
o VMware vVols 2.0/VASA 3.0 support
o New AppsOn hypervisor-based deployment, allowing to run Virtual Machines on the same appliance as
storage without the need for an external server
Product Description
5 Dell EMC PowerStore Release Notes
PowerStore deployment models
Table 1 PoweStore deployment models and configurations
Deployment
Model
Model
numbers
Support Configurations
PowerStore T 1000T
3000T
5000T
7000T
9000T
Storage-centric deployments.
Both block (storage area networks (SAN)) and file
(network attached storage (NAS)) services are supported
with PowerStore T deployments.
Note: Hypervisor deployments are not supported on this
model.
PowerStore X 1000X
3000X
5000X
7000X
9000X
Application and storage-centric deployments.
Block (SAN-only) storage services with a hypervisor
layer installed on the system. The system software is
deployed on the hypervisor, which enables deployment
of virtual machines (VMs) and customer applications
within the hardware.
Note: File (network attached storage (NAS)) services are
not supported on this model.
Refer to the PowerStore product support pages (https://www.dell.com/support
) for detailed user documentation.
Known Issues
6 Dell EMC PowerStore Release Notes
Known Issues
The following high severity issues are reported in this release. For a list of the minor issues, see Knowledge Base article
SLN320772 PowerStore Release Notes Minor issues at: https://www.dell.com/support/article/SLN320772
Table 2 Known Issues in this release
Issue ID Functional Area Description Workaround/Resolution
MDT-152854 Connectivity - Hosts Running an unmap operation might
cause a host I/O latency impact of
more than 15%. You can disable
auto-unmap for applications that have
this feature, or manually schedule an
unmap operation to reduce the impact
on hosts.
Disable auto-unmap for applications
that have this feature. Schedule
unmap operations manually to
reduce the impact on hosts.
MDT-154342 Connectivity - Hosts When you add a host, in rare cases,
you may not see any active sessions
or connected paths for the initiators
for up to 10 minutes on the Initiators
tab.
Do not try adding the host again.
Wait for up to 10 minutes for the
active sessions to appear.
MDT-148696 Connectivity - Hosts
When there is an active I/O operation
occurring between a host and
ColdspellX Fibre Channel port on the
appliance, and there is a considerable
amount of logout and login activity
initiated by the hosts, the port may
report a BUSY status back to the host
even when the port is not
oversubscribed from a limits
standpoint.
Contact your service provider.
MDT-139488 Connectivity - Hosts Xcopy operations can impact host I/O
performance.
None
MDT-55667 Data Collection Storage container capacity metrics
are not available until I/O operations
have begun.
Look at the capacity metrics again
after I/O operations on the storage
container have been performed.
MDT-153333 Data Collection As the number of targets scale, node
CPU stats may include underlying
target stats multiple times inflating the
value and causing a discrepancy
between appliance CPU stats and its
underlying node CPU stats.
None
Known Issues
7 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-133408 Data Protection
When a volume group is created with
member volumes and is protected by
a protection policy that includes a
replication rule, the volume group
members may be delayed in being
replicated to the remote system until
the next RPO cycle. The default
replication rule RPO value in
PowerStore Manager is 1 hour, but it
can range from 5 minutes to 24 hours.
If the remote system connection is
healthy, the member volumes should
automatically be replicated to the
destination during the next RPO
cycle. To update the member
volumes on the destination before
the next RPO cycle, navigate to
Protection-> Replication, select the
volume group session and perform a
"Synchronize" operation.
MDT-148947 Data Protection From a protection perspective, a
snapshot of a volume group is a
single-point-in-time copy of the
volume group member volumes.
Membership changes to the volume
group prevent snapshot recovery
operations, such as restore or refresh,
unless the volume group is returned
to the same membership state at the
time the snapshot was created. It is
recommended that you do not delete
the volumes removed from a volume
group until all the snapshots of the
volume group either expire or are
removed manually.
If there are still volume group
snapshots, the delete request for the
volume returns the following error:
"The Volume <volume name> (id:
<unique id>) cannot be deleted until
all volume group snapshots taken
when this volume was a member of a
volume group expire or are manually
deleted." This error does not indicate
the name of the volume group that is
needed to delete the volume group
snapshots so the volume deletion can
succeed.
In PowerStore, first identify the
volume group name, if it is unknown,
by navigating to Snapshots table of
the removed member volume.
Volume group snapshots that have
been created by a protection policy
should have the volume group name
as part of the system-created
snapshot name for each member
volume. If there are only manual
snapshots, you can use REST API
to identify the volume group name.
The volume group snapshots can be
deleted by navigating to the
protection tab and viewing the
snapshots for the specific volume
group. Click Show/Hide Table
Columns and add the Volume
Members column. The column
appears and displays a number.
When you hover over that number,
the volumes within the VG snapshot
become visible. You can look for a
pattern by sorting this column. A
column with more members might
indicate that the VG snapshot has
the member that is preventing the
volume deletion operation, assuming
one or more members have been
removed and snapshots continued to
be created on the remaining VG
members.
MDT-146780 Data Protection When deleting a snapshot rule, the
snapshot rule may not appear to be
deleted, and the following error
appears: "The system encountered
unexpected backend errors. Please
contact support. (0xE0101001000C)".
Do not continue using the rule for
protection.
Delete the snapshot rule again. The
same error appears, but the rule will
be deleted.
Known Issues
8 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-117061 Hardware
When beginning cluster creation, the
hardware status is incorrectly
indicated as not configured for
clustering.
Wait a few minutes and try again.
MDT-137439 Import
If an import from a Unity or VNX2
system to PowerStore is cancelled by
the user or fails for some reason, it is
possible that subsequent attempts to
import the volume will also fail.
Remove the Unity or VNX2 as a
remote system and then add it
again. This action will clear the issue
and allow the import to proceed.
MDT-145764 Internal Migration During migration the temporary
volumes that are created during
migration are calculated into the vVol
capacity metrics. The temporary
volumes should not be included in the
calculation.
Wait for migration to complete to get
the correct calculation.
MDT-153885 Internal Migration If a volume is expanded while one of
the nodes is booting up, the size of
the volume might not be changed on
the node that is booting up. As a
result, I/O operations to the newly
expanded region of the volume fail.
Reboot the node that has the
problem or enter a ModifyVolume
command to increase the volume to
slightly larger size, which should
resolve the issue.
MDT-140927 Internal Migration
After a volume is migrated, there
maybe a dip in capacity and
performance metrics reporting for that
volume at the end of the migration
operation.
None
MDT-156905 Install or Upgrade After a software update, the NAS
servers may not fail back
automatically to the original node.
Manually fail back the NAS servers
from PowerStore Manager.
MDT-135505 Install or Upgrade
Drive firmware updates may not get
applied to a single or few drives within
the appliance. This may occur
because of a timing issue between
the two nodes in the appliance.
Download and install the drive
firmware again to ensure it gets
updated on the drives that were
missed in the previous attempt.
MDT-148659 Install or Upgrade If the peer node is inaccessible for too
long, the software upgrade can fail.
Retry the software upgrade.
Known Issues
9 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-155853 Monitoring
If there is a critical capacity based
forecasting alert, a migration
recommendation repair flow can be
used to migrate storage to another
appliance. It is possible that after
migration completes, the daily
forecast used to trigger the alert will
not be updated on the source
appliance and the alert will not be
cleared until the next daily forecast.
After the forecast is triggered again,
the capacity based forecast on the
source and destination appliance may
be inaccurate as a significant amount
of storage is migrated.
None
MDT-134036 Monitoring
When there is a contention of
resources, the performance policy
associated with the volume gets
applied. In the current release, you
may not notice much difference
between the High and Medium
performance policies. For volumes
with Low performance policy, expect
to see a noticeable difference in the
amount of I/O operations serviced as
compared to volumes with High or
Medium performance policies.
None
MDT-146346 Notifications and
Alerts
Some hardware alert states may
persist for a short time after the health
of the object has been restored. The
alert states eventually resolve with the
correct state.
None
MDT-153335 PowerStore CLI The PowerStore CLI does not show
all the required information for metrics
when a roll-up result is returned for
long interval values.
It is recommended that you use the
REST interface to query metrics.
You can also use any REST client
(cURL, Insomnia, Postman, etc.) or
web browser.
MDT-118394 PowerStore
Manager(GUI)
Uploading an upgrade package that is
larger than 4 GB with Microsoft Edge
or Internet Explorer fails.
Try again with a different browser.
MDT-86305 PowerStore
Manager(GUI)
When you power down a node in
PowerStore Manager, the screen
does not automatically refresh the
state to indicate that the node is
getting powered off.
On the Hardware tab, click the
Refresh icon (appears on the top
right corner of the tab, next to the
base enclosure image) or refresh the
browser page.
Known Issues
10 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-142069
PowerStore
Manager(GUI)
There are situations when the system
is Out of Space where the UI is
unable to update its statistics. This
situation will be evident by a red
banner on the top of the screen. You
may see objects in the UI that are
incorrectly displayed as "0
MB/GB/TB" due to the inability for the
UI to query for system statistics.
None
MDT-145344
PowerStore
Manager(GUI)
While performing a Refresh Using
Related Volume or Volume Group
operation, you might receive an
exception error when you select
Choose One from the drop-down
before you click Refresh. If this
occurs, you must restart PowerStore
Manager.
When refreshing a resource, do not
select the "Choose One" entry in the
Refresh from Volume/Volume Group
drop-down.
MDT-130894 PowerStore REST
API
Two invalid resource_types, FEPort
and Initiator, may be returned by the
event and alert APIs.
Events or alerts with resource_type
FEPort or Initiator should ignore the
resource_type values.
External OpenAPI clients must
disable validation for the event and
alert APIs with resource_types of
FEPort or Initiator.
MDT-153026 Security When a drive is inserted into an
appliance, it will take time for D@RE
to unlock it. Most drives take a few
minutes. However, it takes more time
for a ColdStream drive to unlock. The
time is proportional to the size of the
ColdStream drive, for example, 7
minutes for 375 G, 15 minutes for 750
G, and 27 minutes for 1.5T. If you pull
a drive out before it is unlocked, the
drive will appear as disconnected.
However, the drive will not be
automatically removed from the
appliance.
If you intend to use the drive, re-
insert the drive and let the DARE
unlock complete. If you intend to
stop using the drive, re-insert the
drive, wait for enough time (time to
unlock + about 1 minute for other
overhead), and then remove the
drive. The drive will then become
disconnected and automatically
removed from the system.
MDT-121966 Storage - File
The File system deleted alert is
displayed as an active alert in
PowerStore T even after the file
system has been successfully
deleted.
Review the alert details, to confirm
the alert is for a file system that has
been deleted. Once confirmed,
ignore or acknowledge the pending
alert.
Known Issues
11 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-121784 Storage - File
After a NAS server is successfully
deleted, the alerts against the deleted
child objects of the NAS server such
as DNS servers, file systems, NFS
exports, or SMB shares, are not
cleared.
Review the alert details, to confirm
the alert is for a child object of a
successfully deleted NAS server.
Once confirmed, ignore or
acknowledge the pending alert.
MDT-139095 Storage - File While trying to create or delete a
snapshot the following error message
was returned: "Addition [or deletion]
of NFS Export failed due to [The path
[path_name] was not found on the
system and cannot be exported.]"
Wait for some time, and try the
action again.
MDT-147688 Storage - File SMB clients cannot connect to a NAS
server when the NAS server name is
more than 15 characters. This is
because by default the SMB server
computer name takes the NAS server
name.
Set the NAS Server name with 15
characters or less or set the SMB
server's computer name with 15
characters or less. To modify the
computer name, select all the
characters in PowerStore Manager,
and type the new name.
MDT-147508 Storage - File SMB Server cannot join the Active
Directory when the SMB server
computer name is more than 15
characters and the first 15 characters
of the SMB server computer name
are the same as another SMB
server's computer name.
Use a unique SMB server Netbios
name with 15 characters or less.
MDT-144836 Storage - File If a snapshot expiration is in progress
when the NAS Server has stopped
due to issues such as Failover,
Failback, or the NAS server is being
moved to another node, then a "NAS
node [nodename] is down," alert is
displayed in PowerStore Manager
and NAS management operations
become unavailable.
Wait for the NAS server to come
back up and stabilize and try the
operation again.
MDT-110930 Storage - File Access to a snapshot is denied when
there is only one snapshot created on
the file system, and access to the
snapshot is attempted at the time the
snapshot is refreshing.
Mount and umount the export on the
client.
Known Issues
12 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-142317 Storage - File
After configuring and running I/O
operations to SMB shares and NFS
exports events such as an appliance
or NAS server reboot, or a file system
unmount or remount may cause some
negative values to appear in the
saved file system performance
statistics exported from PowerStore
Manager (GUI).
None
MDT-118544 Storage - File
After a request is sent from the REST
API with an incorrect GUID, the error
message returned displays the invalid
UID:
00000000-0000-0000-0000-
000000000000.
Ignore the UID in the error message
and retry the request with the correct
GUID.
MDT-146793 Storage - File Uploading configuration files to a NAS
server, which were edited in
WordPad, does not work as expected.
Use vim or Notepad to edit
configuration files before uploading
them to the NAS server.
MDT-154600 Storage - File The following alert is sent during
upgrade "NAS server [server name]
fault tolerance is degraded due to
NAS upgrade procedure on a peer
NAS cluster node." However, once
upgrade is complete the alert is not
always automatically cleared.
After upgrade completes,
acknowledge the alert to clear it.
MDT-116676 Storage - File The "NAS node <node name> is
down," major alert may be seen after
changing the Cluster MTU value.
Changing the MTU value may cause
degradation or disruption in NAS (file)
services.
Wait for the alert to clear before
performing any further NAS (File)
operations.
MDT-137232 Storage - File Under rare circumstances, NAS
services could be disrupted, if the
appliance is close to reaching the
maximum used data capacity.
Take one of the following actions on
the appliance on which the NAS
service is installed: add capacity to
the appliance (for example, add
drives or expansion enclosures),
increase free capacity on the system
(for example, deleting unused
snapshots, volumes) , or migrate
data off the system.
MDT-151302 Storage - File
If the network connection is unstable,
the DNS may incorrectly be reported
as offline. After restarting the NAS
server, the health status of DNS is not
cleared if the DNS is healthy.
Refer to the Dell knowledge base
article SLN320669. Contact your
service provider, if you need
assistance.
Known Issues
13 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-149396 Support
If an event or issue abruptly interrupts
the node while the node, appliance, or
cluster is powering off, the node may
not complete powering off and a
reboot may occur instead.
Try powering off the node,
appliance, or cluster again.
MDT-148608 SupportAssist Attempts to upload Support Materials
fail. Support Assist is unable to
upload files when there is insufficient
free space in the system partition.
Delete old Data Collections to
increase the available space in the
file system so that Support Assist
can make a backup copy of the file
for upload.
MDT-153771 SupportAssist
Enabling either Direct connect with
remote access or Gateway connect
with remote access may fail.
If enabling either higher tier type,
Direct connect with remote access or
Gateway connect with remote
access, fails, wait for the backend
issue to clear, then do the following:
1. Enable the related lower tier type,
Direct connect without remote
access or Gateway connect without
remote access.
2. Disable the related lower tier type.
3. Re-enable the higher tier type,
Direct connect with remote access or
Gateway connect with remote
access type.
If the issue persists, contact your
service provider.
MDT-153919 SupportAssist
In multi-appliance clusters, data
collections taken on a peer appliance
may not be automatically uploaded to
SupportAssist.
A data collection can still be
uploaded to SupportAssist from a
peer appliance by manually selecting
it and uploading it.
MDT-109970 Virtualization Unable to create a vVol storage
container in PowerStore, after having
just deleted a vVol datastore with the
same name from vSphere.
Either create the vVol storage
container in PowerStore using a
different name or allow some more
time before creating the new vVol
storage container in PowerStore with
the same name that was used in
vSphere.
MDT-111956 Virtualization In rare case, the automated mounting
of a user-created PowerStore vVol
storage container on an ESXi host
could fail with the following error
message displayed in vCenter
"Timed-out waiting to get datastore
information from host".
Manually mount the vVol storage
container from the VMware vSphere
GUI or CLI.
Known Issues
14 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-156507 Virtualization
In high scale VMware vSphere
environments, where the ESXi hosts
and vCenter server are highly loaded
(for example, simultaneous powering
on a large number of VMs), heartbeat
messages sent by the ESXi hosts to
the vCenter server may not be
delivered in time. When the heartbeat
is not received in the 60-second
timeout interval, the host is
considered as not responding, and
the host is marked as disconnected.
This may result in the vSphere High
Availability (HA) to trigger VM
migrations to other hosts in the
cluster.
In vCenter server, increase the
heartbeat timeout interval to 120
seconds. See VMware Knowledge
Base article 1005757. In case some
VMs appear as invalid or orphaned
as a result of the ESXi host
disconnect, see the VMware
Knowledge Base article 1003742 for
instructions on recovering the VMs.
MDT-146763 Virtualization During a vMotion process, some
vVols are deleted. If the VASA
provider becomes unavailable during
a storage vMotion operation, the
deletion of the vVols fails. These
vVols are left orphaned and may
appear as duplicates.
Delete the orphaned vVols using
PowerStore CLI or REST API.
MDT-151804 Virtualization Refer to the Dell knowledge base
article SLN320477: “Best practices
for VMFS datastores for Bootstorm
or Failover with VMware SRM” for
additional details.
MDT-152993 Virtualization A periodic, automatic cleanup process
on vSphere that is performed
randomly (every few days) deletes
empty config vVols (directories).
However, this process also deletes
the ISOs folder that is pre-created by
Trident in case you have not placed
any ISO images into the folder.
Recreate the ISOs folder using the
following PowerStore CLI command:
pstcli -service storage_container -id
<id where to create the folder>
create_directory -size 100G -name
ISOs
By default PowerStore creates a 500
GB folder, but you can specify
another size if necessary.
Known Issues
15 Dell EMC PowerStore Release Notes
Issue ID Functional Area Description Workaround/Resolution
MDT-119414 Virtualization
Deploying a VM fails, and checking
the vvold.log vCenter log file reveals
the following messages:
2019-11-15T05:24:35.161Z info
vvold[2112740] [Originator@6876
sub=Default]
VVolAbandonedObjectScan::Process
Namespace examining namespace
/vmfs/volumes/<storage-container-
identifier>/<vvol-identifier>
and
2019-11-15T05:24:35.318Z warning
vvold[2112740] [Originator@6876
sub=Libs] 2112740:VVOLLIB :
VVolLib_OpenObjectTrackingFile:113
48: VVolLib_OpenObjectTrackingFile:
Failed to open object tracking file
/vmfs/volumes/<storage-container-
identifier>/<vvol-identifier>
/.vvolObjList with error 6
where <storage-container-identifier>
is the UUID of the storage container
and <vvol-identifier> is the
alphanumeric identifier of the config-
vVol of the VM.
Try to deploy the VM again. For
more information, see the Dell
knowledge base article SLN320647.
MDT-146912 Virtualization
In PowerStore X model, when both
ESXi hosts of the appliance are
rebooted simultaneously (for
example, due to a power failure),
ESXi iSCSI parameters (path
selection policy, Round Robin IOPS
limit, number of outstanding IOs with
competing worlds) of one or both
nodes may be reset to the default
ESXi values. This may affect IO
performance.
Refer to the Dell knowledge base
article SLN320780 for more
information on resetting the values of
the ESXi iSCSI parameters.
Refer to the PowerStore product support pages (https://www.dell.com/support
) for detailed user documentation.
Limitations
16 Dell EMC PowerStore Release Notes
Limitations
The following limitations exist in this release.
PowerStore T and PowerStore X model limitations
The following limitations exist in PowerStore T and PowerStore X deployment models.
Functional Area Description
Importing external storage
to PowerStore
A maximum of 16 import sessions is supported in the Ready-For-Cutover state
during an import. In some cases, when several dozen import operations are run
back-to-back, intermittent failures of alternate import sessions may occur. If this
occurs, do the following:
1. Remove the remote system and then add it again.
2. Run fewer set of imports (16 or less) at a time. It is recommended to start all
these import sessions with automatic cutover turned off.
3. Once all imports have reached the Ready-For-Cutover state, do a manual
cutover.
4. After one set of imports is completed, run the next set of imports after a
delay of 10 minutes. This delay allows enough time for the system to
cleanup any connections to the source system.
PowerStore Management
access
There are some management functions which might be not available through the
appliance IP address. This is a known issue and we recommend using only the
cluster management IP address for managing the cluster.
PowerStore scalability
limits
The PowerStore Simple Support Matrix lists the scalability limitations in PowerStore
models. The PowerStore Simple Support Matrix is available from the Dell E-Lab
Navigator at: https://elabnavigator.emc.com/eln/elnhome
SCSI Persistent
Reservations Support
SCSI-2 clusters are not supported. Only the following SCSI-3 persistent reservation
(PR) clusters are supported:
SCSI-3 PR is supported for single appliance PowerStore clusters, both for
PowerStore T model and PowerStore X model appliance types.
In a PowerStore T model cluster with more than one appliance, SCSI-3 PR
is supported. However, internal migration of vVols between appliances in a
cluster is only supported for vVols without SCSI-3 PR when you are running
VMware vSphere 6.7 P02 or later. Support for internal migration of vVols
with SCSI-3 PR may be available in a future VMware vSphere release.
Note: In this release, a PowerStore X model cluster can contain only one appliance.
SupportAssist
SupportAssist cannot be enabled on PowerStore models configured with IPv6 for the
management network. SupportAssist is not supported over IPv6.
Installation and Upgrade Considerations
17 Dell EMC PowerStore Release Notes
PowerStore X model limitations
The following limitations exist in PowerStore X deployment models.
Functional Area Description
Clustering
Clustering with multiple PowerStore X appliances is not supported.
Replication of Virtual
Volumes (vVols)
Replication of vVols is not supported.
Storage - File
NAS services are not supported in PowerStore X models.
Support for Virtual
Machines
Virtual Machines (VMs) running on PowerStore X internal nodes only
supports Virtual Volumes (vVols). Virtual Machine File System (VMFS) is
not supported for internally running VMs, but is supported when using
PowerStore X with external ESX servers attached via Fibre Channel or
iSCSI.
Refer to the PowerStore product support pages (https://www.dell.com/support) for detailed user documentation.
Installation and Upgrade Considerations
Before you begin to install PowerStore, review the PowerStore Deployment Checklist. Once you have completed all the
planning steps in the PowerStore Deployment Checklist, you are ready to install your system.
The PowerStore Deployment Checklist, as well as all other PowerStore documentation, can be downloaded from the
PowerStore Documentation page at: www.dell.com/support
.
Environment and System Requirements
All PowerStore deployment models must meet the following environment and system requirements…
Support Matrix
Refer to the PowerStore Support Matrix on the support website for compatibility and interoperability information.
Where to Get Help
Dell Technologies maintains support pages for all products at www.dell.com/support.
The product support pages provide important product information such as product and user documentation, knowledge
base articles, drivers and other software installation packages downloads, advisories, knowledge base articles, and more.
A valid support contract and registration is required to access all information available on the product support sites.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI