Thermasol OSS-SB Installation guide

Type
Installation guide

Thermasol OSS-SB steam head is a high-quality steam outlet designed for installation in shower walls or walls above bathtubs. It allows you to enjoy the benefits of steam therapy in your own home. The steam head is made of durable materials and is easy to install. It comes with an escutcheon for a clean and finished look. The steam head is designed to be located 12"-16" from the steam room floor and a maximum of 6" from the corner of the room. It should be placed as far away from the controller and bather as possible for safety reasons.

Thermasol OSS-SB steam head is a high-quality steam outlet designed for installation in shower walls or walls above bathtubs. It allows you to enjoy the benefits of steam therapy in your own home. The steam head is made of durable materials and is easy to install. It comes with an escutcheon for a clean and finished look. The steam head is designed to be located 12"-16" from the steam room floor and a maximum of 6" from the corner of the room. It should be placed as far away from the controller and bather as possible for safety reasons.

Questions? Call: 800-776-0711
81170 REV F
Steamhead Installation
Instructions for Standard OSS steam head to be installed by a qualified plumber
Parts Enclosed
OSS-XX Steamhead
Escutcheon
Material Needed
Clear Silicone
Tools Needed
Pipe Wrench
7/8” cutting tool
Silicone gun
Other tools as required
*Prior to any work being done, turn the power and water off to the product and
read these instructions in their entirety. Insure plumbing is cool enough to work
on.
1. Drill a 7/8” diameter hole in the shower wall or wall above the bathtub for the steam outlet line. Refer
to figure 3A as a guide for the proper location of the hole. See Steam Generator instructions for
additional information. Locate 12”-16” from steam room floor and 6” Max. from steam room corner.
locate the steam head as far away from the controller and bather as possible.
2.
CAUTION: The steam head is hot! And should not be located near a seat or bench! Locate at
the maximum distance from user(s) as possible.
3. Connect ½” F.I.P. copper pipe or copper tubing and ½” brass union onto the steam outlet. Run a ½”
copper pipe from the union to the 7/8” hole in wall. Do not use galvanized pipe. See figure below.
4. Attach the steam head and escutcheon to the copper pipe, The steamhead must be sealed to the
wall to create a vapor barrier to prevent water getting into the shower walls.
CAUTION: Do not obstruct the steam line with any shut-off valves, plugs or caps. ALL steam
generators are designed to build NO PRESSURE.
The steam line can run up, down, or horizontal; but cannot run down and then up. If it does, a
steam trap will be produced at the low point blocking the flow of steam. Insulate the steam outlet
piping if the piping run exceeds 10 feet or is exposed to cold areas. NOTE: Use steam rated
insulation (225°F Min.).
5. You may turn power back on.
**Avoid contact with steam head! It will burn you. Avoid direct contact with the steam
coming out of the steam head! It is extreamly hot! It will burn you!
  • Page 1 1

Thermasol OSS-SB Installation guide

Type
Installation guide

Thermasol OSS-SB steam head is a high-quality steam outlet designed for installation in shower walls or walls above bathtubs. It allows you to enjoy the benefits of steam therapy in your own home. The steam head is made of durable materials and is easy to install. It comes with an escutcheon for a clean and finished look. The steam head is designed to be located 12"-16" from the steam room floor and a maximum of 6" from the corner of the room. It should be placed as far away from the controller and bather as possible for safety reasons.