iQ Series
AUTOMATION-CONTROLLED PROBE GENERATORS
LS
Users Manual
Dukane Part No. 403 - 572 - 03
www.dukane.com/us
AUTOMATED HAND PROBE PRESS
Page ii Dukane Manual Part Number 403-572-03
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Copyright © 2013
Notice of Rights:
All rights reserved. No part of this manual including the interior design,
cover design and icons may be reproduced, transmitted or utilized in any
form or by any means, electronic, mechanical, photocopying, record-
ing, or by any information storage and retrieval system, without written
permission from the manufacturer.
Notice of Liability:
The information contained in this manual is distributed on an “As is”
basis, without warranty. While every precaution has been taken in the
preparation of this manual, the manufacturer shall not have any liability
to any person or entity with respect to any liability, loss, or damage
caused or alleged to be caused directly or indirectly by the instructions
contained in this manual, or by the hardware products described herein.
Specications subject to change without notice.
This users manual documents product features, hardware, and controls
software available at the time the manual was published.
Printed in the United States of America
Part Number: 403 - 572 - 03
This ultrasonic equipment is manufactured under one or more of
the following U.S. Patents:
3,780,926 3,825,481 4,131,505 4,277,710 5,798,599 5,880,580 6,984,921 7,225,965
7,475,801 and 8,052,816
Page iii
Dukane Manual Part Number 403-572-03
Revision History
Revision Revision
Number Summary Date
- 00 Original release. 07/10/2008
- 01 System inputs signal description changes. 08/04/2009
Options, Section 10, expanded. Models added.
- 02 Rear panel revised. 06/30/2010
Web address updated.
Options, Section 10, revised.
Regulatory Agency Compliance statement updated.
- 03 Added Patent 8,052,816 to Page ii. 03/08/2013
Added to Section 2 - Health and Safety. General Considerations expanded.
Added to Section 6 - Process Control Settings.
Programming Examples, Pages 46-48.
Updated the Regulatory Agency Compliance statement on Page 92.
Added Warnings and Cautions re: Modications to Operate and E-STOP switches;
cable connections; lockout-tagout devices; third party modications to xtures;
and, lifting the equipment.
Added Index.
Repaginated as necessary.
Page iv Dukane Manual Part Number 403-572-03
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page left intentionally blank
Page v
Dukane Manual Part Number 403-572-03
Contents
Section 1- Introduction .......................1
General User Information
Read the Manual First
Notes, Cautions and Warnings
Drawings and Tables
Generator Overview
Key Generator Features
Section 2 - Health and Safety ..................5
General Considerations
Plastics Health Notice
Electrical Safety
Domestic Power Grounding
International Power Grounding
Section 3 - Installation ....................... 11
Unpacking
Placing
Vertical Panel Mount Chassis
Horizontal Bench Chassis
Horizontal Panel Mount Chassis
RFI Grounding
Connecting Cables
Manually Operated Probe System
Automation Controlled Probe System
Section 4 - Standard Connections ...........21-25
Panel Layout Overview
Vertical Panel Mount Chassis
Horizontal Bench Chassis
AC Power Inlet Panel
IEC AC Power Inlet Connector
Power Switch/Circuit Breaker
Chassis Ground Stud
Continued
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page vii
Page vi Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
Contents Continued
Section 4 - Standard Connections ............ 26-33
System I/O Panel
System Inputs Connector
System Inputs Connector Pinout
System Inputs Signal Descriptions
System Outputs Connector
System Outputs Connector Pinout
System Outputs Signal Descriptions
Ultrasound Output Connector
Conguration Port Connector
Section 5 - Standard System Status and Controls ..35
Control Panel and Display
Overview
Display Controls
LCD Display
Power Output Level Scale
System Operating Mode Keys
INFO Key
Status LEDs
System Parameter Settings
Section 6 - Process Control Settings .............43
User- Provided Process Control Overview
Manual Welding
Automated Welding
Automated Process Control Input Signals
Status Output Signals
Programming Examples
Section 7 - System Operational Testing...........49
System Verication Tests
System Test
Probe Operation
Stop Ultrasound Output
Continued
Section 1 – Introduction
Page vii
Page vi Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
Section 8 - Troubleshooting ....................55
No Ultrasonic Output
INFO Status LED: RED
Welding Problems
Section 9 - Maintenance........................61
Display/Control Panel
Chassis
Section 10 - Options...........................65
Power Inlet Options
I/O Panel Options
Option Panel Modules
Section 11 - Specications .....................85
Drawings
Weight
Operating Environment
AC Power Requirements
Interpreting the Model Number
Regulatory Agency Compliance
Section 12 - Contacting Dukane .................93
Appendices ..................................97
List of Figures .................................... 99
List of Tables ....................................101
Index ...................................103
Contents (Continued)Contents (Continued)
Contents Continued
TM
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 1
Page viii Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
Page left intentionally blank
Section 1 – Introduction
Page 1
Page viii Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
SECTION 1
Introduction
General User Information ........................... 3
Read The Manual First ....................................3
Notes, Cautions and Warnings ..............................3
Drawings and Tables......................................3
Generator Overview ................................ 4
Key Generator Features............................. 4
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 3
Page 2 Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
Page left intentionally blank
Section 1 – Introduction
Page 3
Page 2 Dukane Manual Part Number 403-572-03Dukane Manual Part Number 403-572-03
General User Information
Read This Manual First
Before operating your ultrasonic generator, read this
Users Manual to become familiar with the equipment.
This will ensure correct and safe operation. The manual is
organized to allow you to learn how to safely operate this
generator. The examples given are chosen for their sim-
plicity to illustrate basic operation concepts.
Notes, Cautions and Warnings
Throughout this manual we use NOTES to provide infor-
mation that is important for the successful application and
understanding of the product. A NOTE block is shown to
the right.
In addition, we use special notices to make you aware
of safety considerations. These are the CAUTION and
WARNING blocks as shown here. They have important
information that, if ignored, could have increasingly se-
vere outcomes. These statements help you to identify and
avoid hazards and recognize the consequences. One of
three different symbols also accompany the CAUTION
and WARNING blocks to indicate whether the notice per-
tains to a condition or practice, an electrical safety issue or
a operator protection issue.
Drawings and Tables
The gures and tables are identied by the section num-
ber followed by a sequence number. The sequence num-
ber begins with one in each section. The gures and tables
are numbered separately. The gures use Arabic sequence
numbers (e.g. 1, 2, 3) while the tables use roman sequence
numerals (e.g. I, II, III). As an example, Figure 3- 2 would
be the second illustration in Section 3 while Table 3- II
would be the second table in Section 3.
CAUTION
Caution statements
identify conditions or
practices that could result
in damage to the equip-
ment or other property.
WARNING
Warning statements
point out conditions or
practices that could re-
sult in personal injury or
loss of life.
NOTE
Note statements provide additional
information or highlight procedures.
Condition
or Practice
Electrical
Hazard
Hearing
Protection
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 4 Dukane Manual Part Number 403-572-03
Generator Overview
This generator is designed for basic ultrasonic applications
that use either manually operated hand probes or ultrasonic
probes controlled by automation systems. Using the avail-
able system control inputs and output status signals, it can
easily be controlled by automated machines.
The generator design accepts several control input signals,
and provides system status output signals.
This product has rugged internal ultrasonic generator cir-
cuitry and ensures a continuous resonant frequency lock
at the start of each weld. The LCD display can be used to
change the factory default ultrasonic settings for the drive
signal phase delay angle, starting frequency and ramp-up
or ramp-down parameters. This enables users to modify
the generator performance to meet a wide variety of ultra-
sonic processing requirements.
The generators compact size allows multiple units to be
placed into an industrial equipment cabinet. This genera-
tor will operate at the same international line voltage input
specications as the other generators of this product fam-
ily (unless the 120V option is installed). It also includes an
RFI line lter that passes FCC, CE, UL, and CSA testing
for global applications.
Key Generator Features
• CompactEnclosureSize means that a very small foot-
print is required for the horizontal benchtop congura-
tion. It is also available in a vertical back–plate mount
conguration for incorporation into automated machine
cabinets. 220/240VAC systems - Rated at 1200 watts or
less, come in a low prole (3.5”) compact enclosure,
while systems rated above 1200 watts come in a high
prole (5.25”) standard enclosure size. 110/120VAC
systems - Rated up to 1200 watts, come in the high pro-
le (5.25”) enclosure.
Pulse Width Modulation incorporates cir-
cuitry giving the generator the ability to
efciently change the output amplitude. This makes
it possible to start large horns with reduced power. It
also provides more power efcient switch-mode gen-
erator operation and increased reliability.
LinearRampUp/Downcircuitry allows the acoustic
stack to be brought to operating amplitude smoothly,
minimizing start-up surges and undue stress to
stack and generator. This circuitry also allows de-
creases to amplitude as the weld cycle ends. The
stack is brought down from its maximum operat-
ing amplitude smoothly, reducing shock stress.
Digi-TracTuning tracks the resonant frequency
of the acoustic stack (horn, booster, and transduc-
er) and adjusts the generator output frequency to
match it. This is done for every weld cycle and
eliminates the need to manually tune the genera-
tor.
Line Voltage Regulation automatically main-
tains constant amplitude regardless of line volt-
age deviation. The available output power is
maintained with any voltage input within the
specied range. This provides consistent system
performance regardless of line voltage uctua-
tions. It also eliminates the need for bulky, exter-
nal constant-voltage transformers.
Load Regulation provides constant ultrasound
amplitude automatically regardless of power
draw. The ultrasonic output amplitude level is
held to within ±1% to provide weld process con-
sistency and reduced weld cycle times.
WideLineVoltageOperation means that stan-
dard systems will operate worldwide within their
standard AC voltage ranges.
Flow Through Cooling Tunnel with a high-
performance heatsink and thermostatically con-
trolled fan reduces thermal gradients and increas-
es component life.
AC Power Inrush protection reduces electrical
stress on the internal components by protecting
them from AC power start-up transient current
surges.
Multiple Electronic Overload protection cir-
cuits prevent instantaneous component failure in
the event of extreme output overload conditions.
• CE Certication means that the system meets
the required European standards to be sold and
used in Europe.
• ISO 9001 Certication means that this system
has been manufactured to high quality standards
and assures you of manufacturing excellence.
Section 2 – Health and Safety
Page 5
Dukane Manual Part Number 403-572-03
SECTION 2
Health and Safety
General Considerations ........................7
Plastics Health Notice..........................7
Electrical Safety ..............................8
Domestic Power Grounding ...................... 8
International Power Grounding .................... 8
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 6 Dukane Manual Part Number 403-572-03
This page intentionally left blank
Section 2 – Health and Safety
Page 7
Dukane Manual Part Number 403-572-03
ProperInstallation - Operate system components only
after they are properly installed.
NoUnauthorizedModications- Do not modify your
system in any way unless authorized to do so by Dukane
Corporation. Unauthorized modications could cause
equipment damage and/or injury to the operator. In ad-
dition, unauthorized modications will void equipment
warranty.
Keep the CoverOn - Do not remove any equipment
cover unless directed to do so by Dukane Corporation. The
generator produces hazardous electrical voltages which
could cause injury.
GroundedElectrical Power- Operate this equipment
only with a grounded electrical connection.
See Electrical Safety for grounding instructions, Page 9.
ComplywithRegulations- You may be required to add
accessories to bring the system into compliance with
applicable regulations (OSHA in the USA) for machine
guarding and noise exposure.
UseEyeProtection - Wear ANSI approved safety impact
goggles.
AcousticStackHazard - When an acoustic stack (trans-
ducer, booster, horn and tip) is energized by the ultrasound
signal, it presents a potential hazard. Stay clear of an
energized stack.
SystemE-STOP(abort) Switch - Install asystem E-
STOP (abort) switch at each operator station when ultra-
sonic plastic assembly equipment is used with automatic
material handling equipment in an automated system.
FootSwitch - Using a foot switch in place of the optical
touch nger switches (operate switches) violates OSHA
regulations.
NOTE
These recommendations apply to the
welding system. System in this manual
refers to a complete group of components
associated with the welding of parts, also
known as an ultrasonic assembly system.
A typical iQ Series System consists of the iQ
generator, a press with thruster, switches,
controls, cables, transducer, booster, horn,
xture, and iQ Explorer II software.
CAUTION
At some time you may be
asked to remove equipment
covers by the Dukane Ser-
vice Dept. personnel. Before
doing so, disconnect the unit
electrically from the incoming line AC
power. If the unit is a press/thruster,
lock the Air Lockout Valve, located on
the rear panel, in its closed position.
General Considerations
Please observe these healthandsafetyrecommenda-
tions for safe, efcient, and injury-free operation of your
equipment.
WARNING
Never operate the genera-
tor with the cover off. This
is an unsafe practice and
may cause injury.
Any xture manufactured by
a third party must comply
with all OSHA and ANSI re-
quirements. All xtures must
be guarded as necessary.
Dukane Corporation does not as-
sume any responsibility or liability
for fixtures manufactured by the
customer or any third party manu-
facturer.
WARNING
Continued
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 8 Dukane Manual Part Number 403-572-03
Pre-triggerSwitchAdjustment - The pre-trigger switch
option starts the horn vibrating before contacting the part
to be welded. To ensure safe operation, adjust the pre-
trigger so the ultrasound signal will not activate if the
horn is more than ¼ in (7 mm) from the part to be welded.
SystemElectrical Cabling- Electrical power must be
off when connecting or disconnecting electrical cables.
Do NotWear Loose Clothing orJewelry - They can
become caught in moving parts.
StayAlert - Watch what you are doing at all times. Use
common sense. Do not operate the press when you are
tired or distracted from the job at hand.
Do not Operate the Equipment - Your judgement or
reexes could be impaired while taking prescription medi-
cations. If so, do not operate the equipment. Be familiar
with warning labels and recommended activity restrictions
that accompany your prescription medications. If you have
any doubt, do not operate the equipment.
General Considerations
CAUTION
Parts being joined ultrasoni-
cally will at times vibrate at
audible frequencies. Wear ear
protectors to reduce annoying
or uncomfortable sounds. In addition,
ultrasound bafes, sound enclosures,
or materials that absorb sound may
be located to surround the system.
WARNING
Keep head, hands, limbs
and body at least six inch-
es (152 mm) away from an
operating press/thruster.
A vibrating, descending horn can cause
burns and/or crushing injuries.
CAUTION
Plastics Health Notice
Certain plastic materials, when being processed, may
emit fumes and/or gases that may be hazardous to the
operators health. Proper ventilation of the work station
should be provided where such materials are processed.
Inquiries should be made to the U.S. Department of Labor
concerning OSHA regulations for a particular plastic prior
to processing with Dukane ultrasonic equipment.
Electrical Safety
The iQ Series generator provides the operating power
and power returns. Make sure the generator is grounded
properly.
In addition to the safety considerations, proper grounding
is essential for the effective suppression of RFI (Radio
Frequency Interference). Every generator contains a RFI
lter which blocks noise on the AC power line from enter-
ing the generator control circuitry. This lter also prevents
ultrasonic RFI from being fed back into the AC power line.
If you experience problems with RFI from the press, run
an additional grounding wire from the press base ground-
ing stud to the nearest grounded metal pipe or equivalent
earth ground by means of a ground clamp. Use at least 14
AWG wire for the connection to the press base.
Continued from Previous Page
Continued
When making cable connec-
tions to system equipment or
disconnecting cables from
system equipment, make
sure electrical power to the system is
turned off, and AC power cords are re-
moved from their receptacles. After the
cables have been securely connected and
the connections and cable routing checked
a nal time, the power may be restored.
Section 2 – Health and Safety
Page 9
Dukane Manual Part Number 403-572-03
Approved 2 pole, 3 wire grounding
receptacle HUBBELL No. 5652 or
equivalent to NEMA 6–15R or 6–20R
Figure 2–1 Example of 220/240 Volt,
Grounded, 3-Prong Receptacle
CAUTION
If there is any question
about the grounding of your
receptacle, have it checked
by a qualified electrician.
Do not cut off the power cord ground-
ing prong, or alter the plug in any
way. If an extension cord is needed,
use a three-wire cord that is in good
condition. The cord should have
an adequate power rating to do the
job safely. It must be plugged into a
grounded receptacle. Do not use a two-
wire extension cord with this product.
CAUTION
If you have a two-prong
electrical receptacle, we
strongly recommend that
you replace it with a prop-
erly grounded three-prong type. Have
a qualied electrician replace it fol-
lowing the National Electric Code and
any local codes and ordinances
that apply. See Figures 2-1 and 2-2.
Electrical Safety
Domestic Power Grounding
For safety, the power cords used on this product have a
three-wire, grounding-type power cord. Figure 2-1 il-
lustrates the appropriate electrical outlet to use with the
power cord that is included with systems shipped to North
America.
International Power Grounding
The power cable normally provided for international use is
compatible with the power outlet used in many Continen-
tal European countries (Refer to Figure 2–2.) However,
if your application requires another type of power cord,
check with your equipment supplier, and follow local reg-
ulations concerning proper wiring and grounding.
Figure 2–2 International 220/240V Grounding
Grounding Contacts
Typical Outlet
Provided Cable
100/120 Volt AC Systems
(North America or Japan)
The power cord (including strain relief) supplied
with the 100/120VAC systems is permanently
attached to the rear of the generator. Units with this
power cord are for use in North America or Japan.
Continued from Previous Page
NOTE
See Section 10, Options if your system
has a non-detachable power cord for
120VAC operation.
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 10 Dukane Manual Part Number 403-572-03
1. Stand close to the load with your feet spread
apart about shoulder width, with one foot
slightly in front of the other for balance.
2. Squat down bending at the knees (not your
waist). Tuck your chin while keeping your
back as vertical as possible.
3. Get a rm grasp of the object before begin-
ning the lift. Begin slowly lifting with your
LEGS by straightening them. Never twist
your body during this step.
4. Once the lift is complete, keep the object as
close to the body as possible. As the load’s
center of gravity moves away from the body,
there is a dramatic increase in stress to the
lumbar region of the back.
5. If you must turn while carrying the load,
turn using your feet-not your torso. To place
the object below the level of your waist, fol-
low the same procedures in reverse order.
Remember, keep your back as vertical as
possible and bend at the knees.
CAUTION
Take care when lift-
ing the equipment. We
recommend using a me-
chanical lift device to assist.
How to Lift Safely
Before lifting, take a moment to think about what
you’re about to do.
Examine the object for sharp corners, slippery spots
or other potential hazards. Know your limit and don’t
try to exceed it.
Ask for help if needed, or if possible, divide the load
to make it lighter.
Know where you are going to set the item down, and
make sure it and your path are free of obstructions.
Then follow these steps:
Lifting the Equipment
NOTE
For equipment weights see Section 11,
Specications, Page 89.
Section 3 – Installation
Page 11
Dukane Manual Part Number 403-572-03
SECTION 3
Installation
Before Installation ................................ 13
When to Use Lockout/Tagout Devices ...................... 13
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Placing ......................................... 15
Vertical Panel Mount Chassis ............................. 15
Horizontal Bench Chassis................................ 16
Horizontal Panel Mount Chassis........................... 16
RFI Grounding ................................... 17
Connnecting Cables ............................... 18
Manually Operated Probe System ......................... 18
Automation Controlled Probe System....................... 19
iQ Series, Automation-Controlled Probe Generators LS User’s Manual
Page 12 Dukane Manual Part Number 403-572-03
This page intentionally left blank
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116