Command access LPM110 Installation guide

Type
Installation guide
LPM Series
Doc # xxxxx rev.x
1
INSTALLATION INSTRUCTIONS
Visit our website for more details
www.CommandAccess.com
U.S. Customer Support
1-888-622-2377
Canada Customer Support
1-855-823-3002
A.
LPM Series Includes
A. LPM Mortise Lock
B. PM300
C. 2- Power Leads
The Command Access Latch Pullback Mortise Lock retracts the latch for push/pull operation. These
instructions cover all series from LPM110-LPM188.
B.
C.
LPM
72” WIRE HARNESS (3-PRONG)
PM300
72” WIRE HARNESS (2-PRONG)
72” WIRE HARNESS (3-PRONG)
C.
24 VDC
Power Supply
2
Note: For LPM1 series option placement is only
recommended for Hollow metal doors. For wood doors, use
standard placement above ceiling tile or in junction box.
Module
Ceiling Tile
LPM1 Series Installation
Example
Module
Standard Placement
Hinge Pocket
Option Only
Standard Placement
Optional Placement
1. The door must be prepared with a standard type 86 mortise lock preparation and a 3/8” wire
raceway. Be sure that the mortise pocket and the raceway are clear of debris prior to installation.
2. Install the 3-prong, 72” wire harness through the wire raceway leaving enough slack to quick
connect to the mortise chassis.
3. Install PM300 at the hinge jamb side of the door within 120” of the lockset. Connect the 3-prong wire
harness to the PM300 and hard wire it directly to the harness from the lockset (if using an electric
hinge or other transfer device, use 18ga wire).
4. Connect the 2-prong input power wires (BLACK and BLACK) of the PM300 to the 2-prong, 72” wire
lead. Then connect the 72” wire lead directly to the wire run coming from the 26.5VDC power supply
(not included). The power supply may be up to 300 feet away (see power supply wiring instructions).
Note: these wires are not polarity sensitive.
3
12VAC/DC
24VAC/DC
or
Power
Supply
Bridge Rectifier
Energy Transfer Hinge
Switch
EU (Fail Secure)
EU (Fail Secure)
12VAC/DC
24VAC/DC
or
Power
Supply
Bridge Rectifier
Energy Transfer Hinge
Switch
EL (Fail Safe)
EL (Fail Safe)
Step 1 - The door must be preped according to origional manufactures
template, machined with a 3/8” wire raceway, & preped for
a energy transfer hinge.
Make sure the mortise pocket is free of debris.
Step 2 - Run the wires from the ETH hinge through the 3/8” race-
way starting at the ETH hinge & exiting into the mortise
pocket.
Step 3 - Screw the ETH hinge to the door. At this time DO NOT
connect the hinge wires on the jamb side to the wires
coming from the power supply.
Step 4 - Connect the wires exiting the mortise pocket to the
Bridge Rectifier (included).
Step 5 - Connect the Bridge Rectifier to the plug exiting the
mortise chassis.
Step 6 - Carefully slip the connected mortise lock chassis into
the mortise pocket paying close attention not to pinch
any wires
Step 7 - Mount the chassis per manufacturer’s instructions.
Step 8 - Connect the wires from the power supply at the ETH
hinge on the jamb side. Connect the hinge to the
jamb.
Mortise
Lock
Pocket
3/8 Wire Raceway
ETH Hinge Pocket
Bridge
Rectifier
Wire Transfer Hinge
Bridge
Rectifier
Plug
3/8 Wire Raceway
Mortise
Lock
Pocket
Mortise
Lock
Pocket
Mortise
Lock
Pocket
For Lever Control Solenoid on LPM models 183-188 Only
All other models skip to next page
4
LH/LHR
RH/RHR
Rotate 180 Deg.
Handing Screw
Handing Instructions for LPM
Template for non-deadbolt & deadbolt
STEP 1: Locate the handing screw. This screw is used to hand the
handles. The Locking side is opposite the screw.
STEP 2: To hand the latchbolt, remove the faceplate. Pull the
latchbolt out of the chassis and rotate, then release.
The latchbolt is spring loaded and will return on it’s
own.
1”
1-3/16”
1-23/32”
2-1/4”
2-9/64”
2-3/4”
3-9/32”
2-7/32”
1-1/4” diameter
cylinder hole for exterior
side only
5/8” diameter
thumb turn hole for
interior side only
(Optional for deadbolt function)
1” diameter
through hole
3/8” diameter
through hole
3/8” diameter
through hole
4-7/16”
6-1/8”
5
Doc # xxxxx rev.x
Visit our website for more details
www.CommandAccess.com
U.S. Customer Support
1-888-622-2377
Canada Customer Support
1-855-823-3002
TECHNICAL INFORMATION
Specications
Troubleshooting & Diagnostics
Operating Voltage Range: 24 VDC +/- 10%
Hold Current: 260 mA @ 24 VDC
Surge Current: 1.6 A for 350 ms @ 24 VDC
Peak Current: 7 A @ 24 VDC
Input wires to PM300 : Non-polarized Black (+)(-)
Output wire from PM300: Yellow=Pull Coil; Orange= Hold
Coil; Green=Common
Power Supply for PM300 and PM300D in High Output Mode:
In High Output mode, the PM300 is designed for & MUST BE
powered by the Command Access PS1, PS5-4, or PS5-6 power
supplies only.
Wire Run Guidelines:
For best results we recommend that your maximum wire run not exceed the following:
18ga.= 700’ 16ga. = 1000’ 14ga. = 1250’ 12ga. = 1500’.
Latch Retraction Lever Control
Operating Voltage Range:
Switches
REX: Green - Common (C)
Blue - Normally Open (NO)
Gray - Normally Closed (NC)
Green/Black - Common (C)
Blue/Black - Normally Open (NO)
Gray/Black - Normally Closed (NC)
LBM:
Check the Module is on High Output.
Conrm that power supply is a Command Access PS1, PS5-4, or PS5-6
24VAC/DC 350mA
12VAC/DC 700mA
  • Page 1 1