Gigabyte TO15-S40 User manual

Category
Servers
Type
User manual
TO15-S40-IA01
ORv3 GPU Server
4th Gen Intel® Xeon® - 1OU DP 4 x PCIe Gen5 GPUs Immersion Cooling
User Manual
Rev. 1.0
Copyright
© 2023 Giga Computing Technology CO., LTD. All rights reserved.
The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of Giga Computing.
Changes to the specications and features in this manual may be made by Giga Computing
without prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or
published in any form or by any means without Giga Computing's prior written permission.
Documentation Classications
In order to assist in the use of this product, Giga Computing provides the following types of documen-
tation:
User Manual: detailed information & steps about the installation, conguration and use of this
product (e.g. motherboard, server barebones), covering hardware and BIOS.

User Guide: detailed information about the installation & use of an add-on hardware or
software component (e.g. BMC rmware, rail-kit) compatible with this product.
Quick Installation Guide: a short guide with visual diagrams that you can reference easily for
installation purposes of this product (e.g. motherboard, server barebones).
Please see the support section of the online product page to check the current availability of these
documents.
For More Information
For related product specications, the latest rmware and software, and other information please visit our website at
http://www.gigabyte.com/Enterprise
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller
portal: http://reseller.b2b.gigabyte.com
For further technical assistance, please contact your GIGABYTE representative or visit
https://esupport.gigabyte.com/ to create a new support ticket
For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email:
Conventions
The following conventions are used in this user's guide:
NOTE!
Pieces of additional
information related to the current topic.
CAUTION!
Precautionary measures to
avoid possible hardware or software problems.
WARNING!
Alerts to any damage that might
result from doing or not doing specic actions.
Server Warnings and Cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING!
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the server.
WARNING!
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal
system components to cool before touching them.
WARNING!
This server is equipped with high speed fans. Keep away from hazardous moving fan
blades during servicing.
CAUTION!
Do not operate the server for long periods with the access panel open or removed. Operat-
ing the server in this manner results in improper airow and improper cooling that can lead to
thermal damage.
Danger of explosion if battery is incorrectly replaced.
Replace battery with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
CAUTION!
Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery
only with the same or equivalent type recommended by the manufacturer. Dispose of used bat-
teries according to the manufacturer’s instructions.
Electrostatic Discharge (ESD)
CAUTION!
ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU
PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE,
PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT-
TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER
WHEN HANDLING PARTS.
Always handle boards carefully, they can be extremely sensitive to ESD. Hold boards only by
their edges without touching any components or connectors. After removing a board from its
protective ESD bag or from the system, place the board component side up on a grounded, static
free surface. Use a conductive foam pad if available but not the ESD bag. Do not slide the board
over any surface.
System power on/off: To service components within the server, please ensure the power has
been disconnected.
e.g. Remove the node from the server chassis (to disconnect power) or disconnect the power
from the server chassis.
Make sure the system is removed from the rack before opening the chassis, adding, or removing
any non hot-plug components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present
on power, telephone, and communication cables. Turn off the system chassis and disconnect the
cables attached to the system before servicing the chassis. Otherwise, personal injury or equip-
ment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and
other parts. We recommend that you perform all procedures in this chapter only at an ESD work-
station. If one is not available, provide some ESD protection by wearing an antistatic wrist strap
attached to chassis ground (any unpainted metal surface on the server) when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensi-tive to
electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its
protective wrapper or from the system, place the board component side up on a grounded, static
free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide
board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over
two jumper pins. Some jumpers have a small tab on top that can be gripped with n-gertips or
with a pair of ne needle nosed pliers. If the jumpers do not have such a tab, take care when us-
ing needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the
pliers, never the wide sides. Gripping the wide sides can dam-age the contacts inside the jumper,
causing intermittent problems with the function con-trolled by that jumper. Take care to grip with,
but not squeeze, the pliers or other tool used to remove a jumper, or the pins on the board may
bend or break.
- 7 -
Table of Contents
Chapter 1 Hardware Installation ...................................................................................10
1-1 Installation Precautions .................................................................................. 10
1-2 Product Specications .................................................................................... 11
1-3 System Block Diagram ................................................................................... 14
Chapter 2 System Appearance .....................................................................................18
2-1 Front View ...................................................................................................... 18
2-2 Rear View ....................................................................................................... 19
2-3 Front Panel LEDs and Buttons ....................................................................... 20
2-4 RoT LEDs ....................................................................................................... 21
2-5 Front System LAN LEDs ................................................................................ 23
2-6 Storage LED ................................................................................................... 24
Chapter 3 System Hardware Installation ......................................................................25
3-1 Removing Compute Node from the Rack ...................................................... 26
3-2 Removing and Installing the Chassis Cover .................................................. 27
3-3 Installing the EDSFF SSD .............................................................................. 28
3-4 Removing and Installing the Heat Sink .......................................................... 29
3-5 Installing the CPU and Heat Sink ................................................................... 30
3-6 Removing and Installing Memory ................................................................... 32
3-6-1 Eight Channel Memory Conguration .....................................................................32
3-6-2 Removing and Installing a Memory Module ...........................................................33
3-6-3 Memory Population Table .......................................................................................33
3-6-4 Processor and Memory Module Matrix Table .........................................................34
3-7 Installing the GPU Card ................................................................................. 35
3-8 Removing and Installing the PCIe Card ......................................................... 39
3-9 Cable Routing ................................................................................................ 41
Chapter 4 Motherboard Components ...........................................................................44
4-1 Motherboard Components ............................................................................. 44
4-2 Jumper Settings ............................................................................................. 45
Chapter 5 BIOS Setup ..................................................................................................46
5-1 The Main Menu .............................................................................................. 48
5-2 Advanced Menu ............................................................................................. 51
5-2-1 Trusted Computing .................................................................................................52
5-2-2 Serial Port Console Redirection .............................................................................53
5-2-3 SIO Conguration ...................................................................................................57
5-2-4 PCI Subsystem Settings .........................................................................................58
- 8 -
5-2-5 USB Conguration ..................................................................................................60
5-2-6 Network Stack Conguration ..................................................................................61
5-2-7 Post Report Conguration ......................................................................................62
5-2-8 NVMe Conguration ...............................................................................................63
5-2-9 Chipset Conguration .............................................................................................64
5-2-10 Tls Auth Conguration ............................................................................................65
5-2-11 iSCSI Conguration ................................................................................................66
5-2-12 Broadcom BCM57416 Ethernet Network Connection ............................................67
5-2-13 VLAN Conguration ................................................................................................70
5-2-14 Driver Health ...........................................................................................................72
5-3 Chipset Menu ................................................................................................. 73
5-3-1 Processor Conguration .........................................................................................74
5-3-2 Common RefCode Conguration ...........................................................................77
5-3-3 UPI Conguration ...................................................................................................78
5-3-4 Memory Conguration ............................................................................................79
5-3-5 IIO Conguration ....................................................................................................82
5-3-6 Advanced Power Management Conguration ........................................................84
5-3-7 PCH Conguration ..................................................................................................86
5-3-8 Miscellaneous Conguration ..................................................................................89
5-3-9 Server ME Conguration ........................................................................................90
5-3-10 Runtime Error Logging Settings .............................................................................91
5-3-11 Power Policy ...........................................................................................................93
5-4 Server Management Menu ............................................................................. 95
5-4-1 System Event Log ..................................................................................................97
5-4-2 View FRU Information ............................................................................................98
5-4-3 BMC VLAN Conguration .......................................................................................99
5-4-4 BMC Network Conguration .................................................................................100
5-4-5 IPv6 BMC Network Conguration .........................................................................101
5-5 Security Menu .............................................................................................. 102
5-5-1 Secure Boot .........................................................................................................103
5-6 Boot Menu .................................................................................................... 106
5-7 Save & Exit Menu ......................................................................................... 108
5-8 BIOS POST Beep code (AMI standard) ....................................................... 110
5-8-1 PEI Beep Codes ...................................................................................................110
5-8-2 DXE Beep Codes .................................................................................................110
- 9 -
This page intentionally left blank
- 10 -
Hardware Installation
1-1 Installation Precautions
The motherboard/system contain numerous delicate electronic circuits and components which
can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully
read the service guide and follow these procedures:
• Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or
warranty sticker provided by your dealer. These stickers are required for warranty validation.
Always remove the AC power by unplugging the power cord from the power outlet before
installing or removing the motherboard or other hardware components.
• When connecting hardware components to the internal connectors on the motherboard,
make sure they are connected tightly and securely.
When handling the motherboard, avoid touching any metal leads or connectors.
• It is best to wear an electrostatic discharge (ESD) wrist strap when handling electronic
components such as a motherboard, CPU or memory. If you do not have an ESD wrist
strap, keep your hands dry and rst touch a metal object to eliminate static electricity.
Prior to installing the motherboard, please have it on top of an antistatic pad or within an
electrostatic shielding container.
• Before unplugging the power supply cable from the motherboard, make sure the power
supply has been turned off.
Before turning on the power, make sure the power supply voltage has been set according to
the local voltage standard.
Before using the product, please verify that all cables and power connectors of your
hardware components are connected.
To prevent damage to the motherboard, do not allow screws to come in contact with the
motherboard circuit or its components.
Make sure there are no leftover screws or metal components placed on the motherboard or
within the computer casing.
Do not place the computer system on an uneven surface
.
Do not place the computer system in a high-temperature environment.
• Turning on the computer power during the installation process can lead to damage to
system components as well as physical harm to the user.
If you are uncertain about any installation steps or have a problem related to the use of the
product, please consult a certied computer technician.
Chapter 1 Hardware Installation
Hardware Installation
- 11 -
1-2 Product Specications
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
System
Dimension
1OU
537(W) x 45(H) x 805.7(D) mm
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
CPU 4th Generation Intel® Xeon® Scalable Processors
Intel® Xeon® CPU Max Series
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon®
Silver Processor
Dual processor, CPU TDP up to 350W
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be
unavailable
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
Socket 2 x LGA 4677
Socket E
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
Chipset Intel® C741 Chipset
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
Security UEFI Secure Boot
Silicon root of trust
SNMP Support: V3
Memory 24 x DIMM slots
DDR5 memory supported only
8-Channel memory per processor architecture
RDIMM modules up to 96GB supported
3DS RDIMM modules up to 256GB supported
Memory speed: Up to 4800 MHz (1DPC), 4400 MHz (2DPC)
LAN Front side:
2 x 10GbE LAN ports (1 x Intel® X710-AT2)
Support NCSI function
1 x 10/100/1000 management LAN
Video Integrated in Aspeed® AST2600
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Storage 4 x 15mm E1.S NVMe hot-swappable bays
NOTE:
We reserve the right to make any changes to the product specications and product-related
information without prior notice.
- 12 -
Hardware Installation
Expansion Slot Riser Card CORC206 x 2:
1 x PCIe x16 (Gen5 x16) FHFL slot or 2 x PCIe x16 (Gen5 x8) FHFL slots,
from CPU_0, for GPUs
1 x PCIe x16 (Gen5 x16) FHFL slot or 2 x PCIe x16 (Gen5 x8) FHFL slots,
from CPU_1, for GPUs
Riser Card CORC207 x 2:
1 x PCIe x16 (Gen5 x16) FHFL slot or 2 x PCIe x16 (Gen5 x8) FHFL slots,
from CPU_0, for GPUs
1 x PCIe x16 (Gen5 x16) FHFL slot or 2 x PCIe x16 (Gen5 x8) FHFL slots,
from CPU_1, for GPUs
Riser Card CRSG01F x 2:
2 x PCIe x16 (Gen5 x16) low-prole slots on rear side
**Optional 2 x M.2 slots (COMTP61):
M-key
PCIe Gen5 x4
Support NGFF-22110 cards
Note: Supports GPUs TDP up to 350W with 8 GPUs conguration or 600W with 4
GPUs conguration.
Front I/O 2 x USB 3.2 Gen1
1 x VGA
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x NMI button
1 x Reset button
1 x System status LED
No. of Bus
Bars 1 x 48V Bus Bar
TPM 1 x TPM header with SPI interface
Optional TPM2.0 kit: CTM010
Hardware Installation
- 13 -
System
Management
Aspeed® AST2600 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
Dashboard
HTML5 KVM
Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
Sensor Reading History Data
FRU Information
SEL Log in Linear Storage / Circular Storage Policy
Hardware Inventory
Fan Prole
System Firewall
Power Consumption
Power Control
LDAP / AD / RADIUS Support
Backup & Restore Conguration
Remote BIOS/BMC/CPLD Update
Event Log Filter
User Management
Media Redirection Settings
PAM Order Settings
SSL Settings
SMTP Settings
Socket
Socket
Security
Security Server Operating Properties
Power SupplySystem fan
Operating
Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8%-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Hardware Installation
- 14 -
1-3 System Block Diagram
PCIe5.0 x16
PCIe5.0 x16 LP slot
PCIe5.0 x16
PCIe5.0 x16
PCIe5.0 x16
PCIe5.0 x16 LP slot
1 x PCIe5.0 x16 or 2 x PCIe5.0 x8 for GPU
PICe
switch
Riser Card
1 x PCIe5.0 x16 or 2 x PCIe5.0 x8 for GPU
PICe
switch
Riser Card
PCIe5.0 x16
PCIe5.0 x16
PICe
switch
Riser Card
1 x PCIe5.0 x16 or 2 x PCIe5.0 x8 for GPU
PICe
switch
Riser Card
1 x PCIe5.0 x16 or 2 x PCIe5.0 x8 for GPU
8-Channel DDR5, 12 x DIMMs
Up to 4800MHz (1DPC), 4400MHz (2DPC)
8-Channel DDR5, 12 x DIMMs
Up to 4800MHz (1DPC), 4400MHz (2DPC)
DMI3 x 4
PCIe3.0 x1
eSPI
SPI
VGA
USB 2.0
PCIe5.0 x8PCIe5.0 x8
4 x Slimline 4i
SPI 64MB
SPI 64MB
SPI 64MB
SPI 64MB
TPM
USB3.2 Gen1
2 x
USB3.2 Gen1
NCSI
PCIe3.0 x4
Intel
X710-AT2
2 x 10G LAN
PCH
Intel C741
chipset
CPU0
4th Gen Intel Xeon
Scalable processors
(LGA4677 Socket)
4th Gen Intel Xeon
Scalable processors
(LGA4677 Socket)
CPU1
ASPEED
AST2600
BMC
MLAN
10/100/1G
PHY
MAC
3 x UPI 16/20 GT/s
4-bay 15mm E1.S NVMe
- 18 -
System Appearance
Chapter 2 System Appearance
2-1 Front View
Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of
the LEDs.
No. Description
1. EDSFF E1.S SSD Bay
2. GPU Card Slot
3. PCIe Card Slot
4. VGA Port
5. Server Management LAN Port
6. Front Panel LEDs and Buttons
7. 10 GbE LAN Port
8. USB 3.2 Gen1 Port
9. GPU Card Slot
E1S0
E1S1
E1S2
E1S3
SLOT1
SLOT2
SLOT3
SLOT4
SLOT10SLOT9
1 1
932
4 5 6 7 8
System Appearance
- 19 -
2-2 Rear View
No. Description
1. Power Distribution Board to Bus Bar Connector
2. GPU Card Slot
3. GPU Card Slot
1
SLOT6SLOT5
SLOT6
SLOT7
SLOT8
2 3
- 20 -
System Appearance
2-3 Front Panel LEDs and Buttons
NMI
RST
2 3 4 5
1
No. Name Color Status Description
1. Reset Button -- -- Press this button to reset the system.
2. Power button
with LED
Green On Indicates the system is powered on.
Green Blink System is in ACPI S1 state (sleep mode).
N/A Off - System is not powered on or in ACPI S5 state (power off)
- System is in ACPI S4 state (hibernate mode)
3. ID Button with
LED(Note)
Blue On Indicates the system identication is active.
N/A Off Indicates the system identication is disabled.
4. NMI button -- --
Press this button for the server to generate a NMI to the
processor. If multiple-bit ECC errors occur, the server will
effectively be halted.
5. System Status
LED(Note)
Green Solid On System is operating normally.
Amber
Solid On
Critical condition, may indicate:
System fan failure
System temperature
Blink
Non-critical condition, may indicate:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
N/A Off
System is not ready, may indicate:
POST error
NMI error
Processor or terminator missing
(Note) If your server features RoT function, please see the following section for detail LED behavior.
- 21 -
System Appearance
2-4 RoT LEDs
NMI
RST
Status LED
ID LED
LED on Front panel(Note5)
ID LED Status LED
EC Firmware (FW) Authentication fail or not exit
EC FW is broken or not exit (Note1) OFF OFF
Authenticating/Recovering BMC/BIOS Images
Authenticating Images OFF OFF
Recovering BMC Active Flash Blinks Blue
4 times per second
Blinks Green
4 times per second
Recovering BIOS Active Flash Blinks Blue
4 times per second
Blinks Green
4 times per second
Authentication (AUTH) Pass
Recovering BIOS Active Flash OFF OFF
BMC : AUTH pass after doing recovery
BIOS : AUTH pass after doing recovery OFF OFF
BMC : AUTH pass after doing recovery
BIOS : AUTH pass OFF OFF
BMC : AUTH pass
BIOS : AUTH pass after doing recovery OFF OFF
- 22 -
System Appearance
NOTE!
1. EC FW is broken or not exited result in Microchip CEC1702 cannot load EC FW for authentication.
2 (1) Authentication fail include below scenarios
Conguration table is missing or modied
Public key is missing or modied
Protected area or signature is modied
Flash empty
3. if active ash is still authentication failed after recovery sequence, Microchip CEC1702 stop the process
and showing LED behavior.
4. If backup flash authentication is failed cause by configuration table, public key or protected area is
broken. Microchip CEC1702 stop the process and showing LED behavior.
5. Front panel LED is controlled by BMC or Microchip CEC1702. Once Microchip CEC1702 is working(Auth
or recovery), the front panel LED is controlled by Microchip CEC1702 and vice versa.
Active Flash Authentication (AUTH) Fail
BMC : AUTH Fail(Note2) Blinks Blue
1 time per second
Blinks Green
1 time per second
BIOS : AUTH fail(Note2) Blinks Blue
1 time per second
Blinks Amber
1 time per second
BMC : AUTH fail after doing recovery(Note3)
Blinks Blue
2 times per second
[ON OFF OFF]
Blinks Green
2 times per second
[ON OFF OFF]
BIOS : AUTH fail after doing recovery(Note3)
Blinks Blue
2 times per second
[ON OFF OFF]
Blinks Amber
2 times per second
[ON OFF OFF]
Backup Flash Authentication Fail(Note4)
BMC : AUTH fail
Blinks Blue
2 times per second
[ON OFF ON OFF]
Blinks Green
2 times per second
[ON OFF ON OFF]
BIOS : AUTH fail
Blinks Blue
2 times per second
[ON OFF ON OFF]
Blinks Amber
2 times per second
[ON OFF ON OFF]
System Appearance
- 23 -
2-5 Front System LAN LEDs
No. Name Color Status Description
1. 1 GbE Speed
LED
Yellow On 1 Gbps data rate
Green On 100 Mbps data rate
N/A Off 10 Mbps data rate
2. 1 GbE Link /
Activity LED
Green On Link between system and network or no access
Blink Data transmission or reception is occurring.
N/A Off No data transmission or reception is occurring.
3. 10 GbE
Speed LED
Yellow On 10 Gbps data rate
Green On 1 Gbps data rate
N/A Off 100 Mbps data rate
4. 10 GbE Link /
Activity LED
Green On Link between system and network or no access
Blink Data transmission or reception is occurring.
N/A Off No data transmission or reception is occurring.
21 43 43
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111

Gigabyte TO15-S40 User manual

Category
Servers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI