COP-USA AH75WP Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the COP-USA AH75WP Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
.Summarize
Outdoor full weather housing, body of housing was made by aluminum. Surface was
disposed, which has corruptproof. Using the traver-tip, convenience for adjustinginside
with fanheater and wiper. Suitting for bad enviromentwith lens decodercontrol
convenience. Structure is firmly, it is suit for outdoor.
.Technology Datas
1VoltageAC24V
2Operating temperature-5~45
3Weight 5.5Kg
Ⅲ.Main components and parameter
Input voltage AC24V
Heater ~24V(20W)
Fan
DC 12V1.2W
Temperature
control
Over 45℃,fan startup
Low -5℃,heater startup
Lens control
ZOOM/FOCUS/IRIS:±12V
Ⅳ.Measure
Ⅵ.Installation way
1Loosening two stainless steel hexagon screws (M4) of back-lid.
2Installing camera and lens on bottom board, adjusting to proper position.
3According Figure 1 to connect camera’s control wire and power supply. Noteplease
secern camera’s power supply DC12V or AC24V. If power supply is DC12Vcould get
DC12V from decoderwhich could offer Max. current is 850mA for Load.If power
supply is AC24V, could get AC24V form decoder.
4Covering the back-lid and tighten the screws. When usingplease not to put the wiper to
work continuously for long timesotherwise ,It will effect the use time.
Ⅶ.Connection Figure
Tr ansf or mer
CP U
CN3
COM
IRIS
ZOOM
FOCUS
GND
+12V
CN1 CN2
B URS H
NOP
GND
RX D
TXD
CN4
AC2 4 V
IN
AC2 4 V
OUT
CN5
FAN
CN6
CN7
CN8
Figure 1
CN3communication portreceipting TTL level
CN2offering camera’s power supply (DC12V)
CN4AC24V OUT could offer AC24V
CN6low 0 , heater will startup.
CN7connecting heater
CN8over 45℃, fan will startup;
Command For Wiper Function:
CALL 58 – Wiper ON
PRESET 58 – Wiper OFF
/