MULTIPLEX WBK10X Water Booster Pump 00216382 Owner Instruction Manual

Type
Owner Instruction Manual
Instruction Sheet
Subject: Installation Procedure
Model WBK10X Water Booster Pump,
P.N. 00216382 (220-240 VAC, 50/60 Hz)
1 of 32
PartNumber020006830 04/23/2018
MULTIPLEX
2100 FUTURE DR, SELLERSBURG, IN 47172
800-367-4233
WWW.WELBILT.COM
Contents
English ...................................................................................................... 1
German .................................................................................................... 7
French ..................................................................................................... 11
Spanish ...................................................................................................15
Italian ......................................................................................................19
Russian ...................................................................................................23
Exploded View .....................................................................................29
Declaration of Conformity ..............................................................31
Read These Before Proceeding:
n
Warning
To Avoid Serious Injury
Read the following warnings before beginning an
installation. Failure to do so may result in possible death
or serious injury.
DO Adhere to all National and Local Plumbing and
Electrical Safety Codes.
DO Turn off incoming electrical service switches when
servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation
tank(s) are tight (8mm). This check should be
performed with a wrench to ensure a quality seal.
DO Inspect pressure on regulators before starting up
equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges
of all equipment.
DO Handle CO
2
cylinders and gauges with care.
Secure cylinders properly against abrasion.
DO Store CO
2
cylinder(s) in well-ventilated areas.
DO Use proper protective equipment when
performing maintenance or cleaning on the unit.
DO NOT Throw or drop a CO
2
cylinder. Secure the
cylinder(s) in an upright position with a chain.
DO NOT Connect the CO
2
cylinder(s) directly to the
product container. Doing so will result in an
explosion, causing possible death or injury. Best
to connect the CO
2
cylinder(s) to a regulator(s).
DO NOT Store CO
2
cylinders in temperatures above 125°F
(51.7°C), near furnaces, radiator or sources of heat.
DO NOT Release CO
2
gas from old cylinder.
DO NOT Touch refrigeration lines inside units. Some may
exceed temperatures of 200°F (93.3°C).
NOTE: Water pipe connections and fixtures directly
connected to a potable water supply shall be sized,
installed, and maintained in accordance with Federal,
State, and Local codes.
n
Warning
Disconnect and lock out all electrical power sources
before performing service or maintenance on this
machine – except when electrical tests are being
performed by qualified service personnel.
n
Warning
The appliance is not to be used by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
Children must be supervised and are not to play with
the appliance.
2 of 32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
ATTENTION: PRESSURE REQUIREMENTS
Max. inlet water pressure: 0.345 MPa (3.45 bar) (50 psi)
Min. inlet water pressure: 0.138 MPa (1.38 bar) (20 psi)
INTRODUCTION
The following instructions cover the installation of a
220VAC,50/60Hz (international) booster. An appropriate
3-wire power receptacle must be located within 6ft (1.8m)
of the Booster Kits.
Unpack the unit from its transportation packaging and
visually check for any signs of damage.
NOTE: Do not plug in Booster Pump Module at this time.
Installation
Important
This booster pump is intended to be installed outside
zone 1 and 2, as specified in IEC 60364-7-701.
The booster pump needs to be installed with a horizontal
distance to possibly spraying water of 1.8 meter. It is not
allowed to install the water booster above or below
(vertically) of possibly spraying water sources.
The water booster has to be installed vertical and NOT
horizontal.
PREPARING THE POWER CORD/MAINS LEAD
INTERNATIONAL UNITS ONLY P.N.00216382
Important
The wires in the power cord/mains lead are colored in
accordance with the following code:
Green / Yellow = Ground/Earth
Blue = Neutral
Brown = Line/Live
1. Locate a 3-terminal plug. This plug (not furnished with
kit) must have a ground-wire-connecting terminal.
2. Locate the loose end of the power cord attached to
the kit. All three (3) wires are stripped to 1/2" (1.3 cm)
length from the end.
3. Connect all three (3) wires to the plug using the
1/2" (1.3 cm) stripped ends or any other terminal
requirements. Different plugs and terminals may
require different stripped lengths.
4. Inspect the cord and plug connection for any loose or
bare wires.
GROUNDING INSTRUCTIONS
The Multiplex Model WBK10X WaterBoosterPump should
be grounded/earthed. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electrical current. This
product is equipped with a cord having a grounding/
earth wire with an appropriate grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
n
Warning
Risk of Electric Shock
This kit is supplied with a ground conductor and
grounding-type attachment plug (domestic only). To
reduce the risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-
type receptacle.
NOTE: For 220-240VAC,50/60Hz International Units, a
ground male plug must be supplied at the installation of
the booster pump.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood or
if in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Do not use an extension cord or an adapter plug with this
equipment.
Figure 1
3 of 32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
INSTALLING TO A WALL
1. Locate the six (6) 5/16" lag screws and the mounting
bracket.
2. Mount the J-channel to the wall, by using three (3)
screws (provided).
NOTE: Screws must be located in a stud. If mounting to
concrete wall, proper hardware (not provided) must be
used.
3. Mount the booster panel on the wall by raising the
top of the panel over the J-channel. Place the panel
against wall and slide the panel down until it catches
on the J-channel. Mount the bottom of the panel to
the wall by using the remaining two (2) screws (refer to
Figure2).
4. Attach a 1/2" ID water inlet line to the inlet fitting
by using the 1/2" flare elbow with nut and clamp
provided. Then attach another 1/2" ID line to the water
outlet by using the remaining 1/2" flare elbow with nut
and clamp (refer to Figure2).
5. Turn on the main water supply to the booster assembly.
NOTE: Outlet pressure of this assembly is not regulated. A
regulator may be required for certain applications.
6. Plug the power cord into the wall receptacle. The
pump will not begin to run until low water pressure
circuit times out. When the pump cycles off, the
gauge should read 0.586 MPa (5.86 bar) (85 psi). Bleed
off water flow until pressure drops to approximately
0.448 MPa (4.48 bar) (65 psi). The pump motor
should begin to run, then turn off when pressure
reaches 0.586 MPa (5.86 bar) (85 psi). If not, there are
instructions on the inside of the pressure switch cover
for pressure switch adjustment.
Booster Splash
Guard
J-Channel
Mounting Bracket
Power Cord
#27 Water Inlet
(1/2" Male Flare)
#27 Water Outlet
(1/2" Male Flare)
Mounting
Wall
Water
Booster
Pump
Mounting Screws
Figure 2
4of32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
INSTALLING TO A SUPPORT STAND
NOTE: This water booster pump can either be mounted
to the side or on the inside of the support stand. The
method of mounting is the same for either application. The
following instructions cover the side mounting. This stand
is factory assembled to mount the water booster pump on
the left-hand side of the support stand. However, the water
booster can be mounted on the right-hand side by moving
the channel to that side.
,
Caution
If the system has a plate style water filter, it MUST be
mounted to the right-hand side.
1. Locate the mounting hardware supplied with the
support stand: three (3) 1/4"-20 x 1/2" carriage bolts,
two (2) 1/4"-20 x 1/2" hex screws (not supplied), five
(5) 1/4"-20 locking nuts, and the J-channel mounting
plate, (supplied with the water booster). The J-channel
mounting plate will later be mounted to the water
booster pump.
2. With the hook end of the J-channel towards the floor,
mount the channel to the top portion on the side of
the stand.
3. Fasten the channel with three (3) 1/4"-20 x 1/2" carriage
bolts and 1/4"-20 locking nuts. Tighten all bolts
completely.
4. By lifting the back edge of the panel above the channel
and hooking it on the lower edge of the J-channel,
place the water booster pump panel on the J-channel.
5. Attach the lower edge of the water booster pump
panel to the channel on the support stand with two
(2) 1/4"-20 x 1/2" hex screws and 1/4"-20 locking nuts.
Tighten the screws and nuts completely.
6. Complete the remaining installation using the
instructions supplied with the water booster pump.
NOTE: Installer must fit/install a back flow prevention device
compliant with local water regulations in incoming water
supply line.
Booster
Splash Guard
J-Channel
Mounting
Bracket
Model WBK10X
Water Booster
Pump
Multiplex
Support
Stand
Mounting Screws & Nuts
(supplied with support stand)
Figure 3
BEFORE INSTALLING THE WATER BOOSTER PUMP
Incoming
Water
Supply
Coarse
Filter
Filter
Accumulator Tank
(optional)
Regulator
0.379 MPa
(3.79 bar)
(55 psi)
Beverage Unit
To
Dispenser
Figure 4
AFTER INSTALLING THE WATER BOOSTER PUMP
Beverage Unit
To
Dispenser
Water
Booster
Pump
Regulator
0.379 MPa
(3.79 bar)
(55 psi)
Accumulator Tank
(optional)
Filter
Coarse
Filter
Backflow
Preventer
Incoming
Water
Supply
Figure 5
5 of 32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
Operation
1. Before applying supply water pressure, verify with air
gauge that the bladder pressure (Schrader valve) is
charged to 0.414 MPa (4.14 bar) (60 psi).
2. Turn water supply on, then plug unit into supply power
outlet/mains electrical supply.
3. Verify unit pump comes on and pumps up to 0.586 MPa
(5.86 bar) (85 psi) and then pump goes off.
4. Verify unit pump comes on at 0.448 MPa (4.48 bar)
(65 psi), by expelling water from system.
Annual Cleaning (Trained Service Technician)
A. Isolate or disconnect unit from power source/
mains electrical supply.
B. Remove exterior debris or dirt from unit or its
components using a vacuum cleaner, soft bristle
brush or a nonabrasive towel/rag.
C. Check all electrical connections for condition and
water connections for leaks to ensure safety during
operation. If any issues are found then repairs are
needed before unit can be put back into operation.
D. Reconnect unit to power source/mains electrical
supply.
,
Caution
Before shipping, storing, or relocating this unit, system
must be vented of pressure, drained and cleaned.
n
Warning
If left in a freezing environment with residual water inside
unit/system damage will occur to internal components.
Important
Welbilt recommends that for countries with non-
chlorinated potable water supplies, cleaning of the potable
water supplies should be performed on a 90-day time
interval, or more regularly if required by local legislation.
Cleaning or disinfecting should be performed by using an
environmentally friendly and approved chlorine detergent.
The approved chlorine detergent solution should be
injected into water supply line(s) after any in-line water
filtration systems and flushed through this equipment
to the point of dispense. Thorough flushing through of
the equipment with potable water following cleaning to
ensure no residual chemicals are left in the system.
Tools required for Maintenance or Repair
A. 1/4" (7mm) socket or nut driver
B. 5/16" (8mm) socket or nut driver
C. Standard or Straight Blade Screwdriver
D. Phillips Head Screwdriver
Max Noise dB(A)
Noise emission from this model does not exceed 70 dB(A).
29 of 32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
WBK10X Exploded View
31 of 32
PartNumber02000683004/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump
Declaration of Conformity
MULTIPLEX
2100 FUTURE DR, SELLERSBURG, IN 47172
800-367-4233
WWW.WELBILT.COM
©2017WelbiltInc.Exceptwhereexplicitlystatedotherwise.Allrightsreserved.Connuingproductimprovementmaynecessitatechangeofspecicaonswithoutnoce.
PartNumber02000683004/23/2018
Welbilt provides the world’s top chefs, and premier chain operators or growing independents with industry leading equipment and soluons.
Our cung-edge designs and lean manufacturing taccs are powered by deep knowledge, operator insights, and culinary experse.
All of our products are backed by KitchenCare® – our aermarket, repair, and parts service.
CLEVELAND
CONVOTHERM®
DELFIELD®
FITKITCHEN™
FRYMASTER®
GARLAND
KOLPAK®
LINCOLN
MANITOWOC®
MERCO®
MERRYCHEF®
MULTIPLEX®
WWW.WELBILT.COM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

MULTIPLEX WBK10X Water Booster Pump 00216382 Owner Instruction Manual

Type
Owner Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI