All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
Microwave/RNO Wall Oven/
Warming Drawer
Document # PGCI-037
Revised 02/04/15 Page 1/1
CUTOUT DIMENSIONS
DMW2420 SHOWN (ADMWTK TRIM KIT)
CUTOUT DIMENSIONS
DCM24 SHOWN (ADCMTK TRIM KIT)
Wall Oven Models (B) Cutout Width
Single 27” 25 1/2” (64.8 cm)
Single 30” 28 1/2” (72.4 cm)
Microwave Trim Kit (A) Cutout Width
ADCMTK27 25 3/4” (65.4 cm)
ADCMTK30 28 1/4” (71.8 cm)
ADMWTK27 25 3/4” (65.4 cm)
ADMWTK30 28 1/4” (71.8 cm)
Warming Drawer Models (C) Cutout Width
27” 25 1/2” (64.8 cm)
30”
28 1/2” (72.4 cm)
NOTE:
1. 3/4” (1.9 cm) support platform (flush with cutout).
2. See individual appliance Planning Guide pages to
determine overlays.
3. Spacing between appliances and drawers/doors shown
is minimum required to allow for ventilation and prevent
scraping. Additional space may need to be added for
appearance.
4. Warming drawer model OWD24 is not approved for
installation above, below or adjacent to a wall oven or
another warming drawer (any type).
9 1/8”
(23.2 cm)
27 1/2”
(69.9 cm)
16 3/4”
(42.5 cm)
7/8”
(2.2 cm)
min.
1 1/2”
(3.8 cm)
min.
B
C
A
120 Vac electrical
outlet for microwave
120 Vac electrical
drawer
240 Vac
wall oven
junction box
1
1
1
5/8” min. (1.6 cm)
3/4”
(1.9 cm)
min.
57 1/8”
min.
(145.1 cm)
overall
stacked
height
outlet for warming
9 1/8"
(23.2 cm)
27 1/2"
(69.9 cm)
1" min.
(2.5 cm)
1 1/2" min.
(3.8 cm)
B
A
1
1
1
3/4" min. (1.9 cm)
3/4" min.
(1.9 cm)
59 3/4"
min.
(151.8 cm)
overall
stacked
height
C
19 1/8"
(48.6 cm)
120 Vac electrical
outlet for microwave
120 Vac electrical
drawer
240 Vac
wall oven
junction box
outlet for warming
All tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
WARNING
• Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
• All appliances must be installed in accordance with the
accompanying installation instructions.