Anviz T50 Quick start guide

Category
Security door controllers
Type
Quick start guide
Other Setup
Keypad Instruction:
C/
3
6
9
2
5
8
1
4
7
OK/M
0/
Operation Guide
Press the ‘Reset’ button at the buttom of the device until LCD go out.
Now release the button the device will restart.
Reset: Restarts Device
Management password setup: Press [0/→] to select [SET.] option: Change management password.
Setup Date and Time: Press [0/→] to select [TIME] option: Set time and date.
LCD
Fingerprint Sensor
Add User:
Management mode: In original state, press [OK/M] then enter the admin password (Default password12345) to the management mode.
Notice: Resetting will not delete any information or settings stored
in the device.
Always place finger in the center of the sensor. Make sure you cover the entire sensor surface
with as much of your finger as possible.
Do not place finger away from
the center of the sensor window.
Do not place finger
at an angle.
Correct method (Straighten your finger and then place it on the sensor ensuring the finger is down flat and covers the entire sensor windows ) :
Incorrect method :
Do not slide your finger during the
fingerpint verification process.
Do not take off finger during the
fingerprint verification process.
Do not use just
your fingertip.
Illustration for placing finger
Reader Appearance
Press [OK/M]Press [OK/M] Press [OK/M]
SET
Input Date: YY-MM-DD
Set TimeHH-MM-SS
Press [OK/M]
Please Input password again
Press [OK/M]
SET
Reset Button
Initialization Button
To initialize the device and reset the management password back to the default
password (12345) press the ‘Initialization Button’ until heard beeps. The operation
will not delete any user data stored in the device.
Initialization: Return password to factory defaults
Remarks: If register fails, the device will
give a long ‘Beep’ voice to prompt. If the
fingerprint has already been registered
the device give two ‘beeps’ and voice
prompts for the fingerprint process to be
repeated.
Press0/→to
select FP1, FP2 or PW
Communication with PC
V1.3
Press[OK/M]
Management menu
Press [OK/M]
SET
Press [OK/M]
Press [OK/M]
SET
Input User ID to be deleted
Press [OK/M]
Delete User: Press [0/→] key select [DEL.] option.
Door Bell Key
Cancel/Power Key
Exit/Cancel the Current
Operation
Power on/Power off
Confirm/Menu Key
Confirm Current Operation
Enter System Management Menu
Num. Keys
Enter Employee ID or Password
1-9
OK/M
0/
: Select Key
Do not move your finger before
the backlight of sensor turns off.
Press [OK/M]
Press [OK/M]
Press [OK/M]
The min&max password length is 1 to 6 digits
Press [OK/M]Press [OK/M]
SET
Enter User ID
Press [OK/M]
Place same finger twice on the sensor Registration Successful
Press [OK/M]
Place same finger twice on the sensor
Registration Successful
Input user password
Please input password again
RS485
Mini-USB
TCP/IP
RJ45
Default password:12345
Press [OK/M]
Remarks: If the second password does not
match the first. When you press
the device will give long beeps to indicate
the password changing has failed.
OK/M
Input new management password
7 8 9
OK/M
1 2 3 c/
4 5 6 0/
144 mm
74 mm 40 mm
Port
PIN
2 1 6 5 4 3 2 1
Function
Connector
GND D1 D0
Connector
Connector
Wiegand Output
P2P1
Switch Power Supply
Switch Power Supply
Access Controller
Port
PIN
2 1 8 7 6 5 4 3 2 1
Function
GND
GNDNO NC COM
Exit
Button
Door
Sensor
Connector
OPEN DOOR
Mark
PUSH NO GND NC
Output Controller
P1 P3
Power off to unlock
Power on
to unlock
Access Control Power Supply
+
+
+
+
Door Sensor
Power Supply
Power Supply
Important notice: Please carefully follow this wiring diagram, If the reader gets damaged by
incorrect wiring then your warranty will be void.
Relay State
12VCOM
Wiring Instruction
Access Control Reader & Controller
Access Control Reader & Power Supply
Access Control Reader & Switch Power Supply
Waterproof Cover Installation
RS485ARS485B
RS485
GND GND D1 D0
P
1
PIN DescriptionFunction
Power
1
2 Red DC12V
Black GND
P
4
PIN
Cable
Color
Description
Function
Door Bell
1
2
Trigger Output
Trigger Output
Purple Trigger Input
Trigger InputYellow
White
White
Black
Green
Orange
Blue
P
3
PIN
Cable
Color
DescriptionFunction
Door Sensor
GND
Relay
Exit Button
1
2
3
4
5
6
7
8
GND
COM
NC/DC12V
NO/DC12V
P
2
PIN
Cable
Color
DescriptionFunction
Wiegand
Output
1
2
3
4
5
6 Black
Purple
Yellow
Black
White
GND
GND
Wiegand DATA0 Output
Wiegand DATA1 Output
Green
RS485
RS485A
RS485B
P
1
P
2
P
3
P
4
Relay State
Relay
6
7
8
COM
NC
NO
P3
P3
Relay
6
7
8
COM
DC12V
DC12V
12V COM
12V COM
TCP/IP
Installation Steps:
1
2
3
Drill holes in the wall follow the hole position on back panel
Install and fix back panel, connect related cables
Fix access control reader
Installation Diagram
1
Reader
7 8 9
OK/M
1 2 3 c/
4 5 6 0/
12V
COM
Relay State
Instruction Package
⢯ࡡ䈪᱄φ䰞⾷ᵰᱥ儎ᓜ䳼ᡆौⲺ㋴ᇼ⭫ᆆӝ૷θԱ֋䭏䈥Ⲻ䘔᧛䜳ਥ㜳ሲ㠪
䰞⾷ᵰⲺݹಞԬᦕඅθഖ↚䘔᧛਺〃䇴༽ҁࢃθ䈭Ԋ㓼䰻䈱᧛㓵䈪᱄Ⱦ
݌িપޢ
ѽ ߑ
P
1
ি ோ਩ ݔଚԅਈ
ऄ࢛
1
2
ঠ঱ ऄ࢛
DC12V
ঠ௲
GND
P
4
ি ோ਩ ݔଚԅਈ
୹ୟ
1
2
ઇՇ૿ӟ
ઇՇ૿ӟ
ઇՇ૿ҵ
ઇՇ૿ҵ
P
3
ি ோ਩ ݔଚԅਈ
୹्
ݎ֪
৐ऄ֘
ӟ୹ܷ୚
1
2
3
4
5
6
7
8
GND
COM
NC/DC12V
NO/DC12V
P
2
ি ோ਩ ݔଚԅਈ
ஷ߿૿ӟ
1
2
3
4
5
6
GND
GND
ஷ߿
DATA0
૿ӟ
ஷ߿
DATA1
૿ӟ
RS485
RS485A
RS485B
P
1
P
2
P
3
P
4
⭫ಞ⣬
৐ऄ֘
6
7
8
COM
NC
NO
P3
P3
৐ऄ֘
6
7
8
COM
DC12V
DC12V
12VCOM
12VCOM
TCP/IP
؍੸࠵௢
1
2
3
1
2
3
؍੸ॐ۞֣
୆ўԕ
ރ݇ি
P1 P2 P3
P4
1
Пфս
2
૏މԕ
COMPACT
CD-ROM
EN
CH
Copyright ANVIZ All rights reserved.
http://www.anviz.com
windows
FOR
Windows 98
Windows 2000
Windows XP
Windows Vista
Windows 7
੸ঔࢎԥ
7 8 9
OK/M
1 2 3 c/
4 5 6 0/
COMPACT
CD-ROM
EN CH
windows
FOR
Windows 98
Windows 2000
Windows XP
Windows Vista
Windows 7
Access control
Accessory Package
Cable
Color
Select either
12 volt out on
COM or voltage
free contact.
Package list
Exit
Button
GNDNO NC COM OPEN DOOR
Output Controller
Port
PIN
2 1 8 7 6 5 4 3 2 1
Function
GND
Door
Sensor
Connector
Connector
Power Supply
P 3P1
Power off to unlock
Power on to unlock
+
+
+
Door Sensor
Diode
Diode
V1.3
1
2
3
Connector Jack
RJ45 USBP1 P2 P3
P4
Step1: There is a plate at the back of the T50 device. Please remover it before
install the waterproof cover.
Step2: Install the waterproof cover replace the plate on the T50 device and fix back plate
with 4 screws so that the waterproof can be slide up and down and fixed the T50
front plate on the back plate board.
  • Page 1 1
  • Page 2 2

Anviz T50 Quick start guide

Category
Security door controllers
Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI