Anviz T60 Quick start guide

Type
Quick start guide
35
200
200
90
Reader Appearance
Fingerprint Access control
Front View
Side View
Menu List
Press [M] key to enter system management menu.
(This requires the administrator authorization if there is admin
registered in the system.) Menu List:
Operation Guide
Other Setup
Tips: Group setup is used for managing the access control privileges. Each
group can contain 4 time zones.
Explanation
G01
Item
Factory default
setting
G00
G01
G02-16
The user in Group00 can not open the door
The user in Group01 can open the door anytime
It is according to the Group & Time zone setting which
can be set through the software
Group Setup:
Tips: It doesn’t allow duplicate Device ID in one LAN. Otherwise, it will
cause software communication error. Then ID as “NULL” must adopts
last 8 digit of the serial number for software communication.
Explanation
1
Item
Factory default
setting
NULL-99999999
Device ID of the unit which is required in software
communication
Dev ID:
Explanation
Related Language
Item
Factory default
setting
Languages
Contains 11 languages:
ENG(English), FRCH(French), GERM(German), SPAN(Spanish),
PTG(Portuguese),ITA(Italian) BULG(Bulgarian), SLVK(Slovak),
HUNG(Hungarian),SLVN(Slovenian), TURK(Turkish)
Language:
Item Explanation
Factory default
setting
Any
RF+PW
RF+FP
PW+FP
Fingerprint only, Card only or ID+Password only
It requires both Card and Password verification
together
It requires both Card and Fingerprint verification
together
It requires both Password and Fingerprint verification
together
Enter the user ID first then verify the fingerprint
Any
ID+FP
Verify Mode:
Explanation
5
Item
Factory default
setting
1-15
The duration of the audible alarm to notify employees
of events. (Lunch, break, Off Duty)
No
It generates a door close signal immediately after
it generates the door open signal
Unlock:
15
No
Explanation
Disable the door open alarm
Factory default
setting
It generates the door open alarm signal if the door open
time is longer than the preset value
Item
1-99
Door Alert:
Tips: WorkCode indicates the work typeeasily distinguishes which
attendance record is related to which work type.
Explanation
Max 999999
Min 0
Item
Factory default
setting
0-999999
Valid scope for the Workcode
WorkCode:
ExplanationItem
Factory default
setting
Server Mode
192.168.0.218
255.255.255.0
192.168.0.1
192.168.0.7
5010
Mode
IP Address
Subnet Mask
MAC Address
Gateway IP
Server IP
Server Port
Net:
TCP/IP Server mode: Common network mode
TCP/IP Client mode: Only communicate
with the PC which has static IP
Set terminal IP address when communication
of TCP/IP, IP address
must be a static
IP address
Subnet Mask of the LAN
Unique Physical address of the network moudle. This
setting can not be modified.
Default Gateway of the LAN
The IP address of the Sever Machine
when using Client Mode TCP/IP
communication.
It’s the Software Port number used when the
read is configured for TCP/IP communication
Place finger on the sensor surface
Place finger in the center of the sensor.
Illustration for placing fingerprint
Place finger straight and
flat on the sensor. Insure
maximum sensor coverage.
Menu Key
Enter System Management Menu
M
State Key(Clock In)/Up
State Key(Clock Out)/Down
Door Bell Key
Confirm Key
Confirm Present Operation
OK
0-9
Num. Keys
Enter Employee ID or Password
Exit/Cancel the Present
Operation
Workcode
C
Volume
Ring
Door Alert
User
System Info
User, FP, Log, Serial,FirmVer
Enroll
Delete
Admin Setup
Admin Clear
Setup
Hardware Test
Keypad, LCD,Voice, Sensor, Flash
System
Time
Language
Net
Precision
Auto Off
Auto Update
Image Disp.
Log Setup
Log Alert
Re-Verify
Verify Mode
Group Setup
IP Address
Subnet Mask
Gateway IP
MAC Address
Workcode Scope
Dev ID
Unlock
Mode
Server Port
Server IP
Local Port
Daylight Saving
(ID:000001-999999)
Enroll User: Each user can register two fingerprints, one password and one RFID card.
1
Enroll
ID 008101
Esc-C Set-OK
IN
09 : 00
26
10-11-17 WED
MENU
User
Setup
USB Flash
User
Enroll
Delete
Verify Mode
[M]
Select [User]
[OK]
Select [Enroll]
[OK]
Input user ID
Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of
two administrators to each unit.
2
Admin Setup
ID 008101
Esc-C Add-OK
Admin Setup
008101
No-C Yes-OK
Admin Setup
Esc-C Add-OK
Admin Setup
ID
000000
MENU
User
Setup
USB Flash
User
Admin Setup
Group Setup
Admin Clear
Select [User]
[OK]
Selelct [Admin Setup]
[OK] [OK] [OK] [OK]
Setup successfulInput Admin ID
Enroll FP
Enroll FP
Enroll FP
Enroll Card
Enroll Card
Enroll Card
Swipe card!
008101-C
Cancel-C Sav-OK
Enroll
FP 1/2
Password/ Card
Esc-C Set-OK
Select [Card] Swipe the card Press [OK] to save
[OK]
press [OK]
Enroll Card
Enroll Password:
Password length: 000000-999999
.
Enroll PWD
PWDID
******
Esc-C Set-OK
Input password
008101-P
Cancel-C Sav-OK
Press [OK] to save
PWDID
******
Confm
******
Input password again
[OK] [OK] [OK]
Enroll
FP 1/2
Password /Card
Esc-C Set-OK
Select [Password]
press [OK]
Enroll PWD
Enroll PWD
Enroll Fingerprint:
Place the same finger on the sensor twice in a row to enroll fingerprints.
008101-1
Sav-OK
Press [OK] to save
Take Off! Place Finger #2
Enroll FP
Enroll FP
Place Finger #1
Enroll fingerprint
[OK]
Enroll
1/2
Password/Card
Esc-C Set-OK
FP
Select [FP]
press [OK]
V1.1
Relay Status 1
DC12V
GND
COM2
NC2/DC12V
NO2/DC12V
GND
COM1
NC1/DC12V
NO1/DC12V
GND
GND
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
10
P1
5
6
7
8
GND
GND
RS485(B-)
RS485(A+)
描述
1
2
3
4
P2
Important notice: Please follow the wiring
diagram as it is displayed. Damaged products
due to improper wiring are not covered under
the product warranty.
+12V
WGin1
WGin0
GND
GND
WGout1
WGout0
RS485B
RS485A
GND
COM2
NC2
NO2
GND
COM1
NC1
NO1
BE1
BE2
GND
OPEN
DOOR
LOCK
GND
TCP/IP
1 2 1 2 3 4 5
+12V GND
+12V GND
P2P1
TCP/IP
Mini USB
1
2
3
P2
P1
DC12V
NC1
NO1
+
+
+
Exit
12V
GND COM1 NC1 NO1 GND COM2 NC2 NO2 GND BE1 BE2
DOOR LOCK
Mark
12V
GND PUSH NO GN
D
NC
Exit
+
+
+
12V
GND COM1 NC1 NO1 GND COM2 NC2 NO2 GND BE1
P1
Mark
12V GND
Relay1 use for direct lock control, relay2
only for schedule bell.
Relay1 use for direct lock control, relay2
only for schedule bell.
1
Card
Reader
COMPACT
CD OM
EN CH
windows
FOR
Windows 98
Windows 2000
Windows XP
Windows Vista
Windows 7
2
Instruction Package
Accessory Package
Connector Jack
Installation Step
1
Drill holes in the wall follow the hole position on back panel
2
Install and fix back panel, connect related cables
3
Attach access control reader
Relay Status 2
PIN
Function Description
PIN
Function Description
Relay2
Relay1
Lock Status
GND
Door Sensor
Exit Button
GND
GND
Door Bell
Power
Trigger Output
Trigger Output
Trigger Input
Trigger Input
Trigger Input
RS485
Wiegand
Input
Wiegand
Output
GND
Wiegand DATA1 Input
Wiegand DATA0 Input
Wiegand DATA1 Output
Wiegand DATA0 Output
Package List
Installation Diagram
Wiring Instruction
Access Control Reader & Power Supply
Access Control Reader & Switch Power Supply
Access Control Reader & Controller
Communication with PC
Port
PIN
Function
Connector
Port
PIN
Function
Connector
Connect with
lock status signal
Alarm/Bell
Door Bell
Door Open Sensor
Power On to Unlock
Power Off to Unlock
Access Control
Power Supply
12V
COM
Relay 1 status
12V
COM
Relay 2 status
Relay 2 status
The relay 2 work
as this status the
alarm need
additional power.
Please make sure
the alarm work power.
The relay 2 work
as this status will
provide DC12V to
alarm.
12V
COM
12V
COM
Relay 1 status
12V
COM
Relay 2 status
Relay 2 status
The relay 2 work
as this status the
alarm need
additional power.
Please make sure
the alarm work power.
The relay 2 work
as this status will
provide DC12V to
alarm.
12V
COM
Connect with
lock status signal
Alarm/Bell
Door Bell
Power Off to Unlock
Power On to Unlock
Diode
Diode
Doo Open Sensor
Switch Power Supply
Port
PIN
Function
Connector
Power
Supply
Relay1
GND GND
GND
Relay2
Door Bell
Lock
Status
Wiegand Card Reader
Access ControllerSwitch Power Supply
Mark
Relay 1
7
8
9
COM1
NC1
NO1
P1
P1
Relay 1
7
8
9
12V
COM
12V
COM
The relay2 status setting as same as relay1
V1.1
  • Page 1 1
  • Page 2 2

Anviz T60 Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI