  • Hello, I have reviewed the CRX3108 Firmware Upgrade Instructions. This document provides detailed guidance on preparing an SD card, using the OSD menu, accessing system settings, and initiating the firmware update process. I am ready to assist with your questions about the device and its firmware update.
  • What is the first step for a firmware upgrade?
    Is an LCD screen required to upgrade the firmware?
    What should I do if power is disconnected during the update?
    What to do if CRXS doesn't have a password defined?
    What should I do if the device uses SIM and connected service?
1
CRXS Firmware Upgarde
Instructions
V 1.0
Note: If you're using CRXS with a SIM and connected service, please consult your
telematics provider or Sensata INSIGHTS before attempting to update your device
firmware. In this case, the firmware update can be much more easily applied to your
device using SmartAPI over-the-air update service.
Model #: CRX3108
2
CRXS Front Panel Keys
1. SD Card Preparation
a. Insert the SD card into PC.
b. Open the SD card root folder.
c. Copy firmware file into SD card root folder.
d. Safely eject the SD card from your PC.
2. CRXS Firmware Update
CRXS firmware upgrade requires an LCD screen in order to access the OSD menu
and monitor the firmware update progress.
SD card must be inserted into the SD slot and the latch should be closed.
Power on the CRXS. Navigate through the OSD menu via the front panel buttons.
3
Click on Menu button.
Navigate through the OSD Menu via the arrow buttons [<], [>], [], [v].
In order to apply the new firmware, navigate to System tab.
Select Service Menu option.
Select Run for Maintenance field.
Note: By pressing the Menu button a new window will open up indicating that a
password needs to be inserted. If the CRXS doesn’t have a password, you may click
on Menu button again in order to access the main options provided.
OSD Menu - Device
OSD Menu - System
OSD Menu Service Menu
4
Select Upgrade and choose the firmware source.
Confirm Firmware version.
Maintenance FW Upgrade
Note: CRXS will reboot once the firmware update is completed. Power should not
be disconnected in order to have a healthy system update. If this happens, please
contact your supplier.
/