PACOM PC868. Infrared Thermometer User manual

Category
Digital body thermometers
Type
User manual

This manual is also suitable for

Please read this manual before use!
B
ody Infrared Thermometer
User's Manual
1. Summary of Infrared Thermometer
2. Safety precautions
Thank you for choosing our Infrared Thermometer. The PC868
Infrared Thermometer is used to measure an objects temperature
based on the relationship between temperature and measurable
infrared radiation. Simply aim the unit’s probe toward the surface
to be measured to obtain a quick and accurate temperature.
To ensure proper use, please be sure to read this user manual
carefully, paying close attention to the safety precautions.
In order to use this product correctly, please read the user
manual before use.
In order to properly use this product, please carefully read the
full text of this manual before using, in particular the “safety
precautions” section.
Please keep the instructions on the side for easy checking.
Basic principles:
All objects above absolute zero temperature emits certain
percentage of infrared radiation energy based on its temperature.
The amount of the radiation energy and the distribution of the
wavelength have very closely relationship. When human foreheads
temperature in 36-37℃, it emits wavelength 9-13um of infrared
radiation. Based on this principle, according to the relationship
between surface forehead temperature and human foreheads
temperature, we are able to measure the human forehead’s actual
temperature through measuring surface forehead temperature.
Warning
Use of this thermometer is not intended as a substitute for
consultation with your physician. It is dangerous for user to
perform a self-evaluation and self-treatment based on the
measuring result. Be sure to follow doctor’s instruction.
Keep the thermometer out of reach of children. For accidental
swallow of battery or other component, please consult the doctor
at once.
Don’t throw the battery into fire.
- 1 -
Notice
The device is precision instrument, don’t drop, tramp or impose
any vibration or impact on the thermometer.
Do not touch the lens of the probe with your fingers, and do not
dissemble the device by yourself.
Before measuring forehead temperature, make sure the hair
re-moved, sweat dried.
After you do some exercise, eating and bathing, you should stay
still indoor about 30 minutes before measurement.
To make the measurement data reliable and stable, when
ambient temperature varies a lot, the thermometer should be
placed indoors for about 30 minutes before using.
When we measure somebody continuously, the temperature
should be measured every minute, if you need to measure yourself
Continuously for a short time, there are some slight errors when
you read the temperature ,which is a normal phenomenon. At this
time, we should choose the average. We recommend that you
measure yourself continuously maximum of three in a unit of time,
and because the temperature of the human will conduct to the
thermometer, it may affect the accuracy of measurement.
There is no absolute standard about the temperature of the
human, so please try to collect the recording of Individual
temperature in the usual, as a reference for having a fever or not.
Do not measure the sites of scarred tissue or tissue compromised
by skin disorders, because sensing body temperature from sites of
scarred tissue or tissue compromised by skin disorders.
Do not measure the site of forehead temperature if that patients
has trauma on forehead.
Do not measure if that patient is treated with certain drug
therapies.
Do not immerse the device into water or any other liquid, and not
directly sunlight exposure.
Do not use a mobile or mobile or cordless hone near the
thermometer when measuring.
Body temperature may increase in the drug within the effort time
limit. Please don’t measure.
- 2 -
3. Intended use
1) Don’t use this thermometer for other purposes.
2) It is forbidden to leave the product exposed to any chemical
solvent, direct sunshine or high temperature.
3) Don’t expose the thermometer under direct sunlight long time
so as not to damaged the battery.
4) Do not measure while talking on the phone.
5) Please report to MANUFACTURER if any unexpected operation or
events occur.
This thermometer is intended with non-contact to measurement
forehead temperature at home or hospital, including anyone, such
as infants, children and adults.
For the safety reason, children or the baby’s temperature must be
measured by parent or adults.
In order to ensure the accuracy of measurement data, please
don’t take measurement of body temperature in strong electro-
magnetic interference environment (such as microwave, high
frequency equipment operation environment).
Do not disassemble, repair, or modify the unit.
This thermometer only a personal device, please do not user with
others.
Not touch the battery output when measuring.
The thermometer must be stored according to the technical
specifications.
The materials (ABS) of expect contact with patient had passed
the ISO 10993-5 and ISO 10993-10 standard test, no toxicity, allergy
and irritation reaction. The are compliance with the MDD require-
ments. Based on the current science and technology, other
potential allergic reactions are unknown.
The patent is an intended operator. The patient can measure,
read data and replace battery under normal circumstances and
maintain the device and its accessories according to the user
manual.
The device is not intended for PATIENT transport outside a
healthcare facility.
Recommendations
- 3 -
NOTE: The normal temperature and difference between the
different body parts is individual. The define yours, measure your
temperature for a least 2 weeks at the same ear canal, forehead
position and time.
NOTE: When consulting your physician, communicate that the
infrared thermometer PC868 temperature is a temperature
measured which position, note the individual’s normal infrared
thermometer PC868 temperature range as additional reference.
NOTE: Because the forehead temperature is affected obviously by
the external environment (eg: environment, air convection and skin
tone, etc),we advice that you take the forehead temperature only as
reference.
4. Temperature measurement mode
and range description
The infrared thermometer has the following measurement mode:
1) Forehead temperature measurement mode -- measure the skin
surface of human forehead’s temperature accurately, take the place
of traditional mercury thermometer and electrical thermometer.
2) Object temperature measurement mode you can measure the
surface temperature of object, such as ambient, bathwater and milk
temperature etc.
Normal temperature range for different measuring position
Normal forehead temperature range for different ages
Measuring position
Normal temperature ()
Normal temperature ()
Anus
36.6-38.0
97.9-100.4
Oral
35.5-37.5
95.9-99.5
Armpit
34.7-37.3
94.5-99.1
Forehead
35.8-38.0
96.4-100.4
Ages
Normal temperature ()
Normal temperature ()
0-2 years old
36.4-38.0
97.5-100.4
3-10 years old
36.1-37.8
97.0-100.0
11-65 years old
35.9-37.6
96.6-99.7
65 years old
35.8-37.5
96.4-99.5
- 4 -
5. Feature
Precise non-contact measurements
User selectable ℃ or
Set alarm temperature value
Automatic data hold and auto power save
Automatic selection range and display resolution 0.1℃ (0.1℉)
3 colors backlight
2 measurement mode: Forehead and surface mode
1. IR sensor
3. Mode selection
5. UP button
7. Measurement Trigger
2. LCD display
4. Down button
6. Mode button
8. Battery cover
6. Overall description
- 5 -
【LCD display description
7. Operation Instruction
【Preparation】
1) Check battery
Replace the batteries to ensure power supply if there is low voltage
icon for the thermometer.
2) Check sensor
If have pollution and spray, please clean it. (The cleaning method
see the chapter 8 Care and Cleaning for detailed.)
If the sensor’s lens is damaged, please stop using.
3) Check thermometer
When you press the [Power/Scan] button, the system will have self
testing of software and hardware. If there are problems, LCD will
display "Err" symbol. Check if the sensor laser is dirty, damaged
phenomenon.
4) In order to make the accurate measuring result, put the
thermometer in the measurement environment for 30 minutes.
5) Accuracy of unexpected fluctuations in ambient temperature
may decrease the measurement results. When the thermometer at
the same measurement position display at different ambient
temperature, or test temperature in front of the air conditioner, it
will not be able to obtain accurate results.
6) If you want measure forehead temperature, clean forehead and
arrange hair, make sure the forehead is naked and clean, in order to
ensure the accuracy of measurement.
- 6 -
2. For the first use or when inserting new batteries, please wait
about 10 minutes for the warm-up of the apparatus.
3. If the device is not used for a long time, once you turn it on
again, the device will test the room temperature first and will delay
turning on for one or two seconds.
4. Select body mode, aim towards the forehead, form distance of
5cm(2in), press the measuring key, the temperature is displayed
immediately, accompanied by a beep sound. Making sure there is
no hair, perspiration, cosmetic or cap covered on the forehead.
1) Advice for the first use
For stable and reliable results, it is essential to check the infrared
thermometer and changes as needed, as follows:
2 )U s e
1. Install batteries
【Instruction for use】
1
st
step: Take the temperature of a person using a conventional thermometer, you will get 37.5
(99.5) for instance.
2
nd
step: Take the temperature of the same person using the device keeping the 3 to 5cm distance
between the thermometer and forehead (take care to remove any obstacle which could
alter the measurement (hair, perspiration ….). If you get 37.5 (99.5 ), the device is
properly set and ready for use.
If you get a lower temperature such as 36.4(97.5), your difference is 1.1(2.2). You
should adjust
the temperature on the device and add the difference, i.e.1.1 (2.2).
To do it, press the MODE button for 2 seconds, the screen displays F1, press MODE button
again until you get F3, press UP button in order to add the difference (in our example 1.1
3
rd
step:
- 7 -
5.If the measurement temperature is 38.0℃ or more (can be setting,
refer to sub-clause 3)), the sound should be “be-be-be-be-be” 5
repid sounds.
TEMPERATURE TAKING HINTS
-
Before take the temperature, please fix the forehead hair to prevent measure
d
deviation.
-
The sweat on head or cosmetic can affect the accuracy of measurement, pleas
e
maintain the cleanness of the forehead when measuring.
-
It is normal that there may be temperature difference depending on various skin type
s
and color, since different skin type will reflect different voltage of infrared ray.
- Don’t use the thermometer outdoors.
6. Select object mode for measuring room temperature, surface
temperature etc.
TEMPERATURE TAKING HINTS
-
For heat-insulated object, please don’t measure the surface.
-
For the hot liquid, please do not directly measure the surface, because the hot stea
m
fog can condense in the sensor lens and cause the measurement deviation.
- 8 -
3Setting operation
Mode code Function Operation step
1 F1 Set / scale Press MODE button for 2 seconds, the screen
will display F1 on the bottom right, press UP or
DOWN button can change temperature unit
for
or.
2 F2 Set alarm temp. Press MODE button for 2 seconds, the screen
display F1, press MODE button to get F2,
select UP to increase the threshold by 0.1
(0.1), DOWN to reduce it by
0.1
(0.1). The
alarm threshold default value is
38.0(100.4).
3 F3 Set difference Press MODE button for 2 seconds, the screen
display F1, press two times to get F3, select
UP to increase the difference by 0.1
(0.1),
DOWN to reduce it by
0.1(0.1). In the case of
seasonal or environmental changes a verification and
adjustment should be carried out.
Note: This function is only effective body.
4 F4 Set buzzer on/off Press MODE button for 2 seconds, the screen
display F1, press 3 times to get F4. Select UP
to turn on the buzzer, press DOWN to stop it.
- 9 -
5 Measurement mode There are 2 measurement modes for this
device. That is forehead, surface. It is able to
take the body temperature of human beings,
take the temperature of an area or an object, a
food, a liquid or a room.
Forehead
mode
Put the mode selection button on
the left, measurement range 32.0
to 43.0
(86.0 to 109.4).
Surface
mode
Put the mode selection button on
the right, measurement range 0 to
100
(32.0 to 212.0).
6 3 colors backlight In body mode, the device is able to judge
whether a fever or not by different color of
backlight:
32.0 to 37.4
(86.0 to 99.3) – Green
37.5 to 37.9(99.5 to 100.2) – Orange
38.0 to 43.0(100.4 to 109.4) – Red
In surface mode, the backlight always keeps
green.
7 Data memory Date memory automatically after temperature
measurements, which will display at the right
corner of LCD. Press UP or DOWN button to
display the last temperature measurement.
- 10 -
-- Range of alarm temperature
When into the “F-2 mode, the range of settable alarm tempera-
ture is from 37.6℃(99.7℉) to 43.0℃(109.4℉).
-- Range of temperature difference
When into the “F-3 mode, the range of settable temperature
difference is from 5℃(9℉) to -5℃(-9℉).
Note: F-3 mode is only for professional doctor and nurse use!
--Taking Temperature in Forehead Temperature Mode (Adjusted
Mode)
1. Setup the measurement mode to “Body mode” (the setup step
see the above “2) Function Setup mode”;
2. Make sure the distance between thermometer and forehead is
3-5cm, and press the button of [Power/Scan] directly to measure
the forehead temperature .
3. When you hear one beep sound, the LCD will show the result.
NOTE:
1. When measuring, if the environment exceed the 10-40℃ range
will be showing Err;
2. If the measured temperature result is < 32.0℃, the LCD will be
showing Lo;
3. If the measured temperature result is >43.0℃, the LCD will be
showing Hi;
4. If the measured temperature result is ≥38.0℃, the buzzer will be
send out “Beep—Beep—Beep”, a long one and two short ones.
5. We recommend measurement for 3 times to reference, and keep
the interval between the two measurements by 5 minutes at least.
4Temperature measuring
TEMPERATURE TAKING HINTS
- Before take the temperature, please fix the forehead
hair to prevent measured deviation.
- The sweat on head or cosmetic can affect the accuracy
of measurement, please maintain the cleanness of the
forehead when measuring.
- It is normal that there may be temperature difference
depending on various skin types and color, since different
skin type will reflect different voltage of infrared ray.
- Don’t use the thermometer outdoors.
- 11 -
--Taking Temperature in Surface Temperature Mode (Direct Mode)
1. Setup the measurement mode to “Surface mode” (the setup
step see the above 2) Function Setup mode”;
2. Aim the probe tip at the object which will be measured.
3. Press [Power/Scan] button, then the measurement completed.
It will show the measurement data after a “bi sound.
4. If the measured temperature is higher than 100℃ , display “Hi”.
If the measured temperature is below 0℃,display “Lo”.
5Automatic shutdown
If you do nothing after the temperature measurement completed
and 15 seconds later, the thermometer will automatically
shutdown.
6) Memory function
In the power-on state, press the Up/Down button into memory
query mode, the LCD will be showing the recorded values or “ ----
symbol if not record accompanied with memory M symbol. The
PC868 can restore up to 99 sets data. the query interface can
display memory serial number, body mode and recorded tempera-
ture values.
Remark: The temperature result of surface mode can not be saved.
And the abnormal body temperature result can not be saved too
(such as Lo, Err or Hi).
7) Backlight function
The backlight will be according to the different measuring
temperature to lighting different color. The detailed as below table:
TEMPERATURE TAKING HINTS
- For heat-insulated object, please don’t measure the
surface.
- For the hot liquid, please do not directly measure the
surface, because the hot steam fog can condense in the
sensor lens and cause the measurement deviation.
Measuring temperature
Backlight
Lighting time
< 37.5
Green backlight
7s
37.5 to 37.9
Orange backlight
7s
38.0
Red backlight
7s
Remarks: This specification of this table only for the factory default state. If the user into the setup
mode to setting the orange or red backing temperature, then will compliance with the setting result.
- 12 -
Notice:
Probe tip (lens) is a most precise part in the thermometer. Please
keep clean and entirety in order to assure the accuracy of figure.
The probe tip and lens are the most delicate part of the
thermometer. It has to be clean and intact to ensure accurate
readings.
If the thermometer is ever accidentally used clean the probe and
lens as follows:
Very gently wipe the surface with a cotton swab or soft cloth
moistened with alcohol. After the alcohol has completely dried out.
If the lens is damaged, contact the distributor.
Clean the unit body:
Use a soft, dry cloth to clean the thermometer display and unit
body.
If very dirty, use a soft with alcohol to cleaning.
8. Care and cleaning
8) Restore the factory default function
Press the [Setup] button for 5s to restore the factory default status.
The factory default setup is “℃ and “Body measurement mode.
9) Battery installment and replacement
1. When the quantity of electric charge is not sufficient, the icon of
low battery will appear on the lower part of the screen. Though the
battery still can be used, it would be perfect to replace it.
2. When the quantity of electric charge of the battery is lower than
the minimal value, Lo” symbols will be displayed on the screen,
and battery icon flashes and the sound of “Beep is sent out.
Unless you change a new battery, you can not use the thermometer
to conduct measurement.
3. Operation of changing battery.
4. Take out the old battery: Open the battery cap; put 2 new AAA
batteries on with correct cathode direction into the battery seat.
Please observe the related national laws of disposing the
abandoned battery and don’t litter to the garbage can.
Please take out the battery if the device is not used for
long periods of time.
Please don’t put the battery in the fire.
To protect the environment, dispose of empty battery at your retail
store or at appropriate collection sites according to national or
local regulations.
- 13 -
1) Don’t put the thermometer under the sunshine, high tempera-
ture and moist environment or someplace which maybe get in
touch with fire or is vulnerable to vibration.
2) Take out the battery if don’t use the device in a long time.
WARNING: No modification of this equipment is allowed!
NOTES:
Don not use abrasive cleaners.
Don’t use other non-recommended methods to perform disinfect.
Non-waterproof, don’t use the abrasive cleaner to clean the
product, don’t drop the thermometer in the water or the other liquid.
1) We do not authorize any institution or individual to maintain and
repair of the product. If you suspect that the products have any
questions, please contact the manufacturer or distributor to handle
the case.
2) The user must not attempt any repairs to the device or any of its
accessories. Please contact the retailer for repair.
3) Opening of the equipment by unauthorized agencies is not
allowed and will terminate any claim to warranty.
9. Maintenance
The thermometer is initially calibrated at the time of manufacture.
If this thermometer is used according to the use instruction,
periodic re-adjustment is not required. If any time your question
the accuracy of measurement, please contact distributor or
manufacturer, the contact information see last page.
10. Calibration
11. Storage
Only use original accessories. Check that the contents of the
delivery are complete.
12. Accessories
Quantity
Parts
1pc
PC868 device
2pcs
AAA battery
1pc
User Manual
- 14 -
13. Trouble-shooting
Troubles or error
message




󽫖󽫗


󽫖󽫗










󽃡
󽩛󽩚󽩗




󽩘󽩗󽩗
󽩘󽩗󽩗󽩗






󽩚󽩙󽩗





󽩗


󽩘󽩗󽩛󽩗



󽫕


󽩘󽩗󽩛󽩗
󽩚󽩗

󽃡





󽃢

󽩚󽩗


Checklists or situation
󽩖
󽩖


󽃢
Countermeasures or solution

- 15 -
14. Specifications
*The above specifications are subject to change without prior notice.






󽩜
󽩘󽩗















󽩟󽩝󽩟

󽩚󽩙
󽩗󽩚
󽩗󽩘󽩗󽩘
󽩘󽩗󽩛󽩗󽩘󽩜󽩟󽩜󽩞󽩗󽩘󽩗󽩝
󽩙󽩜󽩜󽩗󽩉󽩠󽩜󽩞󽩗󽩘󽩗󽩝
󽩘󽩛󽩠󽩠󽩜󽩛󽩜
󽩘󽩛󽩜󽄰
󽩊󽩚󽩟
󽩙󽩙



󽩚󽩙󽩗󽩛󽩚󽩗
󽩗󽩘󽩗󽩗



󽩗󽩙󽩚󽩜󽩜󽩛󽩙󽩗
󽩗󽩚󽩚󽩙󽩗󽩚󽩜󽩛󽩛󽩙󽩘󽩛󽩚󽩗
- 16 -
15. Standard list
Shenzhen PACOM Medical Instruments Co., Ltd declares that the
PC868 complies with following applicable standards:
󽩠󽩟󽩗
󽩘󽩗󽩛󽩘
󽩝󽩗󽩝󽩗󽩘󽩘
󽩝󽩗󽩝󽩗󽩘󽩘󽩙
󽩝󽩗󽩝󽩗󽩘󽩘󽩝
󽩝󽩗󽩝󽩗󽩘󽩘󽩘󽩘
󽩘󽩙󽩛󽩞󽩗󽩜
󽩟󽩗󽩝󽩗󽩘󽩙󽩜󽩝
󽩝󽩙󽩚󽩗󽩛
󽩝󽩙󽩚󽩝󽩝
󽩘󽩗󽩠󽩠󽩚󽩘



󽩘

󽩘󽩙



󽩘󽩘󽩘




󽩜



󽩘

󽩙󽩜󽩝



󽩘󽩝


- 17 -




󽩙󽩗󽩗󽩙󽩠󽩝

󽩠󽩚󽩛󽩙󽩙󽩗󽩗󽩞󽩛󽩞󽃡




󽫕
󽩘󽩙󽩜
󽃡
󽩘󽩜󽩗


󽩙󽩙
16. Disposal
17. Normalized symbols
Dispose of the device in accordance with the regulation
applicable at the place of operation. Dispose of at public
collection point in the EU countries 2002/96/EC WEEE
Directive.
If you have any queries, please refer to the local authorities
responsible for waste disposal.
To protect the environment, dispose of empty battery at
your retail store or at appropriate collection sites according
to national or local regulations.
Dispose of at public collection point in the EU countries ‒
2006/66/EC Directive.
NOTES:
Handing of battery and wastes method, please act according to the
native law to proceed to handle.
Take out the battery if you are not going to use the unit for a long
time.
- 18 -
1) The digital thermometer needs special precautions regarding
EMC and needs to be installed and put into service according to the
MEC information provided in the ACCOMPANYING DOCUMENTS.
2) Wireless communications equipment such as wireless home
network devices, mobile phones, cordless telephones and their
base stations, walkie-talkies can effect this equipment and should
be kept at least a distance d=3.3m away from the equipment. (Note:
As indicated in Table 6 of IEC 60601-1-2:2007 of ME EQUIPMENT, a
typical cell phone with a maximum output power of 2W yields
d=3.3m at an IMMUNITY LEVEL of 3V/m).
We grant you a lifetime guarantee after the date of purchase for
one year. Any damage caused by improper handling shall not be
covered by the guarantee. Batter and packaging are also excluded
from the guarantee. All other damage claims excluded. A guarantee
claim must be submitted with the purchase receipt. Please pack
your defective instrument well and send with sufficient postage to
the distributor.
18. EMC DECLATION
19. Guarantee
Shanghai International Holding Corp. GmbH (Europe)
Address:Eiffestrasse 80, 20537 Hamburg Germany
Tel:0049-40-2513175
Fax : 0049-40-255726
User manual Edition: V2.1
Printed on: Sep. 2019
Shenzhen Pacom Medical Instruments Co., Ltd.
Address:On the 8th floor of B District, B Building, No.5, Industry
five road, Jiangbian Community, Songgang,
Shenzhen, China.
Tel:86-755-32920339
Website: www.pacomsz.com
- 19 -
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

PACOM PC868. Infrared Thermometer User manual

Category
Digital body thermometers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI