xv
î‚‹Stopping the Inverter by Notifying Programming Device Errors to the Inverter
(External Fault Function) ..............................................................................................6-87
Output Terminal Functions..........................................................................6-88
Monitor Constants.......................................................................................6-90
î‚‹Using the Analog Monitor Constants ............................................................................6-90
î‚‹Using Pulse Train Monitor Contents .............................................................................6-93
Individual Functions....................................................................................6-95
î‚‹Using MEMOBUS Communications .............................................................................6-95
î‚‹Using the Timer Function............................................................................................6-107
î‚‹Using PID Control ....................................................................................................... 6-108
î‚‹Energy-saving............................................................................................................. 6-117
î‚‹Setting Motor Constants .............................................................................................6-119
î‚‹Setting the V/f Pattern.................................................................................................6-121
î‚‹Torque Control (SPEC: E or Later Only) .................................................................... 6-128
î‚‹Speed Control (ASR) Structure ..................................................................................6-135
î‚‹Increasing the Speed Reference Response (Feed Forward Control)
(SPEC: E or Later Only) .............................................................................................6-141
î‚‹Droop Control Function (SPEC: E or Later Only) .......................................................6-142
î‚‹Zero-servo Function (SPEC: E or Later Only) ............................................................6-144
Digital Operator Functions........................................................................6-147
î‚‹Setting Digital Operator Functions..............................................................................6-147
î‚‹Copying Constants .....................................................................................................6-150
î‚‹Prohibiting Writing Constants from the Digital Operator .............................................6-154
î‚‹Setting a Password.....................................................................................................6-154
î‚‹Displaying User-set Constants Only ...........................................................................6-155
Options .....................................................................................................6-156
î‚‹Performing Speed Control with PG.............................................................................6-156
î‚‹Using Digital Output Boards .......................................................................................6-160
î‚‹Using an Analog Reference Board (SPEC: E or Later Only)......................................6-162
î‚‹Using a Digital Reference Board (SPEC: E or Later Only) .........................................6-163
Using Inverters for Elevating Machines ....................................................6-168
î‚‹Brake ON/OFF Sequence...........................................................................................6-168
î‚‹Stall Prevention during Deceleration...........................................................................6-170
î‚‹Autotuning...................................................................................................................6-170
î‚‹Braking Resistor Overheating Protection....................................................................6-170
î‚‹Momentary Power Loss Restart .................................................................................6-170
î‚‹Torque Limit ................................................................................................................6-170
î‚‹I/O Open-phase Protection and Overtorque Detection...............................................6-171
î‚‹External Baseblock Signal..........................................................................................6-171
î‚‹Acceleration/Deceleration Time.................................................................................. 6-171
Magnetic Contactor on the Inverter’s Output-side ......................................................6-171
î‚‹Control-related Adjustments .......................................................................................6-172
î‚‹Reducing Shock during Elevating Machine Start, Stop, Acceleration,
and Deceleration.........................................................................................................6-174
î‚‹Confirming Startup Current and Reducing Carrier Frequency....................................6-177