Brink Postheater and extra preheater enable you to enhance the capabilities of your Renovent Sky 150 or Renovent Excellent 180 heat recovery systems. These add-ons provide additional heating options, allowing you to customize the temperature of incoming air to suit your comfort needs. The extra preheater can be used together with the Renovent Sky 150, while the postheater is compatible with both Renovent Sky 150 and Renovent Excellent 180. Installation involves connecting the device to the designated connectors on the heat recovery system and adjusting the settings accordingly.

Brink Postheater and extra preheater enable you to enhance the capabilities of your Renovent Sky 150 or Renovent Excellent 180 heat recovery systems. These add-ons provide additional heating options, allowing you to customize the temperature of incoming air to suit your comfort needs. The extra preheater can be used together with the Renovent Sky 150, while the postheater is compatible with both Renovent Sky 150 and Renovent Excellent 180. Installation involves connecting the device to the designated connectors on the heat recovery system and adjusting the settings accordingly.

Installation regulations
Postheater and extra preheater
English
Postheater and extra preheater general
Renovent Excellent and Renovent Sky
The extra preheater or postheater (only possible for Plus version) are electrically connected to connector X14 or
X12. Just for a postheater there is also a temperature sensor that must be connected to no. 7 and 8 of the 9-pole
connector that is only installed in the Plus version.When using an extra preheater together with a Renovent Sky
150, step number 11 is applied (and for postheater also step number 12); when using an extra preheater together
with a Renovent Excellent 180, step number 12 is applied and for a postheater step number 13 & 14.
All sets are delivered including 2 adapters Ø125-Ø160 and a connection piece Ø125.
Postheater set no 310730 (Sky 150 & Excellent 180)
1 = Heang coil C1 = brown
2 = Maximum safety with manual reset C2 = blue
3 = LED maximum safety; lights up when acvated C3 = green/yellow
4 = To PCB connector X14 C4 = black
5 = Temperature sensor C10 = yellow
6 = To the 9-pole screw connector nr. 7 & nr. 8
Postheater and extra preheater 614872-A
Extra preheater set no 310683 (Sky 150)
1 = Heang coil C1 = brown
2 = Maximum safety with manual reset C2 = blue
3 = LED maximum safety; lights up when acvated C3 = green/yellow
4 = To PCB connector X14 C4 = black
Preheater set no 310740 (Renovent Excellent 180)
1 = Heang coil C1 = brown
2 = Maximum safety with manual reset C2 = blue
3 = LED maximum safety; lights up when acvated C3 = green/yellow
4 = Connecon (factory mounted) C4 = black
Brink / 3Postheater and extra preheater 614872-A
Extra preheater and postheater with Sky 150
Connecon extra preheater set 310683 to Sky 150
Seng step number no. 11
*A = The strain reliever to be installed by the installer (not supplied with the appliance) for feeding the 230 volt cable to the extra
preheater.
Postheater and extra preheater 614872-A
Connecon post heater set 310730 to Renovent Sky 150
Seng step number no. 11 & no. 12 Connecng temperature sensor to
connector no. 7 and no. 8.
*A = The strain reliever to be installed by the installer (not supplied with the appliance) for feeding the 230 volt cable to the
postheater.
Step numbers seng Sky 150
Step
No. Description Factory setting Adjusting range
11 Heater 0
0 = no additional heater
1 = additional preheater
2 = postheater
12 Temperature postheater 21 °C 15,0 °C - 30,0 °C
Brink / 5Postheater and extra preheater 614872-A
Postheater and preheater with Renovent Exc. 180
Connecon preheater set 310740 to Renovent Excellent 180
Seng stepnumber no. 12
The strain reliever to be installed by the installer for feeding the 230 volt cable to the postheater or preheater.
1 = Heating coil C1 = brown
2 = Maximum safety with manual reset C2 = blue
3 = LED maximum safety; lights up when activated C3 = green/yellow
4 = To PCB connector X12 C4 = black
Postheater and extra preheater 614872-A
Connecon postheater set 310730 to Renovent Excellent 180
Seng stepnumber no. 13 & no. 14 Connecng temperature sensor to
connector no. 7 and no. 8.
The strain reliever to be installed by the installer (not supplied with the appliance) for feeding the 230 volt cable to the postheater.
1 = Heating coil C1 = brown
2 = Maximum safety with manual reset C2 = blue
3 = LED maximum safety; lights up when activated C3 = green/yellow
4 = To PCB connector X14 C4 = black
5 = Temperature sensor C5 = yellow
6 = To the 9-pole screw connector nr. 7 & nr. 8
Brink / 7Postheater and extra preheater 614872-A
Step numbers seng Renovent Excellent 180
Step
No. Description Factory setting Adjusting range
12 Preheater connected OFF Off = switched off
ON = switched on
13 Heater 0
0 = no additional heater
1 = preheater
2 = postheater
14 Tempatature postheater 21 °C 15,0 °C - 30,0 °C
Postheater and extra preheater 614872-A
Technical information and service
Technical information post- and preheater
Supply voltage 230 V/ 50 Hz
Weight 2,5 kg
Duct diameter Ø160 mm
Rated power 1000 W
Rated current 4,5 A
Service
When ordering parts, in addition to the article code number, please state the type of the heater, the heat recovery
appliance, the serial number, the year of production and the name of the part.
Description Article code
Maximum safety : 531528
Heating coil : 531463
Mains cable with plug 230V (set 310730 & 310683( :540919
Mains cable with edge connector 230V (set 310740) : 073973
Brink / 9Postheater and extra preheater 614872-A
Brink Climate Systems BV
P.O. Box 11 NL-7950AA Staphorst
T +31 (0) 522 46 99 44
E info@brinkclimatesystems.com
www.brinkclimatesystems.com
www.brinkairforlife.com
614872-A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Brink Postheater and extra preheater Installation guide

Type
Installation guide

Brink Postheater and extra preheater enable you to enhance the capabilities of your Renovent Sky 150 or Renovent Excellent 180 heat recovery systems. These add-ons provide additional heating options, allowing you to customize the temperature of incoming air to suit your comfort needs. The extra preheater can be used together with the Renovent Sky 150, while the postheater is compatible with both Renovent Sky 150 and Renovent Excellent 180. Installation involves connecting the device to the designated connectors on the heat recovery system and adjusting the settings accordingly.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI