VULCAN & WOLF C24GA Solenoid Valve Operating instructions

Type
Operating instructions
SOLENOID VALVE
C24GA MODELS
- NOTICE -
This Manual is prepared for the use of trained Hobart Service
Technicians and should not be used by those not properly
qualified.
This manual is not intended to be all encompassing. If you have
not attended a Hobart Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Hobart Service Technician.
The reproduction, transfer, sale or other use of this Manual,
without the express written consent of Hobart, is prohibited.
SERVICE KIT INSTRUCTION
A product of Hobart Service 701 S. Ridge Ave Troy, OH 45374
F45832
INSTALLATION INSTRUCTIONS
SOLENOID VALVE ON SOLARONICS BURNER ASSEMBLY
SOLENOID VALVE 00-858579-00009
WARNING
Disconnect the electrical power to the machine and follow lockout / tagout procedures.
NOTE: The vendor has discontinued the coil style shown in Fig. 1. The replacement valve will now have a coil like
Fig. 2.
Use top two vertical connections (1, Fig. 2) on current valve. The bottom horizontal connection (2, Fig. 2) is for ground
is not used on the C24GA Solaronics burner.
PREVIOUS VALVE CURRENT VALVE
Fig. 1
Fig. 2
© HOBART SERVICE 2020 Page 1 of 1 F45832 (January 2020)
  • Page 1 1
  • Page 2 2

VULCAN & WOLF C24GA Solenoid Valve Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI