GB
20
General
This manual contains instructions about
how the Contura i10 and i20 must be
constructed and installed. In order for
the Insert’s function and safety to be
guaranteed, we recommend that the
installation is carried out by a professional.
Our Contura dealers can recommend
suitable technicians, information about our
dealers can be found at www.contura.eu
Instructions for lighting are also supplied
with the insert. Read them carefully and
keep them safe for future use.
Eldstadsbeklädnad
Diffusor
Rökhylla
Spjäll
Typskylt
Asklåda
Roster
Motvikt
Servicelucka
Justerbara fötter
Anslutningsstos
Bottenisolering
Rosterhandtag
Hearth cladding
Smoke baffle
Damper
Type plate
Ash-pan
Bottom insulation
Connector
Adjustable feet
Service hatch
Counter weight
Grate
Grate handle
Diffuser
GENERAL
Structural support
Check that wooden joists have the
sufficient load capacity for the insert,
chimney and construction parts that
are used when recessing. A completed
installation can usually be positioned on
a normal wooden joist in a single-family
house as long as the total weight does not
exceed 400 kg.
Hearth plate
If the floor under the stove is flammable,
it must be protected by a non-flammable
material e.g. natural stone, concrete or 0.7
mm thick metal. The floor in front of the
hearth opening must be protected against
any falling embers using non-flammable
material that covers an area at least 300
mm in front and 100 mm along each side
of the hatch opening. A painted metal or
toughened glass hearth plate is available as
an accessory.
Technical Data
Model i10 i20
Power output 6-12 kW 6-12 kW
Nominal output 9 kW 10 kW
Ef ficiency 81% 81%
Weight (kg) 215 240
Width (mm) 785 685
Depth (mm) 515 515
Height (mm) 1315 1535
Connector diameter Ø200 mm ext.
Type approved in accordance with:
European standard EN-13229
DIN plus
Bauart 1
15A B-VG
Test report no. i10: RRF-29 09 2077,
i20: RRF-29 09 2078
The inserts are type approved and can
be connected to a chimney dimensioned
for a flue gas temperature of 350°C, the
external diameter of the connector is Ø200
mm. Supply air from the open air should
be used as combustion air. Follow the
recommendations for cross section areas
for convection air.
Chimney
The insert requires a draft in the chimney
of at least –12 Pa. The draft is affected
both by the length and area of the chimney,
and by how well sealed it is.
• Once the lighting phase is complete,
this insert must be operated with the
door closed because of the risk of smoke
entering the room. Always open the door
carefully and slowly to prevent blow back
because of the changing pressure in the
stove.
• Carefully check that the chimney is sealed
and that there is no leakage around soot
hatches and flue connections.
Note that a flue with sharp bends and
horizontal routing reduces the draught in
the chimney. Maximum horizontal flue is 1
m, on the condition that the vertical flue
length is at least 5 m. It must be possible
to sweep the full length of the flue and the
soot hatches must be easily accessible.