Cleveland Range OGB10.10 Datasheet

Type
Datasheet
SECT. IIA PAGE 17
0810
Featuring the
"Advanced Closed
System
+
3"
Short Form Specifications
Cooking Modes:
I
I
Hot Air
I
I
Retherm
I
I
"Delta T" slow cooking
I
I
Steam
I
I
"Cook & Hold"
I
I
"Crisp & Tasty"
I
I
Combi
Cleveland Standard Features:
I
I
"Advanced closed system" with "Crisp & Tasty" de-moisturizing feature
I
I
High efficiency, power burner heating system for hot air and steam
generator saves energy and provides fast heat up times
I
I
Fully insulated steam generator and cooking compartment for
maximum energy savings
I
I
Polished cooking compartment with coved corners for easy cleaning
I
I
Five (5) 12" x 20" wire shelves
I
I
Hinged fan guard and hinged removable pan racks
I
I
Two (2) speed auto reversing convection fan for even heat distribution
I
I
Space saving, easy to operate "Disappearing Door"
I
I
"Antibacterial Hygenic Door Handle" with embedded silver ion
protection
I
I
Door latch with safety vent position and wear-free door switch
I
I
Vented, double glass door with integrated door stop and self
draining condensate drip tray
I
I
Easy to change, press-fit door seal
I
I
Oven light with shock resistant safety glass
I
I
Multipoint core temperature probe
I
I
Digital controls for temperature, time and core probe settings
I
I
Self diagnostic system with full text message display
I
I
Easy to understand menu icons with bright graphics display
I
I
User friendly selector dial
I
I
Exclusive "Smart Key" for selecting option settings
I
I
Eight (8) "Press & Go" one step, recipe start buttons
I
I
Cook book library for up to 250 stored recipe programs, each
recipe capable of 20 steps
I
I
Memory module for saving unit settings and recipes
I
I
Smooth action hand shower for compartment cleaning
Gas Fired Steam Generator
I
I
Quiet, high efficiency, power burner heating system
I
I
Built-in automatic rinse system
I
I
Automatic fill and water level control
I
I
Automatic generator drain
Shall be Cleveland Model: OGB 10.10 Combination Convection Oven /
Steamer with simple to operate programmable controls for Hot Air,
Convection Steam, and Combination cooking modes, "Cook & Hold" and
"Delta T" slow-cooking capabilities, "Advanced Closed System" with "Crisp
& Tasty" de-moisturizing feature. Multiple cooking stage programs, stored
recipe library, multipoint core temperature probe, "Press & Go", one-step
recipe start buttons, "Smart Key" for selecting option settings, Two (2) speed
auto reversing convection fan. Quiet, high efficiency power burner heating
system; steam generator with automatic drain. "Disappearing Door" with
"Antibacterial Hygenic Door Handle"
.
Capacity for ten (10) 12" x 20" x 2 1/2"
pans.
M
ODEL: OGB 10.10
CAPACITY: Eleven (11) - 13” by 18” by 1” half size sheet pans or
Ten (10) - 12” x by 20” by 2 1/2” steam table pans
Options and Accessories
Ë CONVOClean hands free automatic compartment washing system
Ë CONVOControl software for establishing "HACCP controls" and
automatic documentation of the cooking process
Ë Equipment stand(s)
Ë Equipment stand(s) with Casters
Ë Stacking kit for mounting one (1) OGB 6.10 model on top of
one (1) OGB 10.10
Ë Lockable cover over operating controls for prison installations
Ë Ethernet connection for networking and controlling up to 100 units
with a personal computer
Ë Propane gas option
Ë Plate rack for banquet operations
Ë Plate rack cart
Ë Thermal cover for plate or pan rack
Ë CONVOClean compartment cleaning solution
Ë CONVORinse compartment rinse cycle solution
Ë "Dissolve" generator descaling solution
Ë CONVOGrill Grilling Rack
Ë Chicken Grill Rack
Ë 12" x 20" Wire Baskets for frying products
Ë Additional 12" x 20" Wire Shelves
Ë Kleensteam II Water Filters
Ë easyToUCH™ control panel
GAS Fired with Steam Generator
Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COMBI OVEN-STEAMER
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.
SECT. IIA PAGE 18
0810
Model: OGB 10.10
Pan Capacity [
Unit has 11 slide rails at 2.64" (67mm) apart
]:
1
0 (12" x 20" x 2 1/2") steam table pans 11 (12" x 20" x 1") steam table pans
1
1 (13" x 20") half size wire racks 11 (13" x 18") half size sheet pans
10 (12" x 20") frying baskets - (no wire racks needed)
For Banquet Operations: Optional Plate Rack holds 32 plates
Unit Dimensions: Width - 41.04", Depth - 34.50", Height - 45.68"
Shipping Dimensions: Width - 47", Depth - 41", Height - 54"
(including packaging)
Shipping Weight: 475 Lbs
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
n
ext to the unit.
Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
Installation must comply with all local fire and health codes.
Agency Approvals: UL - Gas, UL - Sanitation (NSF Standards)
Electrical Requirements: 120 volt, 4.9 amps, 60 Hz, single phase
Do not connect to a G.F.I. outlet
Gas Connection: 3/4" NPT
Gas Type: Natural Gas (Propane optional)
Gas Flow Pressure: Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
Total Connected Load: 75,700 BTU (75,700 BTU Propane)
Steam Generator: 68,200 BTU (68,200 BTU Propane)
Hot Air: 75,700 BTU (75,700 BTU Propane)
Water Connections: Cold Water (drinking water quality)
Dynamic Pressure: 35 - 60 PSI
Water Inlets: 3/4" GHT-F (Female Garden Hose Connection)
Treated Water for Steam Generator
Untreated Water for Condenser and Hand Shower
NOTE:
The owner / operator / purchaser must ensure that the Water Quality
Requirements are met. Not meeting the water quality requirements will void
the original equipment warranty.
Water Quality Requirements:
TDS . . . . . . . . . . . < 60 ppm pH Factor 7.0 – 8.5
Total Alkalinity . . . < 20 ppm Free Chlorine < 0.1 ppm
Silica . . . . . . . . . . < 13 ppm Conductivity min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
Drain Connection: 2" Tube
Venting: Exhaust Hood required
Gas Exhaust for Hot Air Heating
Gas Exhaust for Steam Generator
Air Vent
*Connection for Cleaning Solution
*Connection for Rinse Cycle
Low Pressure Safety Valve
*Available as an option
A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
OEB 10.10
A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
OES 10.10
OGB 10.10
A Water hook up soft water G"
B Water hook up cold water G"
C Drainage hook up DN50
D Power hook up
E Potential equaliser
F Final rinse hook up
G Cleaner hook up
H Air vent piper
I Low pressure safety
J Gas hook up R"
K Exhaust pipe gas (Hot air heating)
L Exhaust pipe gas (Steam generator)
OGS 10.10
A = Water hook up soft water G"
B = Water hook up cold water G"
C = Drainage hook up DN50
D = Power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
J = Gas hook up R"
K = Exhaust pipe gas
36.70"
2.52"
1.58"
38.98"
6.00"
1.82"
44.98"
31.70"
2.80"
11.11"
2.80"
6.97"
3.39"
2.60"
6.46"
10.79"
3.23"
9.45"
9.30"
30.20"
3.27"
6.07"
12.45"
2.96"
17.60"
1.19"
19.30"
6.34"
3.00"
4.97"
S
AV
E1
E2
RC
CS
W1
W2
D
G
FRONT VIEW
TOP VIEW
BOTTOM VIEW
23.63"
2.01"
36.70"
2.52"
1.58"
38.98"
6.00"
1.82"
44.98"
31.70"
2.80"
6.96"
11.11"
2.80"
3.39"
6.46"
10.79"
3.23"
9.45"
9.30"
30.20"
3.27"
6.07"
12.45"
2.96"
17.60"
1.19"
19.30"
6.34"
3.00"
4.97"
S
AV
E1
RC
CS
W1
W2
D
G
FRONT VIEW
TOP VIEW
BOTTOM VIEW
23.63"
2.01"
36.70"
2.52"
1.58"
38.98"
6.00"
1.82"
44.98"
31.70"
2.80"
11.11"
2.80"
3.39"
10.79"
3.23"
9.45"
9.30"
30.20"
3.27"
6.07"
12.45"
2.96"
17.60"
1.19"
19.30"
6.34"
3.00"
4.97"
S
AV
RC
CS
W
1
W2
D
FRONT VIEW
TOP VIEW
BOTTOM VIEW
23.63"
W
1
W
2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
W1
W2
D
RC
S
CS
AV
G
E1
E2
W
W3
  • Page 1 1
  • Page 2 2

Cleveland Range OGB10.10 Datasheet

Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI