HDO-36

Southbend HDO-36 Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Southbend HDO-36 Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Job Item#
www.yatesgd.com www.yatesgraphicdesign.com
Countertop range
Gas Modular Countertop Ranges
Standard Features
- Availablein12”,24”,36”and48”(24”,36”and48”
step-upunitsalsoavailable)
- 33,000BTUNAT(24,000BTULP)opentopnon-
cloggingburner
- Hi/Lowburnercontrols
- Stainlesssteelfrontandsides
- 3/4”reargasconnectionandpressureregulator
- Fullwidthcrumbtray
- 12”castushtopgrates
- 4”stainlesssteellegs
- OneyearPartsandLaborWarranty
(Model HDO-24)
PrintedinUSA
HDO-12, HDO-24, HDO-36, HDO-48
Step-up Models: HDO-24SU, HDO-36SU, HDO-48SU
FormHDORev5(June/2010)
STANDARD CONSTRUCTION SPECIFICATIONS
Exterior Finish:Stainlesssteelfrontandsides.Rearand
bottompanelsareconstructedofaluminizedsteel.
Range Top: Each burner is a 33,000 BTU NAT (24,000
BTULP)castironnon-cloggingburner (available in step-up).
Removableushtopgrates.Center-to-center measurements
betweenburnersnotlessthan12”,side-to-sideorfront-to-back.
Removable one piece, full width crumb tray provided under
burners.
Gas Heat Control System:Eachburneriscontrolledbya
gasvalveforindependentcontrolofame.Onestandingpilot
serviceseachburner.A3/4”reargasconnectionisstandard.
Legs:Stainlesssteel4”adjustablelegs.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
6.3" (160)
2.78" (71)
11" (282)
15" (381)
4" (102)
3" (76)
24.625"
(623)
1" (25)
31.125"
(791)
HDO-12 HDO-24 HDO-36 HDO-48 HDO-24SU HDO-36SU HDO-48SU
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
FormHDORev5(June/2010)
UTILITY INFORMATION
GAS: Each unit has a 3/4” rear
gas connection with a male NPT
connector.Minimumsupplypressure
is 4” W.C.for natural gas and 10”
W.C.forpropane.Allunitsrequire
a regulated gas supply. Pressure
regulatorincluded.Ifusingaexible
hosegasconnection,theI.D.ofthe
hosemustnotbesmallerthan the
connectoron the unit and must comply withANSIZ21.69, providing
an adequate means of restraint to prevent undue strain on the gas
connection.
MISCELLANEOUS
- Ifcastersareusedwithexhose,arestrainingdeviceshould
beusedtoeliminateunduestainontheexhose.
- Minimumclearancefromnoncombustibleconstructioniszero.
Minimumclearancefromcombustibleconstructionis10”onsides
and6”onrear.
- Installunderventedhood.
- Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbendhasapolicyofcontinuousproductresearchand
improvement.Wereservetherighttochangespecicationsand
productdesignwithoutnotice.Suchrevisionsdonotentitlethe
buyertocorrespondingchanges,improvements,additionsor
replacementsforpreviouslypurchasedequipment.
OPTIONS AND ACCESSORIES
StainlessSteelStand
HighPerformanceWOKRing
2”highinsulatorbaseformountingonrefrigeratedbase
Batterysparkignition
Shipping Crate DimenSionS & Weight
moDel WiDth
BurnerS
@Btu (nat/lp)
CrateD
WiDth
CrateD
Depth
CrateD
Weight
HDO-12
12.125”
(308)
2(33K/24K)
31”
(788)
39”
(991)
165lbs
(75kg)
HDO-24/24SU
24.5”
(622)
4(33K/24K)
31”
(788)
39”
(991)
209lbs
(94kg)
HDO-36/36SU
36.75”
(933)
6(33K/24K)
55”
(1398)
39”
(991)
253lbs
(115kg)
HDO-48/48SU
49”
(1245)
8(33K/24K)
55”
(1398)
39”
(991)
299lbs
(135kg)
moDel
gaS (Btu/hr)
natural propane
HDO-12 66,000 48,000
HDO-24/24SU 132,000 96,000
HDO-36/36SU 198,000 144,000
HDO-48/48SU 264,000 192,000
/