Prestige 24i LQ MG User manual

Type
User manual

Prestige 24i LQ MG is a diagnostic kit for the determination of magnesium concentration in serum, plasma, and 24-hour urine samples. It utilizes a colorimetric method to measure magnesium levels, which is important for various physiological processes such as nucleic acid synthesis, energy production, and neuromuscular function. The kit includes reagents for 60 tests and is intended for use with automatic analyzers Prestige 24i, Biolis 24i, Sapphire 400, and their Premium counterparts.

Prestige 24i LQ MG is a diagnostic kit for the determination of magnesium concentration in serum, plasma, and 24-hour urine samples. It utilizes a colorimetric method to measure magnesium levels, which is important for various physiological processes such as nucleic acid synthesis, energy production, and neuromuscular function. The kit includes reagents for 60 tests and is intended for use with automatic analyzers Prestige 24i, Biolis 24i, Sapphire 400, and their Premium counterparts.

PRESTIGE 24i LQ MG page 1
Cat. No 4-229
PRESTIGE 24i LQ MG
DIAGNOSTIC KIT
FOR DETERMINATION OF
MAGNESIUM CONCENTRATION
INTRODUCTION
Magnesium in human organism occurs mainly in bone (about 50%) but is
present also intracellularly in other tissues. Magnesium serves as a cofactor
for multiple enzymatic reactions involved in nucleic acids synthesis, transport
and production of energy. Magnesium is important in neuromuscular
conduction and activation. Reduced magnesium level generates: concentration
disturbances, fatigue, muscle tremor, anxiety state.
METHOD PRINCIPLE
Magnesium forms a purple coloured complex in alkaline solution. In the
presence of EGTA, the reaction is specific. The intensity of the purple colour
is proportional to the magnesium concentration.
REAGENTS
Package
Cat. No 4-229
(24-TRAY)
4 x 60 ml
1-Reagent
The reagent is stable up to the kit expiry date printed on the package when
stored at 2-8 C. Stability on board of the analyser at 2-10 C: Prestige 24i
3 weeks, Biolis 24i Premium 3 weeks. The reagent is air sensitive, to extend
reagents stability it is recommended to keep reagent’s bottles recapped on the
board of analyser. Protect from light and avoid contamination!
Concentrations in the test
xylidyl blue
0.15 mmol/l
EGTA
0.1 mmol/l
buffer (pH 11.5)
detergent
Warnings and notes
Product for in vitro diagnostic use only.
The reagents contain sodium azide (< 0.1%) as a preservative. Avoid
contact with skin and mucous membranes.
It is recommended to use disposable plastic materials. If it is not
possible, the glassware should be washed with 1% HCl solution and
rinsed with plenty of distilled water.
SPECIMEN
Serum, heparinized plasma free from hemolysis, 24-hours urine.
Recommended anticoagulants: heparine lithium, sodium or ammonium salt.
Serum should be separated from red blood cells as soon as possible after
blood collection, because erythrocytes contain approximately 3 times the
magnesium concentration found in normal serum.
Urine preparation: acidify urine with some drops of concentrated
hydrochloride acid to pH 1.0. Then dilute 1 part of acidified urine with 4 parts
of distilled water. Multiply the result by 5. Mix well samples before analysis.
Serum and plasma can be stored up to 7 days at 2-8ºC. For longer storage
samples should be frozen at -20ºC.
24-hours urine samples can be stored up to 7 days at 2-8ºC.
Nevertheless it is recommended to perform the assay with freshly collected
samples!
PROCEDURE
This reagent may be used in automatic analysers Prestige 24i, Biolis 24i,
Sapphire 400 and Prestige 24i Premium, Biolis 24i Premium, Sapphire 400
Premium.
1-Reagent is ready to use.
Avoid foaming.
1-Reagent put on basic position in reagent tray.
For reagent blank deionized water is recommended.
REFERENCE VALUES
6
serum / plasma
mmol/l
newborn 2 4 d
0.62 0.91
children 5 mo 6 y
0.70 0.95
6 12 y
0.70 0.86
12 20 y
0.70 0.91
adults
0.66 1.07
24-hours urine:
mmol/24h
3 5
It is recommended for each laboratory to establish its own reference ranges
for local population.
QUALITY CONTROL
For internal quality control it is recommended to use the CORMAY SERUM
HN (Cat. No 5-172) and CORMAY SERUM HP (Cat. No 5-173) for
determination in serum or CORMAY URINE CONTROL LEVEL 1
(Cat. No 5-161) and LEVEL 2 (Cat. No 5-162) for determination in urine with
each batch of samples.
For the calibration of automatic analysers systems the CORMAY
MULTICALIBRATOR LEVEL 1 (Cat. No 5-174; 5-176) and LEVEL 2
(Cat. No 5-175; 5-177) is recommended.
The calibration curve should be prepared every week (Prestige 24i, Biolis 24i
Premium), with change of reagent lot number or as required e.g. quality
control findings outside the specified range.
PERFORMANCE CHARACTERISTICS
These metrological characteristics have been obtained using the automatic
analysers Prestige 24i and Biolis 24i Premium. Results may vary if a different
instrument or a manual procedure is used.
Sensitivity (Prestige 24i): 0.14 mg/dl (0.057 mmol/l).
Sensitivity (Biolis 24i Premium): 0.06 mg/dl (0.025 mmol/l).
Linearity (Prestige 24i): up to 7.3 mg/dl (2.99 mmol/l).
Linearity (Biolis 24i Premium): up to 7.6 mg/dl (3.12 mmol/l).
Specificity / Interferences
Haemoglobin up to 0.313 g/dl, ascorbate up to 62 mg/l, bilirubin up to
15 mg/dl, triglycerides up to 1000 mg/dl and calcium up to
20 mg/dl do not interfere with the test.
Precision (Prestige 24i)
Repeatability (run to run)
n = 10
Mean
[mg/dl]
SD
[mg/dl]
CV
[%]
level 1
level 2
2.03
4.24
0.02
0.03
0.75
0.64
Reproducibility (day to day)
n = 10
Mean
[mg/dl]
SD
[mg/dl]
CV
[%]
level 1
level 2
1.94
3.93
0.05
0.10
2.32
2.42
Precision (Biolis 24i Premium)
Repeatability (run to run)
n = 10
Mean
[mg/dl]
SD
[mg/dl]
CV
[%]
level 1
level 2
2.05
4.21
0.02
0.04
1.07
0.93
Reproducibility (day to day)
n = 10
Mean
[mg/dl]
SD
[mg/dl]
CV
[%]
level 1
level 2
1.97
4.16
0.04
0.07
2.12
1.76
Method comparison
A comparison between magnesium values determined at Prestige 24i (y) and
at ADVIA 1650 (x) using 93 samples gave following results:
y = 1.0422 x - 0.1068 mg/dl;
R = 0.970 (R correlation coefficient)
PRESTIGE 24i LQ MG page 2
A comparison between magnesium values determined at Biolis 24i Premium
(y) and at ADVIA 1650 (x) using 119 samples gave following results:
y = 0.9195 x + 0.036 mg/dl;
R = 0.980 (R correlation coefficient)
WASTE MANAGEMENT
Please refer to local legal requirements.
LITERATURE
1. C.K., Mann, J.H., Yoe, Anal. Chem. 28 (2), 202-205 (1956).
2. C. Bohuon, Clin. Chim. Acta 7, 811-817 (1962).
3. C.A, Burtis, E.R. Ashwood, eds. Tietz Fundamentals of Chemical
Clinical Chemistry 4th ed. W.B. Saunders, 690-691, (1996).
4. A. J. Pesce, L.A. Kaplan, ed., Methods in Clinical Chemistry, Mosby,
1021-1026 (1987).
5. W.R. Faulkner, S. Meites, ed. Selected Methods for the Small Clinical
Laboratory, AACC Press, 277-281 (1982).
6. C.A. Burtis, E.R. Ashwood, ed. Tietz Textbook of Clinical Chemistry,
3rd ed. Philadelphia, PA: Moss D. W., Henderson A. R. 1825 (1999).
APPLICATION for Prestige 24i, Biolis 24i and Sapphire 400
Item name
22
MG
Data information
Calibration
Units
mg/dl
Type
Linear
Decimals
2
Standard
#1
*
#4
Analysis
#2
*
#5
Type
END
#3
#6
Main W.Length1
505 nm
Sub W.Length2
700 nm
Normal Range
Method
Xylidyl blue
Male
Female
Low
High
Low
High
Corr
Serum
1.6
2.6
1.6
2.6
Slope
Inter
Urine
Y=
1.000
X+
0.000
Plasma
1.6
2.6
1.6
2.6
CSF
Dialysis
Other
Item name
22
MG
Aspiration
Data Process
Kind
Single
Read
Absorbance Limit
Start
End
Low
-0.100
Volume
Main
53
54
High
2.000
Sample
3
µl
Sub
7
11
Reagent1
250
Reagent2
Factor
Endpoint Limit
2.000
Blank correction
1.000
Linear Check (%)
Third Mix.
OFF
Dilution
R1 Blank
Water-Blank
Diluent
100:Dil2
Monitor
Prozone Check
0 Level Point
1
Start
End
Limit (%)
Span
3.000
First
Second
Low
Third
Low
Item name
22
MG
Auto Rerun SW
Auto Rerun Condition (Absorbance)
ON
Absorbance Range
Lower
OFF
Auto Rerun Range (Result)
Higher
OFF
ON
ON
Lower
Higher
Prozone Range
OFF
Serum
0.14
7.3
Urine
Plasma
CSF
Dialysis
Other
APPLICATION for Prestige 24i Premium, Biolis 24i Premium and
Sapphire 400 Premium
Item No.
22
Item Name
MG
Optical
Data information
Calibration
Units
mg/dl
Type
Linear2
Decimals
2
Std sample conc.
Blank
0
#1
*
#2
*
Analysis
#3
#4
#5
Type
END method
#6
Main Wave Length
505 nm
Sub Wave Length
700 nm
Method
Xylidyl blue
Correlation
Slope
Intercept
Y=
1
X+
0
Item No.
22
Item Name
MG
Optical
Aspiration
Data Process
Kind
Single
Read
Start
End
Vol.
Main
31
32
Kind
Vol.
Add
Units
Sub
9
10
Sample
3
5
µl
Reagent 1
250
10
µl
Abs.Limit Low
High
-0.1
~
2
Blank value
Correction value
Water Blank
Blank correction
End Point Limit
2
Reaction Monitor
Linear Check (%)
0 Level Point
1
Span
3
Prozone Check
Start
End
Limit (%)
Third mixing
First
OFF
Second
Low
Item No.
22
Item Name
MG
Optical
Normal Range
Panic Range
Male
Female
Male
Female
Low
High
Low
High
Low
High
Low
High
Serum
1.6
2.6
1.6
2.6
Serum
Urine
Urine
Plasma
1.6
2.6
1.6
2.6
Plasma
CSF
CSF
Dialysis
Dialysis
Other
Other
Item No.
22
Item Name
MG
Optical
Auto Rerun SW
Auto Rerun Condition
(Absorbance)
ON
Lower
OFF
Auto Rerun Range (Conc.)
Higher
OFF
First
Dil
Low
High
Re
Value
Dil
Re
Value
Dil
Auto Rerun Condition
(Prozone)
Serum
0.06
7.6
Urine
OFF
Plasma
CSF
Dilution
Dialysis
100:Dil2
Other
Date of issue: 07. 2013.
MANUFACTURER
PZ CORMAY S.A.
22 Wiosenna Street,
05-092 Łomianki, POLAND
tel.: +48 (0) 22 751 79 10
fax: +48 (0) 22 751 79 14
http://www.cormay.pl
07/13/07/13
  • Page 1 1
  • Page 2 2

Prestige 24i LQ MG User manual

Type
User manual

Prestige 24i LQ MG is a diagnostic kit for the determination of magnesium concentration in serum, plasma, and 24-hour urine samples. It utilizes a colorimetric method to measure magnesium levels, which is important for various physiological processes such as nucleic acid synthesis, energy production, and neuromuscular function. The kit includes reagents for 60 tests and is intended for use with automatic analyzers Prestige 24i, Biolis 24i, Sapphire 400, and their Premium counterparts.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI