Allied Telesis SBx908 GEN2 Installation guide

Type
Installation guide
613-002595 Rev. C
AT-SBx908 GEN2 Switch
Advanced Layer 3+ Modular Switch
AlliedWare Plus™ v5.4.9-0
AT-SBx908 GEN2 Chassis
AT-XEM2-12XT Ethernet Line Card
AT-XEM2-12XTm Ethernet Line Card
AT-XEM2-12XS Ethernet Line Card
AT-XEM2-4QS Ethernet Line Card
AT-XEM2-1CQ Ethernet Line Card
AT-FAN08 Fan Module
AT-SBxPWRSYS2 AC Power Supply
AT-SBxPWRSYS1-80 DC Power Supply
Installation Guide for Virtual Chassis
Stacking
Copyright 2019 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis, VCStack, and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company
names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior
written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for
any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related
to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the
possibility of such damages.
3
Electrical Safety and Emissions Standards
This product meets the following standards.
RFI Emissions: FCC Class A, CISPR 22 Class A, EN55032 Class A, VCCI Class A, ICES-003
Class A, RCM
EMC (Immunity): EN55024, EN61000-3-2, EN61000-3-3
Electrical Safety: UL 60950-1 (
C
UL
US
), EN60825-1 (TUV),
RoHS: RoHS6
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Warning: In a domestic environment this product may cause radio interference in which case
the user may be required to take adequate measures.
Laser Safety EN60825
4
Translated Safety Statements
Important: Safety statements that have the symbol are translated into multiple languages in the
Translated Safety Statements document at www.alliedtelesis.com/support.
Remarque: Les consignes de sécurité portant le symbole sont traduites dans plusieurs langues
dans le document Translated Safety Statements, disponible à l'adresse www.alliedtelesis.com/
library.
5
Preface ...............................................................................................................................................................................15
Document Conventions .......................................................................................................................................................16
Contacting Allied Telesis .....................................................................................................................................................17
Chapter 1: Overview ........................................................................................................................................................ 19
Overview..............................................................................................................................................................................20
AT-SBx908 GEN2 Chassis ..........................................................................................................................................20
XEM2 Ethernet Line Cards...........................................................................................................................................20
Management Software and Interfaces .........................................................................................................................20
Management Methods..................................................................................................................................................21
Management Panel ......................................................................................................................................................21
Power Supplies ............................................................................................................................................................21
AT-SBx908 GEN2 Chassis..................................................................................................................................................22
XEM2 Ethernet Line Cards..................................................................................................................................................23
AT-XEM2-12XT Line Card...................................................................................................................................................25
AT-XEM2-12XTm Line Card................................................................................................................................................27
AT-XEM2-12XS Line Card...................................................................................................................................................29
AT-XEM2-4QS Line Card....................................................................................................................................................31
AT-XEM2-1CQ Line Card....................................................................................................................................................33
Management Panel .............................................................................................................................................................35
USB Port ......................................................................................................................................................................35
NET MGMT Ethernet Management Port......................................................................................................................36
Console (RS-232) Port.................................................................................................................................................37
Switch ID LED..............................................................................................................................................................37
eco-friendly Button .......................................................................................................................................................38
Reset Button.................................................................................................................................................................38
Power Supplies....................................................................................................................................................................39
AT-FAN08 Units ..................................................................................................................................................................41
Specifying Ports in the Command Line Interface.................................................................................................................42
Software and Hardware Releases.................................................................................................
......................................44
Chapter 2: Virtual Chassis Stacking ..............................................................................................................................45
Overview..............................................................................................................................................................................46
Stacking Guidelines.............................................................................................................................................................47
Stack Trunk .........................................................................................................................................................................48
Master and Member Switches.............................................................................................................................................63
Selection of the Master Switch.....................................................................................................................................63
Switch ID Numbers..............................................................................................................................................................64
Optional Feature Licenses...................................................................................................................................................65
Planning the Stack...............................................................................................................................................................66
Stacking Worksheet.............................................................................................................................................................67
Chapter 3: Beginning the Installation ............................................................................................................................69
Hardware Installation Overview...........................................................................................................................................70
Reviewing Safety Precautions.............................................................................................................................................72
Choosing a Site for the Chassis..........................................................................................................................................77
Unpacking the Chassis........................................................................................................................................................78
Unpacking AT-SBxPWRSYS2 AC Power Supplies.............................................................................................................83
Unpacking AT-SBxPWRSYS1-80 DC Power Supplies .......................................................................................................84
Contents
Contents
6
Chapter 4: Installing the Chassis ...................................................................................................................................85
Tools and Material.............................................................................................................................................................. 86
Adjusting the Equipment Rack Brackets............................................................................................................................. 87
Installing the Chassis in an Equipment Rack...................................................................................................................... 91
Installing the Chassis Grounding Wire................................................................................................................................ 92
Installing AT-SBxPWRSYS2 AC Power Supplies............................................................................................................... 95
Installing AT-SBxPWRSYS1-80 DC Power Supplies ......................................................................................................... 99
Installing Ethernet Line Cards........................................................................................................................................... 103
Installing Blank Line Card Slot Covers.............................................................................................................................. 107
Installing the Blank Power Supply Slot Cover................................................................................................................... 109
Installing the Power Cord Retaining Clips......................................................................................................................... 111
Verifying the Installation.................................................................................................................................................... 112
Chapter 5: Wiring the AT-SBxPWRSYS1-80 DC Power Supply .................................................................................113
Introduction....................................................................................................................................................................... 114
Choosing a Method for Attaching the Grounding Wire ..................................................................................................... 116
Connecting the Grounding Wire with the Grounding Terminal ......................................................................................... 117
Connecting the Grounding Wire with Bare Wire............................................................................................................... 122
Introduction to Attaching the Power Wires........................................................................................................................ 125
Connecting the DC Power Wires with the Straight Terminals......................................................................
..................... 126
Connecting the DC Power Wires with the Right Angle Terminals .................................................................................... 133
Connecting Bare DC Power Wires.................................................................................................................................... 139
Chapter 6: Configuring Switches for Stacking ...........................................................................................................143
Introduction....................................................................................................................................................................... 144
Command Summary......................................................................................................................................................... 145
STACKPORT............................................................................................................................................................. 145
STACK ENABLE ....................................................................................................................................................... 145
STACK PRIORITY..................................................................................................................................................... 145
STACK RENUMBER................................................................................................................................................. 146
SWITCH PROVISION................................................................................................................................................ 146
Powering On AT-SBxPWRSYS2 AC Power Supplies...................................................................................................... 148
Starting a Local Management Session............................................................................................................................. 151
Configuring the Master Switch.......................................................................................................................................... 154
General Steps for the Master Switch......................................................................................................................... 154
Configuring the Master Switch................................................................................................................................... 155
Verifying the Master Switch....................................................................................................................................... 158
What to Do Next........................................................................................................................................................ 159
Configuring Member Switches.......................................................................................................................................... 160
General Steps for Member Switches......................................................................................................................... 160
Configuring a Member Switch - Part I........................................................................................................................ 161
Configuring a Member Switch - Part II....................................................................................................................... 163
Verifying a Member Switch........................................................................................................................................ 165
What to Do Next........................................................................................................................................................ 166
Powering on the Stack...................................................................................................................................................... 168
Verifying the Stack............................................................................................................................................................ 169
Chapter 7: Cabling AT-XEM2 Line Card Ports ............................................................................................................171
Cabling the Twisted Pair Ports on AT-XEM2-12XT and AT-XEM2-12XTm Line Cards ................................................... 172
Guidelines to Handling Twisted Pair or Fiber Optic Transceivers..................................................................................... 173
Installing and Cabling Fiber Optic Transceivers ............................................................................................................... 174
Installing Direct Connect Cables....................................................................................................................................... 177
Chapter 8: Replacing Modules .....................................................................................................................................181
Replacing AT-SBxPWRSYS2 AC Power Supplies........................................................................................................... 182
Replacing AT-SBxPWRSYS1-80 DC Power Supplies...................................................................................................... 185
Replacing AT-XEM2 Line Cards....................................................................................................................................... 196
Replacing AT-FAN08 Modules ......................................................................................................................................... 203
Removing AT-FAN08 Modules.................................................................................................................................. 203
Installing AT-FAN08 Modules.................................................................................................................................... 204
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stackiing
7
Chapter 9: Troubleshooting .......................................................................................................................................... 207
Appendix A: Technical Specifications ......................................................................................................................... 213
Physical Specifications......................................................................................................................................................214
Environmental Specifications.............................................................................................................................................216
Power Specifications.........................................................................................................................................................217
Certifications......................................................................................................................................................................219
Port Pinouts.......................................................................................................................................................................220
Contents
8
9
Figure 1: Front Panel of the AT-SBx908 GEN2 Chassis......................................................................................................22
Figure 2: Rear Panel of the AT-SBx908 GEN2 Chassis.......................................................................................................22
Figure 3: XEM2 Ethernet Line Cards....................................................................................................................................23
Figure 4: AT-XEM2-12XT Line Card.....................................................................................................................................25
Figure 5: AT-XEM2-12XTm Line Card..................................................................................................................................27
Figure 6: AT-XEM2-12XS Line Card....................................................................................................................................29
Figure 7: AT-XEM2-4QS Line Card......................................................................................................................................31
Figure 8: AT-XEM2-1CQ Line Card......................................................................................................................................33
Figure 9: Management Panel ...............................................................................................................................................35
Figure 10: Switch ID LED.....................................................................................................................................................37
Figure 11: AT-SBxPWRSYS2 and AT-SBxPWRSYS1-80 Power Supplies .........................................................................39
Figure 12: AT-FAN08 Module...............................................................................................................................................41
Figure 13: PORT Parameter in the Command Line Interface...............................................................................................42
Figure 14: Example Trunks for Stacks of Two, Three, or Four Switches .............................................................................49
Figure 15: Stack of Three Switches with a Linear Trunk......................................................................................................50
Figure 16: Example of a Trunk with Multiple Links Between Switches.................................................................................51
Figure 17: Example of a Stack Trunk of Ports on Multiple Line Cards.................................................................................52
Figure 18: Unsupported Trunk with Too Many Stacking Ports.............................................................................................54
Figure 19: Stack with Three Chassis....................................................................................................................................55
Figure 20: Unsupported Trunk Because Switches Have Different Numbers of Trunk Links................................................56
Figure 21: Unsupported Trunk with Different Ethernet Line Card Models............................................................................57
Figure 22: Unsupported Trunk with Both Direct Connect and Fiber Optic Cables on AT-XEM2-12XT Line Cards..............58
Figure 23: Unsupported Trunk with Both Direct Connect and Fiber Optic Cables on AT-XEM2-4QS Line Cards...............59
Figure 24: Example of a Stack Trunk with AT-XEM2-1CQ Line Cards ................................................................................60
Figure 25: Unsupported Trunk Because a Chassis is Connected to Three Other Chassis..................................................61
Figure 26: Unsupported Trunk Because of Intermediary Network Devices..........................................................................62
Figure 27: NEMA 5-20P Plug and Receptacle .....................................................................................................................77
Figure 28: AT-SBx908 Gen2 Switch Shipping Box..................................................................................
.............................78
Figure 29: Lifting the Switch from the Shipping Box.............................................................................................................79
Figure 30: Removing the Switch from the Protective Shipping Bag.....................................................................................79
Figure 31: Pre-installed Items on the Front and Side Panels...............................................................................................80
Figure 32: Pre-installed Items on the Rear Panel.................................................................................................................81
Figure 33: Accessory Kit.......................................................................................................................................................82
Figure 34: Items in the Shipping Box for the AT-SBxPWRSYS2 AC Power Supply ............................................................83
Figure 35: Items in the Shipping Box for the AT-SBxPWRSYS1-80 DC Power Supply.......................................................84
Figure 36: Chassis Orientations in the Equipment Rack......................................................................................................87
Figure 37: Chassis Orientations in the Equipment Rack (Continued) ..................................................................................88
Figure 38: Chassis Orientations in the Equipment Rack (Continued) ..................................................................................89
Figure 39: Example of Adjusting the Equipment Rack Brackets ..........................................................................................90
Figure 40: Securing the Chassis to the Equipment Rack.....................................................................................................91
Figure 41: Stripping the Grounding Wire..............................................................................................................................92
Figure 42: Removing the Grounding Lug from the Chassis..................................................................................................93
Figure 43: Attaching the Grounding Wire to the Grounding Lug...........................................................................................93
Figure 44: Installing the Grounding Lug and Wire................................................................................................................94
Figure 45: Removing the Blank Power Supply Panel from Power Supply Slot B.................................................................96
Figure 46: Lifting the Locking Handle on the AT-SBxPWRSYS2 Power Supply..................................................................96
Figure 47: Sliding the AT-SBxPWRSYS2 AC Power Supply into the Chassis.....................................................................97
Figure 48: Lowering the Locking Handle on the AT-SBxPWRSYS2 AC Power Supply.......................................................97
Figure 49: On/Off Switch on the AT-SBxPWRSYS1-80 DC Power Supply........................................................................100
Figures
Figures
10
Figure 50: Loosening the Handle locking Screw on the AT-SBxPWRSYS1-80 DC Power Supply....................................100
Figure 51: Lifting the Locking Handle on the AT-SBxPWRSYS1-80 DC Power Supply.....................................................101
Figure 52: Inserting the AT-SBxPWRSYS1-80 DC Power Supply .....................................................................................101
Figure 53: Lowering the Locking Handle on the AT-SBxPWRSYS1-80 DC Power Supply................................................102
Figure 54: Removing a Blank Line Card Cover ..................................................................................................................103
Figure 55: Removing the Ethernet Line Card from the Anti-static Bag...............................................................................104
Figure 56: Sliding the Ethernet Line Card into the Slot.......................................................................................................105
Figure 57: Seating an Ethernet Line Card in the Chassis...................................................................................................106
Figure 58: Tightening the Two Captive Screws on the Ethernet Line Card........................................................................106
Figure 59: Installing a Blank Slot Cover..............................................................................................................................107
Figure 60: Tightening the Captive Screws on a Blank Slot Cover......................................................................................108
Figure 61: Lifting the Locking Handle on the Blank Power Supply Slot Cover ...................................................................109
Figure 62: Aligning the Blank Power Supply Cover in the Slot...........................................................................................110
Figure 63: Lowering the Locking Handle on the Blank Power Supply Slot Cover ..............................................................110
Figure 64: Installing the Power Cord Retaining Clips .........................................................................................................111
Figure 65: Components on the AT-SBxPWRSYS1-80 DC Power Supply..........................................................................115
Figure 66: Grounding Wire Terminal...................................................................................................................................116
Figure 67: Stripping the Stranded Grounding Wire.............................................................................................................117
Figure 68: Attaching the Stranded Grounding Wire to the Grounding Terminal.................................................................117
Figure 69: On/Off Switch on the AT-SBxPWRSYS1-80 DC Power Supply...............................................................
.........118
Figure 70: Removing the Nut and Washer from the Grounding Post .................................................................................119
Figure 71: Attaching the Grounding Lug and Wire to the Grounding Post..........................................................................120
Figure 72: Securing the Grounding Wire ............................................................................................................................121
Figure 73: Stripping the solid or Stranded Grounding Wire................................................................................................122
Figure 74: Attaching the Bare Grounding Wire to the Grounding Post...............................................................................123
Figure 75: Securing the Bare Grounding Wire to the Grounding Post................................................................................124
Figure 76: Power Wire Terminals .......................................................................................................................................125
Figure 77: Stripping the Power Wires.................................................................................................................................126
Figure 78: Attaching the Power Wires to the Straight Terminal Lugs.................................................................................126
Figure 79: Opening the Plastic Cover.................................................................................................................................127
Figure 80: Removing the Terminal Screws.........................................................................................................................128
Figure 81: Connecting the Positive (+) Power Wire with a Straight Terminal.....................................................................129
Figure 82: Connecting the Negative (-) Power Wire with a Straight Terminal ....................................................................130
Figure 83: Closing the Plastic Cover over the Terminal Connectors..................................................................................131
Figure 84: Tightening the Handle Locking Screw...............................................................................................................132
Figure 85: Attaching the Power Wires to the Right Angle Terminal Lugs...........................................................................133
Figure 86: Removing the Plastic Cover..............................................................................................................................134
Figure 87: Removing the Terminal Screws.........................................................................................................................135
Figure 88: Connecting the Positive (+) Power Wire with a Right Angle Terminal...............................................................136
Figure 89: Connecting the Negative (-) Power Wire with a Right Angle Terminal..............................................................137
Figure 90: Tightening the Handle Locking Screw...............................................................................................................138
Figure 91: Stripping Solid or Stranded DC Power Wires....................................................................................................139
Figure 92: Connecting the Positive Wire With Bare Wire ...................................................................................................140
Figure 93: Connecting the Negative Lead Wire with Bare Wire..........................................................................................141
Figure 94: Connecting the AC Power Cord.........................................................................................................................149
Figure 95: Securing the Power Cord with the Retaining Clip..............................................................................................149
Figure 96: Connecting the Power Cord to an AC Power Source........................................................................................150
Figure 97: Connecting the Management Cable to the Console RS-232 Port.....................................................................152
Figure 98: User Exec Mode Prompt....................................................................................................................................153
Figure 99: SHOW STACK Command.................................................................................................................................169
Figure 100: Handle on 100Gbps Transceivers for the AT-XEM2-1CQ Line Card.......................................................
.......173
Figure 101: Installing an SFP Transceiver in the AT-XEM2-12XS Line Card.....................................................................175
Figure 102: Installing a Fiber Optic Transceiver in the AT-XEM2-4QS Line Card..............................................................175
Figure 103: Installing an 100Gbps QSFP28 Transceiver in the AT-XEM2-1CQ Line Card................................................176
Figure 104: Installing AT-SP10TW Cables in the AT-XEM2-12XS Line Card....................................................................178
Figure 105: Sliding the AT-QSFPCU Cable into the Port ...................................................................................................178
Figure 106: Disconnecting the AC Power Cord from the Power Source ............................................................................182
Figure 107: Disconnecting the AC Power Cord from the Chassis......................................................................................183
Figure 108: Lifting the Locking Handle on the AT-SBxPWRSYS2 AC Power Supply........................................................183
Figure 109: Removing the AT-SBxPWRSYS2 AC Power Supply ......................................................................................184
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
11
Figure 110: Loosening the Screw on the Locking Handle..................................................................................................185
Figure 111: Opening the Plastic Window over the Terminal Block.....................................................................................186
Figure 112: Removing the Negative Lead Wire..................................................................................................................187
Figure 113: Removing the Positive Lead Wire from the Terminal Block ............................................................................188
Figure 114: Reinstalling the Screws on the Positive and Negative Terminals....................................................................189
Figure 115: Closing the Plastic Cover ................................................................................................................................190
Figure 116: Removing the Grounding Wire........................................................................................................................191
Figure 117: Reinstalling the Nut and Washer on the Grounding Post................................................................................192
Figure 118: Lifting the Locking Handle and Removing the Power Supply..........................................................................193
Figure 119: Installing the Blank Power Supply Slot Cover .................................................................................................194
Figure 120: Lowering the Locking Handle on the Power Supply Slot Cover......................................................................195
Figure 121: Loosening the Screws on the Ethernet Line Card...........................................................................................199
Figure 122: Disconnecting an Ethernet Line Card from the Chassis..................................................................................200
Figure 123: Sliding an Ethernet Line Card from the Chassis..............................................................................................201
Figure 124: Placing the Ethernet Line Card in its Anti-static Bag.......................................................................................202
Figure 125: Loosening the Screws on the AT-FAN08 Module ...........................................................................................203
Figure 126: Disconnecting the AT-FAN08 Module from the Chassis.................................................................................204
Figure 127: Aligning the AT-FAN08 Module in the Chassis Slot........................................................................................205
Figure 128: Seating the AT-FAN08 Module on the Connector in the Chassis ...................................................................205
Figure 129: Tightening the Two Captive Screws on the AT-FAN08 Module......................................................................206
Figure 130: Pin Layout (Front View) of the Ports on the AT-XEM2-12XT and AT-XEM2-12XTm Line Cards ...................220
Figures
12
13
Tables
Table 1: XEM2 Series Line Cards .......................................................................................................................................23
Table 2: Twisted Pair Ports on the AT-XEM2-12XT Line Card ............................................................................................25
Table 3: Link and Activity LEDs on the AT-XEM2-12XT Line Card .....................................................................................26
Table 4: Twisted Pair Ports on the AT-XEM2-12XTm Line Card .........................................................................................27
Table 5: Link and Activity LEDs on the AT-XEM2-12XTm Line Card ..................................................................................28
Table 6: Link and Activity LEDs on the AT-XEM2-12XS Line Card .....................................................................................30
Table 7: Link and Activity Status LEDs for the AT-XEM2-4QS Line Card ...........................................................................31
Table 8: Link and Activity Status LED for the AT-XEM2-1CQ Line Card .............................................................................33
Table 9: NET MGMT Port LED ............................................................................................................................................36
Table 10: PORT Parameter Format .....................................................................................................................................42
Table 11: Software and Hardware Releases .......................................................................................................................44
Table 12: Maximum Number of Trunk Ports Per Switch ......................................................................................................53
Table 13: Stacking Worksheet .............................................................................................................................................67
Table 14: Stacking Worksheet Columns ..............................................................................................................................67
Table 15: Hardware Installation Procedures ........................................................................................................................70
Table 16: Configuring the Master Switch ...........................................................................................................................155
Table 17: Verifying the Master Switch ...............................................................................................................................158
Table 18: Configuring a Member Switch - Part I ................................................................................................................161
Table 19: Configuring the Member Switch - Part II ............................................................................................................164
Table 20: Verifying the Configuration of a Member Switch ................................................................................................165
Table 21: AT-XEM2 Line Cards and Fiber Optic Transceivers ..........................................................................................174
Table 22: AT-XEM2 Line Cards and Direct Connect Cables .............................................................................................177
Table 23: Hot-swapping Guidelines for XEM2 Line Cards ................................................................................................196
Table 24: Product Dimensions ...........................................................................................................................................214
Table 25: Product Weights ................................................................................................................................................214
Table 26: Ventilation Requirements ...................................................................................................................................215
Table 27: Environmental Specifications .............................................................................................................................216
Table 28: AC Voltage and Frequency Requirements ........................................................................................................217
Table 29: DC Voltage Requirements .................................................................................................................................217
Table 30: Maximum Power Consumption (Watts) .............................................................................................................217
Table 31: Typical Power Savings in eco-friendly Mode (Watts) ........................................................................................217
Table 32: Maximum Power Supply Efficiency (Based on 100V Input Voltage) .................................................................218
Table 33: Heat Dissipation (British Thermal Units/Hour) ...................................................................................................218
Table 34: Product Certifications .........................................................................................................................................219
Table 35: Port Pin Signals for the AT-XEM2-12XT and AT-XEM2-12XTm Line Cards .....................................................220
Table 36: RJ-45 Pin Signals for the Console Port on the Management Panel ......................................................
............221
Table 37: RJ-45 Pin Signals for 10 or 100Mbps for the NET MGMT Port on the Management Panel ..............................221
Tables
14
15
Preface
This guide contains the installation instructions for the AT-SBx908 GEN2
advanced modular, Layer 3 Ethernet switch. The instructions explain how
to build a virtual stack of up to four units with the Virtual Chassis Stacking
(VCStack) feature. For instructions on how to install the switch as a stand-
alone device, refer to the AT-SBx908 GEN2 Installation Guide for Stand-
alone Switches.
This preface contains the following sections:
“Document Conventions” on page 16
“Contacting Allied Telesis” on page 17
Preface
16
Document Conventions
This document uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions inform you that performing or omitting a specific action
may result in equipment damage or loss of data.
Warning
Warnings inform you that performing or omitting a specific action
may result in bodily injury.
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
17
Contacting Allied Telesis
If you need assistance with this product, you may contact Allied Telesis
technical support by going to the Support & Services section of the Allied
Telesis web site at www.alliedtelesis.com/support. You can find links for
the following services on this page:
24/7 Online Support — Enter our interactive support center to
search for answers to your product questions in our knowledge
database, to check support tickets, to learn about RMAs, and to
contact Allied Telesis technical experts.
USA and EMEA phone support — Select the phone number that
best fits your location and customer type.
Hardware warranty information — Learn about Allied Telesis
warranties and register your product online.
Replacement Services — Submit a Return Merchandise
Authorization (RMA) request via our interactive support center.
Documentation — View the most recent installation and user
guides, software release notes, white papers, and data sheets for
your products.
Software Downloads — Download the latest software releases for
your managed products.
For sales or corporate information, go to www.alliedtelesis.com/
purchase and select your region.
Preface
18
19
Chapter 1
Overview
The chapter contains the following sections:
“Overview” on page 20
“AT-SBx908 GEN2 Chassis” on page 22
“XEM2 Ethernet Line Cards” on page 23
“AT-XEM2-12XT Line Card” on page 25
“AT-XEM2-12XTm Line Card” on page 27
“AT-XEM2-12XS Line Card” on page 29
“AT-XEM2-4QS Line Card” on page 31
“AT-XEM2-1CQ Line Card” on page 33
“Management Panel” on page 35
“Power Supplies” on page 39
“AT-FAN08 Units” on page 41
“Specifying Ports in the Command Line Interface” on page 42
“Software and Hardware Releases” on page 44
Chapter 1: Overview
20
Overview
The AT-SBx908 GEN2 Switch is an advanced Layer 3+ modular switch.
The main features are listed here.
AT-SBx908
GEN2 Chassis
The chassis has the following hardware features:
3RU height
Eight slots for XEM2 Ethernet line cards
Each line card slot has 160Gbps connectivity over the backplane.
The unit supports two power supplies for primary and redundant
power.
The chassis comes with two pre-installed brackets for a standard
19-inch equipment rack.
The unit comes with two pre-installed fan modules, providing front-
to-back airflow.
The line cards, power supplies, and fan modules are hot-
swappable.
XEM2 Ethernet
Line Cards
The XEM2 Ethernet line cards are listed here:
AT-XEM2-12XT Card features 12 100Mbps and 1/10Gbps, twisted
pair ports with RJ-45 connectors.
AT-XEM2-12XTm Card features 12 100Mbps and 1/2.5/5/10Gbps,
twisted pair ports with RJ-45 connectors.
AT-XEM2-12XS Card features 12 ports for 1Gbps SFP or 10Gbps
SFP+ transceivers.
AT-XEM2-4QS Card features four ports for 40Gbps QSFP+
transceivers.
AT-XEM2-1CQ Card features one port for a 100Gbps QSFP28
transceiver.
Ethernet line cards are ordered separately. Refer to the product data
sheet on the Allied Telesis web site for a list of approved transceivers.
Management
Software and
Interfaces
Here are the management software and interfaces:
AlliedWare Plus management software
Command line interface, available locally through the Console port
or remotely over the network.
Web browser interface available remotely over the network.
The AlliedWare Plus management software comes pre-installed on the
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222

Allied Telesis SBx908 GEN2 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI