www.fmiproducts.com
116647-01E 3
This replace must be installed by a qualied (cer-
tied or licensed) service person. It has a sealed
gas combustion chamber that uses a coaxial pipe
(pipe within a pipe and having the same center)
venting system. It brings in fresh air for combus-
tion through the outer pipe and combustion gases
are exhausted through the inner pipe. If the glass
door assembly and venting pipe are not properly
seated, connected and sealed, carbon monoxide
leakage (spillage) can occur.
Carbon Monoxide Poisoning: Early signs of carbon
monoxide poisoning resemble the u, with head-
aches, dizziness or nausea. If you have these signs,
the replace may not be working properly. Get
fresh air at once! Have replace serviced. Some
people are more affected by carbon monoxide than
others. These include pregnant women, people with
heart or lung disease or anemia, those under the
inuence of alcohol and those at high altitudes.
Natural and Propane/LP Gas: Natural and pro-
pane/LP gases are odorless. An odor-making agent
is added to the gas. The odor helps you detect a gas
leak. However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
Make certain you read and understand all warnings.
Keep this manual for reference. It is your guide to
safe and proper operation of this replace.
WARNING: Any change to
this replace or its controls can
be dangerous.
WARNING: Do not use a blow-
er insert, heat exchanger insert
or other accessory not approved
for use with this replace.
Do not use any solid fuels (wood,
coal, paper, cardboard, etc.) in
this replace. Use only the gas
type indicated on replace name
plate.
Carefully supervise young chil-
dren when they are in the room
with replace.
SAFETY INFORMATION
Continued
This replace reaches high tem-
peratures. Keep children and
adults away from hot surfaces to
avoid burns or clothing ignition.
Fireplace will remain hot for a
time after shutdown. Allow sur-
faces to cool before touching.
Do not operate replace with
glass door removed, cracked
or broken.
Keep the appliance area clear
and free from combustible ma-
terials, gasoline and other am-
mable vapors and liquids.
Do not place clothing or other
ammable material on or near
replace. Never place any ob-
jects on replace.
1. This appliance is only for use with the type
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other
gases unless a certied kit is used.
2. For propane/LP replace, do not place pro-
pane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors.
To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb.
capacity.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
• if you cannot reach your gas supplier, call
the re department
4. Never install the replace
• in a recreational vehicle
• in windy or drafty areas where curtains or
other combustible (ammable) objects can
make contact with the replace front
• in high trafc areas
5. Do not modify this replace under any circum-
stances. Any parts removed for servicing must
be replaced prior to operating replace.