Technical Information KPP PPU
11029257 • Rev BB • July 201310
Ordering Nomenclature
Codes and Denitions
Code Description
1 Flat end: Typical use, Sauer-Danfoss Series 90 pump and motor, M46 pump and motor, Series 42
pump (M46 pump pending)
2 Conical end: Typical use, Sauer-Danfoss Series 51 and 51-1 MV cartridge type motor
Electrical Conguration
Code Description
2 Non-directional: Common, supply voltage 4.5 to 8.5 Vdc, 3 wire connection, speed sensing only
with wire fault detection
3 Directional: Common, supply voltage 4.5 to 8.5 Vdc, 4-wire connection, direction and speed
sensing with wire fault detection capability on both its speed and direction signals. Can also be
used if only speed sensing is required (3 wire connection)
4 Directional: Special, supply voltage 4.5 to 8.5 Vdc, 4-wire connection, directional sensing signal
compatible with the standard DC2 digital input lines. Higher current sinking capability and no wire
fault detection for the direction signal only which can sink up to 20 mA and source nothing (open
collector).
5 Directional: Special, supply voltage 4.5 to 8.5 Vdc, 4-wire connection, direction and speed sensing
with wire fault detection capability on both its speed and direction signals. Capable of driving
higher currents from its outputs. Special provision to lter the speed output signal for reducing
electromagnetic emissions
6 Non-Directional: Common, supply voltage 7 to 32 Vdc, 3 wire connection, speed sensing only
with limited wire fault detection
7 Directional: Special, supply voltage 4.5 to 8.5 Vdc, 4 wire connection, direction and speed sensing
with wire fault detection capability, low current, features quadrature (decoded) directional
output**
8 Directional: Common, supply voltage 4.5 to 8.5 Vdc, 4 wire connection, direction and speed
divided by 2 sensing with wire fault detection capability on both its speed and direction signals
9 Directional: Special, supply voltage 4.5 to 8.5 Vdc, 4 wire connection, high current, direction and
speed sensing with wire fault detection capability, high current, features quadrature (decoded)
directional output**
A Directional: Special, supply voltage 7 to 32 Vdc, 4 wire connection, direction and speed sensing
with wire fault detection capability, high current, features quadrature (decoded) directional
output**
B Non-directional: Special, supply voltage 4.5 to 8.5 Vdc, 3 wire connection, speed sensing with
wire fault detection capability, high current, ltered speed output
**Do not attempt to apply a quadrature output PPU without rst consulting with a Sauer-Danfoss
eld applications engineer for specic application requirements.
Mechanical Conguration (Housing)
Electrical Connector
Code Mating connector kit description Sauer-Danfoss part number
4 Delphi/Packard Weather Pack 3 pin shroud K08620
Delphi/Packard Weather Pack 4 pin tower, used when
directional signal is required
K03379
5 Delphi/Packard Metri-Pack 3 pin K10309
6 Turck Eurofast 4 pin K14956 (straight); K14957 (right angle)
7 Deutsch, 3 pin K22335
Deutsch, 4 pin, used when directional signal is required K 23511
8 Delphi/Packard Metri-Pack 4 pin plug K22254