Anolis Ambiane PW User manual

Category
Stroboscopes & disco lights
Type
User manual

This manual is also suitable for

1
User manual
Ambiane PW
The unit generates light by means of high power LEDs. The product was designed for indoor use only.
1. Attention
Theunitmustbeinstalledbyaqualiedelectricianinaccordancewithall
national and local electrical and construction codes and regulations.
The unit was designed for indoor use only.
Avoid looking directly into the LED light beam at close range!
Donotinstalltheunitnearhighlyinammableliquidsormaterials.
Do not allow anything to rest on the unit.
Donotinstalltheunitnearanopename.
Do not install the unit in dirty,dusty or badly ventilated location.
Sucientairaccessingtothehousingoftheunithastobeensured,
there must not be any heat or anti-noise insulation within a 0.6m x 0.6m
areaaroundtheunit(non-ICratedxture).
Resistance of the equipment is designed for electromagnetic environments E1, E2, E3
according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family
standard for audio, video, audiovisual and entertainment lighting control apparatus for
professional use. Part 2: Immunity.
The installation company should check levels of possible interferences above the tested levels
E1,E2,E3givenbythisstandard(e.g.transmittersinsurroundingarea)beforeinstallingtheequipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility
of multimedia equipment – Emission Requirements according to class B.
Suitable for fastening on Unsuitable for covering by heat insulation
non-ammablesurfacesonly material
Alvays switch o power suply of the unit before connecting or disconnecting the unit
2
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeunitintotheopening.Fastenthexturebymeansoftwospringfasteners(2)totheopening
Toconnectneededcablestothexture,unscrewtwoscrews(4)fromtheplasticcover(3)andchipneeded
plasticthin-walledcovers(6)oinordertopasscablestotheconnectionblocks(5).
Theconnectionblocks(5)havethefollowingwiring:
Theprimarypowerinputservesforastandardpower(e.g.ArcPowerforAmbiane).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled.
fthextureissuppliedviathesecondarypower,thelightoutputofthexturecanbesetbyatrimmer.
Thexturecanbecontrolledbyoneofthefollowingmethods:DMX512
0-10V
DALI
ThextureisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALIchain
(In/Outmethod).
3
DMX connection 0-10V connection Power connection
PCB Function PCB Function PCB Function
0V - Shield 0V 0V + Power +
D+ Signal(+) D+ +10V - Power-
D- Signal(-)
3. DMX and DALI address setting and control
The DIP switch, located next to the connection blocks, allows to set a method of control, run test and also allows
toswitchthexturetotheupdatemodeincaseofsoftwareupdate.
DIP 10 - if switched to ON=test light
DIP11-selectionofxturecontrol:OFF=DMX512orDALI,ON=0-10V
DIP12-changefromOFFtoONpositionswitchesthexturetotheupdatemode(switchingtotheupdate
modeisnotnecessaryIftheRobeUploaderisusedforxtureupdate).
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to512.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLEDonPCBsignalswayofDMX
address setting:
LEDlights-DMXaddressissetbymeansoftheDIPswitch.
LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP 11 has to be set in OFF position.
ExampleofDMXaddresses:
DALI control
AddressingofthextureismadebymeansofanexternalDALIcontroller.TheexternalDALIcontrollerhasto
sendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontrolofthexture(xturewillnotrespond
toDMXcommands)anddeactivatingcommand(0=OFF)tostopcontrolofthexture.
DIP 11 has to be set in OFF position.
4
Note:IfDIP11=OFF(xtureiscontrolledbyDMXorDALI),therstcomingcommandswitchesthexturetothe
correspondingoperationmode(DMXoperationbyaDMXcommand,DALIoperationbyaDALIcommand).E.g.
thexturestaysinaDALIoperationandcomingDMXcommandswitchesthexturetoDMXoperation.Next
commandisaDALIcommandandswitchesthexturetotheDALIoperationetc.Ifyouneedthepermanent
DALIoperation,youhavetosendaDALIcommand8tothexture.
0-10V control
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI commands.
4. RDM
ThisxturesupportsRDMoperation.RDM(RemoteDeviceManagement)isabi-directionalcommunication
protocolforuseinDMX512controlsystems,itisthenewopenstandardforDMX512devicecongurationand
status monitoring.
RDMallowsyoutosetDMXaddress,selectDMXmodeandreadoutsoftwareversionofthexture.The.RDM
protocolisalsousedforthesoftwareupdateofthexturebymeansoftheRobeUploader.
5. Anti-glare ring installation
Inserttheantiglarering(1)intothextureuntilthreelocks(2)snapintoslots(3).
6. Adapter ring installation
1.Removebothspringfasteners(2)byunscrewingthefourscrewsM4x10(1).
2.Slidetheadapterring(4)ontothehousingofthexture.Screwthenewfasteners(3)onthehousing.
UseoriginalscrewsM4x10(1).
5
7. DMX protocol
version 1.1
Mode 1
Channel
Mode 2
Channel
Value Function Type of control
1 1
0-255
Dimmer
Light intensity coarse 0% -->100% proportional
- 2
0-255
Dimmer Fine
Light intensity from min. -->max. proportional
8. Technical specications
Inputvoltage: 24VDC
Max.powerconsumption: 40W
Protection class : CE: (ClassIII)
ETL: Class 2 or LVLE
Beam angle: 67°, 80° with anti-glare ring
Colourtemperature: 2700K,3200K,4000K,5000K,6500K
Control: DMX,DALI,0-10V,RDMcompatible
DMXchannels: 1(Mode1),2(Mode2)
Typical Lumen maintenance: 70%@ 50,000 hours
Led life expectancy: minimum 50,000 hours
Operatingambienttemp.range:  -20°C/+45°C(-4F/+113F)
Operatingtemperature: 75°C@Ambient+35°C(167°F@Ambient+95°F)
Totalheatdissipation: 136BTU/h(calculated)
Cooling : convection
Totalheatdissipation: 136BTU/h(calculated)
Housing: alluminium
Weight: 1.8kg
Installation method: via two spring fasteners
IC rating: non-IC rated
Power/DMX/DALIconnection: screwconnectionblockDegsonDG306-5.0-02P
(Wirerange:22-14AWG(UL),1.5mm
2
(IEC))
Max.distancebetweenAmbianeand
ArcPowerforAmbiane: 1m(for2x18AWGcable)
Protectionfactor: IP20(withoutdiuserglass),IP20/IP54(withDiuserGlass)
AmbianewithoutDiuserGlass AmbianewithDiuserGlass
9. Optional Accessories
ArcPowerforAmbiane(P/N10063035)
Anti-GlareRing(P/N10980386)
DiuserGlassFrosted(P/N10980387)
AdapterRing(235-255mm)(P/N10980388)
10. Maintenance
Keepthextureclean,especiallylightsourceandtheribbedhousing.
6
11. Dimensions
mm [inch]
7
12. Software update
Software update by means of the DSU le.
The following items are required in order to update software:
-PCrunningWindowsorLinuxormacOS
-DSUle
-FlashcableRS232/DMX(P/N13050624)ortheRobeUniversalInterface/RobeUniversalinterfaceWTX.
Toupdatesoftwareinthexture:
1.DSUleisavailablefromAnoliswebsiteathttps://www.anolislighting.com/
FilewithextensionzipisintendedforWindows(usedandtestedfromXPtoW10on32/64bitsystems).
FilewithextensiontbzisintendedforLinux(usedandtestedonDebianandUbuntu32/64bit).
File with extension dmg is intended for
macOS(usedandtestedonOSXuptoSierra)XQuartzrequired,
install it from https://www.xquartz.org/
Savethedownloadletoafolderonyourcomputer.
Incasethatyouusewindows,extractlesintheziple(e.g.DSU_Ambiane_18051040.zip)
2.SwitchthextureoanddisconnectthexturefromDMXcontroller(IfyouuseDALIcontrol,switcho
theDALIcontroller).
3.IfyouusetheashcableRS232/DMX,connectaserialportofyourcomputerwithDMXinputofthexture
by means of this cable (probably you will need some USB to RS 232 converter if your computer has
USBportsonly).
If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface
bymeansoftheUSBcableandDMXinputofthexturewiththeDMXoutputoftheRobeUniversalInterface
viaaDMXcable.
4.Switchthextureonandswitchittotheupdatemode(svitchthe
DIP12fromOFFtoONposition)
.
Werecommendtocancelallrunningprogramsonyourcomputerbeforestartingthesoftwareuploader.
5.Double-clickthesoftwareuploaderle(e.g.DSU_Ambiane_18051040.exe)in
theextractedles.TheSoftwareUploaderprogramwillstartrunning.
8
6.Selectcorrect"COM"numberifyouusea
FlashcableRS232/DMX
or select "
Robe Universal Interface "
if you use the
RobeUniversalInterface/RobeUniversalInterfaceWTX
and then click on the "Connect" button.
7. If the connection is OK, click the “Start Uploading" button to start software uploading. It will take several
minutes to perform software update.
If the option "Incremental Update" is not checked, all processors will be updated (including processors with
thesamesoftwareversion).
If you wish to update only processors with new version of software, check the “Incremental Update
box“.
Avoid interrupting the process. Update status is being displayed in the "Info Box" window.
Whentheupdateisnished,thelinewiththetext“Fixtureissuccessfullyupdated“willappearin
this window.
8.SwitchthextureoandsettheDIP12toOFFposition.
Incaseuploadprocessisinterrupted(e.g.powerloss),thexturestaysin“Updatingmode”andyouwillhave
to repeat the software update again.
Software update by means of the Robe Uploader
Anotherway,howtoupdatesoftwareinthextures(especiallylargeinstallationofxtures)istousetheROBE
Uploader.ItisasoftwareforautomatizedsoftwareupdateofRobeandAnolisxtures.Ittakesadvantageof
RDMsupport.
Thextureshastobeconnectedinadaisy-chain(max.32xtures)andvia
the
Robe Universal Interface/Robe
UniversalInterfaceWTX
and a USB cable connected to the control PC with the Robe Uploader running.
The control PC should be connected to the Internet.
9
The Robe Uploader software and user manual is available at :
https://www.robe.cz/robe-uploader/
Note:
IfyoudothesoftwareupdatebymeansoftheRobeUploader,switchingxturestotheupdatemode(andfrom
theupdatemode)ismadeautomatically,withoutneedtoswitchtheDIP12toONposition.
TheRobeUploadersoftwarecannotbeusedifxturesareconnectedbymeansofDALIconnection.
Version1.9March4,2021
Specications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Anolis Ambiane PW User manual

Category
Stroboscopes & disco lights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI