Extron VLR 302 Installation guide

Type
Installation guide

This manual is also suitable for

1
VoiceLift Pro Microphone Kits • Setup Guide
IMPORTANT NOTE:
Go to www.extron.com for the complete user guide, installation instructions, and specications
before connecting the product to the power source.
This guide provides instructions for an experienced installer to set up the Extron VLP 302 VoiceLift Compact Pendant Microphone,
the VLH 302 VoiceLift Handheld Microphone, the VLC 302 Charging Station, and the VLR 302 Receiver in a system with a
PVCA 452 Controller Amplier or PVS 407D PoleVault Digital Switcher.
Connecting the VLC 302 Charger and Charging the Microphones
11 22
LED
44
11 22
LED
44
NOTE: The charging station is to be used with NiMH rechargeable batteries
only.
To connect the charger and charge the microphone(s):
1. Connect the 5 VDC, 2.6 A wall charger (with USB Mini-B adapter) to a
110-130 VAC (US) or a 100-240 VAC (international), 50-60 Hz power
source (1).
2. Connect the USB mini plug end of the adapter to the USB mini jack located
on the back of the VLC 302 (2).
NOTE: The charger can also be powered by a USB source using a
mini USB cable.
3. If required, unscrew and remove the microphone battery cover to install the
battery. Insert the battery, aligning the + and – poles as indicated inside the
compartment.
VLP 302
(Cover Removed)
VLH 302
(Cover Removed)
+
+
_
BATTERY
BATTERY
4. Insert the microphone into one of the charger slots (4). The microphone
LED turns red to indicate charging, and green when the microphone is fully
charged.
NOTE: Microphones can be left to charge for extended periods.
CAUTION: Do not replace the batteries with an incorrect type. Use only
rechargeable batteries specified or provided by Extron, or alkaline batteries.
ATTENTION:
Do not attempt to charge alkaline batteries.
Be sure to replace the battery with the correct type and to dispose of used
batteries appropriately.
2
Setting Up the Microphones
VLP 302 Pendant Microphone
1. Verify that the battery is installed and fully charged.
2. Set the microphone(s) for either Teacher or Student mode using the
DIP switch, accessible from beneath the battery cover (see 2 at right):
In Teacher mode (default), all microphone features are fully
functional. Set the dip switch to the OFF (down) position to enable
“teacher” mode.
In Student mode, all buttons are disabled except for power. Set
the dip switch to the ON (up) position to enable “student” mode.
3. Apply the appropriate label (provided) to identify the microphone
(see 3 at right).
4. To wear as a pendant microphone:
a. Open the microphone clip (see a at right).
b. Slide up the lanyard lock under the clip, then release the clip (b).
c. Place the lanyard
around your neck.
Adjust both lanyard
straps so the
microphone rests
approximately
6 inches (15.2 cm)
below your chin.
2
3
TEACHER
~ 6
b
a
Press to
open clip
Lanyard
Lock
~ 6
Installing the VLR 302 Receiver
The VLR 302 Receiver outputs audio signals from the microphones as one balanced mono line
level signal to the PVCA 452 and PVS switcher. Connect the VLR 302 to the PVCA 452 or
PVS 407D PoleVault switcher as shown below. For mounting instructions, see the VoiceLift Pro
User Guide.
A Connect the PVCA 452 or PVS 407D to the VLR 302 output port using the included shielded
RJ-45 cable as shown below.
NOTE: The receiver is powered by the PVS switcher.
OUTPUT
1 C C2
RELAY
VLR 302 Receiver
LAN 1 LAN 3
LAN 2 LAN 4
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
4/8
Ω
HDMI HDMI
1/2
SIG LINK SIG LINK
3/4 56
INPUTS OUTPUT
AUDIO OUT
PVS 407D
AMPLIFIED AUDIO OUT PAGING
SENSOR
PVT IN PVT IN
LR
AUX
OVER PVTREMOTE
VOICELIFT
LAN
INPUT 7
+V
LR
RS-232
Tx Rx
IR
S GG
CLASS 2 WIRING
LAN
- - A MAX
POWER
12V
L R
Out
POWER
12V
2.0 A MAX
INPUTS
OUTPUTS
L
AUDIO
R
HDMI/CEC/ARC
L
AUDIO
VOICELIFT
DIGITAL R
AUX
CLASS 2 WIRING
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
4/8
Ω
LR
AMPLIFIED AUDIO
PAGE
SENSOR
OUTPUT
1 C C2
RELAY
VLR 302 Receiver
PVCA 452
PVS 407D PoleVault Switcher
Out
B These relays can be integrated with various systems, or connected to a digital input on an Extron MediaLink MLC or a control
processor for Instant Alert capability (see the VoiceLift Pro User Guide for details). Wire this 4-pole captive screw Relay
connector for relays 1 and 2, if necessary.
AB
3
VLH 302 Handheld Microphone
1. Verify that the battery is installed and fully charged.
2. Turn the microphone on by sliding up the power switch (2). One of the
LINK LEDs on the VLR 302 receiver illuminates to indicate that connection
has been established.
NOTE: Each VoiceLift kit includes VLP 302/VLH 302 microphones
and VLR 302 receivers that have already been paired. Follow the
steps on the next page to pair the microphone if necessary.
3. Speak in a normal tone of voice, adjusting the volume level (3) as
necessary (to save the volume level, see Saving the Microphone
Volume Level).
4. When nished, return the microphone to the charging station.
VLH 302
(Cover Removed)
+
Status
LED
2
3
5. Turn the microphone(s) on by holding the power button (5) for 3 seconds.
One of the LINK LEDs on the VLR 302 receiver illuminates to indicate that
connection has been established.
NOTE: Each VoiceLift kit includes VLP 302/VLH 302 microphones
and VLR 302 receivers that have already been paired. Follow the
steps on the next page to pair the microphone if necessary.
6. Speak in a normal tone of voice, adjusting the volume level (6) as
necessary (to save the volume level, see Saving the Microphone Volume
Level).
7. When nished, return the microphone to the charging station.
Status
LED
5
6
Saving the Microphone Volume Level
Saving the microphone level allows the microphone to recall the stored volume level setting when powering on. To save the
microphone volume level:
1. Adjust the volume on each microphone to the desired level.
2. Manually power down each microphone:
For the pendant microphone, press and hold the power button until the LED turns off.
For the handheld microphone, slide power switch to off position.
3. Wait 30 seconds before turning the microphones on or placing them in the charger.
4
Auxiliary Audio Connection
VLP 302
The 3.5 mm mono TS (tip/sleeve) aux audio input on the side of the VLP 302 microphone can be
used to connect an optional lavalier microphone (see the diagram below for connector wiring).
Tip
Sleeve
VLH 302
The aux audio input on the VLH 302 microphone can be used to connect audio devices (such as
mobile devices, MP3 players, etc.) to wirelessly transmit audio to the room speakers.
Use a 3.5 mm stereo TRS (tip/ring/sleeve) cable to connect the audio source to the aux audio input
on the side of the VLH 302 microphone (see the diagram below for connector wiring).
Sleeve (S)
Ring (R)
Tip (T)
Tip
Sleeve(s)
Ring
Ring
Tip
Tip
Sleeve
Sleeve
Tip
Unbalanced Input
TRS Connector
RCA Connector
Left
Right
Left
Right
Balanced Input or Output
Balanced Mono Audio
Unbalanced Stereo Audio
Tip
Sleeve
Ring
Tip
Sleeve
Unbalanced Output
Left
Tip
Sleeve(s)
NO Ground Here
NO Ground Here
Tip Right
CAUTION
For unbalanced audio, connect the
sleeves to the ground contact.
DO NOT connect the sleeves to the
negative (-) contacts.
Tip
Sleeve
NO Ground Here
Ring (R)
Ring
Tip (T)
Tip
Tip
Tip
Sleeve (S)
Ring (R) = Right Channel
Tip (T) = Left Channel
Sleeve (S)
(input or output)
(input or output)
Sleeve
Sleeve
3.5 mm Audio Jack
TRS
Auxiliary Stereo
Audio Input
Auxiliary Mono
Audio Input
Auxiliary Stereo
Audio Input
Auxiliary Mono
Audio Input
5
Pairing with the VLR 302 Receiver
Each VoiceLift kit includes VLP 302/VLH 302 microphones and VLR 302 receivers that have already been paired. If needed, follow
the steps below to pair microphones with a receiver.
Verify which Microphones are Paired
1. Ensure that the microphones are fully charged. Power each microphone on, one at a
time, to determine if the microphones are paired to the VLR 302 receiver.
NOTES:
As each microphone is powered on, one of the VLR link slot LEDs (see A
at right) illuminates if the microphone is paired.
Only one microphone can be paired to each LINK slot on the VLR receiver.
2. Once you have determined which microphones are paired, turn them o.
Pair New Microphones
Follow these steps to pair each microphone to the VLR 302 receiver.
NOTE: All paired microphones must be turned o before pairing new microphones.
1. Press and hold the LINK button on the VLR 302 receiver (see B in the image above) for 4 seconds to start pairing mode.
If LINK slots are available, one of the LINK LEDs blinks to indicate that pairing mode has started.
NOTES:
Once initiated, pairing mode is enabled for 30 seconds. Users must repeat the process if they have
exceeded the 30 second pairing window or if pairing was not successful.
Receiver Pairing/Discovery mode can also be enabled remotely using Product Configuration
Software (PCS) or SIS comands (see the VoiceLift Pro Microphone Kits User Guide). Commands
can be sent to the receiver through direct USB connection using a PVCA 452 connection or PVS
switcher connection.
If adding a new microphone to the system (or replacing a current microphone), and both Link slots
are currently assigned, reset the VLR 302 to clear the pair history (see Clearing Pair History on
the next page).
2. Follow the steps below for your microphone model:
For the VLP 302: Ensure that the microphone is powered off.
NOTE: The VLP microphone must be in “TEACHER” (o)
mode in order to pair.
Then, press and hold the POWER and FUNCTION buttons (see
A and B at right) simultaneously for 4 seconds until the status
LED blinks red and green, indicating pairing mode has started.
For the VLH 302: Ensure that the microphone is powered on.
NOTE: The VLH microphone must be in “STUDENT” (on)
mode in order to pair.
Then, press and hold the LINK button, located beneath the battery cover (see C at right), for 4 seconds.
The microphone status LED changes from solid amber to alternating red and green, indicating that pairing
mode has started.
NOTES:
The receiver assigns the microphone to the first available LINK slot.
If the microphone is paired successfully, one of the LINK LEDs on the VLR receiver lights solid green.
3. After pairing the microphones, verify that they have been set up properly as shown in the previous section, Setting up the
Microphones on page 2. Repeat steps 1-3 for each microphone being paired.
A B
B
A
C
6
© 2020-2023 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron
Safety and Regulatory Compliance Guide on the Extron website.
68-2957-50
Rev. C
11 23
Clearing Pair History
Follow these steps to reset the VLR 302 pairing history, if needed, using the front panel
Reset button (see A at right). The following reset mode clears pairing history, but
retains settings and usage data.
1. Hold down the Reset button for about three seconds until the Power LED blinks
once.
2. Release and press the Reset button momentarily (for less than one second) within
one second.
Both Link 1 and Link 2 LEDs blink one time, simultaneously, to conrm that the pairing
history has been cleared. Unsolicited response “Pair00” is sent.
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron VLR 302 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI